TI CDCEL937 Programmable 1-pll vcxo clock synthesizer with 1.8-v, 2.5-v, and 3.3-v output Datasheet

CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
Programmable 1-PLL VCXO Clock Synthesizer With 1.8-V, 2.5-V, and 3.3-V Outputs
•
FEATURES
1
• Member of Programmable Clock Generator
Family
– CDCE913/CDCEL913: 1-PLL, 3 Outputs
– CDCE925/CDCEL925: 2-PLL, 5 Outputs
– CDCE937/CDCEL937: 3-PLL, 7 Outputs
– CDCE949/CDCEL949: 4-PLL, 9 Outputs
• In-System Programmability and EEPROM
– Serial Programmable Volatile Register
– Nonvolatile EEPROM to Store Customer
Setting
• Flexible Input Clocking Concept
– External Crystal: 8 MHz to 32 MHz
– On-Chip VCXO: Pull Range ±150 ppm
– Single-Ended LVCMOS up to 160 MHz
• Free Selectable Output Frequency up to
230 MHz
• Low-Noise PLL Core
– PLL Loop Filter Components Integrated
– Low Period Jitter (Typical 50 ps)
2345
•
•
•
•
•
Flexible Clock Driver
– Three User-Definable Control Inputs
[S0/S1/S2] e.g., SSC Selection,
Frequency Switching, Output Enable or
Power Down
– Programmable SSC Modulation
– Enables 0-PPM Clock Generation
– Generates Common Clock Frequencies
Used With TI-DaVinci™, OMAP™, DSPs
– Generates Highly Accurate Clocks for
Video, Audio, USB, IEEE1394, RFID,
Bluetooth™, WLAN, Ethernet™, and
GPS
1.8-V Device Power Supply
Separate Output Supply Pins
– CDCE913: 3.3 V and 2.5 V
– CDCEL913: 1.8 V
Wide Temperature Range –40°C to 85°C
Packaged in TSSOP
Development and Programming Kit for Easy
PLL Design and Programming (TI Pro-Clock™)
APPLICATIONS
•
VDD
D-TV, STB, IP-STB, DVD-Player, DVD-Recorder,
Printer
VDDOUT
GND
Crystal or
Clock Input
Vctr
S2/S1/S0 or
SDA/SCL
VCXO
XO
LVCMOS
EEPROM
3 Programming
and
Control Register
PLL
with SSC
Divider
and
Output
Control
LV
CMOS
Y1
LV
CMOS
Y2
LV
CMOS
Y3
Xin/CLK
S0
VDD
Vctr
GND
VDDOUT
VDDOUT
1
2
3
4
5
6
7
14
13
12
11
10
9
8
Xout
S1/SDA
S2/SCL
Y1
GND
Y2
Y3
1
2
3
4
5
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
DaVinci, OMAP, Pro-Clock are trademarks of Texas Instruments.
Bluetooth is a trademark of Bluetooth SIG.
I2C is a trademark of Philips Electronics.
Ethernet is a trademark of Xerox Corporattion.
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of the Texas
Instruments standard warranty. Production processing does not
necessarily include testing of all parameters.
Copyright © 2007, Texas Instruments Incorporated
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
DESCRIPTION
The CDCE913 and CDCEL913 are modular PLL-based low-cost, high-performance, programmable clock
synthesizers, multipliers, and dividers. They generate up to 3 output clocks from a single input frequency. Each
output can be programmed in-system for any clock frequency up to 230 MHz, using the integrated configurable
PLL.
The CDCx913 has separate output supply pins, VDDOUT, which is 1.8 V for CDCEL913 and 2.5 V to 3.3 V for
CDCE913.
The input accepts an external crystal or LVCMOS clock signal. If an external crystal is used, an on-chip load
capacitor is adequate for most applications. The value of the load capacitor is programmable from 0 to 20 pF.
Additionally, an on-chip VCXO is selectable which allows synchronization of the output frequency to an external
control signal, i.e. PWM signal.
The deep M/N divider ratio allows the generation of zero-ppm audio/video, networking (WLAN, BlueTooth,
Ethernet, GPS) or interface (USB, IEEE1394, Memory Stick) clocks from e.g., a 27-MHz reference input
frequency.
The PLL supports SSC (spread-spectrum clocking). SSC can be center-spread or down-spread clocking which is
a common technique to reduce electro-magnetic interference (EMI).
Based on the PLL frequency and the divider settings, the internal loop filter components are automatically
adjusted to achieve high stability and optimized jitter transfer characteristic.
The device supports non-volatile EEPROM programming for ease customization of the device to the application.
It is preset to a factory default configuration (see the DEFAULT DEVICE CONFIGURATION section). It can be
re-programmed to a different application configuration before PCB assembly, or re-programmed by in-system
programming. All device settings are programmable through SDA/SCL bus, a 2-wire serial interface.
Three programmable control inputs, S0, S1 and S2, can be used to select different frequencies, or change SSC
setting for lowering EMI, or other control features like, outputs disable to low, outputs 3-state, power down, PLL
bypass etc).
