Panasonic AGN200S24 High sensitivity, with 100mw nominal operating power, in a compact and space saving case Datasheet

GN (AGN)
High Sensitivity, with
100mW nominal operating
power, in a compact and
space saving case
GN RELAYS (AGN)
FEATURES
1. Compact slim body saves space
Thanks to the small surface area of 5.7
mm × 10.6 mm .224 inch × .417 inch
and low height of 9.0 mm .354 inch,
the packaging density can be
increased to allow for much smaller
designs.
2. High sensitivity single side stable
type (Nominal operating power:
100mW) is available
3. Outstanding surge resistance.
Surge breakdown voltage between
contacts and coil:
2,500 V 2×10 µs (Telcordia)
Surge breakdown voltage between
open contacts:
1,500 V 10×160 µs (FCC part 68)
4. The use of twin crossbar contacts
ensures high contact reliability.
AgPd contact is used because of its
good sulfide resistance. Adopting lowgas molding material. Coil assembly
molding technology which avoids
generating volatile gas from coil.
5. Increased packaging density
Due to highly efficient magnetic circuit
design, leakage flux is reduced and
changes in electrical characteristics
from components being mounted
RoHS compliant
close-together are minimized. This all
means a packaging density higher
than ever before.
6. Nominal operating power: 140 mW
7. Outstanding vibration and shock
resistance.
Functional shock resistance: 750 m/s2
Destructive shock resistance:
1,000 m/s2
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
3.3 mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of
5 mm .197 inch)
8. Sealed construction allows
automatic washing.
TYPICAL APPLICATIONS
1. Telephonic equipment
2. Telecommunications equipment
3. Security equipment
4. Test and Measurement equipment
5. Electronic Consumer and Audio
Visual equipment
ORDERING INFORMATION
AGN 2
0
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
6: High sensitivity single side
stable type
Type of operation
0: Standard type (B.B.M.)
Terminal shape
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
Nominal coil voltage (DC)
1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V
12: 12V 24: 24V
Packing style
Nil: Tube packing
X: Tape and reel packing (picked from 1/2/3/4 pin side)
Z: Tape and reel packing (picked from 5/6/7/8 pin side)
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB13E 201209-T
GN (AGN)
TYPES
1. Standard PC board terminal
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
6V DC
9V DC
12V DC
24V DC
Single side stable
Part No.
AGN2001H
AGN20003
AGN2004H
AGN20006
AGN20009
AGN20012
AGN20024
1 coil latching
Part No.
AGN2101H
AGN21003
AGN2104H
AGN21006
AGN21009
AGN21012
AGN21024
High sensitivity single side stable
Part No.
AGN2601H
AGN26003
AGN2604H
AGN26006
AGN26009
AGN26012
AGN26024
Single side stable
Part No.
AGN2001H
AGN20003
AGN2004H
AGN20006
AGN20009
AGN20012
AGN20024
1 coil latching
Part No.
AGN2101H
AGN21003
AGN2104H
AGN21006
AGN21009
AGN21012
AGN21024
High sensitivity single side stable
Part No.
AGN2601H
AGN26003
AGN2604H
AGN26006
AGN26009
AGN26012
AGN26024
1 coil latching
Part No.
AGN2101HZ
AGN21003Z
AGN2104HZ
AGN21006Z
AGN21009Z
AGN21012Z
AGN21024Z
High sensitivity single side stable
Part No.
AGN2601HZ
AGN26003Z
AGN2604HZ
AGN26006Z
AGN26009Z
AGN26012Z
AGN26024Z
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2. Surface-mount terminal
1) Tube packing
Nominal coil voltage
1.5V DC
3V DC
4.5V DC
6V DC
9V DC
12V DC
24V DC
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2) Tape and reel packing
Nominal coil voltage
Single side stable
Part No.
AGN2001HZ
AGN20003Z
AGN2004HZ
AGN20006Z
AGN20009Z
AGN20012Z
AGN20024Z
1.5V DC
3V DC
4.5V DC
6V DC
9V DC
12V DC
24V DC
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed.
