Rohm LBP-602MK2 Double digits led numeric display Datasheet

Double Digits LED Numeric Display
LBP-602 A / K2 Series
LBP-602 A / K2 series are the numberical display units
featuring ROHM’s in-house 4-element(AlGaInP)
high-brightness LED dies.Their luminous intensity is top
class in the industry while degradation is considerably slow,
which helps to keep illumination vividness almost unchanged
and the image of sets high over a long period of time.
Dimensions (Unit : mm)
25.0±0.1
12.5
0.25
Features
1) 14.3mm for letter height, two-lines LED numerical displays.
2) About 10 times more luminous intensity than the conventional
products by use of 4-element LED dies. (in case of orange color)
3) The same luminous intensity as the conventional products
at their 1/10 of current, which contributes lots to energy-saving
of sets.
4)Light-leakage from segments probable with the small display
packages is very rare.
5)Both anode common type and cathode common type
are available in lineup for each color.
(15.24)
1.3
14.3
19.0±0.1
10°
2−φ1.5
3.5Min.
8.0
1.3
8.0
0.5
(2.54)
(20.32)
Tolerance are ±0.3 unless otherwise noted :
Selection guide
Emitting color
Common
Anode
Cathode
Red
Orange
Yellow
Green
LBP-602VA2
LBP-602VK2
LBP-602DA2
LBP-602DK2
LBP-602YA2
LBP-602YK2
LBP-602MA2
LBP-602MK2
Pin assignments
18 17 16 15 14 13 12 11 10
+
+
+
+
+
+
+
a1
+
+
a2
f1
b1 f2
b2
g1
g2
e1
c1 e2
c2
d1
d2
Digit 1 D.P1
Digit 2 D.P2
+
+
+
+
+
+
+
+
+
Pin No. 1
2
3
4
5
6
7
8
9
Inner circuit (anode common)
a1 b1 c1 d1 e1 f1 g1 D.P1
16 15 3 2 1 18 17 4
Function
Pin No.
Function
1
2
3
4
5
6
7
8
9
Segment "e1"
Segment "d1"
Segment "c1"
D.P1
Segment "e2"
Segment "d2"
Segment "g2"
Segment "c2"
D.P2
10
11
12
13
14
15
16
17
18
Segment "b2"
Segment "a2"
Segment "f2"
Digit 2 Common
Digit 1 Common
Segment "b1"
Segment "a1"
Segment "g1"
Segment "f1"
(cathode common)
a2 b2 c2 d2 e2 f2 g2 D.P2
11 10 8 6 5 12 7 9
14
Dig.1
Pin No.
a1 b1 c1 d1 e1 f1 g1 D.P1
16 15 3 2 1 18 17 4
13
COM
Dig.2
www.rohm.com
c 2010 ROHM Co., Ltd. All rights reserved.
○
a2 b2 c2 d2 e2 f2 g2 D.P2
11 10 8 6 5 12 7 9
14
COM
Dig.1
1/3
13
COM
Dig.2
COM
2010.12 - Rev.A
LBP-602 A / K2 Series
Data Sheet
Absolute maximum ratings (Ta=25C)
Red
Symbol
Parameter
PD
PD / seg
IF
IFP
VR
Topr
Tstg
Power dissipation
Power dissipation
Forward current
Peak forward current
Reverse voltage
Operating temperature
Storage temperature
Orange
Green
Yellow
Unit
LBP-602VA2 / VK2 LBP-602DA2 /DK2 LB-602YA2 / YK2 LBP-602MA2 / MK2
896
896
896
896
56
56
56
56
20
20
20
20
60 ∗
60 ∗
60 ∗
60 ∗
5
5
5
5
−25 to +75
−30 to +85
mW
mW
mA
mA
V
˚C
˚C
∗ Pulse width 1ms Duty 1 / 5
Electrical characteristics (Ta=25C)
Symbol Conditions
Parameter
Forward voltage
Reverse current
Peak wavelength
Spectral line half width
IF=10mA
VR=3V
IF=10mA
IF=10mA
VF
IR
λP
Δλ
Red
Max.
2.8
100
−
−
Typ.
1.9
−
650
20
Orange
Typ.
1.9
−
605 ∗
20 ∗
Max.
2.8
100
−
−
Yellow
Typ.
1.9
−
590
20
Max.
2.8
100
−
−
Green
Typ.
1.9
−
572
20
Max.
2.8
100
−
−
Unit
V
μA
nm
nm
The products are not radiations resistant.
Luminous intensity
Color
λP (nm)
Red
650
Orange
605
Yellow
590
Green
572
Type
LBP-602VA2
LBP-602VK2
LBP-602DA2
LBP-602DK2
LBP-602YA2
LBP-602YK2
LBP-602MA2
LBP-602MK2
Min.
Typ.
Unit
14
36
mcd
56
250
mcd
90
450
mcd
36
100
mcd
A condition of measurement is IF=10mA.
www.rohm.com
c 2010 ROHM Co., Ltd. All rights reserved.
○
2/3
2010.12 - Rev.A
LBP-602 A / K2 Series
Data Sheet
Electrical and optical characteristic curve
100
10
Relative Luminous Intensity
10
1
0.1
1
0.1
0.01
2.4
1
Fig.1 Forward Current - Forward Voltage
1.2
1
0.8
0.6
0.4
20
40
60
80
Case Temperature : Tc(℃)
Fig.3 Relative Luminous Intensity Case Temperature(℃)
10
Ta=25
℃
50kHz
IF=10mA
1.4
0
100
Fig.2 Relative Luminous Intensity Forward Current
Ratio of Maximum Tolerance Peak Current IF PEAK MAX.
IF MAX.
to Maximum Tolerance DC Cerrent
Relative Luminous Intensity
1.6
-20
10
Forward Current(mA)
Forward Voltage : VF(V)
100Hz
2.2
200Hz
2
1kHz
1.8
500Hz
1.6
5kHz
1.4
2kHz
1.2
10kHz
1
20kHz
Forward Current : IF(mA)
Ta=25℃
1
1
10
100
1000
10000
Pulse Duration : Tw (μs)
Fig.4 Ratio of Maximum Tolerable Peak CurrentPulse Duration
120
Forward Current(%)
100
80
60
40
20
0
-25
-15
-5
5
15
25
35
45
55
65
75
85
Ambient Temperature(℃)
Fig.5 Derating
www.rohm.com
c 2010 ROHM Co., Ltd. All rights reserved.
○
3/3
2010.12 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A
Similar pages