Crane MGH2812S/883 Mch/mgh single and dual dc/dc converter Datasheet

Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
FEATURES
•
•
•
•
•
•
•
•
•
•
•
MODELS
-55°C to +125°C operation
12 to 50 VDC input
Fully isolated
Magnetic feedback
Fixed frequency 370 kHz typ.
Topology – Current Mode Flyback
80 V for up to 120 ms transient protection
(70 V for 15 V single and dual models)
Inhibit function
Indefinite short circuit protection
Undervoltage lockout
Up to 79% efficiency (MGH models)
VDC OUTPUT
SINGLES
5
5.2 (MCH)
12
15
MCH SERIES™ SINGLE & DUAL
DC/DC CONVERTERS
With a miniature footprint of just 0.8 square inches, the MCH
Series™ of DC/DC converters delivers 1.5 watts of output power
while saving significant board real estate. The wide input voltage
range of 12 to 50 VDC accepts the varying voltages of military, aerospace, or space bus power and tightly regulates output voltages to
protect downstream components. Transient protection of 80 volts for
up to 120 milliseconds exceeds the requirements of MIL-STD-704A
for the 5, 5.2, and 12 volt single models and the 12 volt dual model.
The 15 volt single and dual converters will withstand transients of up
to 70 volts for up to 120 milliseconds.
CONVERTER DESIGN
MCH Series DC/DC converters incorporate a continuous flyback
topology with a constant switching frequency of approximately 370
kHz. Current-mode pulse width modulation (PWM) provides output
voltage regulation. Output error voltage is magnetically fed back to
the input side of the PWM to regulate output voltage. Regulation is
also affected by the load; refer to the Electrical Characteristics
tables on the following pages.
Dual models regulate the negative output with magnetic coupling to
the positive output. Up to 80% of the total load may be on one output
providing that the other output carries a minimum of 20% of the total
load. The dual models can be used at double the output voltage by
connecting the load between positive and negative outputs, leaving
the common unconnected. (ex: MCH2805D can be used as a 10
VDC output.)
Crane Aerospace & Electronics
Electronics Group (Interpoint Brand)
PO Box 97005 • Redmond WA 98073-9705
425.882.3100 • [email protected]
www.craneae.com
DUALS
±5
±12
±15
INHIBIT FUNCTION
When an open collector TTL logic low is applied to the inhibit
terminal, pin 7, the converter shuts down and lowers the output
voltage to near zero and input current to as low as 2.3 mA. Leaving
the terminal open or applying an open collector TTL logic high will
enable the converter.
PROTECTION FEATURES
Undervoltage lockout prevents the MCH Series converters from
operating below approximately 8 VDC input voltage to keep system
current levels smooth, especially during initialization or re-start operations. All models include a soft-start function to prevent large
current draw and minimize overshoot. The converters also provide
short circuit protection by restricting the current.
MIL-STD-461
Use Interpoint’s FMSA-461 EMI filter to pass the CE03 requirements
of MIL-STD-461C.
CONVENIENT PACKAGING
The MCH Series converters are packaged in hermetically sealed,
projection-welded metal cases which provide EMI/RFI shielding.
Page 1 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
MGH SERIES™ SINGLE & DUAL
DC/DC CONVERTERS
PROTECTION FEATURES
The MGH Series™ of DC/DC converters delivers 1.5 watts of output
power in a labor saving surface mount package. The wide input
voltage range of 12 to 50 VDC accepts the varying voltages of military, aerospace, or space applications. Single output converters
feature outputs of 5, 12, or 15 volts while dual output models feature
outputs of ±5, ±12, or ±15 volts. Transient protection of 80 volts for
up to 120 milliseconds exceeds the requirements of MIL-STD-704A
for the 5 and 12 volt single and dual models. The 15 volt single and
dual converters will withstand transients of up to 70 volts for up to
120 milliseconds.
Undervoltage lockout prevents the MGH Series converters from
operating below approximately 8 VDC input voltage to keep system
current levels smooth, especially during initialization or re-start operations. All models include a soft-start function to prevent large
current draw and minimize overshoot. The MGH Series of converters
also provide short circuit protection by limiting the current to approximately 125% of full load.
MIL-STD-461
Use Interpoint’s FMGA-461 EMI filter to pass the CE03 requirements
of MIL-STD-461C.
CONVERTER DESIGN
MGH Series DC/DC converters incorporate a continuous flyback
topology with a constant switching frequency of approximately 370
kHz. Output voltage regulation is accomplished on the primary side
using current-mode pulse width modulation (PWM). Regulation is
affected by the output load; refer to the specifications tables for more
information.
SURFACE MOUNT PACKAGE
MGH DC/DC converters can be surface mounted with pick-andplace equipment or manually. It is recommended that the case be
attached with flexible epoxy adhesive or silicone which is thermally
conductive (>1 watt /meter/°K).
For dual output models, up to 80% of the total load may be on one
output providing the other output carries a minimum of 20% of the
total load. The dual models can be used at double the output voltage
by connecting the load between positive and negative outputs,
leaving the common unconnected. As an example the MGH2805D (5
volt dual output) can be used as a 10 VDC output.
Internal components are soldered with SN96 (melting temperature
221°C) to prevent damage during reflow. Maximum reflow temperature for surface mounting the MGH converter is 220°C for a
maximum of 30 seconds. SN60, 62, or 63 are the recommended
types of solder. Hand soldering should not exceed 300°C for 10
seconds per pin.
INHIBIT FUNCTION
The hermetically sealed metal cases are available in two different
lead configurations. See case B for dimensions and options.
When an open collector TTL logic low is applied to the inhibit
terminal, pin 18, the converter shuts down and lowers the output
voltage to near zero and input current to as low 2.3 mA. Leaving the
terminal open or applying an open collector TTL logic high will enable
the converter.