The CDCx913 operates in a 1.8-V environment. It is characterized for operation from –40°C to 85°C
Terminal Functions for CDCE913, CDCEL913
TERMINAL
NAME
Y1–Y3
PIN TSSOP14
11, 9, 8
I/O
DESCRIPTION
O
LVCMOS outputs
Xin/CLK
1
I
Crystal oscillator input or LVCMOS clock Input (selectable via SDA/SCL bus)
Xout
14
O
Crystal oscillator output (leave open or pullup when not used)
VCtrl
4
I
VCXO control voltage (leave open or pullup when not used)
VDD
3
Power
VDDOUT
6, 7
Power
GND
5, 10
Ground
S0
2
I
SDA/S1
13
I/O or I
SCL/S2
12
I
2
1.8-V power supply for the device
CDCEL913: 1.8-V supply for all outputs
CDCE913: 3.3-V or 2.5-V supply for all outputs
Ground
User-programmable control input S0; LVCMOS inputs; internal pullup 500k
SDA: bidirectional serial data input/output (default configuration), LVCMOS internal
pullup; or
S1: user-programmable control input; LVCMOS inputs; internal pullup 500k
SCL: serial clock input LVCMOS (default configuration), internal pullup 500k or
S2: user-programmable control input; LVCMOS inputs; internal pullup 500k
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
VDD
VDDOUT
GND
LV
CMOS
Y1
M2
M1
Xin/CLK
LV
CMOS
Y2
M3
Input Clock
Vctr
LV
CMOS
Y3
Pdiv1
10-Bit
VCXO
XO
with SSC
Xout
MUX1
PLL 1
LVCMOS
PLL Bypass
EEPROM
Pdiv2
7-Bit
Pdiv3
7-Bit
Programming
and
SDA/SCL
Register
S0
S1/SDA
S2/SCL
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted) (1)
VDD
Supply voltage range
(2)
VI
Input voltage range
VO
Output voltage range (2)
II
Input current (VI < 0, VI > VDD)
IO
Tstg
TJ
Maximum junction temperature
(1)
(2)
VALUE
UNIT
–0.5 to 2.5
V
–0.5 to VDD + 0.5
V
–0.5 to VDD + 0.5
V
20
mA
Continuous output current
50
mA
Storage temperature range
–65 to 150
°C
125
°C
Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
The input and output negative voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
PACKAGE THERMAL RESISTANCE for TSSOP (PW) PACKAGE (1) (2)
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TJA
Thermal resistance junction-to-ambient
TJC
Thermal resistance junction-to-case
(1)
(2)
AIRFLOW
(lfm)
TSSOP14
°C/W
0
112
150
105
250
102
500
97
–
46
The package thermal impedance is calculated in accordance with JESD 51 and JEDEC2S2P (high-k board).
For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
3
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
RECOMMENDED OPERATING CONDITIONS
VDD
VO
MIN
NOM
MAX
Device supply voltage
1.7
1.8
1.9
Output Yx supply voltage for CDCE913, VDDOUT
2.3
3.6
Output Yx supply voltage for CDCEL913, VDDOUT
1.7
1.9
VIL
Low-level input voltage LVCMOS
VIH
High-level input voltage LVCMOS
VI
Input voltage threshold LVCMOS
(thresh)
VI(S)
VI(CLK)
0.3 VDD
0.7 VDD
UNIT
V
V
V
V
0.5 VDD
V
Input voltage range S0
0
1.9
Input voltage range S1, S2, SDA, SCL; VI(thresh) = 0.5 VDD
0
3.6
Input voltage range CLK
0
1.9
V
V
Output current (VDDOUT = 3.3 V)
±12
Output current (VDDOUT = 2.5 V)
±10
Output current (VDDOUT = 1.8 V)
±8
CL
Output load LVCMOS
15
pF
TA
Operating free-air temperature
85
°C
IOH /IOL
–40
mA
RECOMMENDED CRYSTAL/VCXO SPECIFICATIONS (1)
fXtal
Crystal input frequency range (fundamental mode)
ESR
Effective series resistance
fPR
Pulling range (0 V ≤ VCtrl ≤ 1.8 V) (2)
NOM
8
27
MAX
UNIT
32
MHz
100
±120
Frequency control voltage, VCtrl
±150
0
C0/C1
Pullability ratio
CL
On-chip load capacitance at Xin and Xout
(1)
(2)
MIN
Ω
ppm
VDD
V
220
0
20
pF
For more information about VCXO configuration, and crystal recommendation, see application report (SCAA085).
Pulling range depends on crystal-type, on-chip crystal load capacitance and PCB stray capacitance; pulling range of min ±120 ppm
applies for crystal listed in the application report (SCAA085).
EEPROM SPECIFICATION
EEcyc
Programming cycles of EEPROM
EEret
Data retention
4
MIN
TYP
100
1000
10
Submit Documentation Feedback
MAX
UNIT
cycles
years
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
TIMING REQUIREMENTS
over recommended ranges of supply voltage, load, and operating free-air temperature
MIN
NOM
MAX
UNIT
CLK_IN REQUIREMENTS
PLL bypass mode
0
160
PLL mode
8
160
40%
60%
fCLK
LVCMOS clock input frequency
tr / tf
Rise and fall time CLK signal (20% to 80%)
3
Duty cycle CLK at VDD/2
STANDARD
MODE
FAST
MODE
MHz
ns
UNIT
MIN
MAX
MIN
MAX
0
100
0
400
SDA/SCL TIMING REQUIREMENTS (see Figure 12)
fSCL
SCL clock frequency
tsu(START)
START setup time (SCL high before SDA low)
th(START)
START hold time (SCL low after SDA low)
tw(SCLL)
SCL low-pulse duration
tw(SCLH)
SCL high-pulse duration
th(SDA)
SDA hold time (SDA valid after SCL low)
tsu(SDA)
SDA setup time
tr
SCL/SDA input rise time
tf
SCL/SDA input fall time
tsu(STOP)
STOP setup time
tBUS
Bus free time between a STOP and START condition
kHz
4.7
0.6
μs
4
0.6
μs
4.7
1.3
μs
4
0.6
μs
0
