Keysight Technologies E5080A ENA Series Network Analyzer - 9 kHz to 4.5/6.5/9 GHz E5092A Configurable Multiport Test Set Data Sheet 02 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Options This document provides technical specifications for the E5080A ENA network analyzer. E5080A-245 E5080A-265 E5080A-295 E5080A-445 E5080A-465 E5080A-495 2-port test set, 9 kHz to 4.5 GHz, with bias tees 2-port test set, 9 kHz to 6.5 GHz, with bias tees 2-port test set, 9 kHz to 9 GHz, with bias tees 4-port test set, 9 kHz to 4.5 GHz, with bias tees 4-port test set, 9 kHz to 6.5 GHz, with bias tees 4-port test set, 9 kHz to 9 GHz, with bias tees Calibration kits and ECal modules This E5080A data sheet also provides technical specifications for the following calibration kits and ECal modules. For models not listed in this data sheet, please download the free Uncertainty Calculator from (http://www.keysight.com/find/na_ calculator)to generate the curves for your calibration kit and enable ENA setup. 85032F 85033E 85092C 85093C Calibration kit Calibration kit Electronic calibration (ECal) module Electronic calibration (ECal) module Definitions Specification (spec.): Warranted performance. All specifications apply at 25 ºC (± 5 ºC), unless otherwise stated, and 90 minutes after the instrument has been turned on. Specifications include guard bands to account for the expected statistical performance distribution, measurement uncertainties, and changes in performance due to environmental conditions. Typical (typ.): Expected performance of an average unit which does not include guardbands. It is not covered by the product warranty. General characteristics: A general, descriptive term that does not imply a level of performance. 03 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Corrected System Performance The specifications in this section apply to measurements made with the Keysight E5080A network analyzer under the following conditions: –– No averaging applied to data –– Environmental temperature of 23 °C (± 3 °C) with less than 1 °C deviation from the calibration temperature –– Response and isolation calibration performed System dynamic range 1 9 k to 100 kHz 100 k to 50 MHz 50 M to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Specification (10 Hz IFBW) Typical (3 Hz IFBW) 120 dB 129 dB 135 dB 132 dB 120 dB 137 dB 146 dB 152 dB 145 dB 135 dB System dynamic range (specification and actual measurement data example) 1. The test port dynamic range is calculated as the difference between the test port rms noise floor and the source maximum output power. The effective dynamic range must take measurement uncertainty and interfering signals into account. 04 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Corrected System Performance with Calibration Kit Corrected system performance with type-N device connectors, 85032F calibration kit Network analyzer : E5080A Calibration kit : 85032F (Type-N, 50 Ω) Calibration : full 2-port IF bandwidth = 10 Hz, no averaging applied to data, environmental temperature = 23 °C (± 3 °C) with < 1 °C deviation from calibration temperature, isolation calibration performed Specification Description 9 k to 300 kHz 300 k to 10 MHz 10 M to 3 GHz 3 G to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Directivity 49 49 46 40 38 38 Source match 41 41 40 36 35 35 Load match 48 49 46 40 37 36 Reflection tracking ± 0.011 ± 0.011 ± 0.021 ± 0.032 ± 0.054 ± 0.054 Transmission tracking ± 0.045 ± 0.015 ± 0.018 ± 0.056 ± 0.088 ± 0.113 Transmission uncertainty (Specification)1 Reflection uncertainty (Specification)1 1. Applies to the units with Serial Number Prefix MY552/SG552 and above 05 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Corrected system performance with type-N