Positive
Input
+
+Vin
Inhibit
Shutdown
PWM
Controller
Positive
Output
+
Output
Common
+Vout
Input
Common
Case
Ground
Dual models only
FIGURE 1: MGH BLOCK DIAGRAM
www.craneae.com
+
FB
Page 2 of 18
Rev E - 20060508
Negative
Output
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
OPERATING CONDITIONS AND CHARACTERISTICS
INHIBIT
Input Voltage Range
• 12 to 50 VDC continuous
• 80 V for 120 msec transient
(70 V for 15 V single and dual models)
Output Power
• 1.5 W
Capacitive Load
• 200 μF single output models
• 100 μF each output, dual output models
Lead Soldering Temperature
• Reflow 220°C 30 sec. max
SN60, 62 or 63 recommended solder
• Hand solder 300°C 10 sec. max per lead
Storage Temperature Range (Case)
• –65°C to +150°C
Case Operating Temperature (Tc)
• –55°C to +125°C full power
• –55°C to +135°C absolute
Derating Output Power/Current (Tc)
• Linearly from 100% at 125°C to 0% at 135°C
Output Voltage Temperature Coefficient
• 100 ppm/°C typical
Input to Output Capacitance
• 100 to 170 pF typical
Current Limit
• 125% of full load typical
Isolation
• 100 megohm minimum at 500 V
Audio Rejection
• 40 dB typical
Conversion Frequency (kHz)
• 25°C
300 min, 370 typ, 450 max
• –55°C to +125°C
270 min, 370 typ, 470 max
Inhibit Pin Voltage (unit enabled)
• 7 to 12 V
Undervoltage Lockout
• 8 V input typical
Inhibit – TTL Open Collector
• Logic low (output disabled)
Logic low voltage ≤0.8 V
Inhibit pin current 1 mA max
• Referenced to input common
• Logic high (output enabled) open collector
MECHANICAL AND ENVIRONMENTAL
Size (maximum)
MCH models 0.980 x 0.805 x 0.270 inches (24.89 x 20.45 x 6.86 mm)
See case A2 for dimensions.
MGH models 1.010 x 0.880 x 0.250 inches (25.65 x 22.35 x 6.35 mm)
Shown on page one with “gull wing” lead option, also available with
straight leads. See case B for dimensions and options.
Weight (maximum)
12 grams typical
Screening
Standard, ES, or 883 (Class H, QML). See “883, Class H, QML Products –
Element Evaluation” and “883, Class H, QML Products – Environmental
Screening” for more information.
POSITIVE 1
INPUT
+
0.47 μF
typical
FB
+VIN
+
INHIBIT
7
SHUTDOWN
PWM
CONTROLLER
+VOUT
+
INPUT
COMMON
2
4 OUTPUT
COMMON
6 NEGATIVE
OUTPUT
DUAL MODELS ONLY
FIGURE 2: MCH BLOCK DIAGRAM
www.craneae.com
3 POSITIVE
OUTPUT
Page 3 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Squared corner and dot on
PIN OUT MCH MODELS
Pin
1
2
3
4
5
6
7
Single Output
Positive Input
Input Common
Positive Output
Output Common
Case Ground
No connection
Inhibit
top of cover indicate pin one.
Dual Output
Positive Input
Input Common
Positive Output
Output Common
Case Ground
Negative Output
Inhibit
1 2
7
3
4
6
5
See case A2 for dimensions.
FIGURE 3: MCH PIN OUT
PINS NOT IN USE
Inhibit (INH1, INH2)
Pin 2, 12, 15, 16, 17
(pins with no connection)
Leave unconnected
Ground to input common
PIN OUT MGH MODELS
Pin
1
2
3
4, 5
6, 7
8, 9
10, 11
12
13, 14
15, 16, 17
18
Single Output
Positive Input
No connection
Input Common
Positive Output
Case Ground
Output Common
Case Ground
No connection
No connection
No connection
Inhibit
Dual Output
Positive Input
No connection
Input Common
Positive Output
Case Ground
Output Common
Case Ground
No connection
Negative Output
No connection
Inhibit
1
2
3
4
5
6
7
8
9
Differently colored glass bead around pin one or dimple in
header (bottom or side of case) indicates pin one.
Cover marking is oriented with pin one at the upper right corner.
See case B for dimensions and “gull-wing” option.
FIGURE 4: MGH PIN OUT
To meet specified performance, all pins must
be connected except “No Connection” pins.
www.craneae.com
TOP VIEW
MGH
18
17
16
15
14
13
12
11
10
Page 4 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
MCH Model Selection Table (see next page for MGH options)
SMD NUMBERS
MODEL NUMBERING KEY
MCH
STANDARD MICROCIRCUIT
DRAWING (SMD)
28 12 D / 883
Base Model
Input Voltage
5962-9569601HXC
5962-9569701HXC
5962-9569801HXC
5962-9570201HXC
5962-9570301HXC
5962-9570401HXC
Output Voltage
(R = decimal point, 3R3 = 3.3 Vout)
Number of Outputs
(S = single, D = dual)
Screening
(Standard screening has no designator
in this position.)
MCH SERIES
SIMILAR PART
MCH2805S/883
MCH2812S/883
MCH2815S/883
MCH2805D/883
MCH2812D/883
MCH2815D/883
For exact specifications for an SMD product, refer to the SMD
drawing. SMDs can be downloaded from:
http://www.dscc.dla.mil/programs/smcr
Model Selection
MCH28
Base model
Vout value
number of outputs
case option
screening
Choose one from each of the following rows
Vout value
for singles: 5, 5R2, 12, 15
duals: 5, 12, 15
“R” = decimal point, 3R3 = 3.3 VDC
Number of outputs
S (single) or D (dual)
Case option
standard (case A2, leave blank)
Screening
standard screening, leave blank
www.craneae.com
Page 5 of 18
Rev E - 20060508
/ES (ES screening), /883 (Class H, QML)
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
MGH Model Selection Table (see previous page for MCH options)
MODEL NUMBERING KEY
MGH
SMD NUMBERS
28 12 S
STANDARD MICROCIRCUIT
DRAWING (SMD)
Z / ES
Base Model
Input Voltage
MGH2805S/883
MGH2812S/883
MGH2815S/883
MGH2805D/883
MGH2812D/883
MGH2815D/883
5962-9569601HYC
5962-9569701HYC
5962-9569801HYC
5962-9570201HYC
5962-9570301HYC
5962-9570401HYC
Output Voltage
Number of Outputs
(S = single, D = dual)
Gull Wing Lead Option
(Straight leaded case has no designator
in this position.)