3.45
250
0
0.9
100
1000
ns
300
300
μs
300
ns
ns
4
0.6
μs
4.7
1.3
μs
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
5
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
DEVICE CHARACTERISTICS
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP (1)
MAX
UNIT
OVERALL PARAMETER
Supply current (see Figure 3)
All outputs off, fCLK = 27 MHz,
fVCO = 135 MHz;
fOUT = 27 MHz
All PLLS on
IDD
IDD(OUT)
Supply current (see Figure 4 and Figure 5)
No load, all outputs on,
fOUT = 27 MHz
VDDOUT = 3.3 V
1.3
VDDOUT = 1.8 V
0.7
IDD(PD)
Power-down current. Every circuit powered
down except SDA/SCL
fIN = 0 MHz,
VDD = 1.9 V
30
V(PUC)
Supply voltage Vdd threshold for power-up
control circuit
fVCO
VCO frequency range of PLL
fOUT
LVCMOS output frequency
11
mA
9
Per PLL
mA
μA
0.85
1.45
V
80
230
MHz
VDDOUT = 3.3 V
230
VDDOUT = 1.8 V
230
MHz
LVCMOS PARAMETER
VIK
LVCMOS input voltage
VDD = 1.7 V; II = –18 mA
II
LVCMOS Input current
VI = 0 V or VDD; VDD = 1.9 V
IIH
LVCMOS Input current for S0/S1/S2
IIL
LVCMOS Input current for S0/S1/S2
Input capacitance at Xin/Clk
VIClk = 0 V or VDD
6
Input capacitance at Xout
VIXout = 0 V or VDD
2
Input capacitance at S0/S1/S2
VIS = 0 V or VDD
3
CI
–1.2
V
±5
μA
VI = VDD; VDD = 1.9 V
5
μA
VI = 0 V; VDD = 1.9 V
–4
μA
pF
CDCE913 - LVCMOS PARAMETER FOR VDDOUT = 3.3 V – MODE
VOH
LVCMOS high-level output voltage
VOL
LVCMOS low-level output voltage
VDDOUT = 3 V, IOH = –0.1 mA
2.9
VDDOUT = 3 V, IOH = –8 mA
2.4
VDDOUT = 3 V, IOH = –12 mA
2.2
V
VDDOUT = 3 V, IOL = 0.1 mA
0.1
VDDOUT = 3 V, IOL = 8 mA
0.5
VDDOUT = 3 V, IOL = 12 mA
0.8
V
tPLH, tPHL
Propagation delay
PLL bypass
3.2
tr/tf
Rise and fall time
VDDOUT = 3.3 V (20%–80%)
0.6
tjit(cc)
Cycle-to-cycle jitter (2)
1 PLL switching, Y2-to-Y3
50
70
ps
tjit(per)
Peak-to-peak period jitter (3)
1 PLL switching, Y2-to-Y3
60
100
ps
tsk(o)
Output skew
60
ps
odc
Output duty cycle
(4)
(3)
, See Table 2
(5)
fOUT = 50 MHz; Y1-to-Y3
fVCO = 100 MHz; Pdiv = 1
45%
ns
ns
55%
CDCE913 – LVCMOS PARAMETER for VDDOUT = 2.5 V – Mode
VOH
LVCMOS high-level output voltage
VOL
LVCMOS low-level output voltage
tPLH, tPHL
Propagation delay
tr/tf
Rise and fall time
tjit(cc)
Cycle-to-cycle jitter (2)
tjit(per)
VDDOUT = 2.3 V, IOH = –0.1 mA
2.2
VDDOUT = 2.3 V, IOH = –6 mA
1.7
VDDOUT = 2.3 V, IOH = –10 mA
1.6
V
VDDOUT = 2.3 V, IOL = 0.1 mA
0.1
VDDOUT = 2.3 V, IOL = 6 mA
0.5
VDDOUT = 2.3 V, IOL = 10 mA
0.7
V
PLL bypass
3.6
VDDOUT = 2.5 V (20%–80%)
0.8
1 PLL switching, Y2-to-Y3
50
70
ps
Peak-to-peak period jitter (3)
1 PLL switching, Y2-to-Y3
60
100
ps
tsk(o)
Output skew (4) , See Table 2
fOUT = 50 MHz; Y1-to-Y3
60
ps
odc
Output duty cycle (5)
fVCO = 100 MHz; Pdiv = 1
(1)
(2)
(3)
(4)
(5)
6
(3)
45%
ns
ns
55%
All typical values are at respective nominal VDD.
10000 cycles.
Jitter depends on configuration. Jitter data is for input frequency = 27 MHz, fVCO = 108 MHz, fOUT = 27 MHz (measured at Y2).
The tsk(o) specification is only valid for equal loading of each bank of outputs, and the outputs are generated from the same divider.
odc depends on output rise and fall time (tr/tf); data sampled on rising edge (tr)
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
DEVICE CHARACTERISTICS (continued)
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP (1)
MAX
UNIT
CDCEL913 — LVCMOS PARAMETER for VDDOUT = 1.8 V – Mode
VOH
LVCMOS high-level output voltage
VOL
LVCMOS low-level output voltage
VDDOUT = 1.7 V, IOH = –0.1 mA
1.6
VDDOUT = 1.7 V, IOH = –4 mA
1.4
VDDOUT = 1.7 V, IOH = –8 mA
1.1
V
VDDOUT = 1.7 V, IOL = 0.1 mA
0.1
VDDOUT = 1.7 V, IOL = 4 mA
0.3
VDDOUT = 1.7 V, IOL = 8 mA
0.6
V
tPLH, tPHL
Propagation delay
PLL bypass
2.6
tr/tf
Rise and fall time
VDDOUT = 1.8 V (20%–80%)
0.7
tjit(cc)
Cycle-to-cycle jitter
1 PLL switching, Y2-to-Y3
80
110
ps
tjit(per)
Peak-to-peak period jitter (7)
1 PLL switching, Y2-to-Y3
100
130
ps
tsk(o)
Output skew (8) , See Table 2
fOUT = 50 MHz; Y1-to-Y3
50
ps
odc
Output duty cycle (9)
fVCO = 100 MHz; Pdiv = 1
(6) (7)
45%
ns
ns
55%
SDA/SCL PARAMETER
VIK
SCL and SDA input clamp voltage
VDD = 1.7 V; II = –18 mA
–1.2
V
IIH
SCL and SDA input current
VI = VDD; VDD = 1.9 V
±10
μA
VIH
SDA/SCL input high voltage (10)
VIL
SDA/SCL input low voltage (10)
VOL
SDA low-level output voltage
IOL = 3 mA, VDD = 1.7 V
CI
SCL/SDA Input capacitance
VI = 0 V or VDD
(6)
(7)
(8)
(9)
(10)
0.7 VDD
V
0.3 VDD
3
V
0.2 VDD
V
10
pF
10000 cycles.
Jitter depends on configuration. Jitter data is for input frequency = 27 MHz, fVCO = 108 MHz, fOUT = 27 MHz (measured at Y2).
The tsk(o) specification is only valid for equal loading of each bank of outputs, and the outputs are generated from the same divider.
odc depends on output rise and fall time (tr/tf); data sampled on rising edge (tr)
SDA and SCL pins are 3.3 V tolerant.
