Cross-Over Jumer-Lines 䂓Features High density and miniaturized design is achieved through using double layered conductive paste jumpers . Easy to design long cross jumpers. Cross-over jumpers allow greater cost reduction than wire jumpers. Free design capability. Copper paste jumpers for migration free wiring. Shield effect pattern design capability. 䂓Construction 㽷 㽶 㽸 㽲 㽳 No. 㽲 㽳 㽴 㽵 㽴 Name Base Copper Foil Solder Resist Insulated Layer 㽵 No. Name 㽶 㩷 Paste Jumper 㽷 㩷 Overcoat 㽸 㩷 Marking 䂓Specification Item Paste Jumper Line Ambient Temperature Range of Resistance Ag Cu Rated Current Max. Operation Voltage Breaking Voltage Insulation Resistance Solder Dipping Load Life Humidity Load Life High Temperature Humidity Ag Cu Specification Conductive Resin -30㷄䌾+100㷄 120m㱅/䂔 60m㱅/䂔 100mA/1mm Width 20V 50V DC100V 1min. >100M㱅 200m㱅/䂔 200m㱅/䂔 200m㱅/䂔 200m㱅/䂔 200m㱅/䂔 HOKURIKU Condition Silver, Copper DC50V 1min. 260㷄 5sec. 70㷄 500Hr 40㷄 90 ~ 95%RH 500Hr 100㷄 500Hr 40㷄 90 ~ 95%RH 500Hr Specifications are subject to change without notice.