device connectors, 85092C electronic calibration (ECal) module Network analyzer : E5080A Calibration kit : 85092C (Type-N, 50 Ω) Electronic calibration (ECal) module Calibration : full 2-port IF bandwidth = 10 Hz, no averaging applied to data, environmental temperature = 23 °C (± 3 °C) with < 1 °C deviation from calibration temperature , isolation calibration is not performed Specification Description 9 k to 300 kHz 300 k to 10 MHz 10 M to 3 GHz 3 G to 6 GHz 6 G to 8.5 GHz Directivity 45 52 49 45 45 Source match 36 44 41 36 36 Load match 37 47 44 38 38 Reflection tracking ± 0.1 ± 0.04 ± 0.06 ± 0.07 ± 0.07 Transmission tracking ± 0.082 ± 0.028 ± 0.053 ± 0.157 ± 0.167 Transmission uncertainty (Specification)1 Reflection uncertainty (Specification)1 1. Applies to the units with Serial Number Prefix MY552/SG552 and above 06 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Corrected system performance with 3.5 mm device connector type, 85033E calibration kit Network analyzer : E5080A Calibration kit : 85033E (3.5 mm, 50 Ω) Calibration : full 2-port IF bandwidth = 10 Hz, no averaging applied to data, environmental temperature = 23 °C (± 3 °C) with < 1 °C deviation from calibration temperature, isolation calibration performed Specification Description 9 k to 300 kHz 300 k to 10 MHz 10 M to 3 GHz 3 G to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Directivity 46 46 44 38 38 38 Source match 43 43 40 37 36 36 Load match 46 46 44 38 38 38 Reflection tracking ± 0.006 ± 0.006 ± 0.007 ± 0.009 ± 0.010 ± 0.010 Transmission tracking ± 0.043 ± 0.015 ± 0.020 ± 0.058 ± 0.079 ± 0.099 Transmission uncertainty (Specification)1 Reflection uncertainty (Specification)1 1. Applies to the units with Serial Number Prefix MY552/SG552 and above 07 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Corrected system performance with 3.5 mm device connector type, 85093C electronic calibration (ECal) module Network analyzer : E5080A Calibration kit : 85093C (3.5 mm, 50 Ω) Electronic calibration (ECal) module Calibration : full 2-port IF bandwidth = 10 Hz, no averaging applied to data, environmental temperature = 23 °C (± 3 °C) with < 1 °C deviation from calibration temperature , isolation calibration is not performed Specification Description 300 k to 10 MHz 10 M to 3 GHz 3 G to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Directivity 45 52 50 47 47 Source match 36 44 39 34 34 Load match 37 47 44 40 39 Reflection tracking ± 0.1 ± 0.04 ± 0.05 ± 0.07 ± 0.07 Transmission tracking ± 0.086 ± 0.025 ± 0.049 ± 0.143 ± 0.152 Transmission uncertainty (Specification)1 Reflection uncertainty (Specification)1 1. Applies to the units with Serial Number Prefix MY552/SG552 and above 08 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Uncorrected System Performance User correction: OFF, system error correction: ON Specification Description 9 k to 50 kHz 50 k to 300 kHz 300 k to3 GHz 3 G to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Directivity 20 20 25 20 15 15 Source match 20 20 25 20 15 15 Load match 8 12 17 12 10 8 Typical Description 9 k to 50 kHz 50 k to 300 kHz 300 k to3 GHz 3 G to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Directivity 40 40 40 35 35 35 Source match 40 40 40 35 35 35 Load match 12 18 20 20 16 14 Transmission tracking ± 0.1 ± 0.1 ± 0.1 ± 0.1 ± 0.2 ± 0.2 Reflection tracking ± 0.1 ± 0.1 ± 0.1 ± 0.1 ± 0.2 ± 0.2 Typical Description 9 k to 100 kHz 100 k to 50 MHz 50 M to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz Crosstalk 132 141 147 140 130 Test Port Output (Source) Test port output frequency Description Specification Frequency range Option 245, 445 Option 265, 465 Option 295, 495 9 k to 4.5 GHz 9 k to 6.5 GHz 9 k to 9 GHz Resolution 1 Hz CW accuracy Standard Option 1E5 ± 