Series AM30EW-NZ 30 Watt | DC-DC Converter Picture coming soon FEATURES: • • • • • • • • • • Efficiency up to 90% Ultra-wide 4:1 Input range No-load consumption ≤0.14W Operating Temperature: -40oC to +75oC Input under voltage lockout On/Off Remote Control Over Voltage Protection I/Output Isolation 1500VDC Over Current protection Continuous Short Circuit protection Models Single output Model Input Voltage (V) Max Input current Full/No load (mA) Output Voltage (V) Output Current max (A) Isolation (VDC) Max Capacitive Load(uF) Efficiency (%) 3.3 5 9 12 15 24 3.3 5 12 15 24 6 6 3.33 2.5 2 1.25 6 6 2.5 2 1.25 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 10000 10000 4700 2700 1680 680 10000 10000 2700 1680 680 85 88 88 90 90 90 87 88 89 89 89 AM30EW-2403S-NZ 9-36* 993/80 AM30EW-2405S-NZ 9-36* 1453/80 AM30EW-2409S-NZ 9-36* 1420/9 AM30EW-2412S-NZ 9-36* 1420/9 AM30EW-2415S-NZ 9-36* 1420/9 AM30EW-2424S-NZ 9-36* 1420/9 AM30EW-4803S-NZ 18-75 485/23 AM30EW-4805S-NZ 18-75 726/25 AM30EW-4812S-NZ 18-75 718/8 AM30EW-4815S-NZ 18-75 718/8 AM30EW-4824S-NZ 18-75 718/8 *At Input range 9-18VDC output power will be rated at 80%. Add suffix “-K” for optional heat sink. NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Nominal Typical 24 48 9-36 18-75 π(Pi) Network 10 Filter Startup time Absolute Maximum Rating (1sec max) 24 48 On/Off control Input under voltage lockout Input reflected current 24 48 Maximum Units VDC ms -0.7-50 -0.7-100 ON – open or 3.5-12VDC ; OFF – short to –Vin or 0-1.2VDC, Idle current: 5 - 8mA 5.5-6.5 14-15.5 40 VDC VDC mA Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R13 Conditions Typical 60 sec, 1mA 500VDC Isolation I/O 100KHz/0.1V 1500 >1000 2000 Tel: +1 514 620 2722 1 of 5 Maximum Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-NZ 30 Watt | DC-DC Converter Output Specifications Parameters Conditions Voltage accuracy Over voltage protection Over current protection Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Voltage adjustment range Transient recovery time Typical ±1 Zener Diode Clamp 110 110 Continuous, hiccup Auto-Recovery Full load, LL-HL ±0.2 0% to 100% load ±0.5 20MHz Bandwidth, 5% to 100% load Transient recovery deviation 25% load step change 25% load step change: 3.3, 5, ±5Vout 25% load step change: others ±5 ±3 Maximum Units ±3 160 190 % % % of Io ±0.5 ±1 ±0.03 100 ±10 500 ±8 ±5 % of Vin % o %/ C mV p-p % µS % General Specifications Parameters Switching frequency Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Maximum soldering temperature Conditions Typical 100% load See derating curve 300 Maximum Units 100 KHz o C o C o C -40 to +75 -55 to +105 Free air convection 95 Aluminum Alloy 26 without heat sink/ 34 with heat sink Without heatsink 2 x 1 x 0.47 inches 50.8 x 25.4 x 11.8 mm With heatsink 2 x 1 x 0.64 inches 50.8 x 25.4 x 16.3 mm o >1,000,000 hours (MIL-HDBK -217F, Ground Benign, t=+25 C) 1.5mm from case for 10 sec 300 % RH g o C Environment Specification Test Vibration Parameters Test mode Acceleration Conditions 10-55Hz 10g, 30min, every axis tested Safety Specifications Parameters Standards www.aimtec.com F 051e R13 IEC/EN/UL 60950-1 pending Meet EN 55022, Class B, with external filter & EN 55024: 2010 IEC 61000-4-2, Contact ±4KV, Criteria B IEC 61000-4-3, 10V/m, Criteria A IEC 61000-4-4, ±2KV, Criteria B, with external filter IEC 61000-4-5, ±2KV, Criteria B, with external filter IEC 61000-4-6, 3Vrms, Criteria A IEC 61000-4-29, 0-70%, Criteria B Tel: +1 514 620 2722 2 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-NZ 4 1 2 5 Bottom View 3 6 2.54 (0.10) 4.10 (0.16) 11.80 (0.47) 10.16 (0.40) (2.00) 10.16 (0.40) Dimensions 50.80 2.54 (0.10) Single +Vin -Vin On/Off Control +Vout -Vout