MCH/MGH SERIES
SIMILAR PART
For exact specifications for an SMD product, refer to the SMD
drawing. For the gull wing lead option, replace the Y in the SMD
number (HYC) with a Z (HZC). SMDs can be downloaded from
http://www.dscccols.com/programs/smcr
Screening
(Standard screening has no designator
in this position.)
Model Selection
MGH28
Base model
Vout value
number of outputs
screening
Choose one from each of the following rows
Vout value
singles: 5, 12, 15
duals: 5, 12, 15
“R” = decimal point, 3R3 = 3.3 VDC
Number of outputs
S (single) or D (dual)
Screening
standard screening, leave blank
www.craneae.com
Page 6 of 18
Rev E - 20060508
/ES (ES screening), /883 (Class H, QML)
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MCH SINGLE OUTPUT MODELS
PARAMETER
CONDITIONS
OUTPUT VOLTAGE2
Tc = 25°C
Tc = –55°C TO +125°C
OUTPUT CURRENT
V = 12 to 50 VDC
MCH2805S
MCH2812S
MCH2815S
MIN TYP MAX MIN TYP MAX MIN TYP MAX
4.95
5
5.05 11.88 12 12.12 14.85 15 15.15
4.80
5
5.20 11.52 12 12.48 14.40 15 15.60
—
—
300
—
—
125
—
—
100
IN
OUTPUT POWER
V
IN
OUTPUT RIPPLE
VOLTAGE
LINE REGULATION
LOAD REGULATION
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
INPUT RIPPLE
CURRENT3
EFFICIENCY
LOAD FAULT
4,5
STEP LOAD
RESPONSE6
STEP LINE
RESPONSE6
START-UP
CAPACITIVE LOAD
= 12 TO 50 VDC
10 kHz - 2 MHz
Tc = –55°C TO +125°C
V = 12 TO 50 VDC
IN
Tc = –55°C TO +125°C
10% TO FULL LOAD
Tc = –55°C TO +125°C
50% TO FULL1
Tc = –55°C TO +125°C
CONTINUOUS
TRANSIENT1 120 ms
NO LOAD
Tc = –55°C TO +125°C
INHIBITED
Tc = –55°C TO +125°C
10k Hz - 10 MHz
Tc = –55°C TO +125°C
Tc = 25°C
Tc = –55°C TO +125°C
POWER DISSIPATION
Tc = –55°C TO +125°C
RECOVERY1
Tc = -–55°C TO +125°C
50 %–100%– 50% LOAD
TRANSIENT
Tc = –55°C TO +125°C
RECOVERY
Tc =–55°C TO +125°C
12 TO 50 TO 12 V
IN
TRANSIENT1
Tc = –55°C TO +125°C
RECOVERY1
Tc = –55°C TO +125°C
DELAY
Tc = –55°C TO +125°C
OVERSHOOT1
Tc = –55°C TO +125°C
0
—
1.5
0
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
72
69
—
—
—
—
45
65
35
40
350
380
100
115
28
—
5.5
6.0
2.3
2.4
100
130
77
75
1.3
1.4
3.0
3.5
150
300
120
120
800
800
200
300
50
80
11
11
3.5
3.5
200
250
—
—
2.0
2.3
15
15
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
74
72
—
—
—
—
–500
–500
—
—
185
185
125
125
500
500
500
600
–700
–800
—
—
–500
–500
—
—
—
—
—
—
170
180
0.75
0.75
7
10
0
0
1.5
0
—
1.5
—
—
—
—
—
—
—
—
12
0
—
—
—
—
—
—
74
72
—
—
—
—
35
50
70
80
700
760
165
185
28
—
6.0
6.5
2.3
2.4
100
150
79
77
2.3
2.5
4.0
4.0
150
250
350
350
1600
1600
350
450
50
70
12
12
3.5
3.5
200
250
—
—
3.7
4.0
20
20
–700
–800
—
—
350
380
140
180
700
800
600
750
500 –1000 400 1000 –850 400
500 –1000 400 1000 –850 450
4.0
—
0.6
3.0
— 0.47
4.0
—
0.6
3.0
—
0.5
40
—
7
40
—
7
40
—
10
40
—
10
150
—
0
350
—
0
150
—
0
350
—
0
850
850
2.5
2.5
40
40
450
450
50
200
70
300
60
250
70
250
600 1400
640 1400
145 300
160 400
28
50
—
80
6.0
12
6.5
12
2.3
3.5
2.4
3.5
100 200
150 250
79
—
77
—
2.0
3.2
2.2
3.5
3.5
20
3.5
20
350
380
130
130
700
800
500
600
VDC
mA
W
mV p-p
mV
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
μs
mV pk
ms
ms
mV pk
1
Notes:
1. Guaranteed by design, not tested.
2. Specified at 50% total P .
out
3. Lin = 2 μH.
4. Maximum duration of short circuit: 25°C-– 90 seconds, 125°C – 30 seconds.
5. Load fault is a short circuit (<50 mohms). Recovery is into resistive full load.
www.craneae.com
—
UNITS
6. Transition ≥ 10 μs. Recovery = time to settle to within 1% of Vout final value.
7. Max. spec indicates 80% of the converter’s total power, available from either
output.
