2015-10-02 OSLON Compact CL Datasheet Version 1.2 LCY CEUP Compact light source with a typical luminous flux of 125 lm at 700 mA and an operation range of 50 mA up to 1000 mA Kompakte Lichtquelle mit einem typischen Lichtstrom von 125 lm bei 700 mA und einer Betriebsweite zwischen 50 mA und 1000 mA Features: • Package: Ceramic package • Technology: ThinGaN (UX:3) • Viewing angle at 50 % IV: 120° • Color: Cx = 0.57, Cy = 0.42 acc. to CIE 1931 (yellow) • ESD - withstand voltage: 8 kV acc. to ANSI/ESDA/JEDEC JS-001 (HBM, Class 3B) • Corrosion Robustness: Improved corrosion robustness • Qualifications: The product qualification test plan is based on the guidelines of AEC-Q101-REV-C, Stress Test Qualification for Automotive Grade Discrete Semiconductors. Besondere Merkmale: • Gehäusetyp: Keramikgehäuse • Technologie: ThinGaN (UX:3) • Abstrahlwinkel bei 50 % IV: 120° • Farbe: Cx = 0.57, Cy = 0.42 nach CIE 1931 (gelb) Applications • Exterior Automotive Lighting Anwendungen • Automobilbeleuchtung außen 2015-10-02 • • • 1 ESD - Festigkeit: 8 kV nach ANSI/ESDA/JEDEC JS-001 (HBM, Klasse 3B) Korrosionsstabilität: Verbesserte Korrosionsstabilität Qualifikationen: Die Produktqualifikation wurde entsprechend der Richtlinie AEC-Q101-REV-C, „Stress Test Qualification for Automotive Grade Discrete Semiconductors“, getestet. Version 1.2 LCY CEUP Ordering Information Bestellinformation Type: Luminous Flux 1) page 21 Ordering Code Typ: Lichtstrom 1) Seite 21 Bestellnummer IF = 700 mA ΦV [lm] LCY CEUP-6L6M-5F5G-8E8G Note: 125 ... 224 Q65111A7159 The above Type Numbers represent the order groups which include only a few brightness groups (see page 5). Only one group will be shipped on each packing unit (there will be no mixing of two groups on each packing unit). E. g. LCY CEUP-6L6M-5F5G-8E8G means that only one group 5M, 6L, 6M, 7L, 8L will be shippable for any packing unit. In a similar manner for colors where color chromaticity coordinate groups are measured and binned, single groups will be shipped on any one packing unit. LCY CEUP-6L6M-5F5G-8E8G means that the device will be shipped within the specified limits. In a similar manner for colors where forward voltage groups are measured and binned, single forward voltage groups will be shipped on any packing unit. E. g. LCY CEUP-6L6M-5F5G-8E8G means that only one forward voltage group 8E,8F,8G will be shippable. Anm.: Die oben genannten Typbezeichnungen umfassen die bestellbaren Selektionen. Diese bestehen aus wenigen Helligkeitsgruppen (siehe Seite 5). Es wird nur eine einzige Helligkeitsgruppe pro Verpackungseinheit geliefert. Z. B. LCY CEUP-6L6M-5F5G-8E8G bedeutet, dass in einer Verpackungseinheit nur eine der Helligkeitsgruppen 5M, 6L, 6M, 7L, 8L enhalten ist. Gleiches gilt für die Farben, bei denen Farbortgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Farbortgruppe geliefert. Z.B. LCY CEUP-6L6M-5F5G-8E8G bedeutet, dass in einer Verpackungseinheit nur eine der Farbortgruppen enthalten ist. LCY CEUP-6L6M-5F5G-8E8G bedeutet, dass das Bauteil innerhalb der spezifizierten Grenzen geliefert wird. Gleiches gilt für die LEDs, bei denen die Durchlassspannungsgruppen gemessen und gruppiert werden. Pro Verpackungseinheit wird nur eine Durchlassspannungsgruppe geliefert. Z. B. LCY CEUP-6L6M-5F5G-8E8G bedeutet, dass nach Durchlassspannungsgruppen gruppiert wird. In einer Verpackungseinheit ist nur eine der Durchlassspannungsgruppen 8E,8F,8G enthalten (siehe Seite 5). 