Delta H24SN12029NNFB Delphi series h24sn, 350w half brick family dc/dc power modules: 18~36vin, 28v/12.5a out Datasheet

FEATURES
High Efficiency: 90.5% @ 28V/12.5A
Size: 61.0x57.9x12.7mm (2.40”×2.28”×0.50”)
Standard footprint
Industry standard pin out
Fixed frequency operation
Metal baseplate
Input UVLO, Output OCP, OVP, OTP
Basic insulation
2250V isolation
2:1 Input voltage range
ISO 9001, TL 9000, ISO 14001, QS 9000,
OHSAS 18001 certified manufacturing facility
UL/cUL 60950 (US & Canada) recognized,
and TUV (EN60950) certified
CE mark meets 73/23/EEC and 93/68/EEC
directive
Delphi Series H24SN, 350W Half Brick Family
DC/DC Power Modules: 18~36Vin, 28V/12.5A out
The Delphi Series H24SN Half Brick, 24V input, single output, isolated
DC/DC converters are the latest offering from a world leader in power
systems technology and manufacturing -- Delta Electronics, Inc. This
product family provides up to 350 watts of power in an industry
standard footprint. Typical full load efficiency for 24Vin, 28V output is
90.5%. With creative design technology and optimization of component
placement, these converters possess outstanding electrical and
thermal performance, as well as extremely high reliability under highly
stressful operating conditions. All models are fully protected from
abnormal input/output voltage, current, and temperature conditions.
The Delphi Series converters meet all safety requirements with basic
insulation. A variety of optional heatsinks are available for extended
thermal operation, as well as for use in higher air flow applications: 200
to 400 LFM.
OPTIONS
Positive on/off logic
Short pin length
APPLICATIONS
Telecom/Datacom
Wireless Networks
Optical Network Equipment
Server and Data Storage
Industrial/Test Equipment
DATASHEET
DS_H24SN28012_07272006
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=300 LFM, Vin=24Vdc, nominal Vout unless otherwise noted.)
PARAMETER
H24SN28012NRFA
NOTES and CONDITIONS
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Transient (100ms)
Operating Temperature
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
Minimum -Load Input Current
Off Converter Input Current
Inrush Current(I2t)
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Load
Over Line
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output DC Current-Limit Inception
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time (within 1% Vout nominal)
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
Output Capacitive Load
EFFICIENCY
100% Load
60% Load
ISOLATION CHARACTERISTICS
Input to Output
Input to Case
Output to Case
Isolation Resistance
Isolation Capacitance
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control Negative Remote On/Off logic
Logic Low (Module On)
Logic High (Module Off)
ON/OFF Control, Positive Remote On/Off logic
Logic Low (Module Off)
Logic High (Module On)
ON/OFF Current
Leakage Current
Output Voltage Trim Range
Output Voltage Remote Sense Range
Output Over-Voltage Protection
GENERAL SPECIFICATIONS
MTBF
Weight
Over-Temperature Shutdown
100ms
Refer to Fig.20 for measuring point
Typ.
-40
-55
Vdc
Vdc
°C
°C
Vdc
36
Vdc
17.5
16.5
1
18
15.5
Vdc
Vdc
Vdc
A
mA
mA
A2s
mA
dB
24
500
15
0.5
30
60
2
27.72
28.00
28.28
Vdc
27.25
±20
±20
±250
28.00
±56
±112
±300
28.75
mV
mV
mV
V
60
14
150
40
12.5
120
mV
mV
A
%
400
400
300
mV
mV
us
30
30
ms
ms
µF
0.3
Output Voltage 10% Low
24V, Tested with a aluminum ,10µF Low ESR cap
and 1µF Ceramic load cap, ΔIo/Δt=1A/µs
50% Io.max to 75% Io.max
75% Io.max to 50% Io.max
Full load; 5% overshoot of Vout at startup
40
50
115
125
2250
24
P-P thru 12µH inductor, 5Hz to 20MHz
120 Hz
Io=Io,min to Io,max
Vin=18V to 36V
Tc=-40°C to 100°C
over sample load, line and temperature
5Hz to 20MHz bandwidth
Full Load, 1µF ceramic, 10µF Low ESR cap
Full Load, 1µF ceramic, 10µF Low ESR cap
Units
18
100% Load, 18Vin
Vin=48V, Io=Io.max, Tc=25°C
Max.
