Astrodyne LPP100-5 100w single output with pfc function Datasheet

LPP100
100W S i n g l e Ou t put w it h P FC Func t i on
series
Universal AC input
Protections:Short circuit/Over load/Over voltage
Built-in active PFC function
Cooling by free air convection
Fixed switching frequency at PFC:67KHz PWM:134KHz
Model Number
Output Volts
Output Amps
3.3 Volts(DC)
5 Volts(DC)
7.5 Volts(DC)
12 Volts(DC)
13.5 Volts(DC)
15 Volts(DC)
24 Volts(DC)
27 Volts(DC)
48 Volts(DC)
20 Amps
20 Amps
13.5 Amps
8.5 Amps
7.5 Amps
6.7 Amps
4.2 Amps
3.8 Amps
2.1 Amps
Ripple & Noise
Min Load
DC Volt Adjust Load Reg Efficiency
SINGLE OUTPUT
LPP100-3.3
LPP100-5
LPP100-7.5
LPP100-12
LPP100-13.5
LPP100-15
LPP100-24
LPP100-27
LPP100-48
WWW.ASTRODYNETDI.COM
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
100mV pk-pk
150mV pk-pk
250mV pk-pk
0~20Amps
0~20Amps
0~13.3Amps
0~8.5Amps
0~7.5Amps
0~6.7Amps
0~4.2Amps
0~3.8Amps
0~2.1Amps
3.14~3.63Volt(DC)
4.75~5.5Volt(DC)
7.13~8.25Volt(DC)
11.4~13.2Volt(DC
12.8~14.9Volt(DC)
14.3~16.5Volt(DC)
22.8~26.4Volt(DC)
25.7~29.7Volt(DC)
45.6~52.8Volt(DC)
±1.0%
±1.0%
±1.0%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
69%
75%
76%
79%
79%
80%
83%
83%
83%
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
LPP100
100W S i n g l e Ou t put w it h P FC Func t i on
INPUT SPECIFICATIONS
Input Voltage Range (Note 3)
Frequency Range
Inrush Current, typ: (cold start)
Input Current
Leakage current
Min Load
Power Factor @ FL
90 ~ 264VAC 120~370 Volts(DC)
47-63 Hz
30Amps / 230VAC
1.7 Amps. @ 115VAC
0.75 Amps. @ 230VAC
< 2mAmps / 240VAC
See Selection Chart
PF> 0.95 / 230VAC
0.98 / 115VAC
OUTPUT SPECIFICATIONS
Voltage and Current
Line Regulation
Load Regulation
Voltage Tolerance (Note 2)
Ripple/Noise (Note 1)
Hold Up Time @ FL
Setup, Rise Time @ FL
Over Voltage Protection
Over Current Protection
DC Volt Adjust
See Selection Chart
±0.5%
See Selection Chart
±2.0%: 3.3~15Volts(DC)
±1.0%: 24~48Volts(DC)
See Selection Chart
28mS /230VAC; 28mS/115VAC
600ms, 30mS/ 230VAC
1200ms, 30mS/115VAC
3.8 ~ 4.45Volt(DC): 3.3Volts(DC)
5.75 ~ 6.75Volt(DC): 5Volts(DC)
8.6 ~ 10.1Volt(DC): 7.5Volts(DC)
13.8 ~ 16.2Volt(DC): 12Volts(DC)
15.5 ~ 18.2Volt(DC): 13.5Volts(DC)
17.25~ 20.25Volt(DC): 15Volts(DC)
27.6 ~ 32.4Volt(DC): 24Volts(DC)
31 ~ 36.45Volt(DC): 27Volts(DC)
55.2 ~ 64.8Volt(DC): 48Volts(DC)
Shut down o/p voltage,re-power
105 ~ 150% rated output power
Constant current limiting,auto recover
See Selection Chart
Insulation Resistance
EMI
Harmonic Current
Efficiency
Isolation
EMS
series
≥ 100MΩ / 500Volts(DC)
Compliance to EN55022B (CISPR22B)
Compliance to EN61000-3-2,-3
See Selection Chart
3000VAC Input - Output
1500VAC Input - Ground
500VAC Output - Ground
Compliance to
EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, light Industry Level, Criteria A
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Storage Temperature
Relative Humidity
Temperature Coefficient
MTBF
Vibration
-10°C to +60°C (See Derate Curve)
-20°C to +85°C, 10~95% RH
20~90% RH non cond
±0.05% / °C (0-50°C) 224.3KHrs min,MIL-HDBK-217F(25°C)
10~500Hz, 2G10min./1cycle, period for 60min. each along X, Y, Z axes
PHYSICAL SPECIFICATIONS
Size
Millimeters
222 x 62 x 32
Inches
8.74” x 2.44 ” x 1.26 ”
Weight
17.99 oz (510g)
NOTE
1. Ripple & noise are measured at 20MHz of bandwidth by using a 12”
twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Derating may be needed under low input voltages. Please check the
derating curve for more details.
GENERAL SPECIFICATIONS
Safety
UL60950-1, TUV EN60950-1 Approved
All specifications are typical at nominal input, full load, and 25°C unless otherwise noted
WWW.ASTRODYNETDI.COM
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
100W S i n g l e Ou t put w it h P FC Func t i on
WWW.ASTRODYNETDI.COM
LPP100
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
100W S i n g l e Ou t put w it h P FC Func t i on
WWW.ASTRODYNETDI.COM
LPP100
series
ASTRODYNE USA: 1-800-823-8082
ASTRODYNE PACIFIC: 886-2-26983458
Similar pages