Keysight Technologies N432A Thermistor Power Meter Data Sheet 02 | Keysight | N432A Thermistor Power Meter – Data Sheet Why Keysight’s Power Meters and Sensors? Keysight’s only power meter that supports thermistor mount with useful enhancements for metrology and calibration lab environments. Key features –– Frequency range: 100 kHz to 18 GHz (sensor dependent) –– Power range: –30 dBm (1 μW) to +10 dBm (10 mW) –– High accuracy ± (0.1% of reading + 0.5 μW), excellent for 1 mW transfer calibration (with 478A-H75) –– Built in 6.5 digit ADC eliminates the need of external DMM –– Selectable bridge resistance (100/200/300/400 Ω) Reliable, high-performing solutions Every power meter and sensor from Keysight consistently delivers great results. A sure investment for many years to come Code-compatibility between power meters reduces the need for re-coding. Not only that, all Keysight power meters are backward-compatible with most legacy power sensors. One specific application: One right solution Keysight offers a wide selection of power meters and sensors for practically all application needs—wireless communications, radar pulse measurements, component test, and more. –– Remote interface flexibility –– DC substitution measurement, traceable to the U.S. National Institute of Standards and Technology (NIST) Global network support No matter where you are, Keysight is committed to giving you the 24-hour support you need regarding our products, applications, or services. Keysight’s power meters have long been recognized as the industry standard for RF and microwave power measurements. 03 | Keysight | N432A Thermistor Power Meter – Data Sheet We Listened to the Industry, Then Delivered a Better and Easier Replacement Solution for the Legacy 432A Analog Power Meter As today’s power measurements become more complex, it is increasingly difficult to make reliable, accurate power measurements. For more than 40 years, you’ve depended on Keysight’s 432A analog power meter, used with temperature compensated thermistor sensors to provide high accuracy over a wide temperature range. Today, the Keysight N432A digital thermistor power meter, loaded with enhancements, including a color digital display, and intuitive front panel interface will continue support your measurement needs with greater capability and expanded functionality. Best of all, you can get these extras at just a fraction of the price of the legacy 432A. LXI Class-C compliant N432A The N432A is a single-channel, average RF power measurement meter that supports thermistor sensors. The N432A has the capability to measure and display average power, RF bridge voltages (VRF0 and VRF1), compensation bridge voltages (VCOMP0 and VCOMP1), V0, and V1. It is also provided with a set of features such as zeroing and a built-in self-test. Developed using LXI technology, the N432A is an LXI Class-C compliant instrument.1 The N432A basic configuration consists of two key sections: bridge and meter logic. When a compatible thermistor sensor is connected to the N432A, the RF and compensation bridge circuits are formed in the bridge section. VRF, which is the voltage at the top of the RF bridge, is responsive to both input RF power and ambient temperature changes. On the other hand, VCOMP, which is the voltage at the top of the compensation bridge, is responsive only to ambient temperature changes. The VRF and VCOMP values are used in calculating the RF power. Meanwhile, the meter logic section processes VRF and VCOMP to produce a meter current proportional to RF power. 1. In general, the N432A is an easy‑to‑use instrument, especially with the availability of an integrated Web browser that provides a convenient way to view and modify the instrument network configuration. Besides the LAN interface, the N432A also supports industry standard GPIB and USB interfaces for measurement automation. LXI, an acronym for LAN eXtension for Instrumentation, is an instrument standard for devices that use the Ethernet (LAN) as their primary communication interface. 04 | Keysight | N432A Thermistor Power Meter – Data Sheet High accuracy— no thermoelectric error The high accuracy ± (0.1% of reading + 0.5 μW) over a wide temperature range featured in the legacy 432A power meter is also included in the N432A, making it excellent for 1 mW transfer calibration (with 478A-H75/H76*). Accuracy can be maintained on even the most sensitive range as the error due to thermoelectric effect is reduced to a negligible level. * Sensor compatibility The N432A is compatible with the Keysight 478A and 8478B thermistor sensors. The following table lists the frequency range and operating resistance for these two sensors: Thermistor sensor model Frequency range (GHz) Operating resistance (Ω) 478A 0.01 to 10 200 478A Option H63 0.000001 to 1 200 478A Option H75 0.001 to 1 200 478A Option H76 0.001 to 1 200 8478B 0.01 to 18 200 478-H75/H76 has a maximum SWR of 1.05 at 50 MHz For further information on the thermistor sensors, refer to the respective manuals. 