HYD Series Submersible precision stainless steel pressure transmitters FEATURES · 0...0.1 to 0...4 bar, (0...1 to 0...40 mH2O) · For corrosive media · 4...20 mA output · Field interchangeable · Intrinsically safe (option)9 MEDIA COMPATIBILITY Wetted materials: stainless steel 1.4404 (316L)8, Polyethylene, Viton (EPDM) Housing: protection class IP 68 (according to DIN EN 60529) respectively NEMA 6P1 ELECTRICAL CONNECTION SPECIFICATIONS Maximum ratings Supply voltage2 (reverse polarity protection) intrinsically safe version (option) Temperature limits Storage Operating Compensated 13...40 V 17...28 V +Vs -20 to +70°C -10 to +70°C 0 to +65°C +13 to 40 V red sensor V Proof pressure3 0.1 to 0.7 bar 0.7 to 1.5 bar 1.5 to 4.0 bar -Vs 6 bar 10 bar 15 bar black RL GND bare June 2008 / 580 1/4 www.sensortechnics.com HYD Series Submersible precision stainless steel pressure transmitters INDIVIDUAL PERFORMANCE CHARACTERISTICS (unless otherwise noted, VS = 24 V, tamb = 20°C, RL=550 Ω) C haracteristics Operating pressure Min. HYD0X1... HYD0X2... HYD0X4... HYD0X7... HYD1X0... HYD1X5... HYD2X0... HYD3X0... HYD4X0... Typ. 0 0 0 0 0 0 0 0 0 Max. U nit 0.1 0.2 0.4 0.7 1.0 1.5 2 3 4 bar Zero pressure offset 3.968 4.000 4.032 Full scale span6 15.968 16.000 16.032 Full scale output mA 20.0 4 Thermal effects (0 to 65°C) Offset Span ±0.015 ±0.015 %FSS/°C Non-linearity, hysteresis, repeatability5 ±0.2 %FSS Long term stability ±0.1 %FSS/year Response time (10 % to 90 %) 50 ms Power consumption (IL = 20 mA) 260 mW LOAD LIMITATION intrinsically safe version: R max = June 2008 / 580 Vs − 13 V 0.02 A R max = Vs − 17 V 0.02 A 2/4 www.sensortechnics.com HYD Series Submersible precision stainless steel pressure transmitters ELECTROMAGNETIC CAPABILITY7 Test conditions Criterion Radiated, radio frequency electromagnetic field immunity (RFI) EN61000-4-3: Grade 3 10 V/m, 80 MHz to 1000 MHz 80 % AMC (1 kHz) A Electrical fast transient / burst immunity (EFT) EN61000-4-4: Grade 3 ±2 kV B Electrostatic discharge immunity test (ESD) EN61000-4-2: Grade 4 ±8 kV, contact discharge B Immunity to conducted disturbances induced by radio-frequency fields EN61000-4-6: Grade 3 0,15 to 80 MHz 10 V, 80 % AMC (1 kHz) A Specification notes (for all devices): 1. The package is an all-sealed housing. For proper function the gage port is vented to the atmosphere through the connecting cable. Thus the vent tube of the cable end must have access to the ambient pressure. 2. The minimum supply voltage is directly proportional to the load resistance seen by the transmitter. For more details see the load limitation formula. 3. Proof pressure is the maximum pressure which may be applied without causing damage to the sensing element. 4. Thermal effects tested and guaranteed from 0°C to 65°C relative to 20°C. 5. Non-linearity refers to the Best Straight Line fit measured for offset, full scale span and 1/2 full scale span. 6. Span is the arithmetic difference in transmitter output signal measured at zero pressure and the maximum operating pressure. 7. Tests are in accordance with EN61000-6-2, April 99. 8. On special request. Hastelloy© is available. 9. Certificate: ATEX II 1G (CENELEC EEx ia IIC T4). June 2008 / 580 3/4 www.sensortechnics.com HYD Series Submersible precision stainless steel pressure transmitters Ø50 OUTLINE DRAWING 15 150 mass: typ. 800 g (without cable) 3m other lengths on request dimensions in mm WIRE CONNECTION Color Electrical connection red +Vs black -Vs transparent vent tube1 bare case/shield ORDERING INFORMATION HYD xxx G 4 C x S E Option: intrinsically safe9 HYD series submersible pressure ranges10 0X1: 0 to 0.1 bar 0X2: 0 to 0.2 bar 0X4: 0 to 0.4 bar 0X7: 0 to 0.7 bar 1X0: 0 to 1.0 bar 1X5: 0 to 1.5 bar 2X0: 0 to 2 bar 3X0: 0 to 3 bar 4X0: 0 to 4 bar cable length in m (standard 3 m) cable version output signal 4: 4 - 20 mA pressure mode G: gage pressure Note 10: Other pressure ranges between 0.1 and 4.0 bar are available on request Sensortechnics reserves the right to make changes to any products herein. Sensortechnics does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. June 2008 / 580 4/4 www.sensortechnics.com