2015-10-02 2 Version 1.2 LCY CEUP Maximum Ratings Grenzwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Operating temperature range Betriebstemperatur Top -40 ... 125 °C Storage temperature range Lagertemperatur Tstg -40 ... 125 °C Junction temperature for short time applications * Sperrschichttemperatur für Kurzzeitanwendung * Tj 175 °C Junction temperature Sperrschichttemperatur Tj 150 °C Forward current Durchlassstrom (TS = 25 °C) IF 50 ... 1000 mA Surge current Stoßstrom (t ≤ 10 µs; D = 0.005; TS = 25 °C) IFM 2000 mA Reverse voltage Sperrspannung (TS = 25 °C) VR not designed for reverse operation V ESD withstand voltage ESD Festigkeit (acc. to ANSI/ESDA/JEDEC JS-001 - HBM, Class 3B) VESD 8 kV Note: *The median lifetime (L70/B50) for Tj = 175°C is 100h. Anm: *Die mittlere Lebensdauer (L70/B50) bei Tj = 175°C beträgt 100h. 2015-10-02 3 Version 1.2 LCY CEUP Characteristics (TS = 25 °C; IF = 700 mA) Kennwerte Parameter Symbol Values Unit Bezeichnung Symbol Werte Einheit Chromaticity coordinates acc. to CIE 1931 2) page 21 Farbkoordinaten nach CIE 1931 2) Seite 21 (typ.) (typ.) Cx Cy 0.57 0.42 - Viewing angle at 50 % IV Abstrahlwinkel bei 50 % IV (typ.) 2ϕ 120 ° Forward voltage 3) page 21 Durchlassspannung 3) Seite 21 (min.) (typ.) (max.) VF VF VF 2.75 3.15 3.50 V V V IR not designed for reverse operation Reverse current Sperrstrom Real thermal resistance junction / solder point 4) page 21 (typ.) (max.) Rth JS real Rth JS real 5.7 7.3 K/W K/W Rth JS el Rth JS el 4.3 5.5 K/W K/W Realer Wärmewiderstand Sperrschicht / Lötpad 4) Seite 21 "Electrical" thermal resistance junction / solder point (typ.) 4) page 21 (max.) "Elektrischer" Wärmewiderstand Sperrschicht / Lötpad 4) Seite 21 (with efficiency ηe = 24 %) Note: Individual forward voltage groups see next page Anm.: Durchlassspannungsgruppen siehe nächste Seite 2015-10-02 4 Version 1.2 LCY CEUP Brightness Groups Helligkeitsgruppen Luminous Flux 1) page 21 Group Luminous Flux 1) page 21 Luminous Intensity 5) page 21 Lichtstrom 1) Seite 21 Lichtstrom 1) Seite 21 Lichtstärke 5) Seite 21 (min.) ΦV [lm] (max.) ΦV [lm] (typ.) IV [cd] 6L 125 140 43.7 7L 140 159 49.3 8L 159 180 55.9 5M 180 201 62.9 6M 201 224 70.1 Gruppe Forward Voltage Groups 3) page 21 Durchlassspannungsgruppen 3) Seite 21 Group Gruppe (min.) VF [V] (max.) VF [V] 8E 2.75 3.00 8F 3.00 3.25 8G 3.25 3.50 2015-10-02 5 Version 1.2 LCY CEUP Chromaticity Coordinate Groups 2) page 21 Farbortgruppen 2) Seite 21 0.9 520 530 Cy 0.8 0,45 540 510 Cy 550 0.7 0,44 560 0.6 570 500 0.5 580 590 600 610 620 630 0.4 E 0.3 490 0.2 0,42 5F 5G 480 470 460 450 0.1 0 0,43 0 0,41 LC 0,40 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Cx Cx Color Chromaticity Groups 2) page 21 Farbortgruppen 2) Seite 21 Group Gruppe 5F 2015-10-02 Cx Cy 0.5606 0.4250 0.5705 Group Gruppe Cx Cy 0.5536 0.4221 0.4289 0.5606 0.4250 0.5780 0.4080 0.5765 0.4075 0.5883 0.4111 0.5780 0.4080 5G 6 0,59 0,58 0,57 0,56 0,55 0,39 Version 1.2 LCY CEUP Group Name on Label Gruppenbezeichnung auf Etikett Example: 5M-5F-8E Beispiel: 5M-5F-8E Brightness Helligkeit Chromaticity Coordinate Farbort Forward Voltage Durchlassspannung 5M 5F 8E Note: No packing unit / tape ever contains more than one group for each selection. Anm.: In einer Verpackungseinheit / Gurt ist immer nur eine Gruppe für jede Selektion enthalten. 