Page 7 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MGH SINGLE OUTPUT MODELS
PARAMETER
1
OUTPUT VOLTAGE
MGH2805S
CONDITIONS
Tc = 25°C
Tc = –55°C TO +125°C
MGH2812S
MGH2815S
MIN
4.95
4.80
TYP
5
5
MAX
5.05
5.20
MIN
11.88
11.52
TYP
12
12
MAX
12.12
12.48
MIN
14.85
14.40
TYP
15
15
MAX
15.15
15.60
UNITS
VDC
OUTPUT CURRENT
V
= 12 to 50 VDC
0
—
300
0
—
125
0
—
100
mA
OUTPUT POWER
VIN = 12 to 50 VDC
0
—
1.5
0
—
1.5
0
—
1.5
W
OUTPUT RIPPLE
VOLTAGE
10 kHz - 2 MHz
Tc = –55°C TO +125°C
—
—
45
65
150
300
—
—
50
70
200
300
—
—
35
50
150
250
mV p-p
LINE REGULATION
VIN = 12 to 50 VDC
Tc = –55°C TO +125°C
—
—
35
40
100
120
—
—
60
70
200
250
—
—
70
80
300
350
mV
LOAD REGULATION
10% TO FULL LOAD
Tc = –55°C TO +125°C
—
—
350
380
700
800
—
—
600
640
1300
1400
—
—
700
760
1500
1600
50% TO FULL LOAD
Tc = –55°C TO +125°C
—
—
100
115
200
300
—
—
145
160
300
400
—
—
165
185
350
450
CONTINUOUS
TRANSIENT 120 ms
12
0
28
—
50
80
12
0
28
—
50
80
12
0
28
—
50
70
NO LOAD
Tc = –55°C TO +125°C
—
—
5.5
6.0
10
11
—
—
6.0
6.5
10
12
—
—
6.0
6.5
11
12
FULL LOAD
Tc = –55°C TO +125°C
—
—
70
73
74
78
—
—
68
70
72
74
—
—
68
70
72
74
INHIBITED
Tc = –55°C TO +125°C
—
—
2.3
2.4
3.2
3.5
—
—
2.3
2.4
3.2
3.5
—
—
2.3
2.4
3.2
3.5
INPUT RIPPLE
2
CURRENT
10k Hz - 10 MHz
Tc = –55°C TO +125°C
—
—
100
130
200
250
—
—
100
150
200
250
—
—
100
150
200
250
mA p-p
EFFICIENCY
Tc = 25°C
Tc = –55°C TO +125°C
72
69
77
75
—
—
74
72
79
77
—
—
74
72
79
77
—
—
%
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
LOAD FAULT
3, 4
IN
POWER DISSIPATION
—
1.3
2.0
—
2.0
3.2
—
2.3
3.7
Tc = –55°C TO +125°C
—
1.4
2.3
—
2.2
3.5
—
2.5
4.0
RECOVERY
Tc = -–55°C TO +125°C
TRANSIENT
Tc = –55°C TO +125°C
—
—
–400
–500
3.0
3.5
185
185
12
15
400
500
—
—
–700
–800
3.5
3.5
350
380
15
20
700
800
—
—
–700
–800
4.0
4.0
350
380
18
20
700
800
RECOVERY
Tc = –55°C TO +125°C
TRANSIENT
Tc = –55°C TO +125°C
—
—
–400
–500
125
125
170
180
500
600
400
500
—
—
–900
–1000
130
130
400
400
500
600
900
1000
—
—
–750
–850
140
180
400
450
600
750
750
850
12 TO 50 TO 12 VIN
RECOVERY
Tc = –55°C TO +125°C
—
—
0.75
0.75
3.0
4.0
—
—
0.6
0.6
2.5
3.0
—
—
0.47
0.5
2.0
2.5
START-UP
0 TO 28 VDC
DELAY
Tc = –55°C TO +125°C
OVERSHOOT
Tc = –55°C TO +1 25°C
—
—
—
—
7
10
0
0
20
40
100
150
—
—
—
—
7
10
0
0
20
40
250
350
—
—
—
—
7
10
0
0
20
40
300
450
STEP LOAD
RESPONSE5
50 %–100%– 50%
STEP LINE
RESPONSE5
Notes
1. Specified at 50% of full load.
2. Lin = 2 μH
3. Max. duration of short circuit: 25°C– 90 seconds; 125°C – 30 seconds.
www.craneae.com
mV
VDC
V
mA
W
ms
mV pk
μs
mV pk
ms
ms
mV pk
4. Load fault is a short circuit (<50 mohms). Recovery into resistive full load.
5. Input step transition ≥ 10 μs.Recovery is time to settle to within 1% of Vout
final value.
