EPCOS B32538B5684 Metallized polyester film capacitors (mkt-s) Datasheet

Metallized Polyester Film Capacitors (MKT-S)
Series/Type:
B32538
The following products presented in this data sheet are being withdrawn.
Ordering Code
Substitute Product
B32538*
B32537
Date of
Withdrawal
2007-02-09
Deadline Last
Orders
2007-03-31
Last Shipments
2007-09-30
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
Metallized polyester film capacitors (MKT-S)
B32538
High reliability (wound)
Typical applications
Test and measurement equipment
Rough environments
Dimensional drawing
Climatic
Max. operating temperature: 125 °C
Climatic category (IEC 60068-1): 55/100/56
Features
Optimum self-healing capability
Excellent short circuit protection
Very high reliability
Dimensions in mm
Diameter d
Lead diameter d1
Construction
Dielectric: polyethylene terephthalate
(polyester, PET)
Construction with structured metallization
Tubular winding
Insulating sleeve
Face ends sealed with epoxy resin
<7.8
0.6
7.8 ... 16
0.8
>16
1.0
When bending leads take care to leave a
clearance of 1 mm to the capacitor body.
Terminals
Central axial leads, lead-free tinned
Marking
Manufacturer's logo,
style(MKT-S), rated capacitance (coded),
capacitance tolerance (code letter),
rated voltage, date of manufacture (coded)
Delivery mode
Bulk (untaped)
Taped (Ammo pack)
For notes on taping, refer to chapter "Taping and packing“.
2
B32538
High reliability (wound)
Overview of types
Type
B32538
VR (VDC)
50
100
160
250
630
Vrms (VAC)
20
35
60
90
200
CR (µF)
0.033
0.047
0.068
0.10
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
22
47
100
3
B32538
High Reliability (Wound)
Ordering codes and packing units
VR
Vrms
CR
f ≤60 Hz
VDC VAC
µF
0.47
50
20
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
0.10
100
35
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
22
47
100
Max. dimensions
d×l
mm
6.1 × 16.0
6.3 × 16.0
6.9 × 16.0
7.6 × 16.0
7.4 × 20.0
8.2 × 20.0
9.3 × 20.0
10.8 × 20.0
12.6 × 20.0
6.2 × 16.0
6.4 × 16.0
6.9 × 16.0
7.0 × 16.0
6.7 × 16.0
6.7 × 16.0
6.7 × 20.0
7.4 × 20.0
8.0 × 20.0
9.2 × 20.0
10.4 × 20.0
9.0 × 32.5
10.7 × 32.5
14.6 × 32.5
20.2 × 32.5
28.2 × 32.5
Ordering code
(composition see
below)
B32538B5474+***
B32538B5684+***
B32538B5105+***
B32538B5155+***
B32538B5225+***
B32538B5335+***
B32538B5475+***
B32538B5685+***
B32538B5106+***
B32538B1104+***
B32538B1154+***
B32538B1224+***
B32538B1334+***
B32538B1474+***
B32538B1684+***
B32538B1105+***
B32538B1155+***
B32538B1225+***
B32538B1335+***
B32538B1475+***
B32538B1685+***
B32538B1106+***
B32538B1226+***
B32538B1476+***
B32538B1107+***
Ammo pack
Untaped
pcs./unit
pcs./unit
1100
1000
950
870
900
800
700
400
350
1000
1000
950
950
950
950
950
900
800
700
400
700
400
PU on request
PU on request
PU on request
50
50
50
50
50
50
20
20
20
50
50
50
50
50
50
50
50
50
20
20
20
20
20
20
20
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
M = ±20%
K = ±10%
*** = Packaging code:
007 = Ammo pack
000 = Untaped
4
B32538
High Reliability (Wound)
Ordering codes and packing units
VR
Vrms
CR
f ≤60 Hz
VDC VAC
µF
0.10
160
60
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
0.10
250
90
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
Max. dimensions
d×l
mm
6.1 × 16.0
6.2 × 16.0
6.4 × 16.0
7.0 × 16.0
6.9 × 20.0
7.5 × 20.0
8.3 × 20.0
10.5 × 20.0
11.0 × 20.0
10.0 × 32.5
11.3 × 32.5
13.1 × 32.5
15.3 × 32.5
6.7 × 16.0
7.2 × 16.0
7.3 × 16.0
7.3 × 20.0
8.0 × 20.0
9.0 × 20.0
10.3 × 20.0
12.0 × 20.0
14.0 × 20.0
12.6 × 32.5
14.5 × 32.5
17.0 × 32.5
20.1 × 32.5
Ordering code
(composition see
below)
B32538B2104+***
B32538B2154+***
B32538B2224+***
B32538B2334+***
B32538B2474+***
B32538B2684+***
B32538B2105+***
B32538B2155+***
B32538B2225+***
B32538B2335+***
B32538B2475+***
B32538B2685+***
B32538B2106+***
B32538B3104+***
B32538B3154+***
B32538B3224+***
B32538B3334+***
B32538B3474+***
B32538B3684+***
B32538B3105+***
B32538B3155+***
B32538B3225+***
B32538B3335+***
B32538B3475+***
B32538B3685+***