2015-10-02 7 Version 1.2 LCY CEUP Relative Spectral Emission - V(λ) = Standard eye response curve 5) page 21 Relative spektrale Emission - V(λ) = spektrale Augenempfindlichkeit 5) Seite 21 Φrel = f (λ); TS = 25 °C; IF = 700 mA Irel LCY CEUP 1,0 : yellow : Vλ 0,8 0,6 0,4 0,2 0,0 350 400 450 500 550 600 650 700 750 800 λ [nm] Radiation Characteristics 5) page 21 Abstrahlcharakteristik 5) Seite 21 Irel = f (ϕ); TS = 25 °C LCY CEUP ϕ [°] -10° 0° 10° -20° 20° 30° 40° 50° 60° 70° 80° 90° 1,0 -30° -40° 0,8 -50° 0,6 -60° 0,4 -70° 0,2 -80° -90° 0,0 -100° 2015-10-02 8 Irel Version 1.2 LCY CEUP Relative Luminous Flux 5) page 21 , 6) page 21 Relativer Lichtstrom 5) Seite 21 , 6) Seite 21 ΦV/ΦV(700 mA) = f(IF); TS = 25 °C Forward Current 5) page 21 , 6) page 21 Durchlassstrom 5) Seite 21 , 6) Seite 21 IF = f (VF); TS = 25 °C IF [mA] ΦV LCY CEUP 1000 LCY CEUP 1,4 ΦV(700mA) 1,2 800 1,0 0,8 600 0,6 400 0,4 0,2 200 0,0 50 2,4 2,6 2,8 3,0 3,2 3,4 3,6 3,8 Chromaticity Coordinate Shift 5) page 21 Farbortverschiebung 5) Seite 21 Cx, Cy = f(IF); TS = 25 °C LCY CEUP : Cx : Cy 0,56 0,54 0,52 0,50 0,48 0,46 0,44 0,42 0 20 0 40 0 60 0 80 00 10 IF [mA] 2015-10-02 0 40 0 60 0 80 00 10 IF [mA] VF [V] Cx Cy 0 20 9 Version 1.2 LCY CEUP Relative Forward Voltage 5) page 21 Relative Vorwärtsspannung 5) Seite 21 ΔVF = VF - VF(25 °C) = f(Tj); IF = 700 mA ∆VF [V] Relative Luminous Flux 5) page 21 Relativer Lichtstrom 5) Seite 21 ΦV/ΦV(25 °C) = f(Tj); IF = 700 mA Φv LCY CEUP 0,20 LCY CEUP 1,2 Φv(25°C) 0,15 1,0 0,10 0,8 0,05 0,00 0,6 -0,05 0,4 -0,10 0,2 -0,15 -0,20 -40 -20 0 20 40 60 0,0 -40 -20 80 100 120 Tj [°C] LCY CEUP Cx 0,58 Cy 0,56 0,54 0,52 : Cx : Cy 0,48 0,46 0,44 0,42 -40 -20 0 20 40 60 80 100 120 Tj [°C] 2015-10-02 20 40 60 80 100 120 Tj [°C] Chromaticity Coordinate Shift 5) page 21 Farbortverschiebung 5) Seite 21 Cx, Cy = f(Tj); IF = 700 mA 0,50 0 10 Version 1.2 LCY CEUP Max. Permissible Forward Current Max. zulässiger Durchlassstrom IF = f (T) IF [mA] LCY CEUP 1100 1000 900 800 700 600 : TS 500 400 300 200 Do not use below 50 mA 100 0 0 20 40 60 80 100 120 140 TS [°C] Permissible Pulse Handling Capability Zulässige Impulsbelastbarkeit IF = f(tp) D: Duty cycle, TS = 25 °C TS = 0°C ... 125°C IF [A] LCY CEUP 2,2 : D = 1.0 : D = 0.5 : D = 0.2 : D = 0.1 : D = 0.05 : D = 0.02 : D = 0.01 : D = 0.005 2,0 1,8 1,6 1,4 1,2 1,0 10-5 10-4 10 -3 0,01 0,1 1 10 Pulse time [s] 2015-10-02 11 Version 1.2 LCY CEUP Package Outline 7) page 21 Maßzeichnung 7) Seite 21 Approximate Weight: 7.8 mg Gewicht: 7.8 mg Mark: Cathode Markierung: Kathode ESD information: LED is protected by ESD device which is connected in parallel to LED-Chip. ESD Information: Die LED enthält ein ESD-Bauteil, das parallel zum Chip geschaltet ist. Corrosion robustness: Test conditions: 40 °C / 90 % rh / 15 ppm H2S / 336 h = Stricter than IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 