B-XT Series 1W, FIXED INPUT, ISOLATED SINGLE OUTPUT SMD DC-DC CONVERTER SELECTION GUIDE Input Output Isolation Efficiency MTTF1 Order code Voltage(VDC) Current (mA) Voltage Current Nominal Rated Load (VDC) (mA) Capacitance (%.Typ.) FEATURES pF KHrs B0303XT 3.3 410 3.3 303 81 29 5348 Footprint over pins 1.37cm2 B0305XT 3.3 390 5 200 83 30 3847 ◆ Short Circuit Protection(automatic recovery) B0309XT 3.3 400 9 111 74 34 3134 I/O isolation voltage 1000VDC B0312XT 3.3 400 12 83 76 40 3473 ◆ B0315XT 3.3 400 15 66 81 42 2473 B0503XT 5 270 3.3 303 85 31 5515 5 294 5 200 83 33 6857 ◆ ◆ Operating Temperature: -40℃~﹢85℃ ◆ High efficiency up to 78% B0505XT ◆ Toroidal magnetics B0505NXT 5 260 5 200 86 42 3933 B0506XT 5 278 6 167 83 43 6677 B0509XT 5 267 9 111 85 38 5501 B0512XT 5 260 12 83 74 44 3957 5 256 15 66 78 43 2747 ◆ Small SMD package with footprint ◆ Power density 1.8W/cm3 ◆ Lead frame technology B0515XT ◆ Multi-layer ceramic capacitors B1205XT 12 124 5 200 80 50 4683 B1209XT 12 114 9 111 80 72 4008 B1212XT 12 113 12 83 85 89 3121 B1215XT 12 111 15 66 81 100 2316 ◆ Custom solutions available MODEL SELECTION ① ② ③ ④ 1. Calculated using MIL-HDBK-217FN2 with nominal input voltage at full load. All specifications typical at TA=25℃, nominal input voltage and rated output current unless otherwise specified. ⑤ B 05 05 X T ①Product Series ③Output Voltage ⑤SMD Package ②Input Voltage ④Fixed Input Input Characteristics Parameter Voltage range APPLICATIONS The B-XT series are miniature,1W DC/DC converters with high isolation in a SMD package. With a new package design these converters are qualified for the higher temperatures requested by lead-free reflow solder processes. With the small footprint, these converters are the ideal solution for board level power distribution,mainly for applications in the industrial and telecom field. For automated SMD production lines the devices can be supplied in standard tape and reel package. Conditions Min. Typ. Max. Units Continuous operation, 3.3V input 2.97 3.3 3.63 VDC Continuous operation, 5V input 4.5 5 5.5 VDC Continuous operation, 12V input 10.8 12 13.2 VDC 30 47 mA p-p Typ. Max. Units Start up time Isolation Characteristics Parameter Conditions Min. Isolation voltage Flash tested for 1 second 1000 VDC Resistance Viso= 1000VDC 10 GΩ General Characteristics Parameter Conditions Switching frequency All output types Min. Typ. Max. 110 Units kHz Absolute Maximum Ratings MICRODC R ESERVES THE COPYRIGHT http://www.microdc.cn Parameter Conditions Lead temperature 1.5mm from case for 10 seconds 300℃ Internal power dissipation 600mW Input voltage V , B03 types 5.5V Input voltage Vin, B05 types 7V Input voltage Vin, B12 types 15V Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 1 of 6 B-XT Series Output Specifications Parameter Conditions Min. Rated Power TA=-40°C to 85°C 0.1 Voltage Set Point See tolerance envelope Line regulation Typ. Max. Units 1.0 W High VIN to low VIN 1.0 1.2 %% 10% load to rated load, 0303& 0503 10 14 % 10% load to rated load, 0505& 1205 12.8 15 % 10% load to rated load, 0506 9.2 10 % 10% load to rated load, 0509 & 1209 8.3 9.0 % 10% load to rated load, 0512& 1212 6.8 7.5 % 10% load to rated load, 0515& 1215 6.3 7.0 % BW=DC to 20MHz, 3.3V output types, 0305 & 0505 40 60 mV p-p 1 Load regulation BW=DC to 20MHz, 3.3V output types,0505 & 1205 62 85 mV p-p BW=DC to 20MHz, 0506 103 170 mV p-p BW=DC to 20MHz, 0509& 1209 49 75 mV p-p BW=DC to 20MHz, 0512& 1212 39 65 mV p-p BW=DC to 20MHz, 0515& 1215 38 76 mV p-p Typ. Ripple&Noise Note:1、12V input types have typically 3% less load regulation change. Temperature Characteristics Parameter Conditions Min. Max. Units Specification All output types -40 85 ℃ -55 125 ℃ Storage Case temperature rise above ambient Cooling 0305, 0309, 0315 25 ℃ 0303, 0312, 0503, 0505, 0509, 0512C, 0515 30 ℃ 0505, 1205 43 ℃ 1209, 1212, 1215 40 ℃ Free air convection Technical notes ISOLATION VOLTAGE ‘Hi Pot Test’、“Flash Tested’、”Withstand Voltage“、‘Proof Voltage”、“Dielectric Withstand Voltage'&'Isolation Test Voltage”are all terms that relate to the same thing, a test voltage, applied for a speci fied time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Professional Power Module B-XT series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second. A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?” For a part holding