XP Power GCS180PS24 Convection/forced cooled rating Datasheet

ACDC
150/180 Watts
GCS Series
xppower.com
•
Convection/Forcedcooled Ratings
•
IT & Medical Safey Approvals (Class I & II)
•
< 0.5W Standby Power
•
40° C to +70° C Operation
•
Remote On/Off (R Models)
•
Class B Emissions
•
3 Year Warranty
Specification
Input
• 85-264 VAC, derate output power
<90 VAC by 10%
Input Frequency
• 47-63 Hz
Input Current
• 1.5/1.8 A typical at 115 VAC, full load
(150/180 W)
0.7/0.8 A typical at 230 VAC, full load
(150/180 W)
Inrush Current
• 80 A typical at 230 VAC, cold start at 25 °C
Power Factor
• EN61000-3-2, class A Compliant
(Class C > 50 W load)
Earth Leakage Current • 200 µA max at 264 VAC/60 Hz
No Load Input Power • <0.5 W
Input Protection
• Internal T3.15 A/250 V fuse in line
and neutral
Input Voltage
Output
• 12-48 VDC (see Models & Ratings table)
• ±2%, fan output will track by
same percentage
Initial Set Accuracy
• ±1% V1, ±5% V Fan
Minimum Load
• None
Start Up Delay
• 0.5 s max
Hold Up Time
• 18 ms typical
Drift
• ±0.2% after 20 min warm up
Line Regulation
• ±0.5% max
Load Regulation
• ±0.5% V1, ±5% V Fan
Over/Undershoot
• 12 - 28 V models none,
48 V models typically 5%
Transient Response
• 4% max. deviation, recovery to within
1% in 500 µs for a 50-75-50% load
change
Ripple & Noise
• 1% pk-pk V1, 12 V models 1.5%,
20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overload Protection
• 110-150% V1 only
Short Circuit Protection • Continuous
Temperature
• 0.05%/˚C
Coefficient
Remote Sense
• Compensates for 0.5 V total voltage drop
Remote On/Off
• Optional, -R models (see longform
datasheet for full details)
Output Voltage
Output Voltage Trim
General
Efficiency
Isolation
Switching Frequency
MTBF
Power Density
• 93% typical
• 4000 VAC Input to Output 2 x MOPP,
1500 VAC Input to Ground 1 x MOPP,
500 VDC Output to Ground
• 65/100 KHz PFC/Main Converter
• 569 kHrs to MIL-HDBK-217F at 25 °C, GB
• 8.5 W/in3
Environmental
Operating Temperature • -40 ˚C to +70 ˚C derate linearly from +50
°C at 2.5%/˚C to 50% load at +70 °C
Cooling
• Convection & Fan cooled ratings (see
Models & Ratings tables)
Operating Humidity
• 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude
• 3048 m
Shock
• ±3 x 30g shocks in each plane, total 18
shocks. 30g = 11ms (+/-0.5msec), half
sine, conforms to EN60068-2-27 &
EN60068-2-47
Vibration
• Single axis 10 - 500 Hz at 2g sweep and
endurance at resonance in all 3 planes.