days] = Regarding relevant gas (H2S) stricter than EN 60068-2-60 (method 4) [25 °C / 75 % rh / 200 ppb SO2, 200 ppb NO2,10 ppb Cl2 / 21 days] Korrosionsfestigkeit: Test Kondition: 40°C / 90 % rh / 15 ppm H2S / 336 h = Besser als IEC 60068-2-43 (H2S) [25°C / 75 % rh / 10 ppm H2S / 21 Tage] = Bezogen auf das Gas (H2S) besser als EN 60068-2-60 (method 4) [25°C / 75 % rh / 200ppb SO2, 200ppb NO2,10ppb Cl2 / 21 Tage] 2015-10-02 12 Version 1.2 Recommended Solder Pad 7) page 21 Empfohlenes Lötpaddesign 7) Seite 21 LCY CEUP Reflow soldering Reflow-Löten Note: For superior solder joint connectivity results we recommend soldering under standard nitrogen atmosphere. Package not suitable for ultra sonic cleaning. Anm.: Um eine verbesserte Lötstellenkontaktierung zu erreichen, empfehlen wir, unter StandardStickstoffatmosphäre zu löten. Das Gehäuse ist für Ultraschallreinigung nicht geeignet. 2015-10-02 13 Version 1.2 LCY CEUP Reflow Soldering Profile Reflow-Lötprofil Product complies to MSL Level 2 acc. to JEDEC J-STD-020D.01 OHA04525 300 ˚C T 250 Tp 245 ˚C 240 ˚C tP 217 ˚C 200 tL 150 tS 100 50 25 ˚C 0 0 50 100 150 200 s 300 250 t OHA04612 Symbol Symbol Profile Feature Profil-Charakteristik Pb-Free (SnAgCu) Assembly Minimum ) Ramp-up rate to preheat* 25 °C to 150 °C Time tS TSmin to TSmax tS 60 Ramp-up rate to peak*) TSmax to TP Recommendation Maximum 2 3 100 120 2 3 Unit Einheit K/s s K/s Liquidus temperature TL 217 Time above liquidus temperature tL 80 100 s Peak temperature TP 245 260 °C Time within 5 °C of the specified peak temperature TP - 5 K tP 20 30 s 3 6 K/s 10 Ramp-down rate* TP to 100 °C 480 Time 25 °C to TP All temperatures refer to the center of the package, measured on the top of the component * slope calculation DT/Dt: Dt max. 5 s; fulfillment for the whole T-range 2015-10-02 °C 14 s Version 1.2 LCY CEUP Taping 7) page 21 Gurtung 7) Seite 21 2015-10-02 15 Version 1.2 LCY CEUP Tape and Reel Gurtverpackung 8 mm tape with 4000 pcs. on ∅ 180 mm reel W1 D0 P0 A N F W E 13.0 ±0.25 P2 Label P1 Direction of unreeling Direction of unreeling W2 Leader: min. 400 mm * Trailer: min. 160 mm * *) Dimensions acc. to IEC 60286-3; EIA 481-D OHAY0324 Tape dimensions [mm] Gurtmaße [mm] Tape dim ensions in m m W P0 P1 P2 D0 E F 8 + 0.3 / -0.1 4 ± 0.1 2 ± 0.05 or 4 ± 0.1 2 ± 0.05 1.5 ± 0.1 1.75 ± 0.1 3.5 ± 0.05 Reel dimensions [mm] Rollenmaße [mm] Reel dim ensions in m m A W Nmin W1 W2max 180 8 60 8.4 + 2 14.4 2015-10-02 16 Version 1.2 LCY CEUP Barcode-Product-Label (BPL) Barcode-Produkt-Etikett (BPL) OSRAM Opto EX A RoHS Compliant (6P) BATCH NO: 1234567890 (1T) LOT NO: 1234567890 BIN1: XX-XX-X-XXX-X LX XXXX Semiconductors MP ML Temp ST X XXX °C X (9D) D/C: 1234 Pack: RXX LE DEMY XXX X_X123_1234.1234 X (X) PROD NO: 123456789(Q)QTY: 9999 (G) GROUP: XX-XX-X-X OHA04563 Dry Packing Process and Materials Trockenverpackung und Materialien Moisture-sensitive label or print L VE el LE see . lab e H) nk, (R bla cod If y bar . dit RH mi % hu e /60 ve ed ag ˚C ati rar ck rel 30 s VE RS _ < inf pa % ainITI TO of to ak 90 urs d nt ). < ns (pe or urs d co NSUC Ho de , cte itio urs g SEND Ho an bje ing co ˚C 72 nd Ho urs 5 baRE CO te 48 ˚C su ss e Ho co ± ce is 24 6 da e y MI 40 be tim ˚C e ThISTU th < tor ll pro tim SE or ). 