GLENAIR M85049-2-24C Strain relief Datasheet

Strain
Reliefs
AS85049/2 and MS3057C
Strain Reliefs
M85049/2-12C
MIL-DTL-5015
MS ”V” Thread
(Mates to General
Duty ‘A’ Endbell)
Dash No.
Basic Part No.
SUPERCEDED SPECIFICATION
MS3057-16C
Dash No.
Basic Part No.
Clamping
Bars
F
H (See
Note 3)
E Thread
Cable
Entry
G
TABLE I
Dash
No.
3C
4C
6C
8C
10C
12C
16C
20C
24C
28C
32C
E Thread
Conn. Shell
Class 2B
Ref.(s)
1/2 - 28 UNEF
8S, 10S
5/8 - 24 UNEF
10SL, 12S, 12
3/4 - 20 UNEF
14S, 14
7/8 - 20 UNEF
16S, 16
1 - 20 UNEF
18
1 3/16 - 18 UNEF
20, 22
1 7/16 - 18 UNEF
24, 28
1 3/4 - 18 UNS
32
2 - 18 UNS
36
2 1/4 - 16 UN
40
2 1/2 - 16 UN
44
F
Max
1.375 (34.9)
1.375 (34.9)
1.375 (34.9)
1.375 (34.9)
1.437 (36.5)
1.437 (36.5)
1.562 (39.7)
1.812 (46.0)
2.062 (52.4)
2.062 (52.4)
2.188 (55.6)
G Dia
Max
.812 (20.6)
.937 (23.8)
1.062 (27.0)
1.188 (30.2)
1.312 (33.3)
1.562 (39.7)
1.750 (44.5)
2.250 (57.2)
2.375 (60.3)
2.625 (66.7)
2.812 (71.4)
H Max
Closed
.217 (5.5)
.296 (7.5)
.390 (9.9)
.434 (11.0)
.434 (11.0)
.596 (15.1)
.596 (15.1)
.858 (21.8)
.858 (21.8)
1.107 (28.1)
1.421 (36.1)
Cable Entry
Max
.219 (5.6)
.312 (7.9)
.438 (11.1)
.531 (13.5)
.625 (15.9)
.750 (19.1)
.938 (23.8)
1.250 (31.8)
1.375 (34.9)
1.625 (41.3)
1.875 (47.6)
1. For complete dimensions see applicable Military Specification.
2. Metric dimensions (mm) are indicated in parentheses.
3. Cable Entry is defined as the accomodation entry for the wire bundle or cable. Dimensions are not
intended for inspection criteria.
4. Finish on M85049/2 is cadmium olive drab over electroless nickel (1,000 hour salt spray).
© 2005 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
E-Mail: [email protected]
62-10