7 ppm (23 ± 3 ºC) ± 0.45 ppm Source stability Standard Option 1E5 Typical ± 3.0 ppm (25 ± 5 ºC) ± 7 ppm (0 to 40 ºC) ± 0.05 ppm (0 to 40 ºC) ± 0.4 ppm/year 09 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Test port output power 1 Description Specification Nominal power (preset power) 0 dBm Range 9 k to 100 kHz 100 k to 50 MHz 50 M to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz —90 to 10 dBm —90 to 12 dBm —90 to 15 dBm —90 to 12 dBm —90 to 8 dBm —110 to 12 dBm —110 to 14 dBm —110 to 17 dBm —110 to 14 dBm —110 to 12 dBm Max leveled power 9 k to 100 kHz 100 k to 50 MHz 50 M to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz 10 dBm 12 dBm 15 dBm 12 dBm 8 dBm 12 dBm 14 dBm 17 dBm 14 dBm 12 dBm Resolution 0.01 dB Level accuracy Sweep type: stepped 9 k to 50 kHz 50 k to 9 GHz Sweep type: auto 9 k to 9 GHz ± 2.0 dB ± 1.5 dB Level linearity —20 dBm to maximum power Sweep type: stepped Sweep type: auto —110 dBm to —20 dBm ± 0.75 dB Typical 2 Power sweep range 9 k to 100 kHz 100 k to 50 MHz 50 M to 6GHz 6 G to 8.5 GHz 8.5 G to 9 GHz ± 2.0 dB ± 1.0 dB ± 1.0 dB —90 to 10 dBm —90 to 12 dBm —90 to 15 dBm —90 to 12 dBm —90 to 8 dBm Test port output signal purity Description Specification Typical Harmonics (2nd or 3rd) (at 0 dBm) 9 k to 2 GHz 2 G to 9 GHz < –25 dBc < –20 dBc Non-harmonic spurious (at 0 dBm) < -30 dBc 1. Source output performance on all ports. 2. Power calibration using an external power meter improves level accuracy of the test port output power. 3. Level linearity given is relative to 0 dBm. 10 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Test Port Input Description Specification +27 dBm or ± 35 VDC Damage Level Test port noise floor 9 k to 100 kHz 100 k to 50 MHz 50 M to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz 1 Compression level (@+10dBm input) Magnitude 9 k to 6 GHz 6 G to 9 GHz Phase 9 k to 6 GHz 6 G to 9 GHz 0.1 dB compression input level 9 k to 100 k 100 k to 50 MHz 50 M to 6 GHz 6 G to 8.5 GHz 8.5 G to 9 GHz 1. Typical IFBW=1 Hz, FOM is off. —120 dBm —127 dBm —130 dBm —130 dBm —122 dBm —130 dBm —137 dBm —140 dBm —136 dBm —128 dBm 0.207 dB 0.207 dB 0.04 dB 0.08 dB 0.503 deg 0.503 deg 0.3 deg 0.6 deg 10 dBm 12 dBm 15 dBm 12 dBm 10 dBm 11 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Trace noise Description Specification Typical 0.003 dBrms 0.0015 dBrms 0.0015 dBrms 0.002 dBrms 0.001 dBrms 0.0005dBrms 0.0005 dBrms 0.0006 dBrms 0.004 dBrms 0.003 dBrms 0.003 dBrms 0.0015 dBrms 0.002 dBrms 0.002 dBrms 0.001 dBrms 0.001 dBrms 0.0005 dBrms 0.0006 dBrms 0.03 degrms 0.02 degrms 0.01 degrms 0.01 degrms 0.02 degrms 0.015 degrms 0.008 degrms 0.003 degrms 0.003 degrms 0.006 degrms 0.06 degrms 0.035 degrms 0.02 degrms 0.02 degrms 0.01 degrms 0.02 degrms 0.02 degrms 0.01 degrms 0.005 degrms 0.005 degrms 0.003 degrms 0.006 degrms Specification Typical (test port input level = maximum power in Specification) Magnitude (Transmission) 9 k to 30 kHz, 1 kHz IFBW 30 k to 10 MHz, 1 kHz IFBW 10 M to 6 GHz, 10 kHz IFBW 6 G to 9 GHz, 10 kHz IFBW (Reflection) 9 k to 30 kHz, 1 kHz IFBW 30 k to 10 MHz, 1 kHz IFBW 10 M to 1.5 GHz, 10 kHz IFBW 1.5 G to 6 GHz, 10 kHz IFBW 6 GHz to 9 GHz, 10 kHz IFBW Phase (Transmission) 9 k to 30 kHz, 1 kHz IFBW 30 k to 100 kHz, 1 kHz IFBW 100 k to 10 MHz, 1 kHz IFBW 10 M to 6 GHz, 10 kHz IFBW 6 GHz to 9 GHz, 10 kHz IFBW (Reflection) 9 k to 30 kHz, 1 kHz IFBW 30 k to 100 kHz, 1 kHz IFBW 100 k to 10 MHz, 1 kHz IFBW 10 M to 1.5 GHz, 10 kHz IFBW 1.5 G to 6 GHz, 10 kHz IFBW 6 GHz to 9 GHz, 10 kHz IFBW Stability Description Magnitude 9 k to 3 GHz 3 G to 6 GHz 6 G to 9 GHz Phase 9 k to 3 GHz 3 G to 6 GHz 6 G to 9 GHz ± 0.005 dB/°C ± 0.01 dB/°C ± 0.04 dB/°C ± 0.1 deg/°C ± 0.2 deg/°C ± 0.8 deg/°C 12 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Dynamic