Teledyne FS24R10-06 Output to 20a 280 vac dc control Datasheet

Series FS
Output to 20A 280 Vac
DC Control
Part Number
Description
FS24R10-06
10A, 280 Vac
FS24D10-06
10A, 280 Vac
FS24D10
10A, 280 Vac
FS24D20-06
20A, 280 Vac
Part Number Explanation
FS
24
R
10
-06
FEATURES/BENEFITS
• Miniature size package
• Designed for medium-power applications
• Faston or PCB terminals available
• Tight zero-cross window for low EMI
• Excellent thermal performance
• High immunity to surges
NOTES
1) Line Voltage (nominal): 24 = 240 Vac
2) Switch Type: R = Random turn-on; D = Zero-cross turn-on;
3) Feature: -06 = Faston terminals
MECHANICAL SPECIFICATION
.19x.03
(4.8x0.8)
.25x.03
(6.35x0.8)
.46 (11.6)
.39
(10)
.34
(8.6)
.32 (8)
.25 (6.4)
.98 (25)
.59 (15)
.08 (2)
1.4 (35.5)
1.18 (30)
WEIGHT: 3.2 oz. (90g)
DESCRIPTION
The Series FS relays are designed for medium-power
loads. The design incorporates a triac output. The
Series FS relays utilize optical isolation to protect the
control from load transients. The FS compact
package is available with faston or PCB terminals.
Its compact size makes it ideal for designs where
space is limited. The Series FS relays have excellent
thermal performance.
.5 (12.7)
2
-4
APPLICATIONS
• Heating control
• Motor control
• Uninterruptible power supplies
• Light dimmers
• Industrial and process control
• On/Off controls of medium-power AC equipment
• Electromechanical line relay replacement
.83 (21)
.16 (4)
1
+3
.83 (21)
Figure 1a — FS relays except FS24D10
Ø 0.5 (1.32)
.24 (6)
.83 (21)
.59 (15)
APPROVALS
All models are UL recognized.
UL File Number E128555.
.08 (2)
1.4 (35.5)
WEIGHT: 3.2 oz. (90g)
1.18 (30)
EQUIVALENT CIRCUIT
.5 (12.7)
2
–4
.2 (5.06)
.16 (4)
3+
R
1~
.3 (7.62)
.83 (21)
+3
1
.83 (21)
4–
ZERO
CROSS
2~
Figure 1b — FS24D10
Figure 2 — FS relays
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
FS 1
FS\032003\Q1
Series FS
INPUT (CONTROL) SPECIFICATION
CONTROL CHARACTERISTIC
Min
Max
Units
FS24R
3
30
Vdc
FS24D
4
30
Vdc
FS24R
2
30
mAdc
FS24D
3
30
mAdc
1
Vdc
Input Current Range
Must Turn-Off Voltage
Input Current (mA)
Control Range
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0
All relays
2
4
6
8 10 12 14 16 18 20 22 24 26 28 30
Control Voltage (V)
Figure 3 — FS relays
Input Resistance (Typical)
All relays
1000
Ohms
OUTPUT (LOAD) SPECIFICATION (Continued)
Min
Reverse Voltage Protection
All relays
30
V
Max
Units
Zero Cross Window (Typical)
FS24
R
NA
FS24
D
12
Vac
3
mA
FS24R
0.1
ms
FS24D
8.3
ms
8.3
ms
500
V/µs
50
A/µs
0.1
440
Hz
10A output current
.005
72
A2S
20A output current
.005
200
A2S
OUTPUT (LOAD) SPECIFICATION
Input Type
Min
Max
Units
Operating Range
Off-State Leakage Current (60Hz)
All relays
All relays
12
280
Vrms
Turn-On Time (60 Hz)
Peak Voltage
All relays
600
Vpeak
Load Current Range (Resistive)
Turn-Off Time (60 Hz)
10A output current
.005
10
Arms
20A output current
.005
20
Arms
All relays
Off-State dv/dt
Inductive Load Current
All relays
10A output current
2.5
Arms
20A output current
4
Arms
Maximum di/dt (Non-Repetitive)
All relays
Maximum Surge Current Rating (Non-Repetitive)
10A output current
120
A
20A output current
200
A
On-State Voltage Drop
All relays
I2t for Match Fusing (<8.3ms)
All relays output current
FS 2
Operating Frequency Range
1.3
V
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2003 TELEDYNE RELAYS
FS\032003\Q1
Series FS
ENVIRONMENTAL SPECIFICATION
SURGE CURRENT
Min
Max
Units
Operating Temperature
–40
100
°C
Storage Temperature
–40
100
°C
150
Apeak
100
Input-Output Isolation
4000
Vrms
Output-Case Isolation
2500
Vrms
Non-Repetitive
50
Repetitive with initial Tj = 70°C
0
0.01
0.1
1
t (s)
10
Figure 4a — All 10A FS relays output current
NOTES:
1. External snubber is recommended when switching inductive
loads.
2. Electrical specifications at 25°C unless otherwise specified.
3. For 800Hz applications, contact factory.
4. For additional/custom options, contact factory.
Overload Current (A)
200
180
160
140
120
100
80
60
40
20
0
1
10
100
1000
Number of Cycles
Figure 4b — FS24D20-06 output current
THERMAL CHARACTERISTICS
13
9
8
90°C
Power Dissipation (W)
10
0°C/W
2°C/W
/W
4 °C
11
7
6
5
NO
HE
AT
SIN
K
4
3
Max Case Temperature (°C)
12
2
1
0
0
1
2
3
4
5
6
7
8
9
10
0
10
20
30
Load Current (Arms)
40
50
60
70
80
90
100 110 120 125
Ambient Temperature (°C)
Figure 5a — All 10A FS relays output current
35
W
70
80
25
4°
C/
20
90
W
100°C
15
10
NO H
EAT S
IN
5
Max Case Temperature (°C)
Power Dissipation (W)
2°
C/
/W
0°C
W
C/
1°
W
C/
2°
1.
W
C/
5°
1.
30
K
0
0
5
10
15
Load Current (Arms)
20 0
10 20 30 40 50 60 70 80 90 100 110 120 125
Ambient Temperature (°C)
Figure 5b — FS24D20-06 output current
© 2003 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
FS 3
FS\032003\Q1
Similar pages