MPD MPM40S12E Mpm-40e sery Datasheet

MPM-40E Series
Low Cost, Encapsulated
Single Output, 40W
AC/DC Power Supplies
Key Features:
Electrical Specifications
• 40W Output Power
• Universal 85-264 VAC Input
• EN 60950 Approved (UL)
• Meets IEC Safety Class II
• Industry Standard Pin-Out
• Meets EN 55022 Class B
• >200 kHour MTBF
• Low Cost
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Conditions
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
30.0
230 VAC
50.0
Max.
264
370
440
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
Max.
Units
0.5
W
%
%
%
mV P-P
Input Voltage Range
Input Frequency
Input Current
Inrush Current
Units
VAC
VDC
Hz
A Pk
Output
Parameter
Output Voltage
Output Current
Standby Power
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
±2.0
VIN = Min to Max
±0.5
See Note 2
±1.0
50
115 VAC
15
230 VAC
80
±0.02
Continuous (Autorecovery)
Zener Diode Clamp
Autorecovery 110
Hold-Up Time
Temperature Coefficient
Short Circuit Protection
Over Voltage Protection
Overload Protection
100
mSec
%/°C
%W
General
Parameter
Isolation Voltage
Isolation Resistance
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Voltage Dips
Switching Frequency
Conditions
60 Sec
500 VDC
Standard
See Note 4
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
Min.
3,000
100
Typ.
Min.
Typ.
Min.
-40
Typ.
+25
Max.
Units
VAC
M
Max.
Units
Class B
Class B
Criteria B; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±1 kV/ ±2 kV
Criteria A; 10 Vrms
Criteria A; 10A/m
Criteria B; 95% 5000 mS
65
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Max.
+70
+90
-40
+85
Free Air Convection (See Derating Curve)
RH, Non-condensing
95
Ambient
Case
Units
°C
°C
°C
%
Physical
Case Size
Case Material
Weight
3.50 x 2.50 x 0.984 Inches (89.0 x 63.5 x 25.0 mm)
Non-Conductive Black Plastic (UL94-V0)
8.8 Oz (250g)
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign
200
EN 60950
IEC 61140 Class II
www.micropowerdirect.com
Max.
Units
kHours
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MPM-40S-03E
MPM-40S-05E
MPM-40S-09E
MPM-40S-12E
MPM-40S-15E
MPM-40S-24E
Current (A)
115 VAC 230 VAC
0.860
0.460
0.860
0.460
0.860
0.460
0.860
0.460
0.860
0.460
0.860
0.460
Typical Connection
Output
Capacitive Efficiency
Load
Voltage Current Current
(%, Typ)
(µF Max.)
(VDC)
(A Max.)
(% Min.)
3.3
5.0
9.0
12.0
15.0
24.0
8.000
8.000
4.444
3.333
2.666
1.666
10
10
10
10
10
10
60,000
40,000
7,200
9,000
6,600
2,000
78
82
84
84
84
84
Notes:
1. Operation at no load will not damage the units, however, they may not
meet all specifications.
2. Load regulation is measured for an output change of 10% to 100% at
nominal input line.
3. All units are rated for EN 55022 (CE/RE) class B without external components.
4. All units are rated for EN 61000-4-4 (±2 kV) and EN 61000-4-5 (±1k/±2 kV)
without external components. They will meet EN 61000-4-5 (±2 kV/ ±4 kV)
with additional input filtering as shown below.
5. It is recommended that a fuse be used on the input of a power supply for
protection. For the MPM-40S-xxE series, a 3.15A/250 VAC slow blow
should be used.
The diagram below illustrates a typical application connection of the MPM-40S-xxE series. Notes on this circuit (starting with the input circuit) are:
1. It is recommended that an external fuse and NTC be used. The recommended
fuse is a 3.15A/250V slow blow and for the NTC, a 5D-9.
2. An external MOV is required on the input to protect the unit in the event of a
surge. A 561KD20 or equivalent is recommended.
3. Recommended output filtering capacitors are:
C1
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
1.0 µF/50V
MPM-40S-03E
MPM-40S-05E
MPM-40S-09E
MPM-40S-12E
MPM-40S-15E
MPM-40S-24E
Typical Board Layout: With EMI Components (See note 4)
C2
680 µF/10V
680 µF/10V
220 µF/25V
220 µF/25V
220 µF/25V
120 µF/35V
TVS
SMBJ7.0A
SMBJ7.0A
SMBJ12A
SMBJ20A
SMBJ20A
SMBJ30A
The output filtering capacitor (C2) is a high frequency, low resistance electrolytic
capacitor. Capacitor (C1) is ceramic. Voltage derating of capacitors should be
80% or above.
4. Input noise and surge suppression components are illustrated in the typical
board layout at left. Modules are available for a number of MPD AC/DC power
supplies that contain these components. For pricing or full technical information
on these modules (ACFM-01 and ACFM-02) or suggested EMI circuits , please
contact the factory.
Pin Connections
Derating Curve
Pin
Function
Pin
Function
1
2
3
AC-Line
AC-Neutral
+VOUT
5
7
-VOUT
Trim
Mechanical Dimensions
Input Voltage Vs Load
MicroPower Direct
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]