POWER LPS40 Series 40 Watts Data Sheet Total Power: 40 - 55 Watts Input Voltage: 85 - 264 Vac 120 - 300 Vdc # of Outputs: Single SPECIAL FEATURES Universal input 3” x 5” footprint Less than 1U high Remote sense Built-in EMI filter Low output ripple Adjustable output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available RoHS compliant SAFETY cUL 60950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P94100375 (74-sec) 203 CB Certificate and report 1119, 1125, 1126, 1127 CE Mark (LVD) Electrical Specifications Input Input range 85 - 264 Vac; 120 - 300 Vdc Frequency 47 - 440 Hz Inrush current < 18 A peak @ 115 Vac; < 36 A peak @ 230 Vac, cold start @ 25 °C Input current 1 A max. (RMS) @ 115 Vac Efficiency 70% typical at full load EMI filter FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 class B conducted Safety ground leakage current < 0.5 mA @ 50/60 Hz, 264 Vac input Output Maximum power 40 W for convection; 55 W with 30CFM forced air Adjustment range -5, +10% minimum Hold-up time 20 ms @ 40 W load, 115 VAC nominal line Overload protection Short circuit protection on all outputs Case overload protected @ 110-145% above peak rating Overvoltage protection 5 V output; 5.7 to 6.7 Vdc. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5 V lead drop minimum Will operate without remote sense connected Reverse connection protected LPS40 Series Data Sheet Environmental Specifications Operating temperature 0° to 50 °C ambient. Derate each output 2.5% per degree from 50° to 70 °C, -20 °C start up. Storage temperature -40 °C to +85 °C Temperature coefficient ± 0.4% per °C Electromagnetic susceptibility Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Humidity Operating; non-condensing 5% to 95% RH Vibration Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational MTBF demonstrated > 550,000 hours at full load and 25 °C ambient conditions Ordering Information Minimum Load Maximum Load Maximum Load with Convection with 30CFM Cooling Forced Air Model Number Output Voltage LPS41 3.3 V 0A 8A 11 A 12 A ± 2% 50 mV LPS42 5V 0A 8A 11 A 12 A ± 2% 50 mV LPS43 12 V 0A 3.3 A 4.5 A 5A ± 2% 120 mV LPS44 15 V 0A 2.6 A 3.6 A 4A ± 2% 150 mV LPS45 24 V 0A 1.7 A 2.3 A 2.5 A ± 2% 240 mV LPS48 48 V 0A 0.9 A 1.2 A 1.3 A ± 2% 480 mV Peak Load1 Regulation2 Ripple P/P(PARD)3 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is not intended for sale to End Users. Power Derating Curve 55W 30 CFM Forced Air Cooling 40W Output Power (Watts) 30W 20W Natural Convection Cooling 27.5W 20W 10W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C LPS40 Series Data Sheet Mechanical Drawing 1. Specifications subject to change without notice. 2. All dimensions in inches (mm), tolerance is ±0.02”(±0.5mm) 3. Mounting holes M1 and M2 should be grounded for EMI purposes. 4. Mounting hole M1 is safety ground connection. 5. Specifications are for convection rating at factory settings at 115 Vac input, 25°C unless otherwise stated. 6. Warranty: 2 year 7. Weight: 0.5 lbs/0.23kg Pin Assignments Connector LPS41 LPS42 LPS43 LPS44 LPS45 LPS48 SK1-1 Line Line Line Line Line Line SK1-3 Neutral Neutral Neutral Neutral Neutral Neutral SK2-1 +3.3V +5V +12V +15V +24V +48V SK2-2 SK2-3 SK2-4 +3.3V +3.3V Common +5V +5V Common +12V +12V Common +15V +15V Common +24V +24V Common +48V +48V Common SK2-5 Common Common Common Common Common Common SK2-6 Common Common Common Common Common Common SK201-1 +Sense +Sense +Sense +Sense +Sense +Sense SK201-2 -Sense -Sense -Sense -Sense -Sense -Sense Mating Connectors AC Input Molex 09-50-8031 (USA) 09-93-0300 (UK) PINS: 08-52-0113 DC Outputs Molex 09-50-8061 (USA) 09-93-0600 (UK) PINS: 08-52-0113 Remote Sense Molex 22-01-2025 PINS: 08-52-0123 Artesyn Embedded Technologies Connector Kit #70-841-006, includes all of the above WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal.. www.artesyn.com For more information: www.artesyn.com/power For support: [email protected] LPS40 Series-DS 18Mar2016