Click on Series name for product info on aimtec.com Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter FEATURES: 4000VAC I/O isolation Operating temperature: -40°C to +85°C Over load, Over voltage, Short circuit protection Universal Input: 90-260VAC, 47-440Hz, or 130-370VDC Energy star compliant RoHS compliant Low ripple and noise CE, cULus, CB approvals CB Models Single output Model Input Voltage (VAC/Hz) Input Voltage (VDC) AMEOS40-3.3SMAZ AMEOS40-5SMAZ AMEOS40-12SMAZ AMEOS40-15SMAZ AMEOS40-24SMAZ 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 130-370 130-370 130-370 130-370 130-370 Model Input Voltage (VAC/Hz) Input Voltage (VDC) AMEOS40-5DMAZ AMEOS40-12DMAZ AMEOS40-15DMAZ AMEOS40-24DMAZ 90-264/47-440 90-264/47-440 90-264/47-440 90-264/47-440 130-370 130-370 130-370 130-370 Output Voltage (V) Output Current max (A) 3.3 5 12 15 24 8 8 3.33 2.66 1.66 Efficiency (%) 78 82 84 83 82 Models Dual output Output Voltage (V) Output Current max(A) ±5 ±12 ±15 ±24 ±4 ±1.66 ±1.33 ±0.835 Efficiency (%) 80 85 82 77 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Conditions Typical Maximum 115 VAC 230 VAC 115 VAC 230 VAC 3.15 ≤0.5 117 1000 530 25 50 150 Conditions Typical Maximum (LL-HL) 0-100% load single 0-100% load dual 25% load - 1st out, 100% load – 2nd out Depending of the model 25% load Step 20MHz bandwidth 115VAC ±2 ±0.5 ±1 ±2 ±5 470-23 000 ±2 50 29 0 Current Inrush current <2ms Leakage current External fuse Input dissipation Start-up time Recommended slow blow type No load Units mA A µA A W ms Output Specifications Parameters Voltage accuracy Line regulation Load regulation Cross regulation Maximum Capacitive load Transient response deviation Ripple & Noise* Hold-up time (min) Minimum Load Current Units % % % % µF % of Vout mV p-p ms % of Max *Ripple & Noise measured with 0.1μF M/C and 1μF E/C www.aimtec.com F 052e R7.N Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter Isolation Specifications Parameters Conditions Tested I/O voltage Isolation Resistance Typical 60 sec Rated Units 4000 VAC MΩ >1000 General Specifications Parameters Conditions Switching frequency Protection class Over current protection Over voltage protection Short circuit protection Short Circuit restart Operating temperature Maximum case temperature Storage temperature Temperature coefficient Cooling Humidity Weight Dimensions (L X H X W) Typical 47 Class II 110 Zener diode clamp Hiccup mode, indefinite Auto recovery -40 - +85 Auto recovery With derating above 55ºC Maximum KHz 140 110 % % oC oC 100 oC -40 to +95 0.02 Free air convection Non condensing MTBF Units % / oC 95 145 4.92 x 2.32 x 1.02 inches 125 x 59 x 26mm, > 800,000 hrs (MIL-HDBK -217F, t=+25 oC)/Full Load > 200,000 hrs (MIL-HDBK -217F, t=at highest operating temperature)/Full Load % RH g Environment Approval Test Shock Vibration Parameters Conditions Wave form Acceleration amplitude Bump duration Converter operation Number of bumps Test mode Displacement Acceleration Converter operation Half sine wave 5gn 30 ms Before and after test, body mounted (on chassis) 18 (3 in each direction for every axis) Sweep sine, 10-100Hz, speed 0.05Hz/s 1 mm 3g, 3 loops 30min one cycle, 3h total, every axis tested Before and after test, body mounted (on chassis) Safety Specifications Parameters Agency approvals cULus, CE, CB Scheme IEC\EN\UL 60601-1, 2 x MOOP, CSA-C22.2 No. 601.1M90 EN 60950-1:2006+A11:2009 EN55011, class B IEC/EN 61000-3-2, Class A IEC/EN 61000-3-3, (EN60555-3) IEC 61000-4-2 Level 3 IEC 61000-4-3 Level 2 IEC 61000-4-4 Level 3 IEC 61000-4-5 Level 2 IEC 61000-4-6 Level 2 IEC 61000-4-8 Level 2 IEC 61000-4-11 Medical Electrical Equipment Standards www.aimtec.com F 052e R7.N Information technology Equipment EMI - Conducted and radiated emission Harmonic Current Emissions Voltage fluctuations and flicker Electrostatic Discharge Immunity RF, Electromagnetic Field Immunity Electrical Fast Transient/Burst Immunity Surge Immunity RF, Conducted Disturbance Immunity Power frequency Magnetic Field Immunity Voltage dips, Short Interruptions Immunity Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter Pin Out Specifications Pin Single Dual 1 2 3 4 5 6 AC Input (L) AC Input (N) +V Output -V Output N.C. N.C. AC Input (L) AC Input (N) +V Output Common Common -V Output N.C.= Not Connected Dimensions 59.00 (2.32) 59.00 (2.32) 51.1 (2.01) 1 2 3.50 (0.14) 116.7 (4.60) 125.00 (4.90) AC Input Screw Terminals 3.50 (0.14) Bottom View www.aimtec.com F 052e R7.N DC Output Screw Terminals 3 4 5 6 Top View Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AMEOS40-MAZ 40 Watt | AC-DC / DC-DC Converter Output Power (%) Derating Earth/Ground Connection EMC EN55022 class B compliant Application circuit L1 35mH ASE2501V‐G +Vout L 90-264VAC CX1 0.6uF CX2 0.6uF AMExw40‐MAZ N -Vout The Application circuit is EMC compliant for any type of Earth/Ground connection: Input Ground connection, Output Ground connection as shown or both sides, which is not recommended if the product Isolation is used as a Safety feature. NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 052e R7.N Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only