PARAMETER MEASUREMENT INFORMATION
CDCE913
CDCEL913
1 kW
LVCMOS
1 kW
10 pF
Figure 1. Test Load
CDCE913
CDCEL913
LVCMOS
LVCMOS
Typical Driver
Impedance
~ 32 W
Series
Termination
~ 18 W
Line Impedance
Zo = 50 W
Figure 2. Test Load for 50-Ω Board Environment
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
7
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
TYPICAL CHARACTERISTICS
CDCE913, CDCEL913
SUPPLY CURRENT
vs
PLL FREQUENCY
CDCE913
OUTPUT CURRENT
vs
OUTPUT FREQUENCY
16
30
VDD = 1.8 V
14
3 Outputs on
12
20
IDDOUT - mA
IDD - Supply Current - mA
25
VDD = 1.8 V,
VDDOUT = 3.3 V,
no load
1 PLL on
15
10
1 Output on
8
6
10
4
all PLL off
5
2
0
10
60
110
160
fVCO - Frequency - MHz
all Outputs off
0
10
210
30
50 70 90 110 130 150 170 190 210 230
fOUT - Output Frequency - MHz
Figure 3.
Figure 4.
CDCEL913
OUTPUT CURRENT
vs
OUTPUT FREQUENCY
4.5
4
VDD = 1.8 V,
VDDOUT = 1.8 V,
no load
3 Outputs on
IDDOUT - mA
3.5
3
2.5
2
1 Output on
1.5
1
all Outputs off
0.5
0
10 30 50
70
90 110 130 150 170 190 210 230
fOUT - Output Frequency - MHz
Figure 5.
8
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
APPLICATION INFORMATION
CONTROL TERMINAL CONFIGURATION
The CDCE913/CDCEL913 has three user-definable control terminals (S0, S1, and S2) which allow external
control of device settings. They can be programmed to any of the following functions:
• Spread spectrum clocking selection → spread type and spread amount selection
• Frequency selection → switching between any of two user-defined frequencies
• Output state selection → output configuration and power down control
The user can predefine up to eight different control settings. Table 1 and Table 2 explain these settings.
Table 1. Control Terminal Definition
External Control Bits
PLL1 Setting
PLL Frequency
Selection
Control Function
SSC Selection
Y1Setting
Output Y2/Y3 Selection
Output Y1 and Power-Down Selection
Table 2. PLLx Setting (can be selected for each PLL individual) (1)
SSC Selection (Center/Down)
SSCx [3-bits]
Center
Down
0
0
0
0% (off)
0% (off)
0
0
1
±0.25%
–0.25%
0
1
0
±0.5%
–0.5%
0
1
1
±0.75%
–0.75%
1
0
0
±1.0%
–1.0%
1
0
1
±1.25%
–1.25%
1
1
0
±1.5%
–1.5%
1
1
1
±2.0%
–2.0%
FREQUENCY SELECTION (2)
FSx
FUNCTION
0
Frequency0
1
Frequency1
OUTPUT SELECTION (3) (Y2 ... Y3)
(1)
(2)
(3)
YxYx
FUNCTION
0
State0
1
State1
Center/Down-Spread, Frequency0/1 and State0/1 are user-definable in PLLx Configuration Register;
Frequency0 and Frequency1 can be any frequency within the specified fVCO range.
State0/1 selection is valid for both outputs of the corresponding PLL module and can be power down,
3-state, low or active
Table 3. Y1 Setting (1)
Y1 SELECTION
(1)
Y1
FUNCTION
0
State 0
1
State 1
State0 and State1 are user definable in Generic Configuration
Register and can be power down, 3-state, low, or active.
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
9
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
S1/SDA and S2/SCL pins of the CDCE913/CDCEL913 are dual function pins. In default configuration they are
defined as SDA/SCL for the serial programming interface. They can be programmed as control-pins (S1/S2) by
setting the appropriate bits in the EEPROM. Note that the changes to the Control Register (Bit [6] of Byte 02h)
have no effect until they are written into the EEPROM.
Once they are set as control pins, the serial programming interface is no longer available. However, if VDDOUT is
forced to GND, the two control pins, S1 and S2, temporally act as serial programming pins (SDA/SCL).
S0 is not a multi use pin; it is a control pin only.
DEFAULT DEVICE CONFIGURATION
The internal EEPROM of CDCE913/CDCEL913 is pre-configured with a factory default configuration as shown in
Figure 6 (The input frequency is passed through the output as a default).This allows the device to operate in
default mode without the extra production step of programming it. The default setting appears after power is
supplied or after power-down/up sequence until it is reprogrammed by the user to a different application
configuration. A new register setting is programmed via the serial SDA/SCL Interface.
VDD
VDDOUT
GND
1 = Output Enabled
0 = Output 3-State
EEPROM
Programming
and
SDA/SCL
Register
S0
Programming Bus
SDA
SCL
Pdiv2 = 1
Y2 = 27 MHz
LV
CMOS
Y3 = 27 MHz
MUX1
Xout
LV
CMOS
Pdiv1 =1
X-tal
PLL 1
power down
Y1 = 27 MHz
M2
27 MHz
Crystal
LV
CMOS
M3
M1
Input Clock
Xin
PLL Bypass
Pdiv3 = 1
Figure 6. Default Configuration
A different default setting can be programmed upon customer request. Contact Texas Instruments sales or
marketing representative for more information.
Table 4 shows the factory default setting for the Control Terminal Register. Note that even though 8 different
register settings are possible, in default configuration, only the first two settings (0 and 1) can be selected with
S0, as S1 and S2 are configured as programming pins in default mode.
Table 4. Factory Default Setting for Control Terminal Register (1)
Y1
External Control Pins
PLL1 Settings
Output Selection
Frequency Selection
SSC Selection
Output Selection
Y1
FS1
SSC1
Y2Y3
S2
S1
S0
SCL (I2C)
SDA (I2C)
0
3-state
fVCO1_0
off
3-state
SCL (I2C)
SDA (I2C)
1
enabled
fVCO1_0
off
enabled
(1)
In default mode or when programmed respectively, S1 and S2 act as serial programming interface, SDA/SCL. They do not have any
control-pin function but they are internally interpreted as if S1=0 and S2=0. S0, however, is a control-pin which in the default mode
switches all outputs ON or OFF (as previously predefined).
