Cypress CY7C924ADX 200 mbaud hotlinkâ® transceiver Datasheet

CY7C924ADX
200 MBaud HOTLink® Transceiver
Features
• Second generation HOTLink® technology
• Fibre Channel and ESCON® compliant 8B/10B
encoder/decoder
• 10 or 12 bit preencoded data path (raw mode)
• 8 or 10 bit encoded data transport (using 8B/10B coding)
• Synchronous or asynchronous TTL parallel interface
• UTOPIA compatible host bus interface
• Embedded/Bypassable 256-character synchronous FIFOs
• Integrated support for daisy-chain and ring topologies
• Domain or individual destination device addressing
• 50 to 200 MBaud serial signaling rate
• Internal PLLs with no external PLL components
• Dual differential PECL compatible serial inputs
• Dual differential PECL compatible serial outputs
• Compatible with fiber optic modules and copper cables
• Built-In Self-Test (BIST) for link testing
• Link Quality Indicator
• Single +5.0V ±10% supply
• 100-pin TQFP
• 0.35µ CMOS technology
• Pb-free package available
Functional Description
The 200 MBaud CY7C924ADX HOTLink Transceiver is a
point-to-point communications building block allowing the
transfer of data over high speed serial links (optical fiber,
balanced, and unbalanced copper transmission lines) at
speeds ranging between 50 and 200 MBaud. The transmit
section accepts parallel data of selectable width and converts
it to serial data, while the receiver section accepts serial data
and converts it to parallel data of selectable width. Figure 1
illustrates typical connections between two independent host
systems and corresponding CY7C924ADX parts. As a second
generation HOTLink device, the CY7C924ADX provides
enhanced levels of technology, functionality, and integration
over the field proven CY7B923/933 HOTLink.
The transmit section of the CY7C924ADX HOTLink can be
configured to accept either 8 or 10 bit data characters on each
clock cycle, and stores the parallel data in an internal Transmit
FIFO. Data is read from the Transmit FIFO and is encoded
using an embedded 8B/10B encoder to improve its serial
transmission characteristics. These encoded characters are
then serialized and output from two Positive ECL (PECL)
compatible differential transmission line drivers at a bit rate of
10 or 12 times the character rate.
The receive section of the CY7C924ADX HOTLink accepts a
serial bit stream from one of two PECL compatible differential
line receivers and, using a completely integrated PLL Clock
Synchronizer, recovers the timing information necessary for
data reconstruction. The recovered bit stream is deserialized
and framed into characters, 8B/10B decoded, and checked for
transmission errors. Recovered decoded characters are
reconstructed into either 8 or 10 bit data characters, written to
an internal Receive FIFO, and presented to the destination
host system.
Systems that present externally encoded or scrambled data at
the parallel interface may bypass the integrated 8B/10B
encoder/decoder. The embedded FIFOs may also be
bypassed to create a reference locked serial transmission link.
For those systems requiring even greater FIFO storage
capability, external FIFOs may directly couple to the
CY7C924ADX device through the parallel interface without
additional glue-logic.
You can configure the TTL parallel I/O interface as either a
FIFO (configurable for UTOPIA emulation or for depth
expansion through external FIFOs) or as a pipeline register
extender. The FIFO configurations are optimized for transport
of time-independent (asynchronous) 8 or 10 bit character
oriented data across a link. A Built-In Self-Test (BIST) pattern
generator and checker permits at-speed testing of the high
speed serial data paths in both the transmit and receive
sections, and across the interconnecting links.
HOTLink devices are ideal for a variety of applications where
parallel interfaces can be replaced with high speed,
point-to-point serial links. Some applications include interconnecting workstations, backplanes, servers, mass storage, and
video transmission equipment.