Page 8 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MCH DUAL OUTPUT MODELS
PARAMETER
CONDITIONS
2
Tc = 25°C
OUTPUT VOLTAGE
Tc = –55°C TO +125°C
OUTPUT CURRENT7
V = 12 TO 50 VDC
IN
OUTPUT POWER
V
MCH2812D
MCH2815D
MIN TYP MAX
MIN TYP MAX
±11.88 ±12 ±12.12 ±14.85 ±15 ±15.15
±11.52 ±12 ±12.48 ±14.40 ±15 ±15.60
0
±62.5 100
0
±50
80
0
—
1.5
0
—
1.5
0
—
1.5
OUTPUT RIPPLE
VOLTAGE +V
10 kHz - 2 MHz
Tc = –55°C TO +125°C
—
—
35
50
150
250
—
—
35
40
150
250
—
—
30
35
150
250
–V
10 kHz - 2 MHz
Tc = –55°C TO +125°C
V = 12 TO 50 VDC
IN
Tc = –55°C TO +125°C
10% TO FULL
–55°C TO +125°C
—
—
—
—
—
—
35
50
10
20
300
350
150
250
50
100
600
700
—
—
—
—
—
—
35
40
100
110
550
570
150
250
300
400
1100
1200
—
—
—
—
—
—
30
35
165
180
600
630
150
250
500
650
1300
1400
50% TO FULL1
–55°C TO +125°C
CONTINUOUS
TRANSIENT1 120 ms
NO LOAD
Tc = –55°C TO +125°C
INHIBITED
Tc = –55°C TO +125°C
10 kHz - 10 MHz
Tc = –55°C TO +125°C
Tc = 25°C
Tc = –55°C TO +125°C
—
—
12
0
—
—
—
—
—
—
73
70
80
100
28
—
5.0
6.0
2.3
2.4
100
130
77
75
200
300
50
80
10
12
3.2
3.5
200
250
—
—
—
—
12
0
—
—
—
—
—
—
73
70
115
130
28
—
7.5
8.0
2.3
2.4
115
150
77
75
250
350
50
80
13
14
3.2
3.5
200
250
—
—
—
—
12
0
—
—
—
—
—
—
72
69
125
135
28
—
7.5
8.0
2.3
2.4
90
120
76
74
300
400
50
70
13
14
3.2
3.5
200
250
—
—
—
—
—
—
1.4
1.6
3.7
3.8
2.2
2.5
15
20
—
—
—
—
2.5
2.7
3.2
3.2
3.8
4.2
15
20
—
—
—
—
2.7
3.0
4.0
4.0
4.1
4.5
15
20
–300
–400
—
—
130
140
100
100
300
400
400
500
–600
–700
—
—
250
260
165
165
600
700
700
800
–600
–700
—
—
250
270
50
50
600
700
200
300
–250
–300
—
—
—
—
125
130
0.6
0.6
8
10
250
300
2.5
3.0
25
45
–500
–600
—
—
—
—
240
250
0.9
0.9
8
10
500
600
3.0
4.0
25
45
–500
–600
—
—
—
—
220
230
0.6
0.7
8
10
500
600
3.0
4.0
25
45
—
—
0
0
100
150
—
—
0
0
250
350
—
—
0
0
750
900
IN
OUT
OUT
8
LINE REGULATION
9
LOAD REGULATION
±VOUT
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
INPUT RIPPLE
CURRENT
EFFICIENCY
3
= 12 TO 50 VDC
MCH2805D
MIN TYP MAX
±4.95 ±5
±5.05
±4.80 ±5
±5.20
0
±150
240
4,5
POWER DISSIPATION
Tc = –55°C TO +125°C
1
RECOVERY
Tc = –55°C TO +125°C
STEP LOAD
50 %–100%– 50% LOAD
6
TRANSIENT
RESPONSE ± VOUT
Tc = –55°C TO +125°C
RECOVERY
–55°C TO +125°C
STEP LINE
12 TO 50 TO 12 VIN
RESPONSE6 ± VOUT
TRANSIENT1
Tc = –55°C TO +125°C
1
RECOVERY
Tc = –55°C TO +125°C
START–UP
DELAY
0 TO 28 VDC, ± VOUT Tc = –55°C TO +125°C
LOAD FAULT
OVERSHOOT1
Tc = –55°C TO +125°C
CAPACITIVE LOAD
VDC
mA
W
mV p-p
mV
mV
VDC
V
uF
mA p-p
%
W
ms
mV pk
μs
mV pk
ms
ms
mV pk
uF
Notes:
1. Guaranteed by design, not tested.
2. Specified at 50% balanced load.
3. Lin = 2 μH.
4. Maximum duration of short circuit: 25°C-– 90 seconds, 125°C – 30 seconds.
5. Load fault is a short circuit (<50 mohms). Recovery is into resistive full load,
with one output shorted at a time.
www.craneae.com
UNITS
6. Transition ≥ 10 μs. Recovery = time to settle to within 1% of Vout final value.
7. Max. spec indicates 80% of the converter’s total power, available from either
output.
8. Specification applies to both + and – Vout.
9. Although no minimum load is required, at no load the output voltage may
increase up to 15%.
Page 9 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MGH DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE1
OUTPUT CURRENT
2
OUTPUT POWER
MGH2812D
MGH2815D
MIN
±4.95
±4.80
TYP
±5
±5
MAX
±5.05
±5.20
MIN
±11.88
±11.52
TYP
±12
±12
MAX
±12.12
±12.48
MIN
±14.85
±14.40
TYP
±15
±15
VIN = 12 to 50 VDC
0
±150
240
0
±62.5
100
0
V
0
—
1.5
0
—
1.5
0
—
35
150
—
35
150
—
IN
OUTPUT RIPPLE
MGH2805D
CONDITIONS
Tc = 25°C
Tc = –55°C TO +125°C
= 12 to 50 VDC
10 kHz - 2 MHz
MAX
±15.15
±15.60
UNITS
±50
80
mA
—
1.5
W
30
150
VDC
VOLTAGE +VOUT
Tc = –55°C TO +125°C
—
50
250
—
40
250
—
35
250
–VOUT
10 kHz - 2 MHz
Tc = –55°C TO +125°C
—
—
35
50
150
250
—
—
35
40
150
250
—
—
30
35
150
250
VIN = 12 to 50 VDC
Tc = –55°C TO +125°C
—
—
10
20
50
100
—
—
100
110
300
400
—
—
165
180
500
650
10% TO FULL LOAD
–55°C TO +125°C
—
—
300
350
600
700
—
—
550
570
1100
