Constant voltage LED Drivers For indoor use LMB-6V Series, 6 Watt FEATURES: Constant voltage output Input voltage range 200-240Vac Short circuit, overload, and over temperature protections Designed to worldwide safety standards for lighting Cooling by free air convection 3 years warranty Model LMB6-V12 LMB6-V24 Input voltage (Vac) 200-240 Output voltage (Vdc) Output current (mA) Output power (W) Min. Max. 12 0 500 6 24 0 250 6 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin --- 180 -- 264 Vac Input frequency Fline --- 47 -- 63 Hz Input current Iin Full load, Vin =230Vac -- -- 0.1 A Inrush current Iinrush Cold start, Vin =230Vac -- -- 40 A Power factor PF 70%~100% load, Vin =220Vac -- 0.5 -- PF η Full voltage, full load 79 80 80 % LMB6-V12 -- 500 -- mA LMB6-V24 -- 250 -- mA LMB6-V12 11.4 12 12.6 V LMB6-V24 22.8 24 25.2 V Vin from 200Vac to 240Vac -- -- 1 % Efficiency Output Output current Iout Output voltage Vout Line regulation Iout-line www.pairuigroup.com Page: 1 / 3 Date: 01/07/2014 Constant voltage LED Drivers For indoor use LMB-6V Series, 6 Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Load regulation Iout-load Vout from min. To max. -- -- 5 % Turn-on delay time Ton_delay Cold start, power on -- -- 2 S -- --- -- 300 400 mV Ripple Protection Overload Hiccup mode, it will recover automatically after fault conditions remove Short circuit Hiccup mode, it will recover automatically after fault conditions remove Over temperature Protection type: shut down O/P voltage recovers automatically after temperature goes down Environment Storage Ambient operating temperature Maximum case temperature Operating relative humidity MTBF Tstorage Humidity: 5% RH to 95% RH -40 -- +80 ℃ Ta Startup at rated voltage -20 -- +45 ℃ Tc Hot-spot on case -- -- +80 ℃ Ha Non condensing 10 -- 95 % -- -- 30 kHrs TMTBF Full load, 220Vac input, ℃ 25 ambient temperature Dimension(LxWxH) 94x44x19.4mm Safety / EMC Safety standards IEC61347-1 EMI IEC55015 EMS IMMUNITY IEC61547 THD IEC61000-3-2 IEC61347-2-13 ℃ and Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 Vin = 200Vac to 240Vac. www.pairuigroup.com Page: 2 / 3 Date: 01/07/2014 Constant voltage LED Drivers For indoor use LMB-6V Series, 6 Watt MECHANICAL Unit: mm www.pairuigroup.com Page: 3 / 3 Date: 01/07/2014