Conforms to EN60068-2-6
EMC & Safety
Low Voltage PSU EMC • EN61204-3, high severity level
Emissions
• EN55011/22 level B conducted
EN55011/22 level B radiated (GCS180
level A)
Harmonic Currents
• EN61000-3-2, class A & C
Voltage Flicker
• EN61000-3-3
Radiated Immunity
• EN61000-4-3, level 3 Perf Criteria A
EFT/Burst
• EN61000-4-4, level 3 Perf Criteria A
Surge
• EN61000-4-5, installation class 3
Perf Criteria A
Conducted Immunity
• EN61000-4-6, level 3 Perf Criteria A
Dips & Interruptions
• EN55024 & EN60601-1-2 (see longform
datasheet for details)
Safety Approvals
• EN60601-1, ANSI/AAMI ES60601-1,
CSA22.2 No. 60601-1 per cUL, Including
Risk Management, EN60950, UL60950
Output Current V1
Convection Cooled
Forced Cooled (7 CFM)
9.2 A
12.5 A
7.3 A
10.0 A
4.6 A
6.3 A
3.9 A
5.4 A
2.3 A
3.2 A
Output Voltage V1
12.0
15.0
24.0
28.0
48.0
VDC
VDC
VDC
VDC
VDC
12.0
15.0
24.0
28.0
48.0
VDC
VDC
VDC
VDC
VDC
12.5
10.0
6.3
5.4
3.1
A
A
A
A
A
15.0
12.0
7.5
6.4
3.7
Output Voltage (Vfan)
& Current
A
A
A
A
A
Maximum Output Power
Model Number(1,2,3,4)
12.0
12.0
12.0
12.0
12.0
VDC/0.6
VDC/0.6
VDC/0.6
VDC/0.6
VDC/0.6
A
A
A
A
A
157
157
157
157
157
W
W
W
W
W
GCS150PS12
GCS150PS15
GCS150PS24
GCS150PS28
GCS150PS48
12.0
12.0
12.0
12.0
12.0
VDC/0.6
VDC/0.6
VDC/0.6
VDC/0.6
VDC/0.6
A
A
A
A
A
187
187
187
187
187
W
W
W
W
W
GCS180PS12
GCS180PS15
GCS180PS24
GCS180PS28
GCS180PS48
Notes
1. Add suffix -C for convection cooled cover, e.g. GCS150PS12-C.
2. Add suffix -EF for fan cooled cover with end fan e.g. GCS150PS12-EF. Note
Vfan output no longer available.
3. Add suffix -TF for fan cooled cover with top fan, e.g. GCS150PS12-TF.
Note Vfan output no longer available.
4. Add suffix -R for remote on/off, e.g. GCS150PS12-R, GCS150PS12-RC with
convection cover or GCS150PS12-REF/GCS150PS12-RTF with fan covers.
Mechanical Details
Note: Mounting points A should be connected
together for optimum EMI performance
5.0 (127.0)
0.225 (5.72)
4.5 (115.57)
1.42
(36.3)
0.20 (5.1)
T1
Q3
3.00
(76.2)
AIRFLOW
2.15
(54.6)
C45
A
2.40
(61.0)
C23
2.55
(64.7)
C6
Q1
C28
L3
A
A
0.225 (5.72)
0.20 (5.1)
0.25 Faston Ground Tab
Signal Connector
Molex pn. 09-65-2068
Pin
1
2
Function
Line
Neutral
Pin
1
2
3
4
5
6
Single Output
+V1
+V1
+V1
RTN
RTN
RTN
1.18
(29.8)
0.14 (3.5)
4 x 0.156 (3.96) mounting holes
ø.312 (7.92) clearance top and bottom
Input Connector J1
Molex pn. 09-65-2038
0.61
(15.6)
0.18 (4.6)
0.15 (3.8)
SMD Component Height
Signal Connector
Molex pn. 09-65-2068
Fan Connector J3
Molex pn. 22-04-1021
Pin
1
2
Function
Fan +(12 V)
Fan -
Pin
1
2
3
4
5
6
7
8
9
10
Single Output
+Sense
-Sense
XP Internal Use
Inhibit LO
Inhibit HI
N/C
N/C
N/C
N/C
N/C
Notes
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing
Pn. 09-50-161 and both with Molex series 5194 crimp terminals. J4 mates with
JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals.
J3 mates with Molex Housing Pn. 22-01-1024 and with Molex series 5103
crimp terminals.