RATING
1. Coil data
1) Single side stable type
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
140mW
150%V of
nominal voltage
1.5V DC
93.8mA
16Ω
3V DC
4.5V DC
6V DC
9V DC
12V DC
46.7mA
31mA
23.3mA
15.5mA
11.7mA
64.2Ω
145Ω
257Ω
579Ω
1,028Ω
9.6mA
2,504Ω
230mW
120%V of
nominal voltage
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
1.5V DC
66.7mA
22.5Ω
3V DC
4.5V DC
6V DC
9V DC
12V DC
24V DC
33.3mA
22.2mA
16.7mA
11.1mA
8.3mA
5.0mA
90Ω
202.5Ω
360Ω
810Ω
1,440Ω
4,800Ω
100mW
150%V of
nominal voltage
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
24V DC
2) 1 coil latching type
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
120mW
*Pulse drive (JIS C 5442-1996)
ASCTB13E 201209-T
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
GN (AGN)
3) High sensitivity single side stable type
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
1.5V DC
66.7mA
22.5Ω
3V DC
4.5V DC
6V DC
33.3mA
22.2mA
16.7mA
90Ω
202.5Ω
360Ω
11.1mA
8.3mA
810Ω
1,440Ω
5.0mA
4,800Ω
Nominal coil
voltage
9V DC
12V DC
Set voltage
(at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
24V DC
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
100mW
150%V of
nominal voltage
120mW
120%V of
nominal voltage
*Pulse drive (JIS C 5442-1996)
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Single side stable
Nominal operating
High sensitivity single side
power
stable type
1 coil latching
Specifications
2 Form C
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Stationary contact: AgPd+Au clad Movable contact: AgPd
1 A 30 V DC, 0.3 A 125 V AC (resistive load)
30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
1A
10µA 10 mV DC
140mW (1.5 to 12 V DC), 230mW (24 V DC)
100mW (1.5 to 12 V DC), 120mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
2,500 V (2×10µs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce
time.) (without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10µs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 5 × 107 (at 180 cpm)
Min. 105 (1 A 30 V DC resistive), 105 (0.3 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C –40°F to +185°F
(High sensitivity single side stable type) –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g .035 oz
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Electrical
characteristics
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Mechanical
characteristics
Expected life
Conditions
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Shock resistance
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Unit weight
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to 6. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24).
REFERENCE DATA
1. Max. switching capacity
2. Life curve
3. Mechanical life
Tested sample: AGN2004H, 15 pcs.
Operating speed: 180 cpm
1.0
0.3
4
3.5
Pick-up voltage
Max.
50
40
3
30
DC 30V resistive load
20
Voltage, V
DC resistive load
AC resistive load
No. of operations, × 104
Switching current, A
100
Min.
2.5
2
Drop-out voltage
Max.
1.5
Min.
AC 125V
resistive load
10
1
0.5
30
100
Contact voltage, V
Panasonic Corporation
0
0.2
0.4
0.6
0.8
1.0
1.2
0
0
Switching current, A
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
10
30
50
No. of operations, ×104
ASCTB13E 201209-T
GN (AGN)
4. Electrical life (1A 30V DC resistive load)
5. Coil temperature rise
Tested sample: AGN2004H, 6 pcs.
Operating speed: 20 cpm
Tested sample: AGN2004H, AGN20024, 6 pcs.
Point measured: Inside the coil
Ambient temperature: Room temperature
Change of contact resistance
100
90
90
80
Pick-up voltage
70
Max.
Min.
60
50
Drop-out voltage
40
Max.
30
80
70
60
50
X
X
40
30
Min.
20
70
N.C. contact
N.O. contact
Temperature rise, °C
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
1A
0A
40
1A
0A
30
20
10
10
5
50
20
10
0
0
4.5V DC type
24V DC type
60
0
0
10
5
0
10
100
110
No. of operations, ×104
No. of operations, ×104
120
130
140
150
Coil applied voltage, %
6-(1). Operate and release time (without diode)
6-(2). Operate and release time (with diode)
7. Ambient temperature characteristics
Tested sample: AGN2004H, 6 pcs.
Tested sample: AGN2004H, 6 pcs.
Tested sample: AGN2004H, 6 pcs.
2.5
Max.
2
Min.
1.5
1
Max.
Min.
Operate time
Release time
2.5
Max.
Drop-out
voltage
-40 -20
0
2
Min.
Max.
1.5
Min.
Pick-up
voltage
1
0.5
0.5
0
0
50
Rate of change, %V
3
Operate time
Release time
Operate and release time, ms
Operate and release time, ms
3
40
30
20
x
x
10
60
80 100
20 40
-10
Ambient temperature, °C
-20
-30
-40
80
90
100
110
120
80
90
Coil applied voltage, %V
100
110
-50
120
Coil applied voltage, %V
9-(1). Influence of adjacent mounting
9-(2). Influence of adjacent mounting
Tested sample: AGN2004H
Tested sample: AGN20012, 6 pcs.
Tested sample: AGN20012, 6 pcs.