accuracy 1, 2 Description Specification Magnitude 10 dBm 5 dBm 0 dBm —5 dBm —10 dBm (Ref.) —15 dBm —20 dBm —30 dBm —40 dBm —50 dBm —60 dBm —70 dBm —80 dBm —90 dBm —100 dBm ± 0.207 dB ± 0.071 dB ± 0.027 dB ± 0.012 dB ± 0.006 dB ± 0.009 dB ± 0.011 dB ± 0.014 dB ± 0.018 dB ± 0.021 dB ± 0.029 dB ± 0.072 dB ± 0.116 dB ± 0.159 dB ± 0.202 dB Phase 10 dBm 5 dBm 0 dBm —5 dBm —10 dBm (Ref.) —15 dBm —20 dBm —30 dBm —40 dBm —50 dBm —60 dBm —70 dBm —80 dBm —90 dBm —100 dBm ± 5.02 deg ± 0.67 deg ± 0.14 deg ± 0.06 deg ± 0.04 deg ± 0.05 deg ± 0.06 deg ± 0.08 deg ± 0.10 deg ± 0.13 deg ± 0.18 deg ± 0.47 deg ± 0.76 deg ± 1.05 deg ± 1.34 deg Typical 1. Accuracy of the test port input power reading is relative to –10 dBm reference input power level. IFBW is equal to or lower than 10 Hz. 2. Applies to the units with Serial Number Prefix MY552/SG552 and above 13 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Group delay 1 Description Specification Aperture (selectable) (frequency span)/(number of points - 1) Maximum aperture 25% of frequency span Typical Minimum delay Limited to measuring no more than 180° of phase change within the minimum aperture. Accuracy See graph below (typical) 1. Group delay is computed by measuring the phase change within a specified step (determined by the frequency span and the number of points per sweep). The following graph shows group delay accuracy with type-N connectors, full 2-port calibration and a 10 Hz IF bandwidth. –– Calibration kit (85032F). –– Insertion loss is assumed to be < 2 dB. In general, the following formula can be used to determine the accuracy, in seconds, of a specific group delay measurement: ± phase accuracy (degrees)/[360 x aperture (Hz)] 14 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet General Information Description IF band width Range General characteristic 1 Hz to 1.5 MHz Nominal settings are: 1, 2, 3, 4, 5, 7, 10, 15, 20, 30, 40, 50, 70, 100, 150, 200, 300, 400, 500, 700, 1 k, 1.5 k, 2 k, 3 k, 4 k, 5 k, 7 k, 10 k, 15 k, 20 k, 9 k, 40 k, 50 k, 70 k, 100 k, 150 k, 200 k, 300 k, 400 k, 500 k, 700 k, 1M, 1.5 M Front panel Description Typical General characteristic Test Ports Type –N, female, 50 Ω (nominal) Display Type Resolution 12.1 inch TFT color LCD with touch screen WXGA (1280 x 800) 1 Universal serial bus jack, Type A configuration; female; provides connection to mouse, key board, printer, ECal module, USB power sensor, or USB/ GPIB interface USB host port Rear panel Description Typical External trigger input connector Type Input level BNC, female Low threshold voltage: 0.5 V High threshold voltage: 2.1 V Input level range: 0 to + 5 V ≥ 2 μsec Positive or negative Pulse width Polarity External trigger output connector Type Maximum output current Output level BNC, female 50 mA Low level voltage: 0 V High level voltage: 5 V 1 μsec Positive or negative Pulse width Polarity External reference signal input connector Type Input frequency Input level Internal reference signal output connector Type Output frequency Signal Type Output level Output Impedance 1. General characteristic BNC, female 10 MHz ± 10 ppm —3 to +10 dBm BNC, female 10 MHz ± 7 ppm Sinewave 0 dBm ± 3 dB into 50 Ω 50 Ω Valid pixels are 99.99% and more. Below 0.02% of fixed points of black, blue, green or red are not regarded as failure. 