HGN-375 IEC 60320 INLET SOCKET WITH SWITCH, SINGLE AND DOUBLE FUSE HOLDER, FLANGE MOUNT MECHANICAL DIMENSIONS (Unit: mm) 52.0 67.0 Use only with a 250V Fuse Employer uniqement avec un fusible de 250V O 33.5 40.0+- 0.2 0.8 TYP. FEATURES The HGN-375 protects electronic equipment from common and differential mode line interference in the range of 10KHz up to 30MHz. This “combi-unit” is equipped with IEC connector, fuse holder for one or two 5 x 20 mm fuses, 2 pole on/off switch and fully enclosed metal housing. 60.5 These filters are also available for Medical equipment with low leakage current. HGN-375 series filters are high performance filters and have been designed to bring various medical equipments into compliance with EN55011 and FCC Part 15J, Class B conducted emissions limits. 28.5 6.30 TYP. APPLICATIONS 57.5 Computer & networking equipment, Measuring & control equipment, Data processing equipment, laboratory instruments, Switching power supplies, other electronic equipment. TECHNICAL DATA • Rated Voltage: 125/250VAC • Rated Current: 1A, 2A, 4A, 6A, 10A • Power Line Frequency: 50/60Hz • Max. Leakage Current each Line to Ground: @ 250VAC 50Hz: 0.5mA, max @ 250VAC 50Hz: 2µA*, max • Hipot Rating (one minute) Line to Ground: 2250VDC Line to Line: 1450VDC • Temperature Range: -25C to +85C 45.0 6.0 40.0+- 0.2 29.5 4x R0.5 61.5 2x M3 * Medical application Specifications subject to change without notice. Dimensions (mm). See Appendix A for recommended power cord. See PDI full line catalog for detailed specifications on power cords. 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com 79 HGN-375 Series Example & Ordering Code HGN-375 - 1 CURRENT RATING (A): = = = = = SCHEMATIC: M - F2 1 2 4 6 10 STANDARD TYPE = WITHOUT C(Y); C(X) ONLY =M FUSE OPTION: BLANK 1 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT = F1 2 FUSE (5X20MM), 6.3/0.25 QUICK CONNECT = F2 Attenuation Tables & Schematics Non-Medical Applications Insertion loss in dB (50 Ohm circuit) 40 37 22 19 17 51 41 30 26 30 46 35 42 37 32 32 29 29 51 79 31 29 30 29 80 21 21 23 25 51 3 10 7 16 60 75 5 12 10 11 60 73 8 10 16 19 40 67 5 8 15 16 30 51 2 9 13 17 26 33 89 82 84 79 53 80 82 80 80 60 39 39 40 50 40 E P FUSE L(mH) FUSE L(mH) 2200pF E' 2200pF LOAD 38 35 20 17 15 N' 0.01 F 33 30 17 13 6 0.033 F 24 16 10 8 5 L(mH) FUSE 0.068 F 10.3mA 4.6mA 2.5mA 1.2mA 0.8mA LINE 1A 2A 4A 6A 10A N 1M Current L Comm. Mode(L-G) MHz Diff. mode(L-L) MHz Rating Value .01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30 P' Medical Applications 80 32 30 18 13 13 38 35 20 17 16 41 36 22 19 19 51 41 30 26 25 48 36 42 37 32 32 29 29 28 29 31 30 30 29 29 22 21 22 24 24 2 10 8 15 60 75 5 12 10 10 60 73 8 10 17 19 40 67 5 7 15 17 30 51 5 5 15 18 30 51 84 82 84 80 79 80 83 80 80 80 39 36 33 41 51 E P FUSE L(mH) E' LOAD 23 18 10 8 8 N' 0.01 F 10.3mA 4.6mA 2.5mA 1.2mA 0.8mA N 0.033 F 1A 2A 3A 4A 6A Comm. Mode(L-G) MHz Diff. mode(L-L) MHz .01 .05 .1 .15 .5 1 5 10 30 .01 .05 .1 .15 .5 1 5 10 30 0.068 F L Value LINE Current Rating 1M Insertion loss in dB (50 Ohm circuit) P' 145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076 e-mail: [email protected] • www.powerdynamics.com