23 tim e at t wi nt˚C or l wi fac MO Flo tim s TO at or ca at re. Flo d tha ale el or nth OP nti Flo uiv du if: rea es l 4 5 Flo lab mo ide ce eq low g, l ve vic is be or de 24 tin en l 5a6 pro ve Le de , e te co , g: ve l un wh Le ke r se da ve % ure ba ed low ba Le mo ba e al d ure Le ist en ref e e 10 tim ure se for ist ale op se for > , Mo se 3 ist ure is or . , is ha se Mo nk be ist nk rd g -03 Mo in n Flo r-p RH g, bla Mo ba TD po If blathi % kin Ca life s (if ar t. wi 10 ba tor J-S thi, va p. elf Ye ar ks _ < e icat me , C 1 Ye ee urs Sh terlow tem ted at ed uir > 1 W Ho un Af Indno uir DE 1. d e 4 8 ref dy reqy is 2. JE bo e Mo ore tim 16 req : C/ e es dit2b a) St tim or mi IP ed or g is tim e vic b) or e Hu Flo en tim or De 2a kin nc te Flo a) op or 3. b) baere Flo da e l 1 2 Flo If al ref tim ve l 4. se d l 2a3 ve Le g an ve l Le Ba te ure Le ve ure Le ist Da ure ist Mo ist ure Mo ist Mo Mo Barcode label N TIO U A C M RA OS Humidity indicator Barcode label Please check the HIC immidiately after bag opening. Discard if circles overrun. Avoid metal contact. Do not eat. Comparator check dot WET If wet, examine units, if necessary bake units 15% If wet, examine units, if necessary bake units 10% 5% If wet, parts still adequately dry. change desiccant Humidity Indicator MIL-I-8835 AM OSR Desiccant OHA00539 Note: Moisture-sensitive product is packed in a dry bag containing desiccant and a humidity card. Regarding dry pack you will find further information in the internet and in the Short Form Catalog in chapter “Tape and Reel” under the topic “Dry Pack”. Here you will also find the normative references like JEDEC. Anm.: Feuchteempfindliche Produkte sind verpackt in einem Trockenbeutel zusammen mit einem Trockenmittel und einer Feuchteindikatorkarte. Bezüglich Trockenverpackung finden Sie weitere Hinweise im Internet und in unserem Short Form Catalog im Kapitel “Gurtung und Verpackung” unter dem Punkt “Trockenverpackung”. Hier sind Normenbezüge, unter anderem ein Auszug der JEDEC-Norm, enthalten. 2015-10-02 17 Version 1.2 LCY CEUP Transportation Packing and Materials Kartonverpackung und Materialien Barcode label 8 Y M DE R 18 -1 Q P -1 + P: C: 99 D/ 21 00 (9 D) 21 : 20 00 : 14 2 5 (Q )Q TY O H 12 34 S S em R ic AM on du O p ct to or H NO s TC 3G BA (6 P) NO : 12 11 00 LO T (1 T) NO : OD PR ) (X 44 (G ) G RO UP : P -1 + Q -1 R 18 DE M Y Bi n2 : Pn3 : Q 1: -1 20 M -2 2 L 0 Te 2a 22 m 3 24 0 p ST Ad 26 0 C R C R0 ditio 0 C R PA 77 na RT l TE CK VA XT R: M u L lt S iT Y O T P 67 L 6 E Bi D Bi n1 D) (9 : 20 00 D/ C: 01 Muster TY )Q : 34 : NO O PR (X ) Packing Sealing label Dimensions of transportation box in mm Width Length Height Breite Länge Höhe 200 ± 5 195 ± 5 30 ± 5 2015-10-02 M RA OS D 5 14 2 110 0 (Q O S TC (1 T) LO T NO (6 P) : 12 BA S 8 3G em R ic AM o n O d u p ct to o H rs NO 2199 H 12 2100 01 44 el A C OU L GR E V LE see . lab e H) nk, cod (R bla r If ty ba . idi RH m hu 0% e /6 ive d ˚C re ag lat ra ck re 30 _ < inf pa % k s of to 90 ea ur s d ). < ns (p or ur s d Ho de , cteg itio ur s Ho an bje co ˚C 72 sin nd Ho ur 5 te 48 ˚C su es e Ho IC co ± is UR 24 6 da e M 40 be oc ry tim ˚C e Th STSE r th < ll pr tim cto ). r OI oo 23 wi nt tim e at l wi fa r M TO Fl oo tim s at at ale ˚C at e. ica Fl th oo r th ur el OP nt Fl oo on es uiv if: read ed l 4 5 Fl , lab m ide eq low l oc ve vic is ingen be or de 24 l 5a6 pr ve Le de nt wh e te co , w, g: ve l Le ke r re ou se da ba ed flo Le ve tu re m % ba e ba al d Le r en re tu re e re 10 ois tim se fo tu re ale op se fo > , M r se ois 3 is , is ha se M ois tu nk be oo . 