Daesan FR601 Current 6.0 amperes voltage 50 to 1000 volt Datasheet

CURRENT 6.0 Amperes
VOLTAGE 50 to 1000 Volts
FR601 THRU FR607
Features
· Fast switching
· Low leakage
· Low forward voltage drop
· High current capability
· High current surge
· High reliability
P-6
0.360(9.1)
0.340(8.6)
DIA.
1.0(25.4)
MIN.
0.360(9.1)
0.340(8.6)
Mechanical Data
· Case : P-6 molded plastic body
· Terminals : Plated axial lead solderable per MIL-STD-750,
method 2026
· Polarity : Color band denotes cathode end
· Mounting Position : Any
· Weight : 0.074 ounce, 2.08 gram
1.0(25.4)
MIN.
0.052(1.3)
0.048(1.2)
DIA.
Dimensions in inches and (millimeters)
Maximum Ratings And Electrical Characteristics
(Ratings at 25℃ ambient temperature unless otherwise specified, Single phase, half wave 60Hz, resistive or inductive
load. For capacitive load, derate by 20%)
Symbols
FR
601
FR
602
FR
603
FR
604
FR
605
FR
606
FR
607
Units
Maximum recurrent peak reverse voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC blocking voltage
VDC
50
100
200
400
600
800
1000
Volts
Maximum average forward rectified current
0.375"(9.5mm) lead length TA=75℃
I(AV)
6.0
Amps
Peak forward surge current 8.3ms single
half sine-wave superimposed on rated load
(JEDEC method)
IFSM
300
Amps
VF
1.3
Volts
Maximum instantaneous forward voltage
at 6.0A
Maximum DC reverse current at rated DC
blocking voltage
Maximum full load reverse current full cycle
average. 0.375"(9.5mm) lead length at
TL=55℃
10
μA
IR
150
Maximum reverse recovery time (Note 1)
Trr
Typical junction capacitance (Note 2)
CJ
150
pF
TJ
TSTG
-65 to +150
℃
Operating junction and storage
temperature range
Notes:
(1) Test conditions: IF=0.5A, IR=1.0A, Irr=0.25A.
(2) Measured at 1MHz and applied reverse voltage of 4.0 Volts.
150
250
500
ns
RATINGS AND CHARACTERISTIC CURVES FR601 THRU FR607
FIG.2-MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
8
SINGLE PHASE HALF WAVE 60Hz
RESISTIVE OR INDUCTIVE LOAD
6
PEAK FORWARD SURGE CURRENT(AMPERES)
AVERAGE FORWARD CURRENT(A)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
4
2
0
0
25
50
75
100
125
150
175
AMBIENT TEMPERATURE ( ℃)
600
8.3m SINGLE HALF SINE WAVE
(JEDEC Method)
500
400
300
200
100
0
1
5
FIG.3-TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4-TYPICAL JUNCTION CAPACITANCE
1000
500
200
100
100
JUNCTION CAPACITANCE(pF)
INSTANTANEOUS FORWARD CURRENT(AMPERES)
10
40
10
1
TJ=25℃
60
40
TJ=25℃
20
10
6
4
Pulse Width=300mS
2
1% Duty Cycle
1
0.1 0.2
0
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
0.4
1
INSTANTANEOUS FORWARD VOLTAGE (VOLTS)
FIG.5-TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
50W
NON INDUCTIVE
10W
NON INDUCTIVE
+0.5A
(+)
25Vdc
(APPROX)
(
D.U.T.
PULSE
GENERATOR
(NOTE2)
Trr
0
-0.25A
)
1W
NON INDUCTIVE
OSCILLOSCOPE
(NOTE1)
NOTES: 1.Rise Time=7ns max. input impedance=1
megohm 22pF
2.Rise Time=10ns max. source impedance
=50 ohms
2
4
REVERSE VOLTAGE. (V)
-1.0A
1cm
SET TIME BASE FOR 50/100 ns/cm
10
20
40
100