05 | Keysight | N432A Thermistor Power Meter – Data Sheet Take a Closer Look N432A front panel High-resolution color LCD display for easy viewing of test results Soft keys provide menu selection Arrow keys enable navigation of parameter entry screens, values selection, and entering of text Display key allows selection of the display format for the active window (single/split screen) Display key allows selection of the display mode (windowed, expanded, or fullscreen) of numeric measurements Numeric keypad for easy entry of numeric values Power reference of 1 mW (0 dBm) Hard keys provide quick access to the most frequently used functions, such as System, Trigger, and Acquisition, etc. Channel sensor connector N432A back panel Ground connector DC recorder outputs (DC voltage corresponds to the power level of the channel input) Line power accepts voltage with automatic range selection VRF and VCOMP output terminals for calibrating the N432A and for precision power measurements Go beyond GPRB with USB and LAN/LXI-C interface 06 | Keysight | N432A Thermistor Power Meter – Data Sheet Specifications and Characteristics Specifications describe the instrument’s warranted performance and apply after a 30 minute warm-up. General specifications These specifications are valid over its operating/environmental range unless otherwise stated and after performing a zero and calibration procedure. Compatible power sensors Supplemental characteristics (shown in italics) are intended to provide additional information, useful in applying the instrument by giving typical (expected), but not warranted performance parameters. These characteristics are shown in italics or labeled as “typical,” “nominal” or “approximate.” Frequency range 100 kHz to 18 GHz, sensor dependent Power range –30 to +10 dBm (1 μW to 10 mW), thermistor-sensor dependent –– Keysight 478A thermistor sensor (100 kHz to 10 GHz, with option H63) –– Keysight 8478B thermistor sensor (10 MHz to 18 GHz) Meter power accuracy Power absolute accuracy ± (0.1% of reading + 0.5 μW) Meter voltage accuracy (1-year reference specifications) VRF and VCOMP V0 and V1 23 °C ± 5 °C: ± (0.0035% + 50 μV) [reading + range] 23 °C ± 5 °C: ± (0.0040% + 25 μV) [reading + range] Bridge resistance 100, 200, 300, or 400 Ω (user selectable) Display units Power Relative VRF, VCOMP, V0, and V1 Bridge resistance Watts (W) or dBm Percent (%) or dB VDC and mVDC Ohm Display resolution Power Default resolution Voltage Bridge resistance Selectable resolution of: 1.0, 0.1, 0.01 and 0.001 dB in logarithmic mode, or 1, 2, 3, and 4 significant digits in linear mode 0.01 dB in logarithmic mode or three digits in linear mode 6.5-digit resolution 6.5-digit resolution 07 | Keysight | N432A Thermistor Power Meter – Data Sheet Specifications and Characteristics (continued) Power meter functions Accessed by key entry Either hard keys, or soft key menu, and programmable Zero Zeros the meter. (Power reference calibrator is switched off during zeroing) Frequency Entered frequency range is used to interpolate the calibration factors table. Frequency range from 1 kHz to 999.9 GHz Bridge resistance type Setting the bridge resistance, user-selectable Rmeasure (factory set) or Ruser (measured by user) Cal factor Sets the cal factor versus frequency for the calibration factor for power sensor. Range: 1.00% to 150.00%, in 0.01% increments. Cal factor can be set from either CF table or single entry CF Relative Displays all successive measurements relative to the last displayed value Offset Allows power measurements to be offset by –100 to +100 dB, settable in 0.001 dB increments, to compensate for external loss or gain. Offset table can be set from either CF table or single entry CF Save/recall Store up to 10 instrument states via the save/recall menu Measurement averaging Selectable from 4 to 128 Duty cycle Duty cycle values between 0.001 to 99.999%, in 0.001% increments, can be entered to display a peak power representation of measured power. The following equation is used to calculate the displayed peak power value: peak power = measured power/duty cycle Limits High and low limits can be set in the range –150.000 to +230.000 dBm, in 0.001 dBm increments Preset default values dBm mode, relative off, power reference off, duty cycle off, offset off, frequency 50 MHz, measurement averaging 16, free run Display Color display with selectable single and split screen formats are available. User selectable on digital measurement type or analog scale presentation 1 mW (0 dBm) power reference 1.0 mW (0.0 dBm), 50 MHz from type N (f) connector on the front panel, for power meter/sensor function check. Accuracy (for two years) ± 0.4% (25 ± 10 ºC) ± 1.2% (0 to 45 ºC) SWR 1.05 (typical), 1.08 (0 °C to 45 °C) 08 | Keysight | N432A Thermistor Power Meter – Data Sheet Specifications and Characteristics (continued) Power meter general specifications Dimensions The following dimensions exclude front and rear protrusions: 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in) Weight Model N432A Net 3.6 kg (8.0 lb) Shipping 8.2 kg (18.1 lb) Rear panel connectors VRF output VRF BNC terminal outputs the RF bridge voltage, used to connect to external DMM for more precise power measurement VCOMP output VCOMP BNC terminal outputs the compensation bridge voltage, used to connect to external DMM for more precise power measurement Recorder output Analog 0 to 1 V, 1 kΩ output impedance, BNC connector GPIB, USB 2.0 and 10/100BaseT LAN Interfaces to allow communication with an external controller Ground Binding post, accepts 4 mm plug or bare wire connection Line power Input voltage range Input frequency range Power requirement 100 – 240 