330
5000
90.5
91.0
%
%
2250
2250
500
1900
Vdc
Vdc
Vdc
MΩ
pF
330
kHz
10
Von/off at Ion/off=1.0mA
Von/off at Ion/off=0.0 µA
Von/off at Ion/off=1.0mA
Von/off at Ion/off=0.0 µA
Ion/off at Von/off=0.0V
Logic High, Von/off=15V
Across Pins 9 & 5, Pout ≦ max rated power
Pout ≦ max rated power
Over full temp range; % of nominal Vout
Io=80% of Io, max; Ta=25°C
Refer to Fig.20 for measuring point
0
0.8
15
V
V
0
0.8
15
1
50
+10
0.5
140
V
V
mA
uA
%
V
%
-40
115
2.19
62
120
M hours
grams
°C
H24SN28012_07272006
2
ELECTRICAL CHARACTERISTICS CURVES
Figure 1: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C.
Figure 2: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
Figure 3: Input current vs. output current at low line, nominal
line, and high line.
Figure 4: Typical input characteristics at room temperature
H24SN28012_07272006
3
ELECTRICAL CHARACTERISTICS CURVES
For Negative Remote On/Off Logic
Figure 5: Turn-on transient at full rated load current (resistive
load) (5ms/div). CH2: Vout; 10V/div; CH3: ON/OFF input:
5V/div
Figure 6: Turn-on transient at minimum load current
(5ms/div). CH2: Vout: 10V/div; CH3: ON/OFF input: 5V/div
H24SN28012_07272006
4
ELECTRICAL CHARACTERISTICS CURVES
Figure 7: Output voltage response to step-change in load
current (75%-50% of Io, max; di/dt = 1A/µs). Load cap: 330µF
aluminum ,10uF Low ESR capacitor and 1µF ceramic
capacitor. Top Trace: Vout (100mV/div), Bottom Trace: Iout
(1A/div). Scope measurement should be made using a BNC
cable (length shorter than 20 inches). Position the load
between 51 mm to 76 mm (2 inches to 3 inches) from the
module.
Figure 8: Output voltage response to step-change in load
current (50%-75% of Io, max; di/dt = 1A/µs). Load cap: 330µF
aluminum,10uF Low ESR capacitor and 1µF ceramic capacitor.
Top Trace: Vout (100mV/div), Bottom Trace: Iout (1A/div).
Scope measurement should be made using a BNC cable
(length shorter than 20 inches). Position the load between 51
mm to 76 mm (2 inches to 3 inches) from the module.
Figure 9: Test set-up diagram showing measurement points for
Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (LTEST) of 12 µH. Capacitor Cs offset
possible battery impedance. Measure current as shown above.
H24SN28012_07272006
5
ELECTRICAL CHARACTERISTICS CURVES
Figure 10: Input Terminal Ripple Current, ic, at full rated output
current and nominal input voltage with 12µH source impedance
and 220µF electrolytic capacitor (1A/div).
Figure 11: Input reflected ripple current, is, through a 12µH
source inductor at nominal input voltage and rated load current
(10 mA/div)
Copper Strip
Vo(+)
10u
1u
SCOPE
RESISTIVE
LOAD
Vo(-)
Figure 12: Output voltage noise and ripple measurement test
setup
H24SN28012_07272006
6
ELECTRICAL CHARACTERISTICS CURVES
Figure 13: Output voltage ripple at nominal input voltage and
rated load current (50 mV/div). Load capacitance:330uF
aluminum, 1µF ceramic capacitor and 10µFlow ESR capacitor.
Bandwidth: 20 MHz. Scope measurement should be made
using a BNC cable (length shorter than 20 inches). Position the
load between 51 mm to 76 mm (2 inches to 3 inches) from the
module.
Figure 14: Output voltage vs. load current showing typical
current limit curves and converter shutdown points.
