AIMTEC AM6TW-2412DH35-VZ 6 watt | dc-dc converter Datasheet

Series AM6TW-VZ
6 Watt | DC-DC Converter
FEATURES:
•
•
•
•
Models
Single output
Model
AM6TW-2412S-VZ
AM6TW-2415S-VZ
AM6TW-4812S-VZ
AM6TW-4815S-VZ
Input Voltage
(V)
Output Voltage
(V)
9-36
9-36
18-72
18-72
12
15
12
15
Input Voltage
(V)
Output Voltage
(V)
9-36
9-36
18-72
18-72
AM6TW-2412SH35-VZ
AM6TW-2415SH35-VZ
AM6TW-4812SH35-VZ
AM6TW-4815SH35-VZ
Models
Dual output
Model
AM6TW-2412D-VZ
AM6TW-2415D-VZ
AM6TW-4812D-VZ
AM6TW-4815D-VZ
AM6TW-2412DH35-VZ
AM6TW-2415DH35-VZ
AM6TW-4812DH35-VZ
AM6TW-4815DH35-VZ
Input Specifications
Parameters
Voltage Range
Filter
Start up time
Peak Input Voltage time
Absolute Max Rating
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R13.B
Wide Input Range (4:1)
24 Pin DIP Package
Metal package
High efficiency up to 79%
9-36
9-36
18-72
18-72
9-36
9-36
18-72
18-72
12
15
12
15
±12
±15
±12
±15
±12
±15
±12
±15
•
•
•
•
Output Current
max (mA)
500
400
500
400
500
400
500
400
Output Current
max (mA)
±250
±200
±250
±200
±250
±200
±250
±200
Nominal
Typical
24 Vin
48 Vin
20
15
-0.7-40
-0.7-80
24
48
Conditions
3 sec
Operating temperature -40oC to + 85oC
Input / Output isolation 1500 or 3500VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
9-36
18-72
Typical
> 1000
60
Tel: +1 514 620 2722
1 of 3
Capacitive load,
max (μF)
470
470
470
470
Efficiency
(%)
470
470
470
470
75
77
77
77
75
77
77
77
Capacitive load,
max (μF)
Efficiency
(%)
±220
±220
±220
±220
±220
±220
±220
±220
Maximum
79
79
75
77
79
79
75
77
Units
VDC
π (Pi) Network
Ms
Ms
VDC
Rated
1500 (3500 H35
Model)
Units
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6TW-VZ
Output Specifications
Parameters
Voltage Balance
Voltage accuracy
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Conditions
Typical
Balanced Load
±1
±1
±0.5
±0.5
±0.02
60
At 20MHz Bandwidth
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
6 Watt | DC-DC Converter
Conditions
Maximum
Continuous
Auto Recovery
Typical
100% load
Full Load (see derating chart)
100-400
Free air convection
%
%
%
%
%/oC
mV p-p
Maximum
-40 to +85
-40 to +125
Units
100
Units
KHz
o
C
o
C
o
C
95
%
Nickel coated copper
15
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
1
2
3
9
10
11
12/13
14
15
16
22
23
24
Single
+V Input
N.C.
N.C.
No pin
-V Output
+V Output
-V Input
+V Output
-V Output
No pin
N.C.
N.C.
+V Input
www.aimtec.com
F 051e R13.B
1500VDC
Dual
+V Input
-V Output
Common
No pin
Common
+V Output
-V Input
+V Output
Common
No pin
Common
-V Output
+V Input
Single
3500VDC
No pin
-V Input
-V Input
No pin
No pin
N.C.
No pin
+V Output
No pin
-V Output
+V Input
+V Input
No pin
Tel: +1 514 620 2722
2 of 3
Dual
No pin
-V Input
-V Input
Common
No pin
-V Output
No pin
+V Output
No pin
Common
+V Input
+V Input
No pin
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6TW-VZ
6 Watt | DC-DC Converter
Dimensions
27.94
(1.10)
31.75
(1.25)
20.32
(0.80)
0.25
(0.01)
1 2 3
9 10 1112
Bottom View
24 23 22
15.24
(0.60)
0.50
(0.02)
16 15 14 13
2.54
(0.10)
Printed Face
Built-in Stand-offs to
ease PCB cleaning
3.05
(0.12)
10.16
(0.40)
All dimensions are typical: millimeters (inches)
Pin Diameter: 0.50 ± 0.05 (0.02 ± 0.002)
Pin Pitch Tolerance: ± 0.35 (±0.014)
Case Tolerence: ± 0.5 (±0.02)
Derating
Free Air Convection
85 º C
Output Power %
100
80
60
Safe Operating Area
40
20
0
-40
0
25
50
75
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Similar pages