VAC, automatic selection 220 – 240 V ±10% 50 – 60 Hz, 400 Hz 400 Hz (100 – 120 Vac) 70 VA 09 | Keysight | N432A Thermistor Power Meter – Data Sheet Specifications and Characteristics (continued Environmental characteristics Electromagnetic compatibility Complies with the essential requirements of EMC Directive (2004/108/EC) as follows: –– IEC61326-1:2005 / EN61326-1:2006 –– CISPR11:2003 / EN55011:2007 (Group 1, Class A) The product also meets the following EMC standards: –– Canada: ICES/NMB-001:2004 –– Australia/New Zealand: AS/NZS CISPR 11:2004 Product safety This product conforms to the requirements of the following safety standards: –– IEC 61010-1:2001 / EN 61010-1:2001 –– CAN/CSA-C22.2 No.61010-1-04 –– ANSI/UL61010-1:2004 Low voltage directive This product conforms to the requirements of European Council Directive “2006/95/EC” Operating environment Temperature Maximum humidity Minimum humidity Maximum altitude 0 °C to 45 °C 95% at 40 °C (non-condensing) 15% at 40 °C (non-condensing) 4,600 m (15,000 ft) Storage conditions Non-operating storage temperature Non-operating maximum humidity Non-operating maximum altitude –40 °C to +70 °C 90% at 65 °C (non-condensing) 4,600 m (15,000 ft) Remote programming Interface Command language GPIB compatibility GPIB, USB, and LAN interfaces operates to IEEE 488.2 standard SCPI standard interface commands SH1, AH1, T6, TE0, L4, LE0, SR1, RL1, PP1, DC1, DT1, C0 10 | Keysight | N432A Thermistor Power Meter – Data Sheet Ordering Information Standard product N432A Thermistor power meter Standard shipped accessories Thermistor sensor adaptor cable 1.5 m* (5 ft) Power cord (country dependant) USB adaptor cable Keysight N432A thermistor power meter product reference CD-ROM Envelope—calibration certificate IO libraries media suite Warranty Standard 3-year, return-to-Keysight warranty and service plan 3 months for standard shipped accessories Power sensors, accessories, calibration, and documentation options * 478A-H13 Frequency range 100 kHz to 1 GHz, with maximum SWR 1.8 to 300 KHz, 1.3 to 1 GHz. Include 13 frequency points Standard Lab calibration 478A-H55 Frequency range 1 MHz to 1 GHz, with maximum SWR 1.3 478A-H63 Frequency range 100 kHz to 1 GHz, max SWR 1.8 to 300 kHz, 1.3 to 1 GHz 478A-H72 Frequency range 1 MHz to 1 GHz, with maximum SWR 1.2 478A-H73 Frequency range 1 MHz to 100 MHz, with maximum SWR 1.1, except 1.05 at 50 MHz 478A-H75 Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz 478A-H76 Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz. Standard lab calibration at 50 MHz 478A-H83 Frequency range 1 MHz to 1 GHz, with maximum SWR 1.3, except 1.05 at 50 MHz Include 8 frequency points Standard Lab calibration 478A-H93 Frequency range 1 MHz to 1 GHz, with maximum SWR 1.3, except 1.05 at 50 MHz Include 2 frequency points Standard Lab calibration 8478B-H01 Frequency range 10 MHz to 18 GHz, with maximum SWR 1.05 at 50 MHz 8478B-H27 Frequency range 10 MHz to 18 GHz. Include Standard Lab calibration at 9 MHz N4998A Thermistor sensor adaptor cable 1.5 m (5 ft) N4998B Thermistor sensor adaptor cable 3 m (10 ft) N4998C Thermistor sensor adaptor cable 6.1 m (20 ft) N432A-908 Rackmount kit with 1 unit with blank filler included N432A-909 Rackmount kit with 2 units side-by-side N432A-OBK English language user guide and English programming guide N432A-ABJ Japanese user guide and English programming guide N432A-0B1 English language user guide and installation guide N432A-0BF English language programming guide N432A-A6J Certificate of compliance calibration - ANSI/NCSL Z540 N432A-1A7 Compliant calibration test data - ISO17025 The 1.5 m (5 ft) standard cable can be replaced with a 3 or 6.1 m (10 or 20 ft) cable, charges apply 11 | Keysight | N432A Thermistor Power Meter – Data Sheet myKeysight www.keysight.com/find/mykeysight A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. www.lxistandard.org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. www.pxisa.org PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty www.keysight.com/find/ThreeYearWarranty Keysight’s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans www.keysight.com/find/AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. www.keysight.com/go/quality Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Channel Partners www.keysight.com/find/channelpartners Get the best of both worlds: Keysight’s measurement expertise and product breadth, combined with channel partner convenience. www.keysight.com/find/N432A For more information on Keysight Technologies’ products, applications or services, please contact your local Keysight office. The complete list is available at: www.keysight.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 55 11 3351 7010 001 800 254 2440 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 6375 8100 Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland United Kingdom 0800 001122 0800 58580 0800 523252 0805 980333 0800 6270999 1800 832700 1 809 343051 800 599100 +32 800 58580 0800 0233200 8800 5009286 0800 000154 0200 882255 0800 805353 Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) 0800 0260637 For other unlisted countries: www.keysight.com/find/contactus (BP-09-04-14) This information is subject to change without notice. © Keysight Technologies, 2014 Published in USA, November 21, 2014 5990-5740EN www.keysight.com