Trim 25.40 (1.00) Pin 1 2 3 4 5 6 10.16 (0.40) Pin Out Specifications 5.08 (0.20) 5.08 (0.20) 30 Watt | DC-DC Converter 2.54 (0.10) Notes: All dimensions are typical in millimeters (inches). Pin Pitch Tolerance ±0.10 (±0.004) Case Tolerance ±0.50 (±0.02) Trimming Output voltage can be externally trimmed by utilizing the methods as shown below Fixed Resistor Variable Potentiometer Leave open if not used. AM30EW-xx03S-NZ Trim down % 1 Vout (VDC) 3.27 Rt down (KΩ) 124.138 Trim up % 1 Vout (VDC) 3.33 Rt up (KΩ) -556.59 2 3.23 73.217 2 3.37 194.738 3 3.2 53.983 3 3.4 89.364 4 3.17 41.497 4 3.43 55.050 5 3.14 32.737 5 3.47 34.131 6 3.1 24.449 6 3.5 25.350 7 3.07 19.839 7 3.53 19.357 8 3.04 16.148 8 3.56 15.006 9 3 12.236 9 3.6 10.773 10 2.97 9.856 10 3.63 8.367 AM20EW-xx05S-NZ Trim down % 1 Vout (VDC) 4.95 Rt down (KΩ) 105.180 Trim up % 1 Vout (VDC) 5.05 Rt up (KΩ) 176.356 2 4.9 52.153 2 5.1 71.279 3 4.85 31.996 3 5.15 41.973 4 4.8 21.377 4 5.2 28.200 5 4.75 14.822 5 5.25 20.197 6 4.7 10.372 6 5.3 14.967 7 4.65 7.154 7 5.35 11.281 8 4.6 4.719 8 5.4 8.543 9 4.55 2.811 9 5.45 6.430 10 4.5 1.276 10 5.5 4.749 www.aimtec.com F 051e R13 Tel: +1 514 620 2722 3 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-NZ 30 Watt | DC-DC Converter AM20EW-xx09S-NZ Trim down % 1 Vout (VDC) 8.91 Rt down (KΩ) 375.532 Trim up % 1 9.09 Vout (VDC) 2 8.82 207.429 2 9.18 3 8.73 139.156 3 9.27 4 8.64 102.145 4 9.36 5 8.55 78.924 5 9.45 6 8.46 62.996 6 9.54 7 8.37 51.392 7 9.63 8 8.28 42.562 8 9.72 9 8.19 35.616 9 9.81 10 8.1 30.011 10 9.9 Rt up (KΩ) 314.531 112.638 64.147 42.357 29.974 21.989 16.412 12.296 9.134 6.628 AM20EW-xx12S-NZ Trim down % 1 Vout (VDC) 11.88 Rt down (KΩ) 496.091 Trim up % 1 Vout (VDC) 12.12 Rt up (KΩ) 706.435 2 11.76 301.451 2 12.24 158.920 3 11.64 212.527 3 12.36 83.878 4 11.52 161.585 4 12.48 54.074 5 11.4 128.573 5 12.6 38.076 6 11.28 105.441 6 12.72 28.095 7 11.16 88.332 7 12.84 21.274 8 11.04 75.163 8 12.96 16.316 9 10.92 64.715 9 13.08 12.551 10 10.8 56.223 10 13.2 9.594 AM20EW-xx15S-NZ Trim down % 1 Vout (VDC) 14.85 Rt down (KΩ) 634.883 Trim up % 1 Vout (VDC) 15.15 Rt up (KΩ) 1460.098 2 14.7 400.637 2 15.3 192.573 3 14.55 288.513 3 15.45 96.641 4 14.4 222.758 4 15.6 61.354 5 14.25 179.536 5 15.75 43.016 6 14.1 148.959 6 15.9 31.781 7 13.95 126.187 7 16.05 24.191 8 13.8 108.568 8 16.2 18.720 9 13.65 94.532 9 16.35 14.590 10 13.5 83.086 10 16.5 11.361 AM20EW-xx24S-NZ, xx=24 or 48 Trim down % 1 2 Vout (VDC) 23.76 23.52 Rt down (KΩ) 1038.047 638.015 Trim up % 1 2 Vout (VDC) 24.24 24.48 Rt up (KΩ) 816.889 179.913 3 23.28 455.256 3 24.72 94.338 4 23.04 350.553 4 24.96 60.463 5 22.8 282.702 5 25.2 42.306 6 22.56 235.158 6 25.44 30.987 7 22.32 199.992 7 25.68 23.256 8 22.08 172.928 8 25.92 17.640 9 21.84 151.453 9 26.16 13.375 10 21.6 134 10 26.4 10.027 www.aimtec.com F 051e R13 Tel: +1 514 620 2722 4 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30EW-NZ 30 Watt | DC-DC Converter Derating Free Air Convection 55 º C without heat sink NOTE: With operations at 12V nominal input (9-18VDC) the output power will be rated at 80% only. 100 Output Power (%) 65 º C with heat sink 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 45 40 55 60 75 80 100 Ambient Temperature º C EMC recommended filter CY1 1nF/2KV LCM 1mH F1 +Vin MOV C1 +Vo C2 C3 -Vin C4 DC-DC Converter -Vo CY1 1nF/2KV Model MOV 24 Vin S14K35 48 Vin S14K60 C1 330 µF / 50V 330 µF / 100V C2 & C3 4.7 µF / 50V 2.2 µF / 100V C4 220µF for 3.3, 5 & 9 V output 100 µF for 12, 15 & 24 V output NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4 . All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13 Tel: +1 514 620 2722 5 of 5 Toll free: + 1 888 9 AIMTEC (924 6832) North America only