SDA/SCL SERIAL INTERFACE
The CDCE913/CDCEL913 operates as a slave device of the 2-wire serial SDA/SCL bus, compatible with the
popular SMBus or I2C specification. It operates in the standard-mode transfer (up to 100kbit/s) and fast-mode
transfer (up to 400kbit/s) and supports 7-bit addressing.
The S1/SDA and S2/SCL pins of the CDCE913/CDCEL913 are dual function pins. In the default configuration
they are used as SDA/SCL serial programming interface. They can be re-programmed as general purpose
control pins, S1 and S2, by changing the corresponding EEPROM setting, Byte 02h, Bit [6].
10
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
DATA PROTOCOL
The device supports Byte Write and Byte Read and Block Write and Block Read operations.
For Byte Write/Read operations, the system controller can individually access addressed bytes.
For Block Write/Read operations, the bytes are accessed in sequential order from lowest to highest byte (with
most significant bit first) with the ability to stop after any complete byte has been transferred. The numbers of
Bytes read-out are defined by Byte Count in the Generic Configuration Register. At Block Read instruction, all
bytes defined in the Byte Count must be readout to correctly finish the read cycle.
Once a byte has been sent, it is written into the internal register and is effective immediately. This applies to
each transferred byte regardless of whether this is a Byte Write or a Block Write sequence.
If the EEPROM Write Cycle is initiated, the internal SDA registers are written into the EEPROM. During this Write
Cycle, data is not accepted at the SDA/SCL bus until the write cycle is completed. However, data can be read
out during the programming sequence (Byte Read or Block Read). The programming status can be monitored by
EEPIP, byte 01h–bit 6.
The offset of the indexed byte is encoded in the command code, as described in Table 5.
Table 5. Slave Receiver Address (7 Bits)
A6
A5
A4
A3
A2
A1 (1)
A0 (1)
R/W
CDCE913/CDCEL913
1
1
0
0
1
0
1
1/0
CDCE925/CDCEL925
1
1
0
0
1
0
0
1/0
CDCE937/CDCEL937
1
1
0
1
1
0
1
1/0
CDCE949/CDCEL949
1
1
0
1
1
0
0
1/0
DEVICE
(1)
Address bits A0 and A1 are programmable via the SDA/SCL bus (byte 01, bit [1:0]. This allows addressing up to 4 devices connected to
the same SDA/SCL bus. The least-significant bit of the address byte designates a write or read operation.
COMMAND CODE DEFINITION
Table 6. Command Code Definition
BIT
7
(6:0)
DESCRIPTION
0 = Block Read or Block Write operation
1 = Byte Read or Byte Write operation
Byte Offset for Byte Read, Block Read, Byte Write and Block Write operation.
Generic Programming Sequence
1
S
7
Slave Address
MSB
LSB
S
Start Condition
Sr
Repeated Start Condition
R/W
1
R/W
1
A
8
Data Byte
1
A
MSB
1
P
LSB
1 = Read (Rd) From CDCE9xx Device; 0 = Write (Wr) to CDCE9xxx
A
Acknowledge (ACK = 0 and NACK =1)
P
Stop Condition
Master-to-Slave Transmission
Slave-to-Master Transmission
Figure 7. Generic Programming Sequence
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
11
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
Byte Write Programming Sequence
1
S
7
Slave Address
1
Wr
1
A
8
CommandCode
1
A
8
Data Byte
1
A
1
P
7
Slave Address
1
Rd
1
A
1
A
1
P
Figure 8. Byte Write Protocol
Byte Read Programming Sequence
1
S
7
Slave Address
1
Wr
1
A
8
Data Byte
1
A
1
P
1
A
8
CommandCode
1
S
Figure 9. Byte Read Protocol
Block Write Programming Sequence(1)
1
S
(1)
7
Slave Address
1
Wr
8
Data Byte 0
1
A
1
A
8
CommandCode
8
Data Byte 1
1
A
1
A
8
Byte Count = N
1
A
8
Data Byte N-1
…
Data byte 0 bits [7:0] is reserved for Revision Code and Vendor Identification. Also, it is used for internal test purpose
and should not be overwritten.
Figure 10. Block Write Protocol
Block Read Programming Sequence
1
S
7
Slave Address
1
Wr
8
Byte Count N
1
A
1
A
8
CommandCode
8
Data Byte 0
1
A
1
A
1
Sr
…
7
Slave Address
1
Rd
1
A
8
Data Byte N-1
1
A
1
P
Figure 11. Block Read Protocol
Timing Diagram for the SDA/SCL Serial Control Interface
P
S
tw(SCLL)
Bit 7 (MSB)
tw(SCLH)
Bit 6
tr
Bit 0 (LSB)
A
P
tf
VIH
SCL
VIL
tsu(START)
th(START)
tsu(SDA)
th(SDA)
t(BUS)
tr
tsu(STOP)
tf
VIH
SDA
VIL
Figure 12. Timing Diagram for SDA/SCL Serial Control Interface
12
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
SDA/SCL HARDWARE INTERFACE
Figure 13 shows how the CDCE913/CDCEL913 clock synthesizer is connected to the SDA/SCL serial interface
bus. Multiple devices can be connected to the bus but the speed may need to be reduced (400 kHz is the
maximum) if many devices are connected.
Note that the pullup resistors (RP) depends on the supply voltage, bus capacitance, and number of connected
devices. The recommended pullup value is 4.7 kΩ. It must meet the minimum sink current of 3 mA at
VOLmax = 0.4 V for the output stages (for more details see the SMBus or I2C™ Bus specification).
