Power Systems CRS-2415M Dc-dc converter unit 3w regulated dc-dc converter Datasheet

DC-DC Converter UNIT
CR Series ( 3W REGULATED DC-DC CONVERTER)
FEATURES
z
z
z
z
1000VDC ISOLATION
HIGH EFFICIENCY
SIX-SIDED SHIELD TO REDUCE
EMI
LOW COST
NO EXTERNAL COMPONENTS
REQUIRED
UP TO 3W REGULATED OUTPUT
POWER
DUAL IN LINE PACKAGE
100% BURNED IN
LOW NOISE
MTBF > 850,000 HOURS
z
OUTPUT SPECIFICATIONS
z
z
z
z
z
z
z
Voltage Setpoint Accuracy
+/-2% max
Temperature Coefficient
+/-0.03%/ C
O
Ripple & Noise (20MHz
INPUT SPECIFICATIONS
Input Voltage Range
+/-10% max
Input Filter
Pi Network
100mVp-p max
BW)
Line Regulation1
Load Regulation
+/-0.5% max
2
+/-0.5% max
Short Circuit Protection
Current Limit
z
GENERAL SPECIFICATIONS
Efficiency
58% min
Protection
Short Circuit Restart
z
Automatic
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature
Storage Temperature
Cooling
Isolation Voltage3
Isolation Resistance
-25 OC to +71 OC
Switching Frequency
50 KHz min
-55 OC to +125 OC
Isolation Capacitance
80pF max
Free-Air Convection
MTBF
Weight
ALL SPECIFICATIONS TYPICAL AT NOMINAL
LINE,
FULL
LOAD
,
AND
OTHERWISE NOTED.
25
O
C
Case Material
UNLESS
850,000 Hours
12.0g-14.4g
Non-Conductive Plastic
Or Six-Sided Shield Case
Case Size
1
High Line to Low Line.
2
Load Regulation is for output load current change from 10% to 100%.
3
For 60 seconds
www.Power-Systems.de
1000 VDC min
9
10 ohms min
Page: 1 / 5
31.8mm*20.3mm*10.2mm
Version: 4-Oct-02
DC-DC Converter UNIT
CR Series ( 3W REGULATED DC-DC CONVERTER)
z SELECTION GUIDE
INPUT
MODEL
NUMBER
4
OUTPUT
OUTPUT
VOLTAGE VOLTAGE CURRENT
(VDC)
(VDC)
(mA)
INPUT
CURRENT(mA)
EFF
ISOLATION
FULL
NO
(%)
(VDC)
LOAD
LOAD
CRS-0505(M)
4.5-5.5
5
600
960
70
63
1000
CRS-0509(M)
4.5-5.5
9
330
950
70
63
1000
CRS-0512(M)
4.5-5.5
12
250
930
70
65
1000
CRS-0515(M)
4.5-5.5
15
200
940
70
64
1000
CRS-0524(M)
4.5-5.5
24
125
940
70
64
1000
CRD-0505(M)
4.5-5.5
+/-5
+/-300
970
70
62
1000
CRD-0512(M)
4.5-5.5
+/-12
+/-125
930
70
65
1000
CRD-0515(M)
4.5-5.5
+/-15
+/-100
940
70
64
1000
CRS-1205(M)
10.8-13.2
5
600
410
30
61
1000
CRS-1209(M)
10.8-13.2
9
330
400
30
63
1000
CRS-1212(M)
10.8-13.2
12
250
380
30
66
1000
CRS-1215(M)
10.8-13.2
15
200
360
30
69
1000
CRS-1224(M)
10.8-13.2
24
125
360
30
69
1000
CRD-1205(M)
10.8-13.2
+/-5
+/-300
420
30
60
1000
CRD-1212(M)
10.8-13.2
+/-12
+/-125
390
30
64
1000
CRD-1215(M)
10.8-13.2
+/-15
+/-100
360
30
69
1000
CRS-2405(M)
21.6-26.4
5
600
200
15
63
1000
CRS-2409(M)
21.6-26.4
9
330
190
15
66
1000
CRS-2412(M)
21.6-26.4
12
250
180
15
69
1000
CRS-2415(M)
21.6-26.4
15
200
180
15
69
1000
CRS-2424(M)
21.6-26.4
24
125
180
15
69
1000
CRD-2405(M)
21.6-26.4
+/-5
+/-300
210
15
60
1000
CRD-2412(M)
21.6-26.4
+/-12
+/-125
194
26
64
1000
CRD-2415(M)
21.6-26.4
+/-15
+/-100
180
15
69
1000
CRS-4805(M)
43.2-52.8
5
600
100
10
63
1000
CRS-4809(M)
43.2-52.8
9
330
95
10
66
1000
CRS-4812(M)
43.2-52.8
12
250
90
10
69
1000
CRS-4815(M)
43.2-52.8
15
200
90
10
69
1000
CRD-4805(M)
43.2-52.8
+/-5
+/-300
100
10
63
1000
CRD-4812(M)
43.2-52.8
+/-12
+/-125
90
10
69
1000
CRD-4815(M)
43.2-52.8
+/-15
+/-100
90
10
69
1000
Note: Other input to output voltages may be available. Please contact factory.