no specific agency approvals, such as the B-XT series, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The B-XT series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. Temperature derating graph http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 2 of 6 B-XT Series Application Notes Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will start into a capacitance of 47μF with an increased start time, however, the maximum recommended output capacitance is 10μF. Start-up time Start-up time μs μs B0303XT 437 B0506XT 7200 B0305XT 1359 B0509XT 3146 B0309XT 3435 B0512XT 4960 B0312XT 6590 B0515XT 7740 B0315XT 7625 B1205XT 895 B0503XT 533 B1209XT 2150 B0505XT 1368 B1212XT 3640 B0505NXT 721 B1215XT 7180 Ripple & Noise Characterization Method Ripple and noise measurements are performed with the following test configuration. C1 1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter C2 10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less than 100mΩ at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450Ω resistor, carbon fi lm, ±1% tolerance R2 50Ω BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic http://www.microdc.cn http://www.microdc.cn Technical enquiries-Email:[email protected] Tel:0086-20-86000646 Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 page 1/3 Page 3 of 6 B-XT Series Application Notes Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. Inductor Capacitor L,μH SMD Through Hole C,μF B0303XT 10 82103C 11R103C 4.7 B0305XT 47 82473C 11R103C 4.7 B0309XT 22 82223C 11R223C 2.2 B0312XT 10 82103C 11R103C 1 B0315XT 47 82473C 11R473C 1 B0503XT 10 82103C 11R103C 4.7 B0505XT 47 82473C 11R473C 4.7 B0505NXT 47 82473C 11R473C 4.7 B0506XT 10 82103C 11R103C 4.7 B0509XT 22 82223C 11R223C 2.2 B0512XT 47 82473C 11R473C 1 B0515XT 47 82473C 11R473C 1 B1205XT 47 82473C 11R473C 4.7 B1209XT 22 82223C 11R223C 2.2 B1212XT 47 82473C 11R473C 1 B1215XT 47 82473C 11R473C 1 Tolerance Envelopes The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 4 of 6 B-XT Series OUTLINE DIMENSIONS & FOOTPRINT DETAILS SOLDER PAD DIMENSION MECHANICAL DIMENSIONS Note: Unit:mm[inch] Pin section tolerances:±0.10mm[±0.004inch] General tolerances:±0.25mm[±0.010inch] Weight: 1.21g FOOTPRINT DETAILS Pin Single 1 -Vin 3 +Vin 5 NA 7 -Vout 8 +Vout 10 NA 12 NA 14 NA Dimensions in [mm], () = Inch Pin pitch tolerances: ±0.13 (±0.005) Other tolerances: ±0.25 (±0.01) TUBE OUTLINE DIMENSIONS NA - Not available for electrical connection. Unless otherwise stated all dimensions in mm±0.5 (inches ±0.02). Tube length : 475±2.0 (18.70±0.07). Tube Quantity :35 Specifcations can be changed any time without notice. No parallel connection or plug and play. Note: 1. The load shouldn't be less than 10%, otherwise ripple will increase dramatically. 2. Operation under 10% load will not damage the converter; However, they may not meet all specification listed. 3. All specifications measured at Ta=25°C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 4. In this datasheet, all the test methods of indications are based on corporate standards. 5. Only typical models listed, other models may be different, please contact our technical person for more details. http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 5 of 6 B-XT Series Tape & Reel Specifications Reel Packaging Details Product Orientation Pin 1, located nearest to carrier drive sprocket. Reel Quantity : 500 Reel Outline Dimensions Tape Outline Dimensions RoHS COMPLIANT INFORMATION Microdc Professional Power Module,Inc. This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C Tel:0086-20-86000646 E-mail:[email protected] for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Website:http://www.microdc.cn Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are Microdc Professional Power module,Inc.makes no representation that backward compatible with Sn/Pb soldering systems. the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or REACH COMPLIANT INFORMATION future patent rights. Specifications are subject to change without notice. This series has proven that this product does not contain harmful chemicals, it also has harmful chemical ©2010 substances through the registration, inspection and approval. Microdc Professional Power Module, Inc. Guangzhou http://www.microdc.cn Technical Enquiries-Email:[email protected] Tel:0086-20-86000646 Page 6 of 6