SL Power LE200S-CD 200w single output led driver sery Datasheet

LE200S-CD
200W Single Output
LED Driver Series
Features
High Efficiency (up to 93%)
Wide Range Universal Input 90-305 VAC
Active Power Factor Correction (0.99 typical)
Constant Current Output
Dimming Function
Lightning Protection
Waterproof (IP67)
Overcurrent, Overvoltage, Overtemperature
Protection
Meets UL8750 & EN61347 Safety
3 Year Warranty
Description
The LE200S-CD Series operate from a 90 ~ 305Vac input range. These units will provide up to a 0.7A of
output current and a maximum output voltage of 285Vdc for 200 W maximum output power. They are designed
to be highly efficient and highly reliable. The standard features include dimming control, lightning protection,
over voltage protection, short circuit protection, and over temperature protection.
Model Selection
Model
Number
Output
Current
Output
Voltage
LE200S70CD
665mA-735mA
143V – 285V
Notes:
Efficiency*
110Vac
220Vac
90%-91%
92%-93%
Ripple &
Noise**
Regulation
Line
Load
8.6V pk-pk max.
±1%
±3%
Overvoltage
Trip Level
342V – 428V
1. Efficiency measured at full load, at input voltage noted.
2. Measured at 20MHz bandwidth, with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR electrolytic
capacitors.
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
www.slpower.com
Turn On Time
90-305Vac, 47-63Hz, 1∅
100Vac: 2.4A, 220Vac: 1.2A
230Vac, cold start: will not exceed 65A
Overload
Protection
Dimming
Function
1.0 seconds, max.
Constant Current
1-10Vdc source or External Resistor can be
used for dimming control. See below.
XA, 250VAC fuses provided on all models
LE200S-CD REV 2.0,11-FEB-13
1
LE200S-CD
200W Single Output
LED Driver Series
General Specifications (continued)
Earth Leakage
Current
Efficiency
Output Power
Short Circuit
Protection
<0.75mA@277Vac, 50Hz
See Models chart.
200W continuous
Provided - no damage to unit, self-recovery.
Overvoltage
Protection
Latch mode. AC input will need to be reset to
return to normal operation after an OVP
condition. See chart for trip range.
Overtemperature
Protection
Latch mode. AC input will need to be reset to
return to normal operation after an OTP
condition. Trip Temperature = 110°C typical.
Ripple and Noise
See chart
Operating
Temperature
Output Voltage
See chart
Relative Humidity
10% to 100% operating
5% to 100%, non-operating
+/- 3%. See chart
Safety Standards
UL8750, UL935, UL1012, CSA-C22.2 No. 107.1,
EN61347-1, EN61347-2-13
Total Regulation
Dimensions
Weight
MTBF
330,000 hours (450mA model, 110Vac input,
80% load, 25°C ambient, per MIL-HDBK-217F).
Lifetime
90,000 hours (1400mA model, at 110Vac input,
80% load, 45°C ambient temperature).
W: 3.13” x L: 9.37” x H: 1.81”
1500g
Operating:
-35°C to +70°C
Non-operating: -40°C to +85°C
EMI/EMC Compliance
Emissions
EN55015, Radiated & Conducted with 6db of margin
EMI for Lighting Equipment
EN61547
Static Discharge Immunity
EN61000-4-2, 4kV Contact Discharge, 8kV air discharge
Radiated RF Immunity
EN61000-4-3
EFT/Burst Immunity
EN61000-4-4
Line Surge Immunity
EN61000-4-5, 4kV line-line, 6kV line-earth
Conducted RF Immunity
EN61000-4-6
Power Frequency Magnetic Field Immunity
EN61000-4-8
Voltage Dip Immunity
EN61000-4-11
Line Harmonic Emissions
EN61000-3-2
Flicker Test
EN61000-3-3
www.slpower.com
LE200S-CD REV 2.0,11-FEB-13
2
LE200S-CD
200W Single Output
LED Driver Series
Derating Curves
Mechanical Drawing
www.slpower.com
LE200S-CD REV 2.0,11-FEB-13
3
LE200S-CD
200W Single Output
LED Driver Series
Dimming Control
The dimmer control may be operated from either a potentiometer or from an input signal of 1 – 10 Vdc. Two recommended implementations are
provided below.
Parameters:
Parameter
Min.
Typ.
Max.
Absolute Max. Voltage on the 1-10V input
-2V
-
12V
Sink Current on the 1-10V input pin
0mA
-
1mA
Notes
LE200SXXXCD
Dimming Configuration using External Voltage
LE150SXXXCD
Dimming Configuration using External Resistance
Dimming Control Notes:
1. Io is actual output current and Ir is rated current without dimming control.
2. For the driver to operate properly, the load voltage must be maintained above the minimum voltage threshold (approx. 50% of the max.
output voltage for any given model).
3. If the output voltage is maintained above 50% of the maximum output voltage, the dimming control may be
operated over the entire 1-10V range with output current varying from 100% down to practically 10%.
4. The dimming signal is allowed to be less than 1V, however, when it for 0-1V, the output current is 10%Io.
5. Do not connect the GND of dimming to the output; otherwise, the LED driver can not work normally.
Data Sheet © 2012 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
LE200S-CD REV 2.0,11-FEB-13