15 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Description Typical Internal reference signal oven connector (option 1E5) Type Output frequency Output level 10 MHz ± 0.45 ppm 0 dBm minimum Bias tee input connector Type Damage level Max. current (no degradation in RF specifications) Over current protection General characteristic BNC, female BNC, female ± 35 V, 500 mA DC ± 300 mA at 100 kHz to 9 GHz 500 mA (with Fuse) Video output 15-pin mini D-Sub; female; drives WXGA compatible monitors GPIB 24-pin D-Sub (Type D-24), female; compatible with IEEE-488 USB host port Universal serial bus jack, Type A configuration; female; provides connection to mouse, key board, printer, ECal module, USB power sensor, or USB/ GPIB interface USB (USBTMC 1) interface port Universal serial bus jack, Type B configuration (4 contacts inline); female; provides connection to an external PC; compatible with USBTMCUSB488 and USB 2.0.LA LAN 10/100BaseT Ethernet, 8-pin configuration; auto selects between the two data rates Handler I/O port 36-pin centronics, female; provides connection to handler system Line power 2 Frequency Power consumption 3 47 Hz to 63 Hz 2-port: 135 W 4-port: 165 W 90-264 VAC (Vpeak > 120 V) 300 VA max. Voltage VA max 1. USB Test and Measurement Class (TMC) interface that communicates over USB, complying with the IEEE 488.1 and IEEE 488.2 standards. 2. A third-wire ground is required. 3. At preset. Description AUX input connector Type Input range Accuracy Specification Typical BNC, female x 2 ports ± 1 V or ± 10 V selectable 1 % ± 1 mV for 1 V input range 1 % ± 10 mV for 10 V input range 16 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet EMC, safety, environment and compliance Description General characteristics EMC European Council Directive 2004/108/EC IEC 61326-1:2012 EN 61326-1:2013 CISPR 11:2009 +A1:2010 EN 55011: 2009 +A1:2010 Group 1, Class A IEC 61000-4-2:2008 EN 61000-4-2:2009 4 kV CD / 8 kV AD IEC 61000-4-3:2006 +A1:2007 +A2:2010 EN 61000-4-3:2006 +A1:2008 +A2:2010 3 V/m, 80-1000 MHz, 1.4 - 2.0 GHz /1V/m, 2.0 - 2.7 GHz, 80% AM IEC 61000-4-4:2004 +A1:2010 EN 61000-4-4:2004 +A1:2010 1 kV power lines / 0.5 kV signal lines IEC 61000-4-5:2005 EN 61000-4-5:2006 0.5 kV line-line / 1 kV line-ground IEC 61000-4-6:2008 EN 61000-4-6:2009 3 V, 0.15-80 MHz, 80% AM IEC 61000-4-8:2009 EN 61000-4-8:2010 30A/m, 50/60Hz IEC 61000-4-11:2004 EN 61000-4-11:2004 0.5-300 cycle, 0% / 70% ICES-001:2006 Group 1, Class A AS/NZS CISPR11:2004 Group 1, Class A KN11, KN61000-6-1 and KN61000-6-2 Group 1, Class A Safety European Council Directive 2006/95/EC IEC 61010-1:2001/EN 61010-1:2001 Measurement Category I Pollution Degree 2 Indoor Use CAN/CSA C22.2 No. 61010-1-12 Measurement Category I Pollution Degree 2 Indoor Use Environment This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as a “Monitoring and Control instrumentation” product. Do not dispose in domestic household waste. To return unwanted products, contact your local Keysight office, or see http://www.keysight.com/environment/product/ for more information. Compliance Class C 17 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Analyzer environmental specifications and dimensions Description General characteristic Operating environment Temperature Error-corrected temperature range Humidity Altitude Vibration 0 °C to +40 °C 23 °C (± 3 °C) with < 1 °C deviation from calibration temperature 20% to 80 % at wet bulb temperature < +29 °C (non-condensation) 0 to 2,000 m (0 to 6561 feet) 0.21 G maximum, 5 Hz to 500 Hz Non-operating environment Temperature Humidity Altitude Vibration —10 °C to +60 °C 20 % to 90 % at wet bulb temperature < +40 °C (non-condensation) 0 to 4,572 m (0 to 15,000 feet) 0.5 G maximum, 5 Hz to 500 Hz Weight (net) Option 245/265/295: 20.3 kg Option 445/465/495: 22.7 kg Dimensions Dimensions (front view, E5080A with option 245/265/295, in millimeters) 18 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Dimensions (front view, E5080A with option 445/465/495, in millimeters) Dimensions (rear view with option 1E5, in millimeters) 19 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Dimensions (rear view with option 1E5, in millimeters) Measurement