CDCE913
CDCEL913
RP
RP
Master
Slave
SDA
SCL
CBUS
CBUS
Figure 13. SDA / SCL Hardware Interface
SDA/SCL CONFIGURATION REGISTERS
The clock input, control pins, PLLs, and output stages are user configurable. The following tables and
explanations describe the programmable functions of the CDCE913/CDCEL913. All settings can be manually
written into the device via the SDA/SCL bus or easily programmed by using the TI Pro-Clock™ software. TI
Pro-Clock™ software allows the user to quickly make all settings and automatically calculates the values for
optimized performance at lowest jitter.
Table 7. SDA/SCL Registers
Address Offset
Register Description
Table
00h
Generic Configuration Register
Table 9
10h
PLL1 Configuration Register
Table 10
The grey-highlighted bits, described in the Configuration Registers tables in the following pages, belong to the
Control Terminal Register. The user can predefine up to eight different control settings. These settings then can
be selected by the external control pins, S0, S1, and S2. See the Control Terminal Configuration section.
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
13
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
Table 8. Configuration Register,
External Control Terminals
Y1
External Control
Pins
14
Output Selection
Frequency Selection
SSC Selection
Output Selection
S2
S1
S0
Y1
FS1
SSC1
Y2Y3
0
0
0
0
Y1_0
FS1_0
SSC1_0
Y2Y3_0
1
0
0
1
Y1_1
FS1_1
SSC1_1
Y2Y3_1
2
0
1
0
Y1_2
FS1_2
SSC1_2
Y2Y3_2
3
0
1
1
Y1_3
FS1_3
SSC1_3
Y2Y3_3
4
1
0
0
Y1_4
FS1_4
SSC1_4
Y2Y3_4
5
1
0
1
Y1_5
FS1_5
SSC1_5
Y2Y3_5
6
1
1
0
Y1_6
FS1_6
SSC1_6
Y2Y3_6
7
1
1
1
Y1_7
FS1_7
SSC1_7
Y2Y3_7
04h
13h
10h–12h
15h
Address Offset (1)
(1)
PLL1 Settings
Address Offset refers to the byte address in the Configuration Register in Table 9 and Table 10.
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
Table 9. Generic Configuration Register
Offset
00h
(1)
Bit
(2)
Acronym
Default
(3)
Description
7
E_EL
Xb
Device identification (read-only): 1 is CDCE913 (3.3 V out), 0 is CDCEL913 (1.8 V out)
6:4
RID
0h
Revision Identification Number (read only)
3:0
VID
1h
Vendor Identification Number (read only)
7
–
0b
Reserved – always write 0
6
EEPIP
0b
EEPROM Programming Status4: (4) (read only)
0 – EEPROM programming is completed
1 – EEPROM is in programming mode
5
EELOCK
0b
Permanently Lock EEPROM Data (5)
0 – EEPROM is not locked
1 – EEPROM will be permanently locked
4
PWDN
0b
3:2
INCLK
00b
Device Power Down (overwrites S0/S1/S2 setting; configuration register settings are unchanged)
01h
0 – device active (PLL1 and all outputs are enabled)
1 – device power down (PLL1 in power down and all outputs in 3-state)
00 – Xtal
10 – LVCMOS
01 – VCXO
11 – reserved
Input clock selection:
1:0
SLAVE_ADR
01b
Address Bits A0 and A1 of the Slave Receiver Address
7
M1
1b
Clock source selection for output Y1:
0 – input clock
1 – PLL1 clock
Operation mode selection for pin 12/13 (6)
02h
6
SPICON
0b
5:4
Y1_ST1
11b
3:2
Y1_ST0
01b
1:0
Pdiv1 [9:8]
7:0
Pdiv1 [7:0]
7
Y1_7
0b
6
Y1_6
0b
5
Y1_5
0b
4
Y1_4
0b
3
Y1_3
0b
2
Y1_2
0b
1
Y1_1
1b
0
Y1_0
0b
001h
03h
04h
0 – serial programming interface SDA (pin 13) and SCL (pin 12)
1 – control pins S1 (pin 13) and S2 (pin 12)
Y1-State0/1 Definition
00 – device power down (all PLLs in power down and all
outputs in 3-State)
01 – Y1 disabled to 3-state
10-Bit Y1-Output-Divider Pdiv1:
0 – divider reset and stand-by
1-to-1023 – divider value
Y1_x State Selection (7)
0 – State0 (predefined by Y1_ST0)
1 – State1 (predefined by Y1_ST1)
Crystal Load Capacitor Selection (8)
7:3
XCSEL
10 – Y1 disabled to low
11 – Y1 enabled
0Ah
05h
00h → 0 pF
01h → 1 pF
02h → 2 pF
:14h-to-1Fh → 20 pF
Vctr
Xin
20pF
i.e.
XCSEL = 10pF
XO
Xout
2:0
0b
Reserved – do not write other than 0
VCXO
20pF
7:1
BCOUNT
20h
7-Bit Byte Count (defines the number of bytes which will be sent from this device at the next Block Read transfer); all bytes
have to be read out to correctly finish the read cycle.
0
EEWRITE
0b
Initiate EEPROM Write Cycle
06h
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(4) (9)
0– no EEPROM write cycle
1 – start EEPROM write cycle (internal register are saved to the EEPROM)
Writing data beyond ‘20h’ may affect device function.
All data transferred with the MSB first.
Unless customer-specific setting.
During EEPROM programming, no data is allowed to be sent to the device via the SDA/SCL bus until the programming sequence is
completed. Data, however, can be read out during the programming sequence (Byte Read or Block Read).
If this bit is set to high in the EEPROM, the actual data in the EEPROM is permanently locked. No further programming is possible.
Data, however can still be written via SDA/SCL bus to the internal register to change device function on the fly. But new data can no
longer be saved to the EEPROM. EELOCK is effective only, if written into the EEPROM.
Selection of “control pins” is effective only if written into the EEPROM. Once written into the EEPROM, the serial programming pins are
no longer available. However, if VDDOUT is forced to GND, the two control pins, S1 and S2, temporally act as serial programming pins
(SDA/SCL), and the two slave receiver address bits are reset to A0=”0” and A1=“0”.
These are the bits of the Control Terminal Register (see Table 8). The user can predefine up to eight different control settings. These
settings then can be selected by the external control pins, S0, S1, and S2.