03 nk rd g M ois in r-p bla in Fl RH g, DM ba po If blath % kin Ca life is (if . ar ST p. wi 10 baator et Jelf r th va Ye ar ks s m _ < m ed 1 Ye ee ur d, C iredic t Sh te w, te at nt > 1 W Ho Af flody qu In no ire DE 1. e 4 8 ou re ed re ty is qu JE 2. bo e M or tim 16 re C/ : e es idi 2b r a) St tim mor is IP ed r oo tim e vic b) g e r Hu Fl en oo tim De 2a kin nc te Fl oo r a) op 3. b) ba re Fl oo da e fe l 1 2 Fl If al re tim ve l 4. se d l 2a3 ve Le g an ve l Le re Ba te Le ve tu re Le tu Da ois re tu re M ois M ois tu M ois M Nns IVEORS ai IT CT nt TIO co NS DU g SE U ba E ON (G ) M u L lt S iT Y O T67 P L 6 Muster E Bi D Bi n1 Bi n2 : Pn3 : Q- 1: 1- 20 M 20 2 L Te 2a 22 m 3 24 0 p ST Ad 26 0 C R 0 C R0 dit ion C R PA 77 al RT CK TE VA XT R: Barcode label 18 OHA02044 Version 1.2 LCY CEUP Notes Hinweise The evaluation of eye safety occurs according to the standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Within the risk grouping system of this CIE standard, the LED specified in this data sheet fall into the class Exempt group (exposure time 10000 s). Under real circumstances (for exposure time, eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices. As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even accidents, depending on the situation. Die Bewertung der Augensicherheit erfolgt nach dem Standard IEC 62471:2008 ("photobiological safety of lamps and lamp systems"). Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LEDs folgende Gruppenanforderung - Exempt group (Expositionsdauer 10000 s). Unter realen Umständen (für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefährdung aus. Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres Gefahrenpotenzial besitzen. Nach einem Blick in eine helle Lichtquelle (z.B. Autoscheinwerfer), kann ein temporär eingeschränktes Sehvermögen oder auch Nachbilder zu Irritationen, Belästigungen, Beeinträchtigungen oder sogar Unfällen führen. Subcomponents of this LED contain, among other substances, goldplated and Ag-filled materials. In spite of the improved corrosion stability of this LED, it can be affected by environments that contain very high concentrations of aggressive substances. Therefore, we recommend avoiding aggressive atmospheres during storage, production and use. Einzelkomponenten dieser LED enthalten u.a. goldbeschichtete und Ag-gefüllte Materialien. Trotz der verbesserten Korrosionsstabilität dieser LED können Einzelkomponenten durch sehr hohe Konzentration aggressiver Substanzen angegriffen werden. Aus diesem Grund wird empfohlen, aggressive Umgebungen während der Lagerung, Produktion und im Betrieb zu vermeiden. For further application related informations please visit www.osram-os.com/appnotes Für weitere applikationsspezifische Informationen besuchen Sie