4
CR*-****
------ Non-Conductive Plastic
www.Power-Systems.de
CR*-****M ------ Six -sided shield case
Page: 2 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CR Series ( 3W REGULATED DC-DC CONVERTER)
z SIMPLIFIED SCHEMATIC
SINGLE OUTPUT
+Vin
REGULATOR
DUAL OUTPUT
+Vout
OSCILLATOR
DRIVER
-Vin
REGULATOR
+Vin
OSCILLATOR
DRIVER
-Vout
+Vout
Com.
-Vout
-Vin
REGULATOR
z MECHANICAL DIMENSIONS &
RECOMMENDED FOOTPRINT DETAILS
www.Power-Systems.de
Page: 3 / 5
PIN
SINGLE
DUAL
1 & 24
+Vin
+Vin
2 & 23
NC
-Vout
3 & 22
NC
Common
10 & 15
-Vout
Common
11 & 14
+Vout
+Vout
12 & 13
-Vin
-Vin
Version: 4-Oct-02
DC-DC Converter UNIT
CR Series ( 3W REGULATED DC-DC CONVERTER)
z TYPICAL APPLICATIONS
SINGLE OUTPUT
INPUT
DUAL OUTPUT
OUTPUT
INPUT
OUTPUT
+Vout
+Vin
+Vin
+Vout
LOAD1
LOAD
DC-DC
CONVERTER
-Vin
Common
DC-DC
CONVERTER
-Vin
-Vout
LOAD2
-Vout
z TYPICAL PERFORMANCE CUREVES
Specifications typical at ta=25 OC,nominal input voltage , rated output current unless otherwise specified.
OUTPUT LOAD vs EFFICIENCY
OUTPUT LOAD vs OUTPUT VOLTAGE
OUTPUT VOLTAGE
CHANGE(%)
EFFICIENCY(%)
80%
60%
SAFE
OPERATING
AREA
40%
20%
0%
0%
20%
40%
60%
80%
10%
5%
0%
-5%
-10%
100%
0%
OUTPUT LOAD(%)
40%
60%
80% 100%
OUTPUT LOAD(%)
TEMPERATURE DERATING
INPUT VOLTAGE vs EFFICIENCY
100%
EFFICIENCY(%)
4.0
OUTPUT POWER(W)
20%
3.0
2.0
1.0
80%
60%
40%
20%
0%
0.0
-25
0
25
50
70
-10
100
Nom
5
10
INPUT VOLTAGE(%)
TA(degree C)
www.Power-Systems.de
-5
Page: 4 / 5
Version: 4-Oct-02
DC-DC Converter UNIT
CR Series ( 3W REGULATED DC-DC CONVERTER)
CR SERIES APPLICATION NOTES:
EXTERNAL CAPACITANCE REQUIREMENTS:
No external capacitance is required for operation of the CR series.
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm
from DC to 100KHz is required.
External output capacitance is not required for operation, however it is recommended that 10uF
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.
Additional output capacitance may be added for increased filtering, but should not exceed 220uF.
Negative Outputs:
A negative output voltage may be obtained by connecting the +OUT to circuit ground and
connecting –OUT as the negative output.
FOR MORE INFORMATION CALL:
Power Systems – The Power Solution
Ilsfeld-Auenstein ( Germany ) Dörnet 8
Tel: + 49 / 70 62 / 67 59 – 6
E-mail: [email protected]
Home Page: www.Power-Systems.de
www.Power-Systems.de
Page: 5 / 5
Fax: + 49 / 70 62 / 67 59 -80
Version: 4-Oct-02
Similar pages