1200
—
—
600
630
1300
1400
50% TO FULL LOAD
–55°C TO +125°C
—
—
80
100
200
300
—
—
115
130
250
350
—
—
125
135
300
400
–VOUT
—
—
400
—
—
500
—
—
500
mV
CONTINUOUS
TRANSIENT 120 ms
12
0
28
—
50
80
12
0
28
—
50
80
12
0
28
—
50
70
VDC
V
NO LOAD
Tc = –55°C TO +125°C
—
—
5.0
6.0
10
12
—
—
7.5
8.0
13
14
—
—
7.5
8.0
13
14
FULL LOAD
Tc = –55°C TO +125°C
—
—
69
72
73
77
—
—
70
71
73
77
—
—
71
72
74
78
INHIBITED
Tc = –55°C TO +125°C
—
—
2.3
2.4
3.2
3.5
—
—
2.3
2.4
3.2
3.5
—
—
2.3
2.4
3.2
3.5
10 kHz - 10 MHz
Tc = –55°C TO +125°C
—
—
100
130
200
250
—
—
115
150
200
250
—
—
90
120
200
250
mA p-p
Tc = 25°C
Tc = –55°C TO +125°C
73
70
77
75
—
—
73
70
77
75
—
—
72
69
76
74
—
—
%
POWER DISSIPATION
Tc = –55°C TO +125°C
—
—
1.4
1.6
2.2
2.5
—
—
2.5
2.7
3.8
4.2
—
—
2.7
3.0
4.1
4.5
W
RECOVERY
Tc = –55°C TO +125°C
—
—
3.7
3.8
15
20
—
—
3.2
3.2
15
20
—
—
4.0
4.0
15
20
ms
TRANSIENT
Tc = –55°C TO +125°C
–300
–400
130
140
300
400
–600
–700
250
260
600
700
–600
–700
250
270
600
700
mV pk
RECOVERY
–55°C TO +125°C
—
—
100
100
400
500
—
—
165
165
700
800
—
—
50
50
200
300
μs
STEP LINE
RESPONSE19
TRANSIENT
Tc = –55°C TO +125°C
–250
–300
125
130
250
300
–500
–600
240
250
500
600
–500
–600
220
230
500
600
mV pk
± Vout
12 TO 50 TO 12 VIN
START–UP
0 TO 28 VDC, ± Vout
RECOVERY
Tc = –55°C TO +125°C
—
—
0.6
0.6
2.5
3.0
—
—
0.9
0.9
3.0
4.0
—
—
0.6
0.7
3.0
4.0
ms
DELAY
Tc = –55°C TO +125°C
—
—
8
10
25
45
—
—
8
10
25
45
—
—
8
10
25
45
ms
OVERSHOOT
Tc = –55°C TO +125°C
—
—
0
0
100
150
—
—
0
0
250
350
—
—
0
0
750
900
mV pk
3
LINE REGULATION
mV p-p
V
LOAD
3
REGULATION , 4
mV
CROSS
REGULATION5
INPUT VOLTAGE
NO LOAD TO FULL
INPUT CURRENT
INPUT RIPPLE
CURRENT
6
EFFICIENCY
LOAD FAULT
7,8
STEP LOAD
RESPONSE 9
± Vout
50 %–100%– 50%
Notes:
1. Specified at 50% load.
2. Max. spec indicates 80% of the converter’s total available power. This 80%
is available from either output.
3. Specification applies to both + and –Vout.
4. Although no minimum load is required, at no load the output voltage may
increase up to 15%.
5. Cross regulation is specified as the effect on –Vout for the following percent
www.craneae.com
mA
ages of total output power: +Po = 20% and
–Po = 80% to +Po=80% and –Po=20%
6. Lin = 2 μH.
7. Max. duration of short circuit: 25°C – 90 seconds; 125°C – 30 seconds.
8. Load fault is a short circuit (<50 mohms). Recovery into resistive full load.
9. Input step transition ≥ 10 μs.Recovery is time to settle to within 1% of Vout
final value.
Page 10 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MCH SINGLE AND DUAL OUTPUT MODELS
90
90
90
80
80
12 VOLT
70
50 VOLT
60
50
70
28 VOLT
50 VOLT
EFFICIENCY
28 VOLT
EFFICIENCY
70
EFFICIENCY
80
12 VOLT
12 VOLT
60
50
40
40
0.25 0.5
0
OUTPUT POWER
0.75
0.25 0.5
0
OUTPUT POWER
1
1.25 1.5 1.75
ALL 5 VOLT MODELS
50 VOLT
50
40
30
30
28 VOLT
60
30
1
1.25 1.5 1.75
0.75
12 & 15 VOLT SINGLE MODELS
0.25 0.5
0
OUTPUT POWER
EFFICIENCY vs LOAD
EFFICIENCY vs LOAD
EFFICIENCY vs LOAD
FIGURE 6
FIGURE 5
1
1.25 1.5 1.75
0.75
12 & 15 VOLT DUAL MODELS
FIGURE 7
VIN
50 VDC
FULL LOAD TO HALF LOAD
12 VDC
40
100 mV / div.
ATTENUATION (dB)
20
100 mV / div.
20 V / div.
0
60
80
100
1
VOUT
HALF LOAD TO FULL LOAD
200μs / div.
10
60
FREQUENCY (kHz)
MCH2815S - Representative of all models
500μs / div.
MCH2805S
MCH2805S
LOAD TRANSIENT RESPONSE
LINE TRANSIENT RESPONSE
AUDIO REJECTION
FIGURE 9
VOUT
6
0
2
4
8
10 12 14 16 18
TIME (ms)
MCH2805S
Representative of all 5 volt models
FIGURE 10
VIN
+VOUT FULL LOAD TO HALF LOAD
–VOUT HALF LOAD TO FULL LOAD
50 VDC
12 VDC
200 mV / div.
20 V / div.
VIN
200 mV / div.
2V/div.
20V/div.
FIGURE 8
+VOUT
–VOUT FULL LOAD TO HALF LOAD
+VOUT HALF LOAD TO FULL LOAD
–VOUT
200μs / div.
MCH2815D
500μs / div.
MCH2815D
LINE TRANSIENT RESPONSE
LOAD TRANSIENT RESPONSE
FIGURE 12
FIGURE 13
TURN-ON INTO FULL LOAD
FIGURE 11
www.craneae.com
Page 11 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MCH SINGLE AND DUAL OUTPUT MODELS (CONT.)
20V/div.
VIN
0 V for –VOUT
+VOUT
5V/div.