The internal load capacitor (C1, C2) has to be used to achieve the best clock performance. External capacitors should be used only to
finely adjust CL by a few picofarads. The value of CL can be programmed with a resolution of 1 pF for a crystal load range of 0 pF to 20
pF. For CL > 20 pF, use additional external capacitors. Also, the value of the device input capacitance has to be considered which
always adds 1.5 pF (6 pF//2 pF) to the selected CL. For more information about VCXO configuration and crystal recommendation, see
application report SCAA085.
The EEPROM WRITE bit must be sent last. This ensures that the content of all internal registers are stored in the EEPROM. The
EEWRITE cycle is initiated with the rising edge of the EEWRITE bit. A static level high does not trigger an EEPROM WRITE cycle. The
EEWRITE bit has to be reset to low after the programming is completed. The programming status can be monitored by reading out
EEPIP. If EELOCK is set to high, no EEPROM programming is possible.
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
15
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
Table 9. Generic Configuration Register (continued)
Offset (1)
Bit (2)
Acronym
Default (3)
—
0h
07h-0Fh
Description
Unused address range
Table 10. PLL1 Configuration Register
OFFSET
10h
11h
12h
13h
14h
15h
(1)
(2)
(3)
(4)
16
(1)
Acronym
Default (3)
7:5
SSC1_7 [2:0]
000b
4:2
SSC1_6 [2:0]
000b
1:0
SSC1_5 [2:1]
7
SSC1_5 [0]
6:4
SSC1_4 [2:0]
000b
3:1
SSC1_3 [2:0]
000b
0
SSC1_2 [2]
7:6
SSC1_2 [1:0]
5:3
SSC1_1 [2:0]
000b
2:0
SSC1_0 [2:0]
000b
7
FS1_7
0b
6
FS1_6
0b
5
FS1_5
0b
4
FS1_4
0b
3
FS1_3
0b
2
FS1_2
0b
1
FS1_1
0b
0
FS1_0
0b
7
MUX1
1b
PLL1 Multiplexer:
0 – PLL1
1 – PLL1 Bypass (PLL1 is in power down)
6
M2
1b
Output Y2 Multiplexer:
0 – Pdiv1
1 – Pdiv2
5:4
M3
10b
Output Y3 Multiplexer:
00 – Pdiv1-Divider
01 – Pdiv2-Divider
10 – Pdiv3-Divider
11 – reserved
3:2
Y2Y3_ST1
11b
Y2, Y3-State0/1definition:
00 – Y2/Y3 disabled to 3-State (PLL1 is in power down)
01 – Y2/Y3 disabled to 3-State
10–Y2/Y3 disabled to low
11 – Y2/Y3 enabled
Bit
(2)
000b
000b
1:0
Y2Y3_ST0
01b
7
Y2Y3_7
0b
6
Y2Y3_6
0b
5
Y2Y3_5
0b
4
Y2Y3_4
0b
3
Y2Y3_3
0b
2
Y2Y3_2
0b
1
Y2Y3_1
1b
0
Y2Y3_0
0b
DESCRIPTION
SSC1: PLL1 SSC Selection (Modulation Amount) (4)
Down
000 (off)
001 – 0.25%
010 – 0.5%
011 – 0.75%
100 – 1.0%
101 – 1.25%
110 – 1.5%
111 – 2.0%
Center
000 (off)
001 ± 0.25%
010 ± 0.5%
011 ± 0.75%
100 ± 1.0%
101 ± 1.25%
110 ± 1.5%
111 ± 2.0%
FS1_x: PLL1 Frequency Selection (4)
0 – fVCO1_0 (predefined by PLL1_0 – Multiplier/Divider value)
1 – fVCO1_1 (predefined by PLL1_1 – Multiplier/Divider value)
Y2Y3_x Output State Selection
(4)
0 – state0 (predefined by Y2Y3_ST0)
1 – state1 (predefined by Y2Y3_ST1)
Writing data beyond 20h may adversely affect device function.
All data is transferred MSB-first.
Unless a custom setting is used
The user can predefine up to eight different control settings. In normal device operation, these settings can be selected by the external
control pins, S0, S1, and S2.
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
Table 10. PLL1 Configuration Register (continued)
OFFSET (1)
Bit (2)
Acronym
Default (3)
DESCRIPTION
7
SSC1DC
0b
PLL1 SSC down/center selection:
0 – down
1 – center
6:0
Pdiv2
01h
7-Bit Y2-Output-Divider Pdiv2:
0 – reset and stand-by
1-to-127 is divider value
7
—
0b
Reserved – do not write others than 0
6:0
Pdiv3
01h
7-Bit Y3-Output-Divider Pdiv3:
7:0
PLL1_0N [11:4]
7:4
PLL1_0N [3:0]
3:0
PLL1_0R [8:5]
7:3
PLL1_0R[4:0]
2:0
PLL1_0Q [5:3]
7:5
PLL1_0Q [2:0]
4:2
PLL1_0P [2:0]
010b
1:0
VCO1_0_RANGE
00b
7:0
PLL1_1N [11:4]
7:4
PLL1_1N [3:0]
3:0
PLL1_1R [8:5]
7:3
PLL1_1R[4:0]
2:0
PLL1_1Q [5:3]
7:5
PLL1_1Q [2:0]
4:2
PLL1_1P [2:0]
010b
1:0
VCO1_1_RANGE
00b
16h
17h
18h
19h
1Ah
004h
000h
PLL1_0: 30-Bit Multiplier/Divider value for frequency fVCO1_0
(for more information, see paragraph PLL Multiplier/Divider Definition).
