Surge Protection Module LED Lighting Surge Protection Module > LSP10GIHP LSP10GIHP Module Series RoHS Description The Littelfuse LSP10GIHP thermally protected Surge Protective Device is a self-protected device which is specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It is constructed with Littelfuse thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under the extreme circumstances of varistor end-of-life or sustaining over voltage conditions. The LSP10GIHP provides coordinated surge protection with more LED drivers than other SPDs due to its exceptionally low Measured Limiting Voltage (MLV) and Voltage Protection Level (Up). This lower clamping voltage can also help to extend the life-time of the luminaire. It also features a built-in LED indicator that notifies when replacement of the module is needed. Agency Approvals Agency Standard Agency File Number UL 1449 E320116 IEC 61643-11/EN 61643-11 for 277V Product 3187362.01 Additional Information Datasheet Resources Samples Features • Suitable for use in luminaire with Class I or Class II installations* • Low MLV and Up • Built-in LED Indication, saves maintenance time by identifying replacement need • Thermally Protected • Double insulation cable wire • 20kA Maximum Discharge Current (Imax), 8/20µs • Meets ANSI C82.77-5-2015: Location C High • Meets ANSI C136.2-2015: Extreme Level • Meets IEEE C62.41.2: Location Category C High • Meets US Dept. of Energy MSSSLC Model Spec. • High line-to-earth/ground resistance • IP66 - Dust-tight and water resistant • Series connected • UL 1449 and IEC 61643-11/EN 61643-11 recognized* • RoHS compliant * See Part Numbering System for exact details of voltages available for Class I and Class II installations and Device Ratings and Specification table for voltage specific approvals. Applications • • • • • • • • • Outdoor and Commercial LED Lighting Roadway lighting Traffic lighting Digital signage Wall wash lighting Parking garage/lot lighting Flood lighting Tunnel lighting Street lighting © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 09/09/16 Surge Protection Module LED Lighting Surge Protection Module > LSP10GIHP Absolute Maximum Ratings • For ratings of individual members of a series, see Device Ratings and Specifications chart LSP10GIHP Series Units Continuous: Steady State Applied Voltage: Max AC Voltage Range (VM(AC)RMS) 150 to 510 V 5 A Maximum Discharge Current, 8/20μs Waveform (Imax) 20,000 A Nominal Discharge Current, 8/20µs Waveform (In) 10,000 A Operating Ambient Temperature Range (TA) -45 to +75 °C Storage Temperature Range (TSTG) -45 to +85 °C Continuous Current Transient: Isolation Voltage Capability (When the thermal disconnect opens) Insulation Resistance 600 V >1,000 MΩ CAUTION: Stresses above those listed in ‘Absolute Maximum Ratings’ may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. LSP10GIHP Series Device Ratings and Specifications Part Number Operating Voltage (VAC) MCOV/UC 1 (VAC) Maximum Discharge Current 2 Imax (A) Nominal Discharge Current 3 In (A) MLV 4 (V) Up (V) LSP10GIHP277S 120-277 320 20,000 10,000 L-N: 810 L-G: 1560 N-G: 1570 LSP10GIHP480S 347-480 510 20,000 10,000 L-N: 1400 L-G: 1560 N-G: 1570 Safety Compliance 5 IEC/EN 61643-11 UL1449 L-N: 1000 L-G/PE: 3800 N-G/PE: 2900 X X -- -- X Glossary: 1. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. 2. Maximum Discharge Current Imax (A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20µs current waveform. All Devices pass maximum discharge current with possible, safe opening of thermal disconnect. 3. Nominal Discharge Current In (A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20µs current waveform. 4. MLV: UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In); an average voltage value of 15 impulses. 5. Up: IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20µs nominal discharge current (In); a rounding voltage value of maximum measurement. Specification Value Condition 120-277V Temporary Overvoltage (V) TOV UT @ tT = 5 s 403 LV System Fault for TN Power Grid Temporary Overvoltage (V) TOV UT @ tT = 120 min 529 LV System Fault for TN Power Grid Power grids TN Backup fuse (A) 21 Maximum gG Fuse End of life indication Yes Optical Light ON: SPD is functional Light OFF: SPD has reached end-of-life Max earth leakage current at Uc (μA) 50 IEC 61643-11 Test Classification Test Class II and III EN 61643-11 Type Classification Type 2 and 3 UL 1449 Type © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 09/09/16 4CA Surge Protection Module LED Lighting Surge Protection Module > LSP10GIHP Repetitive Surge Capability Pulse Rating (8x20µSec) 100000 MODEL SIZE = 20MM TA = -55oC TO 85oC 130 to 625VM(AC) RATING SURGE CURRENT (A) Strikes Surge 1 20,000A 2 15,000A 15 10,000A 100 3,000A 1,000 1,600A 1,0000 650A 1,00,000 400A 1,000,000 240A 1 10000 2 15 10 2 1000 10 4 5 10 10 6 10 3 100 ∞ 10 1 10 100 1000 10000 IMPULSE DURATION (μs) LSP10GIHP Series Wire Specification Part Number Extension Length Diameter Double Insulation Installation Class Color X3333 250mm ± 20mm 1mm2 Yes I L - Brown N - Blue G/PE - Green with Yellow stripe X3316 250mm ± 20mm 1mm2 Yes II L - Brown N - Blue None 250mm ± 20mm 16AWG Yes -- L - Black N - White G - Green Dimensions LED Indication 32.00±1.50 Ø6.40±0.30 Input 58.68 ±2.00 Output 18.08±1.50 67.68 ±2.00 250±20 71.63±2.00 250±20 Note: Dimensions are in millimeter (mm) © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 09/09/16 Surge Protection Module LED Lighting Surge Protection Module > LSP10GIHP Part Numbering System Application/Installation Schematic LSP 10G I HP 480 S Xxxxx L L AC/DC N N Power G/PE G Supply Littelfuse Surge Protection Module 10kA (Nominal Discharge Current) Built-in LED indication SPD X3333 High Performance Version Series Connection Operating Voltage L L N N S: Series Connection AC/DC Power Supply G/PE SPD X3316 Series Connection (for Class II Unearthed) Notes: 1. Green LED light on: SPD is good 2. Green LED light off: SPD needs replacement © 2016 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 09/09/16 Other non-standard option: X3333: with GND wire connection, available at a 277Vac rating, CE marked, for Class I installations, earthed. Wire Color: Line: Brown, Neutral: Blue, Ground/PE: Green with yellow stripe X3316: without GND wire connection, available at a 277Vac rating, CE marked, for Class II installations, unearthed. Wire Color: Line: Brown, Neutral: Blue