bitte www.osram-os.com/appnotes 2015-10-02 19 Version 1.2 LCY CEUP Disclaimer Disclaimer Language english will prevail in case of any discrepancies or deviations between the two language wordings. Bei abweichenden Angaben im zweisprachigen Wortlaut haben die Angaben in englischer Sprache Vorrang. Attention please! The information describes the type of component and shall not be considered as assured characteristics. Terms of delivery and rights to change design reserved. Due to technical requirements components may contain dangerous substances. For information on the types in question please contact our Sales Organization. If printed or downloaded, please find the latest version in the Internet. Packing Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office. By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs incurred. Components used in life-support devices or systems must be expressly authorized for such purpose! Critical components* may only be used in life-support devices** or systems with the express written approval of OSRAM OS. Bitte beachten! Lieferbedingungen und Änderungen im Design vorbehalten. Aufgrund technischer Anforderungen können die Bauteile Gefahrstoffe enthalten. Für weitere Informationen zu gewünschten Bauteilen, wenden Sie sich bitte an unseren Vertrieb. Falls Sie dieses Datenblatt ausgedruckt oder heruntergeladen haben, finden Sie die aktuellste Version im Internet. Verpackung Benutzen Sie bitte die Ihnen bekannten Recyclingwege. Wenn diese nicht bekannt sein sollten, wenden Sie sich bitte an das nächstgelegene Vertriebsbüro. Wir nehmen das Verpackungsmaterial zurück, falls dies vereinbart wurde und das Material sortiert ist. Sie tragen die Transportkosten. Für Verpackungsmaterial, das unsortiert an uns zurückgeschickt wird oder das wir nicht annehmen müssen, stellen wir Ihnen die anfallenden Kosten in Rechnung. Bauteile, die in lebenserhaltenden Apparaten und Systemen eingesetzt werden, müssen für diese Zwecke ausdrücklich zugelassen sein! Kritische Bauteile* dürfen in lebenserhaltenden Apparaten und Systemen** nur dann eingesetzt werden, wenn ein schriftliches Einverständnis von OSRAM OS vorliegt. *) A critical component is a component used in a life-support device or system whose failure can reasonably be expected to cause the failure of that life-support device or system, or to affect its safety or the effectiveness of that device or system. **) Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail, it is reasonable to assume that the health and the life of the user may be endangered. 2015-10-02 *) Ein kritisches Bauteil ist ein Bauteil, das in lebenserhaltenden Apparaten oder Systemen eingesetzt wird und dessen Defekt voraussichtlich zu einer Fehlfunktion dieses lebenserhaltenden Apparates oder Systems führen wird oder die Sicherheit oder Effektivität dieses Apparates oder Systems beeinträchtigt. **) Lebenserhaltende Apparate oder Systeme sind für (a) die Implantierung in den menschlichen Körper oder (b) für die Lebenserhaltung bestimmt. Falls Sie versagen, kann davon ausgegangen werden, dass die Gesundheit und das Leben des Patienten in Gefahr ist. 20 Version 1.2 LCY CEUP Glossary Glossar 1) Brightness: Brightness values are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 8 % and an expanded uncertainty of ± 11 % (acc. to GUM with a coverage factor of k = 3). 