Cypress Semiconductor Corporation
Document #: 38-02008 Rev. *E
•
198 Champion Court
•
System Host
Transmit
FIFO
Receive
FIFO
Serial Link
Status
8B/10B
Decoder
Deserializer
Framer
Serializer
Encoder
8B/10B
Status
Transmit
Data
Control
CY7C924ADX
CY7C924ADX
Data
Transmit
8B/10B
Encoder
Serializer
Framer
Deserializer
Decoder
8B/10B
Serial Link
Control
FIFO
Transmit
System Host
Data
Receive
FIFO
Receive
Figure 1. HOTLink System Connections
Receive
Data
San Jose, CA 95134-1709
•
408-943-2600
Revised March 27, 2007
CY7C924ADX
CY7C924ADX Transceiver Logic Block Diagram
TXDATA
TX
STATUS
CONTROL
TXCLK
MODE
REFCLK
11
RX
STATUS
RXDATA
RXCLK
9
13
13
3
4
Mode
Control
Input Register
Output Register
Address Register
MUX
MUX
Output Register
Flags
Mode
Receive
FIFO
Flags
Transmit
FIFO
CONTROL
AM*
TXEN*
RXEN*
TXSTOP*
TXRST*
RXRST*
RFEN
TXBISTEN*
RXBISTEN*
RESET*[1:0]
Transmit
PLL Clock
Multiplier
MUX
Elasticity
Buffer
MUX
Receive
Formatter
Pipeline Register
Byte-Unpacker
Address Matching
Transmit
Formatter
Pipeline Register
Byte-Packer
Receive
Control
State
Machine
BIST LFSR
8B/10B Encoder
Transmit
Control
State
Machine
MUX
Serial Shifter
Bit Clock
MODE
RANGESEL
SPDSEL
RXMODE[1:0]
FIFOBYP*
EXTFIFO
ENCBYP*
BYTE8/10*
TEST*
BIST LFSR
8B/10B Decoder
Deserializer
Framer
Receive
Clock/Data
Recovery
Clock
Divider
Bit Clock
TX STATUS
TXEMPTY*
TXHALF*
TXFULL*
Routing Matrix
LOOPBACK
CONTROL
DLB[1:0]
LOOPTX
Signal
Validation
3
INA
LOOPBACK OUTA
OUTB
CURSETB
CURSETA
CONTROL
Document #: 38-02008 Rev. *E
RXSTATUS
LFI*
RXEMPTY*
RXHALF*
RXFULL*
INB
A/B*
CARDET
Page 2 of 58
CY7C924ADX
VSSA
RXBISTEN*
VSSA
CURSETB
VDDA
OUTB+
VSSA
OUTB–
VSSA
INB–
VDDA
INB+
VDDA
OUTA+
VSSA
OUTA–
VSSA
INA–
VDDA
INA+
TQFP
Top View
VDDA
VDDA
CURSETA
VSSA
CARDET
Pin Configuration
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76
TEST*
1
75
SPDSEL
A/B*
2
74
RANGESEL
LFI*
3
73
RFEN
DLB[1]
4
72
TXFULL*
DLB[0]
5
71
AM*
LOOPTX
6
70
TXHALF*
TXBISTEN*
7
69
RXEN*
RXCLK
8
68
TXCLK
TXSTOP*
9
67
RXRST*
RXFULL*
10
66
VSS
RXSC/D*
VSS
11
65
REFCLK
12
64
VDD
VSS
13
63
VSS
VDD
14
62
VDD
VSS
15
61
RXDATA[0]
TXRST*
16
60
TXEMPTY*
VDD
17
59
RXDATA[1]
CY7C924ADX
TXEN*
18
58
TXSOC/TXDATA[11]
RXHALF*
19
57
VSS
TXSC/D*
20
56
TXSVS/TXDATA[10]
RXEMPTY*
21
55
VDD
TXDATA[0]
22
54
TXHALT*/TXDATA[9]
RXSOC/RXDATA[11]
23
53
RXDATA[2]
RXMODE[1]
24
52
RESET*[1]
RXMODE[0]
25
51
RESET*[0]
Document #: 38-02008 Rev. *E
EXTFIFO
BYTE8/10*
RXDATA[3]
RXDATA[4]
RXDATA[5]
TXINT/TXDATA[8]
TXDATA[7]
RXDATA[6]
TXDATA[6]
RXDATA[7]
TXDATA[5]
VSS
VSS
VSS
TXDATA[4]
VDD
TXDATA[3]
RXINT/RXDATA[8]
TXDATA[2]
TXDATA[1]
RXDATA[9]
RXRVS/RXDATA[10]
FIFOBYP*
VSS
ENCBYP*
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50
Page 3 of 58
CY7C924ADX
Pin Descriptions
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
Transmit Path Signals
44, 42,
40, 36,
34, 32,
30, 22
TXDATA[7:0]
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Parallel Transmit Data Input. Bus width can be configured to accept either
8 or 10 bit characters. When the encoder is bypassed (ENCBYP* is LOW),
TXDATA[7:0] functions as the least significant eight bits of the 10 or 12 bit
preencoded transmit character.
46
TXINT/
TXDATA[8]
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Transmit Interrupt Input. This input is only interpreted if both the Transmit
FIFO and encoder are enabled (FIFOBYP* and ENCBYP* are HIGH). Any
state change (0→1 or 1→0) in TXINT, forces a character into the transmit
encoder and shifter before accessing the next Transmit FIFO contents. This
signal passes around, not through, the Transmit FIFO.
When TXINT transitions from 0→1, a C0.0 (K28.0) special code is sent. When
TXINT transitions from 1→0, a C3.0 (K28.3) special code is sent. These
special codes force a similar signal transition on the RXINT output of an
attached CY7C924ADX HOTLink Transceiver.
When the Transmit FIFO is bypassed and the encoder is enabled (FIFOBYP*
is LOW and ENCBYP* is HIGH), this input is ignored.
When the Transmit FIFO is bypassed and the encoder is bypassed
(FIFOBYP* and ENCBYP* are LOW), TXDATA[8] functions as the 9th bit of
the 10 or 12 bit preencoded transmit character.