H24SN28012_07272006
7
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules
and affect the stability. A low ac-impedance input source
is recommended. If the source inductance is more than
a few µH, we advise adding a 220 to 470 µF electrolytic
capacitor (ESR < 0.1 Ω at 100 kHz) mounted close to
the input of the module to improve the stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate
in a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB
layout issues, please contact Delta’s technical support
team. An external input filter module is available for
easier EMC compliance design. Application notes to
assist designers in addressing these issues are pending
release.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950,
CAN/CSA-C22.2 No. 60950-00 and EN60950:2000 and
IEC60950-1999, if the system in which the power
module is to be used must meet safety agency
requirements.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2
or SELV. An additional evaluation is needed if the
source is other than TNV-2 or SELV.
When the input source is SELV, the power module meets
SELV (safety extra-low voltage) requirements. If the
input source is a hazardous voltage which is greater than
60 Vdc and less than or equal to 75 Vdc, for the module’s
output to meet SELV requirements, all of the following
must be met:
The input source must be insulated from the ac
mains by reinforced or double insulation.
The input terminals of the module are not operator
accessible.
If the metal baseplate is grounded, one Vi pin and
one Vo pin shall also be grounded.
A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been evaluated.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line fuse
is highly recommended. The safety agencies require a
normal-blow fuse with 20A maximum rating to be
installed in the ungrounded lead. A lower rated fuse can
be used based on the maximum inrush transient energy
and maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes electrical
testing. Inadequate cleaning and/or drying may lower the
reliability of a power module and severely affect the
finished circuit board assembly test. Adequate cleaning
and/or drying is especially important for un-encapsulated
and/or open frame type power modules. For assistance
on appropriate soldering and cleaning procedures,
please contact Delta’s technical support team.
H24SN28012_07272006
8
FEATURES DESCRIPTIONS
Vi(+)
Over-Current Protection
Sense(+)
The modules include an internal output over-current
protection circuit, which will endure current limiting for
an unlimited duration during output overload. If the
output current exceeds the OCP set point, the modules
will automatically shut down (hiccup mode).
The modules will try to restart after shutdown. If the
overload condition still exists, the module will shut down
again. This restart trial will continue until the overload
condition is corrected.
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. If this voltage exceeds the over-voltage
set point, the module will shut down and latch off. The
over-voltage latch is reset by either cycling the input
power or by toggling the on/off signal for one second.
Over-Temperature Protection
ON/OFF
Sense(-)
Vi(-)
Remote Sense
Remote sense compensates for voltage drops on the
output by sensing the actual output voltage at the point
of load. The voltage between the remote sense pins
and the output terminals must not exceed the output
voltage sense range given here:
[Vo(+) – Vo(–)] – [SENSE(+) – SENSE(–)] ≤ 10% × Vout
This limit includes any increase in voltage due to
remote sense compensation and output voltage set
point adjustment (trim).
Vi(+) Vo(+)
Sense(+)
The module will try to restart after shutdown. If the
over-temperature condition still exists during restart, the
module will shut down again. This restart trial will
continue until the temperature is within specification.
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the
module on during a logic low and off during a logic high.
Positive logic turns the modules on during a logic high
and off during a logic low.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
For negative logic if the remote on/off feature is not
used, please short the on/off pin to Vi(-). For positive
logic if the remote on/off feature is not used, please
leave the on/off pin to floating.
Vo(-)
Figure 15: Remote on/off implementation
The over-temperature protection consists of circuitry
that provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold
the module will shut down.
Remote On/Off
Vo(+)
Sense(-)
Contact
Resistance
Vi(-)
Vo(-)
Contact and Distribution
Losses
Figure 16: Effective circuit configuration for remote sense
operation
If the remote sense feature is not used to regulate the
output at the point of load, please connect SENSE(+) to
Vo(+) and SENSE(–) to Vo(–) at the module.
The output voltage can be increased by both the
remote sense and the trim; however, the maximum
increase is the larger of either the remote sense or the
trim, not the sum of both.
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum
output power does not exceed the maximum rated
power.
H24SN28012_07272006
9
FEATURES DESCRIPTIONS (CON.)
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
the modules may be connected with an external
resistor between the TRIM pin and either the
SENSE(+) or SENSE(-). The TRIM pin should be left
open if this feature is not used.
