Series AM6TW-VZ 6 Watt | DC-DC Converter FEATURES: • • • • Models Single output Model AM6TW-2412S-VZ AM6TW-2415S-VZ AM6TW-4812S-VZ AM6TW-4815S-VZ Input Voltage (V) Output Voltage (V) 9-36 9-36 18-72 18-72 12 15 12 15 Input Voltage (V) Output Voltage (V) 9-36 9-36 18-72 18-72 AM6TW-2412SH35-VZ AM6TW-2415SH35-VZ AM6TW-4812SH35-VZ AM6TW-4815SH35-VZ Models Dual output Model AM6TW-2412D-VZ AM6TW-2415D-VZ AM6TW-4812D-VZ AM6TW-4815D-VZ AM6TW-2412DH35-VZ AM6TW-2415DH35-VZ AM6TW-4812DH35-VZ AM6TW-4815DH35-VZ Input Specifications Parameters Voltage Range Filter Start up time Peak Input Voltage time Absolute Max Rating Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R13.B Wide Input Range (4:1) 24 Pin DIP Package Metal package High efficiency up to 79% 9-36 9-36 18-72 18-72 9-36 9-36 18-72 18-72 12 15 12 15 ±12 ±15 ±12 ±15 ±12 ±15 ±12 ±15 • • • • Output Current max (mA) 500 400 500 400 500 400 500 400 Output Current max (mA) ±250 ±200 ±250 ±200 ±250 ±200 ±250 ±200 Nominal Typical 24 Vin 48 Vin 20 15 -0.7-40 -0.7-80 24 48 Conditions 3 sec Operating temperature -40oC to + 85oC Input / Output isolation 1500 or 3500VDC Pin compatible with multiple manufacturers Continuous short circuit protection 9-36 18-72 Typical > 1000 60 Tel: +1 514 620 2722 1 of 3 Capacitive load, max (μF) 470 470 470 470 Efficiency (%) 470 470 470 470 75 77 77 77 75 77 77 77 Capacitive load, max (μF) Efficiency (%) ±220 ±220 ±220 ±220 ±220 ±220 ±220 ±220 Maximum 79 79 75 77 79 79 75 77 Units VDC π (Pi) Network Ms Ms VDC Rated 1500 (3500 H35 Model) Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6TW-VZ Output Specifications Parameters Voltage Balance Voltage accuracy Short circuit protection Short circuit restart Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Conditions Typical Balanced Load ±1 ±1 ±0.5 ±0.5 ±0.02 60 At 20MHz Bandwidth General Specifications Parameters Switching frequency Operating temperature Storage temperature Max Case temperature Cooling Humidity Case material Weight Dimensions(L x W x H) MTBF 6 Watt | DC-DC Converter Conditions Maximum Continuous Auto Recovery Typical 100% load Full Load (see derating chart) 100-400 Free air convection % % % % %/oC mV p-p Maximum -40 to +85 -40 to +125 Units 100 Units KHz o C o C o C 95 % Nickel coated copper 15 g Tolerance ±0.5 mm or ±0.02 inches 1.25 x 0.8 x 0.4 inches 31.75 x 20.32 x 10.16 mm >2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) Safety Specifications Parameters Standards Designed to meet IEC 60950-1 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Pin Out Specifications Pin 1 2 3 9 10 11 12/13 14 15 16 22 23 24 Single +V Input N.C. N.C. No pin -V Output +V Output -V Input +V Output -V Output No pin N.C. N.C. +V Input www.aimtec.com F 051e R13.B 1500VDC Dual +V Input -V Output Common No pin Common +V Output -V Input +V Output Common No pin Common -V Output +V Input Single 3500VDC No pin -V Input -V Input No pin No pin N.C. No pin +V Output No pin -V Output +V Input +V Input No pin Tel: +1 514 620 2722 2 of 3 Dual No pin -V Input -V Input Common No pin -V Output No pin +V Output No pin Common +V Input +V Input No pin Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM6TW-VZ 6 Watt | DC-DC Converter Dimensions 27.94 (1.10) 31.75 (1.25) 20.32 (0.80) 0.25 (0.01) 1 2 3 9 10 1112 Bottom View 24 23 22 15.24 (0.60) 0.50 (0.02) 16 15 14 13 2.54 (0.10) Printed Face Built-in Stand-offs to ease PCB cleaning 3.05 (0.12) 10.16 (0.40) All dimensions are typical: millimeters (inches) Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002) Pin Pitch Tolerance: ± 0.35 (±0.014) Case Tolerence: ± 0.5 (±0.02) Derating Free Air Convection 85 º C Output Power % 100 80 60 Safe Operating Area 40 20 0 -40 0 25 50 75 85 100 Ambient Temperature º C NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R13.B Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only