10h
1Bh
1Ch
1Dh
1Eh
1Fh
0 – reset and stand-by
1-to-127 is divider value
fVCO1_0 range selection:
00 – fVCO1_0 < 125 MHz
01 – 125 MHz ≤ fVCO1_0 < 150 MHz
10 – 150 MHz ≤ fVCO1_0 < 175 MHz
11 – fVCO1_0 ≥ 175 MHz
004h
000h
PLL1_1: 30-Bit Multiplier/Divider value for frequency fVCO1_1
(for more information see paragraph PLL Multiplier/Divider Definition)
10h
fVCO1_1 range selection:
00 – fVCO1_1 < 125 MHz
01 – 125 MHz ≤ fVCO1_1 < 150 MHz
10 – 150 MHz ≤ fVCO1_1 < 175 MHz
11 – fVCO1_1 ≥ 175 MHz
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
17
CDCE913
CDCEL913
www.ti.com
SCAS849A – JUNE 2007 – REVISED AUGUST 2007
PLL Multiplier/Divider Definition
At a given input frequency (ƒIN), the output frequency (ƒOUT) of the CDCE913/CDCEL913 can be calculated:
ƒ
N
ƒ OUT + IN
Pdiv M
(1)
where
M (1 to 511) and N (1 to 4095) are the multiplier/divide values of the PLL; Pdiv (1 to 127) is the output
divider.
The target VCO frequency (ƒVCO) of each PLL can be calculated:
N
ƒ VCO + ƒIN
M
(2)
The PLL internally operates as fractional divider and needs the following multiplier/divider settings:
• N
•
•
•
ǒ
log N Ǔ [if P t 0 then P + 0]
M
P = 4 – int
NȀǓ
ǒ
Q = int M
2
R = N′ – M × Q
where
N′ = N × 2P;
N ≥ M;
100 MHz < ƒVCO > 200 MHz.
Example:
for ƒIN = 27 MHz; M = 1; N = 4; Pdiv = 2;
for ƒIN = 27 MHz; M = 2; N = 11; Pdiv = 2;
→ fOUT = 54 MHz
→ fOUT = 74.25 MHz
→ fVCO = 108 MHz
→ fVCO = 148.50 MHz
→ P = 4 – int(log24) = 4 – 2 = 2
→ P = 4 – int(log25.5) = 4 – 2 = 2
→ N′’ = 4 × 2 = 16
→ N′’ = 11 × 22 = 44
→ Q = int(16) = 16
→ Q = int(22) = 22
→ R = 16 – 16 = 0
→ R = 44 – 44 = 0
2
The values for P, Q, R, and N’ are automatically calculated when using TI Pro-Clock™ software.
18
Submit Documentation Feedback
Copyright © 2007, Texas Instruments Incorporated
Product Folder Link(s): CDCE913 CDCEL913
PACKAGE OPTION ADDENDUM
www.ti.com
13-Aug-2007
PACKAGING INFORMATION
Orderable Device
Status (1)
Package
Type
Package
Drawing
Pins Package Eco Plan (2)
Qty
Lead/Ball Finish
MSL Peak Temp (3)
CDCE913PW
PREVIEW
TSSOP
PW
14
90
TBD
Call TI
Call TI
CDCE913PWR
PREVIEW
TSSOP
PW
14
2000
TBD
Call TI
Call TI
CDCEL913PW
PREVIEW
TSSOP
PW
14
90
TBD
Call TI
Call TI
CDCEL913PWR
PREVIEW
TSSOP
PW
14
2000
TBD
Call TI
Call TI
(1)
The marketing status values are defined as follows:
ACTIVE: Product device recommended for new designs.
LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect.
NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in
a new design.
PREVIEW: Device has been announced but is not in production. Samples may or may not be available.
OBSOLETE: TI has discontinued the production of the device.
(2)
Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check
http://www.ti.com/productcontent for the latest availability information and additional product content details.
TBD: The Pb-Free/Green conversion plan has not been defined.
Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements
for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered
at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes.
Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and
package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS
compatible) as defined above.
Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame
retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material)
(3)
MSL, Peak Temp. -- The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder
temperature.
Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is
provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the
accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take
reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on
incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited
information may not be available for release.
In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI
to Customer on an annual basis.
Addendum-Page 1
MECHANICAL DATA
MTSS001C – JANUARY 1995 – REVISED FEBRUARY 1999
PW (R-PDSO-G**)
PLASTIC SMALL-OUTLINE PACKAGE
14 PINS SHOWN
0,30
0,19
0,65
14
0,10 M
8
0,15 NOM
4,50
4,30
6,60
6,20
Gage Plane
0,25
1
7
0°– 8°
A
0,75
0,50
Seating Plane
0,15
0,05
1,20 MAX
PINS **
0,10
8
14
16
20
24
28
A MAX
3,10
5,10
5,10
6,60
7,90
9,80
A MIN
2,90
4,90
4,90
6,40
7,70
9,60
DIM
4040064/F 01/97
NOTES: A.
B.
C.
D.
All linear dimensions are in millimeters.
This drawing is subject to change without notice.
Body dimensions do not include mold flash or protrusion not to exceed 0,15.
Falls within JEDEC MO-153
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements,
improvements, and other changes to its products and services at any time and to discontinue any product or service without notice.
Customers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment.
TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI’s
standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this
warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily
performed.
TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and
applications using TI components. To minimize the risks associated with customer products and applications, customers should
provide adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask
work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services
are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such
products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under
the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is
accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an
unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties
may be subject to additional restrictions.
Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service
voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business
practice. TI is not responsible or liable for any such statements.
TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would
reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement
specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications
of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related
requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any
applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its
representatives against any damages arising out of the use of TI products in such safety-critical applications.
TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are
specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military
specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is
solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in
connection with such use.
TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products
are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any
non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements.
Following are URLs where you can obtain information on other Texas Instruments products and application solutions:
Products
Applications
Amplifiers
amplifier.ti.com
Audio
www.ti.com/audio
Data Converters
dataconverter.ti.com
Automotive
www.ti.com/automotive
DSP
dsp.ti.com
Broadband
www.ti.com/broadband
Interface
interface.ti.com
Digital Control
www.ti.com/digitalcontrol
Logic
logic.ti.com
Military
www.ti.com/military
Power Mgmt
power.ti.com
Optical Networking
www.ti.com/opticalnetwork
Microcontrollers
microcontroller.ti.com
Security
www.ti.com/security
RFID
www.ti-rfid.com
Telephony
www.ti.com/telephony
Low Power
Wireless
www.ti.com/lpw
Video & Imaging
www.ti.com/video
Wireless
www.ti.com/wireless
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2007, Texas Instruments Incorporated
Similar pages