1) Helligkeit: Helligkeitswerte werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 8 % und einer erweiterten Messunsicherheit von ± 11 % gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 2) Chromaticity coordinate groups: Chromaticity coordinates are measured during a current pulse of typically 25 ms, with an internal reproducibility of ± 0.005 and an expanded uncertainty of ± 0.01 (acc. to GUM with a coverage factor of k = 3). 2) Farbortgruppen: Farbkoordinaten werden während eines Strompulses einer typischen Dauer von 25 ms, mit einer internen Reproduzierbarkeit von ± 0,005 und einer erweiterten Messunsicherheit von ± 0,01 gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 3) Forward Voltage: The forward voltage is measured during a current pulse of typically 8 ms, with an internal reproducibility of ± 0.05 V and an expanded uncertainty of ± 0.1 V (acc. to GUM with a coverage factor of k = 3). 3) Durchlassspannung: Vorwärtsspannungen werden während eines Strompulses einer typischen Dauer von 8 ms, mit einer internen Reproduzierbarkeit von ± 0,05 V und einer erweiterten Messunsicherheit von ± 0,1 V gemessen (gemäß GUM mit Erweiterungsfaktor k = 3). 4) Thermal Resistance: Rth max is based on statistic values (6σ). 4) Wärmewiderstand: Rth statistischen Werten (6σ). 5) Typical Values: Due to the special conditions of the manufacturing processes of LED, the typical data or calculated correlations of technical parameters can only reflect statistical figures. These do not necessarily correspond to the actual parameters of each single product, which could differ from the typical data and calculated correlations or the typical characteristic line. If requested, e.g. because of technical improvements, these typ. data will be changed without any further notice. 5) Typische Werte: Wegen der besonderen Prozessbedingungen bei der Herstellung von LED können typische oder abgeleitete technische Parameter nur aufgrund statistischer Werte wiedergegeben werden. Diese stimmen nicht notwendigerweise mit den Werten jedes einzelnen Produktes überein, dessen Werte sich von typischen und abgeleiteten Werten oder typischen Kennlinien unterscheiden können. Falls erforderlich, z.B. aufgrund technischer Verbesserungen, werden diese typischen Werte ohne weitere Ankündigung geändert. 6) Characteristic curve: In the range where the line of the graph is broken, you must expect higher differences between single LEDs within one packing unit. 6) Kennlinien: Im gestrichelten Bereich der Kennlinien muss mit erhöhten Abweichungen zwischen Leuchtdioden innerhalb einer Verpackungseinheit gerechnet werden. 7) Tolerance of Measure: Unless otherwise noted in drawing, tolerances are specified with ±0.1 and dimensions are specified in mm. 7) Maßtoleranz: Wenn in der Zeichnung nicht anders angegeben, gilt eine Toleranz von ±0,1. Maße werden in mm angegeben. 2015-10-02 21 max basiert auf Version 1.2 LCY CEUP Published by OSRAM Opto Semiconductors GmbH Leibnizstraße 4, D-93055 Regensburg www.osram-os.com © All Rights Reserved. 2015-10-02 22