Throughput Summary Measurement throughput data is supplemental performance data. Common condition for the measurement throughput data: –– Analyzer display turned off with: DISPlay:ENABle OFF, DISPlay:VISible OFF –– Number of traces = 1 –– firmware version: A.11.00 Cycle time for measurement completion Sweep type: Auto System error correction: OFF Sweep type: Stepped System error correction: ON Number of Points 51 201 401 1601 51 201 401 1601 Start 800 MHz, stop 1 GHz, 500 kHz IF bandwidth Uncorrected 1.3 1.8 2.5 7.0 1.5 2.8 4.3 13 2-port cal 2.2 3.0 5.2 17 2.6 5.1 8.2 24 4-port cal 4.0 6.2 12 31 4.7 11 18 51 Start 800 MHz, stop 1 GHz, 1 kHz IF bandwidth Uncorrected 51 196 389 1546 51 196 389 1546 2-port cal 101 391 777 3092 101 391 777 3092 4-port cal 201 781 1554 6187 201 781 1554 6187 Start 100 kHz, stop 4.5 GHz, 500 kHz IF bandwidth Uncorrected 3.1 5.4 7.7 12 3.1 5.4 7.8 20 2-port cal 5.7 11 15 24 5.8 11 15 39 4-port cal 11 21 31 50 11 21 31 81 Unit: ms 20 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Start 100 kHz, stop 4.5 GHz, 1 kHz IF bandwidth Uncorrected 53 199 393 1554 53 199 393 1554 2-port cal 104 396 784 3107 104 396 784 3107 4-port cal 207 792 1569 6217 207 792 1569 6217 Start 100 kHz, stop 9 GHz, 500 kHz IF bandwidth Uncorrected 3.8 6.1 8.4 18 3.8 6.1 8.4 20 2-port cal 7.0 12 17 35 7.0 12 17 40 4-port cal 14 23 33 73 14 23 34 83 Start 100 kHz, stop 9 GHz, 1 kHz IF bandwidth Uncorrected 53 199 393 1554 53 199 393 1554 2-port cal 105 397 785 3108 105 397 785 3108 4-port cal 210 794 1571 6219 210 794 1571 6219 Unit: ms Cycle time vs. number of points Condition: Start = 800 MHz, Stop = 1 GHz, 500 kHz IF bandwidth Number of points Sweep type: Auto System error correction: OFF Sweep type: Stepped System error correction: ON 3 1.1 1.0 11 1.1 1.1 51 1.3 1.5 101 1.4 2.0 201 1.8 2.8 401 2.5 4.3 801 3.9 7.0 1601 7.0 13 Unit: ms Cycle time vs. IF bandwidth Condition: Frequency = 4 GHz, NOP = 201, system error correction: OFF IF BW (Hz) Cycle time (ms) IF BW (Hz) Cycle time (ms) IF BW (Hz) Cycle time (ms) IF BW (Hz) Cycle time (ms) IF BW (Hz) Cycle time (ms) IF BW (Hz) Cycle time (ms) 10 19299 100 1932 1000 195 10000 21 100000 3.1 1000000 1.8 1500000 1.8 15 12867 150 1288 1500 131 15000 14 150000 2.4 20 9651 200 967 2000 98 20000 11 200000 2.1 30 6434 300 645 3000 66 30000 7.6 300000 1.9 40 4826 400 484 4000 50 40000 6.0 400000 1.8 50 3861 500 388 5000 40 50000 5.0 500000 1.8 70 2736 700 275 7000 29 70000 3.9 700000 1.8 21 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Data transfer time (ms) 1 Number of Points 51 201 401 1601 64-bit floating point 2.7 6.8 13 45 32-bit floating point 1.9 4.0 6.8 23 ASCII 6.1 21 37 143 1.4 1.4 2.0 SCPI over GPIB 2 SCPI over 1 Gbps LAN (Socket) 2 REAL 64 1.4 REAL 32 1.4 1.4 1.4 1.6 ASCII 4.3 13 23 86 SCPI over 1 Gbps LAN (SICL-LAN) 2 REAL 64 1.9 1.8 1.8 2.6 REAL 32 2.0 1.9 1.9 2.1 ASCII 2.8 4.3 6.4 20 2.3 2.5 2.5 3.0 SCPI over USB (SICL-USB) 2 REAL 64 REAL 32 2.3 2.3 2.5 2.7 ASCII 2.3 5.2 8.2 28 SCPI over GPIB/USB (82357B) REAL 64 5.9 9.5 15 44 REAL 32 5.3 7.1 9.6 25 ASCII 36 133 265 1061 1. Supplemental performance data. Data transfer time varies depending on the type of PC and control software. 