B32538B3106+000
Ammo pack
Untaped
pcs./unit
1100
1000
1000
950
950
870
800
400
400
450
380
PU on request
PU on request
950
900
900
900
800
700
400
380
300
350
PU on request
PU on request
pcs./unit
50
50
50
50
50
50
50
20
20
20
20
20
20
50
50
50
50
50
20
20
20
20
20
20
20
20
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
M = ±20%
K = ±10%
*** = Packaging code:
007 = Ammo pack
000 = Untaped
5
B32538
High Reliability (Wound)
Ordering codes and packing units
VR
Vrms
CR
f ≤60 Hz
VDC VAC
µF
0.033
630 200
0.047
0.068
0.10
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
Max. dimensions
d×l
mm
6.7 × 16.0
7.3 × 16.0
7.2 × 20.0
7.9 × 20.0
9.0 × 20.0
10.5 × 20.0
12.0 × 20.0
13.9 × 20.0
12.3 × 32.5
14.3 × 32.5
17.0 × 32.5
20.0 × 32.5
23.9 × 32.5
28.1 × 32.5
Ordering code
(composition see
below)
B32538B8333+***
B32538B8473+***
B32538B8683+***
B32538B8104+***
B32538B8154+***
B32538B8224+***
B32538B8334+***
B32538B8474+***
B32538B8684+***
B32538B8105+***
B32538B8155+***
B32538B8225+000
B32538B8335+000
B32538B8475+000
Ammo pack
Untaped
pcs./unit
950
900
900
800
700
400
380
300
350
PU on request
PU on request
pcs./unit
50
50
50
50
20
20
20
20
20
20
20
20
20
20
Further E series and intermediate capacitance values on request.
Composition of ordering code
+ = Capacitance tolerance code:
M = ±20%
K = ±10%
*** = Packaging code:
007 = Ammo pack
000 = Untaped
6
B32538
High reliability (wound)
Technical data
Operating temperature range
Max. operating temperature Top,max
Upper category temperature Tmax
Lower category temperature Tmin
Rated temperature TR
Dissipation factor tan δ (in 10-3) CR (µF)
at 20 °C
at
1 kHz
(upper limit values)
at 10 kHz
Insulation resistance Rins
or time constant τ = CR Rins
at 20 °C, rel. humidity ≤ 65%
(minimum as-delivered values)
DC test voltage
Category voltage VC
(continuous operation with VDC
or VAC at f ≤ 60 Hz)
Operating voltage V op for
short operating periods
(VDC or VAC at f ≤ 60 Hz)
Damp heat test
Limit values after damp
heat test
Reliability:
Failure rate λ
Service life tSL
Failure criteria:
Total failure
Failure due to variation
of parameters
CR
≤ 0.33 µF
> 0.33 µF
+125 °C
+100 °C
55 °C
+85 °C
≤ 0.47
0.47 < CR ≤4.7 4.7 < CR ≤10.0 > 10.0
7
15
8
22
8
25
10
> 15000 MΩ
> 5000 s
1.4 VR, 2 s
TA (°C)
DC voltage derating
TA ≤ 85
VC = VR
85<TA≤100 VC = VR (165TA)/80
TA (°C)
DC voltage (max. hours)
TA ≤ 100
Vop = 1.25 VC (2000 h)
100<TA≤125 Vop = 0.5 VR (1000 h)
56 days/40 °C/93% relative humidity
Capacitance change ∆C/C
Dissipation factor change ∆ tan δ
Insulation resistance Rins
AC voltage derating
VC,rms = Vrms
VC,rms=Vrms (165TA)/80
AC voltage (max. hours)
Vop = 1.0 VC,rms (2000 h)
Vop = 0.5 Vrms (1000 h)
≤ 5%
≤ 5 10-3 (at 1 kHz)
≥ 50% of minimum
as-delivered values
1 fit (≤ 1 10-9/h) at 0.5 VR, 40 °C
200 000 h at 1.0 VR, 40 °C
For conversion to other operating conditions and temperatures,
refer to chapter "Quality assurance", page .
Short circuit or open circuit
Capacitance change ∆C/C
Dissipation factor tan δ
Insulation resistance Rins
or time constant τ = CR Rins
7
> 10%
> 1.5 upper limit value
< 150 MΩ (CR ≤ 0.33 µF)
< 50 s
(CR > 0.33 µF)
B32538
High reliability (wound)
Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k0" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V 2/µs.
Note:
The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lenght of capacitor
VR
Vrms
VDC
VAC
50
100
160
250
630
20
35
60
90
200
16 mm
20 mm
dV/dt in V/µs
2.5
32.5 mm
13
20
23
40
9
12
16
26
6
8
10
18
16 mm
20 mm
32.5 mm
k0 in V2/µs
250
2 600
6 400
11 500
50 400
150
1 800
3 840
8 000
32 800
1 200
2 560
5 000
22 700
1.5
k0 values
Lenght of capacitor
VR
Vrms
VDC
VAC
50
100
160
250
630
20
35
60
90
200
8
B32538
High reliability (wound)
Impedance Z versus frequency f
(typical values)
Permissible AC voltage Vrms versus frequency f
Values can be obtained on request. In specific cases please provide a scaled voltage/ time graph
and state operating conditions.
9
Similar pages