–VOUT
0 V for +VOUT
4
±5 V
2
–5 V
±VOUT VOLTAGE CHANGE (%)
±VOUT VOLTAGE CHANGE (%)
4
±12 V
±15 V
0
-2
10
20
40
50
30
OUTPUT LOAD (%)
DUAL ISOLATED
50% LOAD +V; 50% TO 10% LOAD –V
AND
50% LOAD –V; 50% TO 10% LOAD +V
TURN-ON INTO FULL LOAD
–15 V
–12 V
0
+15 V
+12 V
+5 V
-2
-4
90/10 70/30 50/50 30/70 10/90
OUTPUT LOAD (%)
DUAL ISOLATED
90% TO 10% LOAD ON +V
10% TO 90% LOAD ON –V
-4
0
5
10 15 20
25 30 35 40 45
TIME (ms)
MCH2815D
Also representative of MCH2812S & D and MCH2815S
2
CROSS REGULATION
CROSS REGULATION
FIGURE 14
FIGURE 16
FIGURE 15
1.8
90
120
1.4
12 V
SINGLE
& DUAL
1.2
5V
DUAL
1.0
80
5V
SINGLE
60
SAFE OPERATING AREA
40
20
0.8
9
10
INPUT VOLTAGE
11
12
ALL MODELS
LOW LINE DROPOUT
FIGURE 17
www.craneae.com
NARROWBAND
TRIP POINT 125%
100
EMISSION LEVEL (dB μA)
15 V
SINGLE
& DUAL
Vout NOMINAL %
MAXIMUM POWER (W)
1.6
0
0
20
40
60
80
100
% OF FULL LOAD
120 140
160
OUTPUT VOLTAGE vs. OUTPUT LOAD
FIGURE 18
Page 12 of 18
Rev E - 20060508
70
CE
03
50
LI
M
IT
30
10
.015
0.1
1
FREQUENCY (MHz)
10
MCH FILTERED WITH FMSA
FIGURE 19
50
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MGH SINGLE AND DUAL OUTPUT MODELS
80
80
80
12 VOLT
12 VOLT
12 VOLT
70
50 VOLT
50
EFFICIENCY
28 VOLT
60
EFFICIENCY
70
70
EFFICIENCY
90
90
90
28 VOLT
60
50 VOLT
50
30
0.25 0.5 0.75 1 1.25 1.5 1.75
0
ALL 5 VOLT MODELS
OUTPUT POWER
30
0.25 0.5 0.75
0
OUTPUT POWER
EFFICIENCY vs LINE & LOAD
28 VOLT
50 VOLT
50
40
40
40
60
30
0.25 0.5 0.75 1 1.25 1.5 1.75
0
12 & 15 V DUAL MODELS
OUTPUT POWER
1 1.25 1.5 1.75
12 & 15 V SINGLES
EFFICIENCY vs LINE & LOAD
FIGURE 20
EFFICIENCY vs LINE & LOAD
FIGURE 21
FIGURE 22
0
60
50 VDC
FULL LOAD TO HALF LOAD
12 VDC
80
100 mV / div.
20 V / div.
40
Vin
100 mV / div.
ATTENUATION (dB)
20
Vout
HALF LOAD TO FULL LOAD
100
10
1
60
FREQUENCY (kHz)
MGH2815S - Representative of all models
200 s / div.
MGH2805S
500 s / div.
MGH2805S
LOAD TRANSIENT RESPONSE
LINE TRANSIENT RESPONSE
AUDIO REJECTION
Vout
6
0
2
4
8 10 12 14 16 18
TIME (ms)
MGH2805S
Representative of all 5 volt models
TURN-ON INTO FULL LOAD
FIGURE 26
www.craneae.com
Vin
+VOUT FULL LOAD TO HALF LOAD
–VOUT HALF LOAD TO FULL LOAD
50 VDC
200 mV / div.
20 V / div.
Vin
FIGURE 25
FIGURE 24
200 mV / div.
2V/div.
20V/div.
FIGURE 23
12 VDC
+Vout
–VOUT FULL LOAD TO HALF LOAD
+VOUT HALF LOAD TO FULL LOAD
–Vout
200 s / div.
MGH2815D
LINE TRANSIENT RESPONSE
FIGURE 27
Page 13 of 18
Rev E - 20060508
500 s / div.
MGH2815D
LOAD TRANSIENT RESPONSE
FIGURE 28
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
Typical Performance Curves: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MGH SINGLE AND DUAL OUTPUT MODELS (CONT.)
4
4
0 V for –Vout
5V/div.
–Vout
+Vout
2
0
±Vout VOLTAGE CHANGE (%)
Vin
±Vout VOLTAGE CHANGE (%)
20V/div.
–5
–15
–12
+15
+12
+5
-2
0 V for +Vout
0
5 10 15 20 25 30 35 40 45
TIME (ms)
MGH2815D
Also representative of MGH2812S & D and MGH2815S
TURN-ON INTO FULL LOAD
FIGURE 29
-4
CROSS REGULATION
FIGURE 30
TRIP POINT
125%
Vout NOMINAL %
SAFE OPERATING AREA
40
20
20
40 60 80 100 120 140 160
% OF FULL LOAD
OUTPUT VOLTAGE vs. OUTPUT LOAD
FIGURE 32
www.craneae.com
-2
CROSS REGULATION
60
0
0
90% TO 10% LOAD ON +V
10% TO 90% LOAD ON –V
80
0
±12
±15
-4
20 30 40
10
50
OUTPUT LOAD (%)
DUAL
50% LOAD +V; 50% TO 10% LOAD –V
AND
50% LOAD –V; 50% TO 10% LOAD +V
90/10 70/30 50/50 30/70 10/90
OUTPUT LOAD (%)
120
100
±5
2
Page 14 of 18
Rev E - 20060508
DUAL
FIGURE 31
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converter Cases
28 VOLT INPUT – 1.5 WATT
BOTTOM VIEW CASE A2
Seam Seal
Projection Weld
Squared corner and dot on
top of case indicate pin one.