2. Transferred LogMag S11 data, using :CALC{ch}:MEAS{tr}:DATA:FDAT?. 22 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet E5092A Configurable multiport test set The section provides test input/output performance without calibration by the E5080A. Table 46. Test set input/output performance Description Specification Frequency range 50 MHz to 20 GHz Damage level Typical 20 dBm, ± 35 VDC Table 47. Option E5092A-020 port performance Description Specification Typical Load match (selected port) SPDT switch 1 50 MHz to 2 GHz 2 GHz to 4 GHz 4 GHz to 8 GHz 8 GHz to 10 GHz 10 GHz to 18 GHz 18 GHz to 20 GHz 17 dB 11 dB 8 dB 7 dB 4 dB 4 dB SP4T switch 2 50 MHz to 2 GHz 2 GHz to 3 GHz 3 GHz to 8 GHz 8 GHz to 10 GHz 10 GHz to 18 GHz 18 GHz to 20 GHz 17 dB 11 dB 8 dB 7 dB 4 dB 4 dB Load match (unselected port) SPDT switch 1 50 MHz to 3 GHz 3 GHz to 10 GHz 10 GHz to 16 GHz 16 GHz to 18 GHz 18 GHz to 20 GHz 17 dB 11 dB 8 dB 6 dB 4 dB SP4T switch 2 50 MHz to 3 GHz 3 GHz to 10 GHz 10 GHz to 16 GHz 16 GHz to 18 GHz 18 GHz to 20 GHz 17 dB 11 dB 8 dB 6 dB 4 dB Load match (common port) SPDT switch 1 50 MHz to 2 GHz 2 GHz to 4 GHz 4 GHz to 8 GHz 8 GHz to 10 GHz 10 GHz to 20 GHz 16 dB 11 dB 8 dB 7 dB 4 dB SP4T switch 2 50 MHz to 1.3 GHz 1.3 GHz to 4 GHz 4 GHz to 8 GHz 8 GHz to 10 GHz 10 GHz to 20 GHz 16 dB 11 dB 8 dB 7 dB 4 dB 1. SPDT: Single-pole-double-throw switches. Applies to SW5, SW6, SW7, SW8, SW9 and SW10 in the E5092A. (See Figure 20.) 2. SP4T: Single-pole-four-throw switches. Applies to SW1, SW2, SW3 and SW4 in the E5092A. (See Figure 20.) 23 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Table 48. Option E5092A-020 port performance (continued) Description Specification Typical Insertion loss SPDT switch 1 50 MHz to 100 MHz 100 MHz to 2 GHz 2 GHz to 3 GHz 3 GHz to 4 GHz 4 GHz to 6 GHz 6 GHz to 8 GHz 8 GHz to 10 GHz 10 GHz to 14 GHz 14 GHz to 18 GHz 18 GHz to 20 GHz 4 dB 3.5 dB 4.5 dB 5 dB 5.5 dB 7 dB 8 dB 8.5 dB 10 dB 11.5 dB SP4T switch 2 50 to 100 MHz 100 MHz to 2 GHz 2 GHz to 3 GHz 3 GHz to 4 GHz 4 GHz to 6 GHz 6 GHz to 8 GHz 8 GHz to 10 GHz 10 GHz to 14 GHz 14 GHz to 18 GHz 18 GHz to 20 GHz 4 dB 3.5 dB 4.5 dB 5.5 dB 6 dB 7.5 dB 8.5 dB 9.5 dB 10.5 dB 12 dB Stability per switch Condition: Enviroment Temperature +23 °C ± 3 °C and Internal DC source: ≤ 100 mA (Sum of 4 channels), no heat source and no wall close to the unit. 0.003 dB/°C (SPD) 0.005 dB/°C (SPD) 0.008 dB/°C (SPD) 50 M to 4 GHz 4 G to 12 GHz 12 G to 20 GHz Condition: besides the above 50 M to 4 GHz 4 G to 12 GHz 12 G to 20 GHz Isolation 3 50 MHz to 500 MHz 500 MHz to 1 GHz 1 GHz to 2 GHz 2 GHz to 6 GHz 6 GHz to 10 GHz 10 GHz to 18 GHz 18 GHz to 20 GHz 0.007 dB/°C (SPD) 0.012 dB/°C (SPD) 0.017 dB/°C (SPD) 65 dB 80 dB 85 dB 90 dB 85 dB 75 dB 65 dB (Over arbitrarily test ports) 1. SPDT: Single-pole-double-throw switches. Applies to SW5, SW6, SW7, SW8, SW9 and SW10 in the E5092A. (See Figure 20.) 2. SP4T: Single-pole-four-throw switches. Applies to SW1, SW2, SW3 and SW4 in the E5092A. (See Figure 20.) 3. This specification is defined when all ports are terminated with a 50 ohm load. 24 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Table 49. Control line Description Specification Number of groups 4 Group A: 8 bits Group B,C,D: 4 bits Input voltage range1 0 V to +5 V (positive input) —5 V to 0 V (negative input) Maximum current Group A, B: 50 mA in total of each group Group C, D: 500 uA in total of each group Impedance Typical Group A, B: < 10 ohm Group C, D: < 200 ohm Table 50. DC source Description Specification Number of sources 4 Output voltage range Output voltage accuracy 0 V to +5.2 V (nominal) 2 ± 3 % of setting (+1 V to +5 V) at 1 M ohm load impedance Voltage resolution Maximum current Typical 10 mV (nominal) 3 150 mA for each source Output impedance < 5 ohm Table 51. Operating storage environment Description General characteristics Temperature +5 °C to +40 °C Humidity 20 to 80 % at wet bulb temperature < +29 °C (non-condensing) Altitude 0 to 2,000m (0 to 6,561 feet) Vibration 0.21 G max., 5 to 500 Hz Table 52. Non-operating storage environment Description General characteristics Temperature —10 °C to +60 °C Humidity 20 to 90 % at wet bulb temperature < +40 °C (non-condensing) Altitude 0 to 4,572 m (0 to 15,000 feet) Vibration 0.5 G max., 5 Hz to 500 Hz Table 53. Front panel information Description General characteristics RF connectors SMA (female) Test ports 38 ports Control line 15-pin D-sub, female 25-pin D-sub, female 1. Input voltage will be clipped at about ± 5.2 V when over this range. 