1,000m/s
Deenergized condition
Energized condition
X
1,000m/s2
Z
1,000m/s2
1,000m/s2
Z'
1,000m/s2
X'
1,000m/s2
Y'
10
5
ON
ON
Pick-up voltage
0
-5
ON
-10
10
OFF
5
OFF
Drop-out voltage
0
OFF
-5
-10
0
DIMENSIONS (mm inch)
Rate of change, %V
Y
2
Rate of change, %V
Z X X'
Rate of change, %V
Z'
Y
Y'
Rate of change, %V
8. Malfunctional shock
CAD Data
5
ON
Pick-up voltage
0
ON
-5
ON
-10
10
OFF
5
Drop-out voltage
0
OFF
-5
-10
0
2
4
6
8 10 12
.079 .157 .236 .315 .394 .472
Inter-relay distance , mm inch
The CAD data of the products with a
10
OFF
2
4
6
8 10 12
.079 .157 .236 .315 .394 .472
Inter-relay distance , mm inch
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. PC board terminal
External dimensions
CAD Data
PC board pattern
Schematic (Bottom view)
Standard type
7.60
.299
5.70±0.3
.224±.012
10.60±0.3
.417±.012
3.20
.126
3.20
.126
(0.50) 9.00±0.3
(.020) .354±.012
0.40±0.1
.016±.004
(1.50)
(.059)
ASCTB13E 201209-T
3.50±0.3
.138±.012
2.20±0.15
.087±.006
3.20±0.15
.126±.006
Panasonic Corporation
0.25±0.1
.010±.004
3.20±0.15
.126±.006
0.85 dia.
.033 dia.
2.20
.087
Tolerance: ±0.1 ±.004
Automation Controls Business Unit
Single side stable
High sensitivity
single side stable
1
2 3 4
8
7 6 5
1 coil latching
1
2 3 4
8
7 6 5
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
industrial.panasonic.com/ac/e/
GN (AGN)
2. Surface-mount terminal
CAD Data
Suggested mounting pad (Tolerance: ±0.1 ±.004)
Single side stable/1 coil latching/High sensitivity single side stable
External dimensions
Single side stable/1 coil latching/High sensitivity single side stable
Type
5.70±0.3
.224±.012
10.60±0.3
.417±.012
(0.50) 9.00±0.3
(.020) .354±.012 Max. 10.00
.394
0.25±0.1
.010±.004
A type
0.40±0.1
.016±.004
(1.50)
(.059)
0.80
.031
5.70±0.3
.224±.012
2.25
.089
3.20±0.15
.126±.006
2.20±0.15
.087±.006
3.20±0.15
.126±.006
0.40±0.1
.016±.004
(1.50)
(.059)
2.20
.087
3.20
.126
(0.50) 9.00±0.3
(.020) .354±.012 Max. 10.00
.394
0.25±0.1
.010±.004
5.30
.209
7.40±0.3
.291±.012
10.60±0.3
.417±.012
S type
3.10
.122
3.20±0.15
.126±.006
2.20±0.15
.087±.006
3.20±0.15
.126±.006
2.20
.087
3.20
.126
4.45
.175
0.80
.031
5.70±0.3
.224±.012
Schematic (Top view)
Single side stable
High sensitivity single side stable
8
7 6 5
1
2 3 4
1 coil latching
8
7 6 5
1
2 3 4
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
1.50 +0.1
0 dia.
.059 +.004
dia.
0
2.00
.079
4.00 2.0 dia.
.157 .079 dia.
1.75
.069
Orientation (indicates PIN No.1)stripe
10.70±0.2
.421±.008
0.40
.016
11.50
.453 24.00±0.3
.945±.012
11.10
.437
GN relays
16.00
.630
6.3
.248
Tape coming out direction
General tolerance ±0.1 mm .004 inch
Stopper (green)
Stopper (red)
(2) Dimensions of plastic peel
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
mm inch
mm inch
Relay polarity bar
(Z type)
0.40
.016
4.00
.157
2.00
.079
1.50 +0.1
0 dia.
dia.
.059 +.004
0
11.50
.453
1.75
.069
11.10
.437
10.70±0.2
.421±.008
GN relays
2.00 dia.
.079 dia.
16.00
.630
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
A
C
B
2.0
.079
13 dia.
.512 dia.
21 dia.
.827 dia.
24.00±0.3
.945±.012
8.00
.315
Tape coming out direction
General tolerance ±0.1 mm .004 inch
380 dia.
14.961 dia.
80 dia.
3.150 dia.
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
Panasonic Corporation
Automation Controls Business Unit
industrial.panasonic.com/ac/e/
ASCTB13E 201209-T