0.805 max. (20.45)
0.697 (17.70)
1 2
3
4
Seal hole: 0.056 ±0.002 (1.42 ±0.05)
6
5
0.835 (21.21)
0.980 max. (24.89)
0.000
0.27 ±0.02
(6.9 ±0.5)
0.000
0.27 ±0.02
(6.9 ±0.5)
0.270 max
(6.98)
0.000
0.270 max
(6.86)
0.135 (3.43)
0.235 (5.97)
7
0.097 (2.46)
0.000
0.435?(11.05)
0.535 (13.59)
0.018 ± 0.002 dia.
(0.46 ± 0.05)
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin
Materials
Header
Kovar/Nickel/Gold
Cover
Kovar/Nickel
Pins
Kovar/Nickel/Gold matched glass seal
Case A2, Rev C, 20060110
Please refer to the numerical dimensions for accuracy. All information is believed to be accurate,
but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make
changes in products or specifications without notice.
Copyright © 1999-2006 Interpoint Corp. All rights reserved.
FIGURE 33: CASE A2
www.craneae.com
Page 15 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converter Cases
28 VOLT INPUT – 1.5 WATT
TOP VIEW CASE B
Differently colored glass bead around pin one or dimple in
header (bottom or side of case) indicates pin one.
Cover marking is oriented with pin one at the upper right corner.
0.880 max
(22.35)
1
2
3
4
5
6
7
8
9
0.900 (22.86)
0.800 (20.32)
0.700 (17.78)
0.600 (15.24)
0.500 (12.70)
0.400 (10.16)
0.300 ( 7.62)
0.200 ( 5.08)
0.100 ( 2.54)
18
17
16
15
14
13
12
11
10
(This view shows
straight leads.)
1.010 max
(25.65)
0.015
(0.38)
0.000
0.000
0.010
(0.25)
1.870 ref. (47.50)
0.50
(12.7)
0.08 (2.0)
0.250 max.
(6.35)
Straight Leads
Seam seal
1.140 ref. (28.96)
0.135 ref. (3.43)
1 0.010
(0.25)
Seal hole: 0.040 ±0.002 (1.02 ±0.05)
1
Gull wing leads are solder dipped.
Lead dimensions are prior to solder dip.
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
0.010 (0.25)
Bottom of case to
bottom of lead
CAUTION
Maximum reflow temperature is 220°C for a maximum of 30 seconds. SN60,
SN62, or SN63 are the recommended types of solder. See case B Solder Pads
for Solder Mask instructions.
Hand soldering should not exceed 300°C for 10 seconds per pin.
Materials
Header
Kovar/Nickel/Gold
Cover
Kovar/Nickel
Pins
Kovar/Nickel/Gold matched glass seal
Case B, Rev C, November 9, 2005
Please refer to the numerical dimensions for accuracy. All information is believed to be
accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right
to make changes in products or specifications without notice. Copyright © 1999-2006 Interpoint
Corp. All rights reserved.
FIGURE 34: CASE B
www.craneae.com
Gull Wing Leads
Option
Page 16 of 18
Rev E - 20060508
0.055
(1.40)
0.070
(1.78)
0.08
(2.0)
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
883, CLASS H, QML PRODUCTS – ELEMENT EVALUATION
ELEMENT EVALUATION
STANDARD
1
(NON-QML)
2
3
M/S
P
TEST PERFORMED
(COMPONENT LEVEL)
CLASS H,
QML
2
3
M/S
P
Element Electrical (probe)
yes
no
yes
yes
Element Visual
no
no
yes
yes
Internal Visual
no
no
yes
no
no
no
yes
yes
no
no
yes
yes
no
no
no
yes
Final Electrical
Wire Bond Evaluation
4
SLAM™/C-SAM:
Input Capacitors only
(Add’l test, not req. by H or K)
Definitions:
Element Evaluation: Component testing/screening per MIL-STD-883 as determined by MIL-PRF-38534
SLAM™: Scanning Laser Acoustic Microscopy
C-SAM: C - Mode Scanning Acoustic Microscopy
Notes:
1. Non-QML products do no meet all of the requirements of MIL-PRF-38534
2. M/S = Active components (Microcircuit and Semiconductor Die)
3. P = Passive components
4. Not applicable to EMI filters that have no wire bonds
www.craneae.com
Page 17 of 18
Rev E - 20060508
Crane Aerospace & Electronics Power Solutions
MCH/MGH Single and Dual DC/DC Converters
28 VOLT INPUT – 1.5 WATT
883, CLASS H, QML PRODUCTS – ENVIRONMENTAL
SCREENING
TEST
125°C
STANDARD
non-QML
125°C
/ES
non-QML
Class H
/883
QML
Pre-cap Inspection
Method 2017, 2032
yes
yes
yes
Temperature Cycle (10 times)
Method 1010, Cond. C, -65°C to 150°C, ambient
Method 1010, Cond. B, -55°C to 125°C, ambient
no
no
no
yes
yes
no
Constant Acceleration
Method 2001, 3000 g
Method 2001, 500g
no
no
no
yes
yes
no
Burn-In
Method 1015, 160 hours at 125°C case, typical
96 hours at 125°C case, typical
no
no
no
yes
yes
no
Final Electrical Test MIL-PRF-38534, Group A
Subgroups 1 through 6: -55°C, +25°C, +125°C case
Subgroups 1 and 4: +25°C case
no
yes
no
yes
yes
no
Hermeticity Test
Fine Leak, Method 1014, Cond. A
Gross Leak, Method 1014, Cond. C
Gross Leak, Dip (1 x 10-3)
no
no
yes
yes
yes
no
yes
yes
no
Final Visual Inspection
Method 2009
yes
yes
yes
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.
MCH/MGH Single and Dual. Rev E - 20060508. This revision supercedes all previous releases. All technical information is believed to be accurate, but no responsibility is assumed for errors or omissions. Interpoint reserves the right to make changes in products or specifications without notice. MCH/MGH Series is a trademark of Interpoint. Copyright © 1994 - 2006 Interpoint Corporation. All rights reserved. www.craneae.com
Page 18 of 18