Artesyn LPS41 Total power: 40 - 55 watt Datasheet

POWER
LPS40 Series
40 Watts
Data Sheet
Total Power: 40 - 55 Watts
Input Voltage: 85 - 264 Vac
120 - 300 Vdc
# of Outputs: Single
SPECIAL FEATURES
ƒƒ Universal input
ƒƒ 3” x 5” footprint
ƒƒ Less than 1U high
ƒƒ Remote sense
ƒƒ Built-in EMI filter
ƒƒ Low output ripple
ƒƒ Adjustable output
ƒƒ Overvoltage protection
ƒƒ Overload protection
ƒƒ 110 KHz switching frequency
ƒƒ LPX40 enclosure kit available
ƒƒ RoHS compliant
SAFETY
ƒƒ cUL
60950
E132002
ƒƒ CSA
CSA 22.2-234 Level 3 LR53982C
ƒƒ NEMKO EN 60950/EMKO-TUE P94100375 (74-sec) 203
ƒƒ CB
Certificate and report
1119, 1125, 1126, 1127
ƒƒ CE Mark
(LVD)
Electrical Specifications
Input
Input range
85 - 264 Vac; 120 - 300 Vdc
Frequency
47 - 440 Hz
Inrush current
< 18 A peak @ 115 Vac; < 36 A peak @ 230 Vac, cold start @
25 °C
Input current
1 A max. (RMS) @ 115 Vac
Efficiency
70% typical at full load
EMI filter
FCC Class B conducted; CISPR 22 Class B conducted;
EN55022 Class B conducted; VDE 0878 PT3 class B conducted
Safety ground leakage current
< 0.5 mA @ 50/60 Hz, 264 Vac input
Output
Maximum power
40 W for convection; 55 W with 30CFM forced air
Adjustment range
-5, +10% minimum
Hold-up time
20 ms @ 40 W load, 115 VAC nominal line
Overload protection
Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overvoltage protection
5 V output; 5.7 to 6.7 Vdc. Other outputs 10% to 25% above
nominal output
Remote sense
Compensates for 0.5 V lead drop minimum
Will operate without remote sense connected
Reverse connection protected
LPS40 Series Data Sheet
Environmental Specifications
Operating temperature
0° to 50 °C ambient. Derate each output 2.5% per degree from 50° to 70 °C, -20 °C start up.
Storage temperature
-40 °C to +85 °C
Temperature coefficient
± 0.4% per °C
Electromagnetic susceptibility
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Humidity
Operating; non-condensing 5% to 95% RH
Vibration
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500
Hz, operational
MTBF demonstrated
> 550,000 hours at full load and 25 °C ambient conditions
Ordering Information
Minimum
Load
Maximum Load Maximum Load
with Convection with 30CFM
Cooling
Forced Air
Model
Number
Output
Voltage
LPS41
3.3 V
0A
8A
11 A
12 A
± 2%
50 mV
LPS42
5V
0A
8A
11 A
12 A
± 2%
50 mV
LPS43
12 V
0A
3.3 A
4.5 A
5A
± 2%
120 mV
LPS44
15 V
0A
2.6 A
3.6 A
4A
± 2%
150 mV
LPS45
24 V
0A
1.7 A
2.3 A
2.5 A
± 2%
240 mV
LPS48
48 V
0A
0.9 A
1.2 A
1.3 A
± 2%
480 mV
Peak Load1
Regulation2
Ripple
P/P(PARD)3
1. Peak current lasting < 30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as
a standalone product. EMC compliance to appropriate standards must be verified at the system level. This product is for sale to OEMs and
System Integrators, including through Distribution Channels. It is not intended for sale to End Users.
Power Derating Curve
55W
30 CFM Forced Air Cooling
40W
Output
Power
(Watts)
30W
20W
Natural
Convection
Cooling
27.5W
20W
10W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
LPS40 Series Data Sheet
Mechanical Drawing
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is
±0.02”(±0.5mm)
3. Mounting holes M1 and M2 should be grounded for EMI
purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings
at 115 Vac input, 25°C unless otherwise stated.
6. Warranty: 2 year
7. Weight: 0.5 lbs/0.23kg
Pin Assignments
Connector
LPS41
LPS42
LPS43
LPS44
LPS45
LPS48
SK1-1
Line
Line
Line
Line
Line
Line
SK1-3
Neutral
Neutral
Neutral
Neutral
Neutral
Neutral
SK2-1
+3.3V
+5V
+12V
+15V
+24V
+48V
SK2-2
SK2-3
SK2-4
+3.3V
+3.3V
Common
+5V
+5V
Common
+12V
+12V
Common
+15V
+15V
Common
+24V
+24V
Common
+48V
+48V
Common
SK2-5
Common
Common
Common
Common
Common
Common
SK2-6
Common
Common
Common
Common
Common
Common
SK201-1
+Sense
+Sense
+Sense
+Sense
+Sense
+Sense
SK201-2
-Sense
-Sense
-Sense
-Sense
-Sense
-Sense
Mating Connectors
AC Input
Molex 09-50-8031 (USA)
09-93-0300 (UK)
PINS: 08-52-0113
DC Outputs
Molex 09-50-8061 (USA)
09-93-0600 (UK)
PINS: 08-52-0113
Remote Sense
Molex 22-01-2025
PINS: 08-52-0123
Artesyn Embedded Technologies Connector Kit #70-841-006, includes all of the above
WORLDWIDE OFFICES
Americas
Europe (UK)
Asia (HK)
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and
service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names,
trademarks, or registered trademarks of their respective owners. © 2016 Artesyn Embedded Technologies, Inc.
All rights reserved. For full legal terms and conditions, please visit www.artesyn.com/legal..
www.artesyn.com
For more information: www.artesyn.com/power
For support: [email protected]
LPS40 Series-DS 18Mar2016