HWS300-1500 Series Single Output Industrial Power Supplies Features Limited Lifetime Warranty UL508 approved SEMI F47 Compliant (high line AC) Universal Input (85 - 265VAC) High Efficiency Class 1 Div 2 option (/RY suffix) Wide Range AC Input Key Market Segments & Applications Specifications Model Input Voltage range (47-63Hz) Input Current (Typ) (1) A HWS300 Inrush Current (1) Power Factor Temperature Coefficient Overcurrent Protection Overvoltage Protection Hold Up Time (Typ) Leakage Curr. (at 240VAC, 60Hz) Remote Sense Indicator Remote on/off Parallel operation DC Good Remote Adjust (PV) Operating Temperature Storage Temperature Humidity (non condensing) Cooling Withstand Voltage (4) Isolation Resistance Vibration (non operating) Shock Safety Agency Certifications (5) Line Dip Conducted & Radiated EMI Immunity Weight (Typ) Size (WxHxD) Warranty A V ms mA °C g in yrs HWS600 HWS1000 HWS1500 85 - 265VAC or 120 - 330VDC (6) 5V: 3.8/1.9; 5V: 7.5/3.6; 3.3V: 9.6/5.0; 3.3V: 15.0/8.0; 12-48V: 4.2/2.1 12-48V: 8.1/3.9 5-60V: 13.5/7.0 5-60V: 19.5/10.0 20 / 40 Meets EN61000-3-2 <0.02%/°C >105% (>101% of peak current for peak current capable models) See table on page 2 (Recycle AC or remote on/off to reset) 20 <0.75mA <1.2mA <1.5mA Yes Green LED = ON Yes (Isolated from output) Single wire connection (up to 5 units) Yes External voltage adjusts output, see options table -10°C to +70°C, derate linearly to 50% load from 50C to 70C (2, 3) -30 to +85°C Operating: 10 - 90%RH, Non operating 10 - 95%RH Internal fan Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. >100M at 25°C & 70%RH, Output to Ground 500VDC 10 - 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour < 196.1 m/s2 UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark Complies with SEMI F47 (200VAC line only) EN55011 / EN55022, FCC VCCI (HWS300, 600 & 1000: Class B, HWS1500: Class A) IEC61000-4-2, -3, -4, -6 (Level 3), -5, -8 (Level 4), -11 1,000 1,600 3,200 3.3-7.5V: 4000; 12V+: 3800 2.4 x 3.23 x 6.5” 3.94 x 3.23 x 6.5” 5 x 3.25 x 9.45” 5 x 3.25 x 11” Limited lifetime warranty (See TDK-Lambda’s terms and conditions) (1) 100/200VAC (2) HWS start up -20°C. (-40°C see options table) (3) HWS1000/1500 with 85VAC input: See installation manual (4) 2kVAC HWS1000/1500 Input to ground HWS1000: -10 to +71°C. HWS1000-5, HWS1500-3, -5 derate linearly above 40°C 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 61 (5) UL60601-1, EN60601-1, see options. UL508; HWS300/600 5V, 12V, 24V & 48V models (6) Not on HWS1500/ME, /HD or /RY versions (*) Class 1 Div 2 option (/RY suffix) Disclaimer: us.tdk-lambda.com/lp/legal.htm HWS300-1500 Series Output Ratings Model HWS300-3 HWS600-3 HWS1000-3 HWS1500-3 HWS300-5 HWS600-5 HWS1000-5 HWS1500-5 HWS1000-6 HWS1500-6 HWS1000-7 HWS1500-7 HWS300-12 HWS600-12 HWS1000-12 HWS1500-12 HWS300-15 HWS600-15 HWS1000-15 HWS1500-15 HWS300-24 HWS600-24 HWS1000-24 HWS1500-24 HWS1000-36 HWS1500-36 HWS300-48 HWS600-48 HWS1000-48 HWS1500-48 HWS1000-60 HWS1500-60 