LinkCom LCCE-020X112 Ac input 90~305vac scp / ovp / ocp Datasheet

LinkCom Manufacturing Co., Ltd
Model NO.
LCCE-020112
Model Name
Constant Current Power Supply
Part NO.
PLCCE0020112
SIZE
134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】
FEATURES
◆ AC Input 90~305Vac
◆ Protection: SCP / OVP / OCP
◆ High Operating ambient Temp: -20℃ ~ +60℃
◆ Power Factor:>0.95@115Vac;>0.9@230Vac;@full load
◆ Safety: TUV / CB
◆ EMC: CE
◆ Comply with Indoor/Outdoor Waterproof (IP 67)
◆ Dimension (L*W*H): 134 * 42 * 33.1 mm
◆ Dimension (L*W*H): 5.28 * 1.65 * 1.3 inch
◆ ROHS Compliant
Module : LCCE-020112
*(8)
*
*
*
*
*,# =SEE NOTES BELOW
LCCE-020112
MODEL
min.
SPECIFICATION
DC OUTPUT VOLTAGE RANGE (V)
norm.
8
14
PRESET ACCURACY (%) *(7)
1
1.05
OUTPUT CURRENT(A) *(5)
O/P NOISE (P-P, V) *(3)
2
LINE REGULATION (%) *(6)
1
LOAD REGULATION (%)
1
DC OUTPUT POWER
14.7 W
EFFICIENCY(typ @Full Load)
80%
INPUT VOLTAGE RANGE
90-305VAC, 127-431VDC, Normal:100-277VAC
INPUT FREQUENCY
Range:47-63Hz, Normal:50-60Hz
ACTIVE POWER FACTOR
PF>0.95@115VAC , PF>0.9 @230VAC at full load and rated output voltage
INRUSH CURRENT (typ)
COLD START 10A @ 230VAC
AC CURRENT
0.4A/115VAC 0.2A/230VAC
LEAKAGE CURRENT
SHORT CIRCUIT PROTECTION
<0.7mA/240VAC
short circuit protection will restart automatically after the fault condition is removed
OVER CURRENT PROTECTION
*
Constant Current
OVER V, PROTECTION
Shut down and latch off o/p voltage , re-power on to recover
OPERATING TEMP.*(4)
-20 to +60℃@full load
STORAGE TEMPERATURE
-40 to +80℃
RELATIVE HUMIDITY
10 to +90%, non-cond.
TEMP. COEFFICIENT
0.03% / ℃ (0-50℃, typ)
SAFETY
TUV EN61347-2-13 / CB
EMI
CE EN55015
DIMENSIONS(L*W*H)
134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】
NOTES:(1)All parameters not specially mentioned are measured 230VAC input.
(2)All specifications Typical @25℃, unless otherwise noted, at normal line and load.
(3)Ripple and Noise measured directly at pins/terminals at nom. load, 0.1uF bypass and 47uF electrolytic, pk-pk @20MHz bandwidth.
(4)Specified for free-air convection cooling.
(5)Minimum load is NOT required for proper operation .
(6)Line regulation measured from 100VAC to 277VAC.
(7)Preset accuracy measured at normal load, 120VAC input.
(8)100% Production Tested.
※Reference
max.
www.linkcom.com.tw For more information, please contact with: [email protected]
LinkCom Manufacturing Co., Ltd
Model NO.
LCCE-020112
Model Name
Constant Current Power Supply
Part NO.
PLCCE0020112
SIZE
134 * 42 * 33.1 mm【5.28 * 1.65 * 1.3 inch】
Dimensions
Unit:mm【inch】
※Reference
www.linkcom.com.tw For more information, please contact with :[email protected]