Figure 18: Circuit configuration for trim-up (increase output
voltage)
Figure 17: Circuit configuration for trim-down (decrease
output voltage)
If the external resistor is connected between the TRIM
and SENSE (-) pins, the output voltage set point
decreases (Fig. 17). The external resistor value
required to obtain a percentage of output voltage
change △% is defined as:
Rtrim down=
⎛ 100 − 2⎞ ΚΩ
⎜
⎝ ∆% ⎠
Ex. When Trim-down -60%(28.0V×0.6=16.8V)
Vo := 28.0 V
∆ := 40
100
∆
− 2 = 0.5 K Ω
If the external resistor is connected between the TRIM
and SENSE (+) the output voltage set point increases
(Fig. 18). The external resistor value required to obtain
a percentage output voltage change △% is defined
as:
Rtrim up= ⎡⎢
⎣
Vo⋅ ( 100 + ∆%)
1.225⋅ ∆%
−
100 + 2∆%⎤
∆%
⎥ ΚΩ
⎦
Ex. When Trim-up +10%(28.0V×1.1=30.8V)
Vo := 28.0 V
Vo ⋅ ( 100 + ∆ )
1.225 ⋅ ∆
∆ := 10
−
100 + 2 ⋅ ∆
∆
= 239.429 KΩ
The output voltage can be increased by both the remote
sense and the trim, however the maximum increase is
the larger of either the remote sense or the trim, not the
sum of both.
When using remote sense and trim, the output voltage
of the module is usually increased, which increases the
power output of the module with the same output
current.
Care should be taken to ensure that the maximum
output power of the module remains at or below the
maximum rated power.
H24SN28012_07272006
10
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Derating
Heat can be removed by increasing airflow over the module.
The module’s maximum case temperature is 115 ℃ . To
enhance system reliability, the power module should always
be operated below the maximum operating temperature. If
the temperature exceeds the maximum module
temperature, reliability of the unit may be affected.
THERMAL CURVES
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
PWB
FACING PWB
MODULE
Figure 20: Temperature measurement location
The allowed maximum hot spot temperature is defined at 115℃
400
H24SN28012NR A (Standard) Output Power vs. Hot Spot Temperature
(Either Orientation)
Output Power (W)
350
300
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
250
200
50.8 (2.0”)
150
AIR FLOW
100
50
12.7 (0.5”)
0
25
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 19: Wind Tunnel Test Setup
35
45
55
65
75
85
95
105
Hot Spot Temperature(℃)
Figure 21: Output power vs. hot spot temperature (Either
Orientation)
H24SN28012_07272006
11
MECHANICAL DRAWING
Pin No.
1
2
3
4
5
6
7
8
9
Name
Function
-Vin
SYNC IN
ON/OFF
+Vin
+Vout
+SENSE
TRIM
-SENSE
-Vout
Negative input voltage
Frequency Synchronization
Remote ON/OFF
Positive input voltage
Positive output voltage
Positive remote sense
Output voltage trim
Negative remote sense
Negative output voltage
Pin Specification:
Pins 1-4, 6-8
Pins 5 & 9
1.00mm (0.040”) diameter
2.00mm (0.079”) diameter
All pins are copper with Tin plating.
H24SN28012_07272006
12
PART NUMBERING SYSTEM
H
Form
Factor
24
S
280
12
N
R
Output
Voltage
Output
Current
ON/OFF
Logic
Pin
Length
N- 350W
120- 12V
12- 12.5A
N- Negative
R- 0.170”
series
280- 28V
29- 29A
P- Positive
N- 0.145”
N
Input Number of Product
Voltage Outputs
Series
H- Half
24V
S- Single
Brick
F
A
Option Code
F- RoHS 6/6
(Lead Free)
K- 0.110”
A - Standard
Functions
B- no thread
heatsink mounting
hole
MODEL LIST
MODEL NAME
H24SN28012NRFA
INPUT
18V~36V
OUTPUT
24A
28V
EFF @ 100% LOAD
12.5A
90.5%
Default remote on/off logic is negative and pin length is 0.170”
For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107 ext 6220
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon
request from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted
by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications
at any time, without notice.
H24SN28012_07272006
13
Similar pages