UTC IMX2L-AG6-R General purpose dual transistor Datasheet

UNISONIC TECHNOLOGIES CO., LTD
IMX2
DUAL TRANSISTOR
GENERAL PURPOSE DUAL
TRANSISTOR
„
FEATURES
* Two 2SC2412 chips in a SMT package
EQUIVALENT CIRCUITS
„
(6)
(5)
(4)
TR2
(1)
„
TR1
(2)
(3)
ORDERING INFORMATION
Ordering Number
Package
Lead Free
Halogen Free
IMX2L-AG6 -R
IMX2G-AG6-R
SOT-26
Note: Pin Assignment: B: Base C: Collector E: Emitter
Pin Assignment
Packing
1
2
3
4
5
6
C2 B1 C1 E1 E2 B2 Tape Reel
IMX2L-AG6-R
„
(1)Packing Type
(1) R: Tape Reel
(2)Package Type
(2) AG6: SOT-26
(3)Lead Free
(3) G: Halogen Free, L: Lead Free
MARKING
www.unisonic.com.tw
Copyright © 2011 Unisonic Technologies Co., Ltd
1 of 2
QW-R215-004.Ba
IMX2
„
DUAL TRANSISTOR
ABSOLUTE MAXIMUM RATINGS (TA=25°C)
PARAMETER
SYMBOL
RATING
UNIT
Collector-Base Voltage
VCBO
60
V
Collector-Emitter Voltage
VCEO
50
V
Emitter-Base Voltage
VEBO
7
V
Collector Current
IC
150
mA
Collector Power Dissipation
PC
300 (Note 1)
mW
Junction Temperature
TJ
150
°C
Storage Temperature
TSTG
-55~+150
°C
Note: 1. 200mW per element must not be exceeded.
2. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
„
ELECTRICAL CHARACTERISTICS (TA=25°C)
PARAMETER
SYMBOL
Collector-Base Breakdown Voltage
BVCBO
Collector-Emitter Breakdown Voltage
BVCEO
Emitter-Base Breakdown Voltage
BVEBO
Collector Cut-Off Current
ICBO
Emitter Cut-Off Current
IEBO
Collector-Emitter Saturation Voltage
VCE(SAT)
DC Current Transfer Ratio
hFE
Transition Frequency (Note)
fT
Output Capacitance
COB
Note: Transition frequency of the device.
„
TEST CONDITIONS
IC= 50µA
IC= 1mA
IE= 50µA
VCB= 60V
VEB= 7V
IC / IB = 50mA/5mA
VCE= 6V, IC= 1mA
VCE=12V, IE=-2mA, f=100MHz
VCB= 12V, IE=0A, f=1KHz
MIN
60
50
7
TYP
MAX
0.1
0.1
0.4
560
120
180
2
3.5
UNIT
V
V
V
µA
µA
V
MHz
pF
CLASSIFICATION OF hFE
RANK
RANGE
Q
120-270
R
180-390
S
270-560
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 2
QW-R215-004.Ba