Voltage V 3.3V 3.3V 3.3V 3.3V 5V 5V 5V 5V 6V 6V 7.5V 7.5V 12V 12V 12V 12V 15V 15V 15V 15V 24V 24V 24V 24V 36V 36V 48V 48V 48V 48V 60V 60V Adjust Range V(3) 2.64 - 3.96 2.64 - 3.96 2.64 - 3.96 2.64 - 3.96 4-6 4-6 4-6 4-6 4.8 - 7.2 4.8 - 7.2 6 - 9V 6 - 9V 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 9.6 - 14.4 12 - 18 12 - 18 12 - 18 12 - 18 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 19.2 - 28.8 28.8 - 43.2 28.8 - 43.2 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 38.4 - 52.8 48 - 66 48 - 66 Max Curr. A 60 120 200 300 60 120 200 300 167 250 134 200 27 53 88 125 22 43 70 100 14 27 44 65/70 (1) 29.3 42/46.5 (1) 7 13 22 32 17.6 25.6/28 (1) Peak Curr. A(2) 300 160 240 100 80 16.5 31 50 105 33.3 70 25 20 42 Max. Pwr. W 198 396 660 990 300 600 1000 1500 1002 1500 1005 1500 324 648 1056 1500 330 645 1050 1500 336 648 1056 1560 1055 1512 336 624 1056 1536 1056 1536 Load Reg mV 30 30 40 60 30 30 40 60 60 60 60 60 96 96 100 72 120 120 120 90 192 192 150 144 150 150 384 384 300 288 360 360 Line Reg mV 20 20 20 36 20 20 20 36 36 36 36 40 48 48 48 48 60 60 60 60 96 96 96 96 144 144 192 192 192 192 240 240 Ripple Noise mV 120 120 120 150 120 120 120 150 150 150 150 150 120 120 150 150 150 150 150 150 150 150 150 200 200 200 200 200 200 200 400 400 Overvoltage V 4.13 - 4.95 4.13 - 4.95 4.13 - 4.62 4.12 - 4.62 6.25 -7.25 6.25 -7.25 6.25 - 7.0 6.25 - 7.0 7.5 - 8.4 7.5 - 8.4 9.38 - 10.5 9.37 - 10.5 15 - 17.4 15 - 17.4 15 - 17.4 15 - 17.4 18.8 - 21.8 18.8 - 21.8 18.8 - 21.8 18.7 - 21.8 30 - 34.8 30 - 34.8 30 - 34.8 30 - 34.8 45 - 49.7 45 - 49.7 55.2 - 64.8 55.2 - 64.8 55.2 - 64.8 55.2 - 64.8 69 - 75 69 - 75 Eff. typ % (1) 74/77 75/78 71/73 72/75 79/82 80/83 76/78 77/81 79/81 79/82 80/82 81/83 80/83 80/83 83/85 82/85 82/85 82/85 83/85 83/87 82/85 82/85 85/87 84/88 85/88 84/88 82/85 82/85 86/88 86/90 85/88 86/90 Notes (1) 100/200VAC (2) 200-265VAC Input, 10s maximum on time with 35% duty cycle (3) Use program input (PV) to adjust from 20-120% of nominal (20-110% for 48V & 60V models) Options Other Industrial Products Suffix Blank /A HWS LZSA SWS DPP, DLP & DSP /PV /HD /ME /RY Description HWS300-1500 the cover is fitted as standard Not Applicable HWS300-1500 the cover is fitted as standard HWS300, 600 (Standard on HWS1000 & 1500): 1-6V program voltage input to adjust output 20-120% of nominal (20-110% for 48V) (12V-48V models only) See HWS50-1500/HD Datasheet for details.-40 to +71(74)°C operation, conformally coated PCBs See HWS30-1500/ME Datasheet for details. UL60601-1, EN60950-1 medical certification ISA 12.12.01 (UL1604) - Class 1 Div 2 with dry contact relay DC Good signal (300W, 600W and 1500W 24V output models only, no UL508 certification, no remote on/off function.) 1-800-526-2324 • www.us.tdk-lambda.com/lp/ 15W to 150W single output 500W to 1500W Single output 50W to 1000W, low cost 10W to 480W DIN Rail Mount For Additional Information, please visit us.tdk-lambda.com/lp/products/hws-series.htm 62 Revision C5: Nov 2013