2. The output voltage can be set in this range. 3. The output voltage resolution becomes effective between 0 V to 5.2 V. 25 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Table 54. Rear panel information Description General characteristics USB port Type B-receptacle, provide connection to the E5080A Line power Frequency Voltage 1 47 to 63 Hz 90 to 132 VAC, or 198 to 264 VAC (automatically switched) 300 VA max. VA max 1. 1A third-wire ground is required. Table 55. Test set dimensions and block diagram Description General characteristics Weight E5092A Option 020 9 kg Dimensions Figure 10. Dimensions (front view, with Option E5092A-020, in millimeters, nominal) Figure 11. Dimensions (pitch between switches, with Option E5092A-020, in millimeters, nominal) 26 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet 37 51 83 133 129 Figure 11. Dimensions (pitch between switches, with Option E5092A-020, in millimeters, nominal) 22 13 18 32 133 146 472 417 144 126 23 Figure 13. Dimensions (side view, with Option E5092A-020, in millimeters, nominal) Figure 14. Switch configuration (E5092A-020) 27 | Keysight | E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet Control Line 1 (Group A) DC Source (Group A) Max Current Output Voltage DC Source Output Control Line 1 (Group A) Control Line 2 (Group A) Positive Input (High) Control Line 3 (Group A) Output Impedance : Negative Input (Low) DC Source (Group B) DC Source Output Impedance Control Line 2 (Group B) Positive Input (High) Negative Input (Low) DC Source (Group C) DC Source Output Control Line 2 (Group C) Positive Input (High) Negative Input (Low) DC Source (Group D) DC Source Output Control Line 2 (Group D) Positive Input (High) Negative Input (Low) Figure 15. DC control line (E5092A-020) Figure 16. Control line pin assignment (E5092A-020) : Control Line 4 (Group A) : Control Line 8 (Group A) Control Line 1 (Group B) Control Line 2 (Group B) Control Line 3 (Group B) Control Line 4 (Group B) Control Line 1 (Group C) Control Line 2 (Group C) Control Line 3 (Group C) Control Line 4 (Group C) Control Line 1 (Group D) Control Line 2 (Group D) Control Line 3 (Group D) Control Line 4 (Group D) 28 | Keysight |E5080A ENA Series Network Analyzer, E5092A Configurable Multiport Test Set - Data Sheet From Hewlett-Packard through Agilent to Keysight For more than 75 years, we‘ve been helping you unlock measurement insights. Our unique combination of hardware, software and people can help you reach your next breakthrough. Unlocking measurement insights since 1939. 1939 THE FUTURE myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s committed to superior product quality and lower total cost of ownership. Keysight is the only test and measurement company with a three-year warranty standard on all instruments, worldwide. And, we provide a one-year warranty on many accessories, calibration devices, systems and custom products. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to ten years of protection and no budgetary surprises to ensure your instruments are operating to specification, so you can rely on accurate measurements. Keysight Infoline www.keysight.com/find/service Keysight’s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 11 2626 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-01-01-16) www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System This information is subject to change without notice. © Keysight Technologies, 2015, 2016 Published in USA, January 19, 2016 5992-0291EN www.keysight.com