ACDC
GCS150/180
Models and Ratings
Convection (C)
0.39
(10.0)
4.72 (120.0)
4 x M3 x 0.5 THD
0.16 (4.0) max
screw penetration
0.93
(23.7)
5.50 (139.7)
1
1
3.48
(88,5)
10 1 2
J4
1
2
Pin
1
2
2.64
(67.0)
0.85
(21.6)
0.43
(10.8)
0.45
(11.4)
0.25 Faston
Ground Tab
J3
6
J2
J1
Input Connector J1
Molex pn. 09-65-2038
2
2.39
(60.7)
0.45
(11.4)
4 x M3 x 0.5 THD
0.16 (4.0) max
screw penetration
Pin
1
2
3
4
5
6
7
8
9
10
4.72 (120.0)
0.39
(10.0)
4.72 (120.0)
2 x M3 x 0.5 THD
0.16 (4.0) max screw
penetration
0.93
(23.7)
Single Output
+V1
+V1
+V1
RTN
RTN
RTN
Signal Connector
Molex pn. 09-65-2068
0.76
(19.3)
Top Fan (TF)
Pin
1
2
3
4
5
6
1.96
(50.0)
0.39
(10.0)
Function
Line
Neutral
Signal Connector
Molex pn. 09-65-2068
1.70
(43.2)
Single Output
+Sense
-Sense
XP Internal Use
Inhibit LO
Inhibit HI
N/C
N/C
N/C
N/C
N/C
5.5 (139.7)
1
0.25 Faston
Ground Tab
0.43
(10.8)
3.48
(88,5)
2.64
(67.0)
Notes
J4
10 1 2
1
0.45
(11.4)
J3
6
J2
1
J1
2
2.39
(60.7)
2
ACDC
GCS150/180
Models and Ratings
0.85
(21.6)
0.45
(11.4)
2.2
(57.8)
1.7
(43.2)
4 x M3 x 0.5 THD
0.16 (4.0) max
screw penetration
1.96
(50.0)
0.76
(19.3)
0.39
(10.0)
4.72 (120.0)
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
3. J1 mates with Molex Housing Pn. 09-50-1031.
J2 mates with Molex Housing Pn. 09-50-161
and both with Molex series 5194 crimp
terminals. J4 mates with JST Housing Pn.
PHDR-10VS and with JST SPHD-001T-P0.5
crimp terminals. J3 mates with Molex Housing
Pn. 22-01-1024 and with Molex series 5103
crimp terminals.
End Fan (EF)
6.35 (161.3)
0.43
(10.8)
J4
J3
6
1
0.45 (11.4)
0.25 Faston (Right Angle) Ground Tab
1.70
(43.2)
0.93
(23.7)
0.39 (10.0)
Pin
1
2
3
4
5
6
Single Output
+V1
+V1
+V1
RTN
RTN
RTN
Signal Connector
Molex pn. 09-65-2068
4.72 (120.0)
Pin
1
2
3
4
5
6
7
8
9
10
4 x M3 x 0.5 THD
0.16 (4.0) max
screw penetration
0.76
(19.3)
1.96
(50.0)
0.39
(10.0)
J1
2
1
0.45 (11.4)
2 x M3 x 0.5 THD
0.16 (4.0) max
screw penetration
Signal Connector
Molex pn. 09-65-2068
1.10
[27.8]
0.84
(21.5)
5.50 (139.7)
Function
Line
Neutral
J2
2.63
(66.9)
10 1 2
3.48
(88.5)
Pin
1
2
1
2
1.90
(48.2)
Input Connector J1
Molex pn. 09-65-2038
Single Output
+Sense
-Sense
XP Internal Use
Inhibit LO
Inhibit HI
N/C
N/C
N/C
N/C
N/C
4.72 (120.0)
Notes
1. All dimensions in inches (mm).
2. Tolerance .xx = ±0.02 (0.50); .xxx = ±0.01 (0.25)
3. J1 mates with Molex Housing Pn. 09-50-1031. J2 mates with Molex Housing
Pn. 09-50-161 and both with Molex series 5194 crimp terminals. J4 mates with
JST Housing Pn. PHDR-10VS and with JST SPHD-001T-P0.5 crimp terminals.
J3 mates with Molex Housing Pn. 22-01-1024 and with Molex series 5103
crimp terminals.
Thermal Considerations
In order to ensure safe operation of the PSU in the end-use equipment, the temperature of the components listed in the table below must not be
exceeded. Temperature should be monitored using K type thermocouples placed on the hottest part of the component (out of any direct air flow).
See Mechanical Details for component locations. See longform datasheet for further information and service life estimates.
Component
T1 Coil
L3 Coil
Q1 Body
Q3 Body
C6
C23
Temperature Measurements (Ambient 50 °C)
Max Temperature °C
120 °C
120 °C
120 °C
120 °C
105 °C
105 °C
24-Apr-13
ACDC
GCS150/180
Models and Ratings
Similar pages