54
TXHALT*/
TXDATA[9]
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Transmit FIFO Halt Immediate Input. When the Transmit FIFO and the
encoder are enabled (FIFOBYP* and ENCBYP* are HIGH) and TXHALT*
asserts LOW, data transmission from the FIFO is suspended and the HOTLink
transmits idle characters (K28.5). During this time, data can still be loaded into
the FIFO. When TXHALT* is deasserted HIGH, normal data processing
proceeds.
When the encoder is bypassed (ENCBYP* is LOW), TXDATA[9] always
functions as the tenth bit of the 10 or 12 bit preencoded transmit character.
When the Transmit FIFO is bypassed and the encoder is enabled (FIFOBYP*
is LOW and ENCBYP* is HIGH), this input is ignored
56
TXSVS/
TXDATA[10]
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Transmit Send Violation Symbol Input. When the encoder is enabled and
the Transmit FIFO is enabled (ENCBYP* and FIFOBYP* are HIGH), this input
is interpreted along with TXSOC and TXSC/D* (see Table 2 on page 15 for
details). When the Transmit FIFO is disabled (FIFOBYP* is LOW) and the
TXSVS bit is set, the character on the TXDATA is ignored and a C0.7 exception
is sent instead.
When the encoder is bypassed and in 10 bit mode (ENCBYP* and BYTE8/10*
are LOW), TXDATA[10] functions as the eleventh bit of the 12 bit preencoded
transmit character.
When the Encoder is bypassed and in 8 bit mode (ENCBYP* is LOW and
BYTE8/10* is HIGH), this input is ignored.
58
TXSOC/
TXDATA[11]
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Transmit Start of Cell Input. When the Transmit FIFO and encoder are
enabled (ENCBYP* and FIFOBYP* are HIGH), this input is a message frame
delimiter that indicates the beginning of a data packet. It is interpreted along
with TXSVS and TXSC/D* (see Table 2 for details).
When the Transmit FIFO is bypassed (FIFOBYP* is LOW) and the encoder is
enabled (ENCBYP* is HIGH) this input is ignored.
When in 12 bit encoder bypass mode (ENCBYP* and BYTE8/10* are LOW),
TXDATA[11] functions as the twelfth bit (MSB) of the 12 bit preencoded
transmit character.
When the encoder is bypassed and in 8 bit mode (ENCBYP* is LOW and
BYTE8/10* is HIGH), this input is ignored.
Document #: 38-02008 Rev. *E
Page 4 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
20
TXSC/D*
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Transmit Special Character or Data Select Input. When the Transmit FIFO
is enabled and the encoder is enabled (FIFOBYP* and ENCBYP* are HIGH),
this input is interpreted along with TXSVS and TXSOC (see Table 2 on page
15 for details).
When the Transmit FIFO is bypassed and encoding is enabled (FIFOBYP* is
LOW and ENCBYP* is HIGH), this signal controls whether the TXDATA[7:0]
is sent as a data or control character.
When the encoder is bypassed (ENCBYP* is LOW) TXSC/D* is ignored.
18
TXEN*
TTL input, sampled
on TXCLK↑ or
REFCLK↑,
Internal Pull Up
Transmit Enable Input. Data enable for the TXDATA[11:0] data bus write
operations. Active HIGH when configured for Cascade timing (EXTFIFO is
HIGH), active LOW when configured for UTOPIA timing (EXTFIFO is LOW).
When the Transmit FIFO is enabled (FIFOBYP* is HIGH) and TXEN* is
asserted, data loads into the FIFO on every rising edge of TXCLK. When
TXEN* is deasserted with TXHALT* and TXSTOP* deasserted, data
continues to read out of the Transmit FIFO and is sent serially until the FIFO
empties. At this time, C5.0 (K28.5) idle characters are transmitted.
When the Transmit FIFO is bypassed (FIFOBYP* is LOW) and TXEN* is
asserted, the parallel data on the TXDATA bus is clocked in and transmitted
on every appropriate REFCLK rising edge. When TXEN* is deasserted, the
parallel data bus is ignored and C5.0 sync characters are transmitted instead.
9
TXSTOP*
TTL input, sampled
on TXCLK↑,
Internal Pull Up
Transmit Stop on Start_Of_Cell Input. While the Transmit FIFO and encoder
are enabled (FIFOBYP* and ENCBYP* are HIGH), this signal is used to
prevent queued data characters from being serially transmitted. While
TXSTOP* is deasserted, data flows through the Transmit FIFO without interruption. When TXSTOP* is asserted, data transfers continue until a TXSOC
bit is detected in the character stream, at which point data transmission
ceases. When transmission is stopped, C5.0 (K28.5) characters are sent
instead.
If data transmission is suspended due to a SOC character, pulsing TXSTOP*
deasserted then asserted will allow only the next cell (delimited by SOC bits)
to be transmitted.
When the Transmit FIFO is bypassed (FIFOBYP* = LOW) TXSTOP* has no
function.
When the Transmit FIFO is enabled (FIFOBYP* is HIGH) and the encoder is
bypassed (ENCBYP* is LOW), TXDATA[9]/TXHALT* is a data input and not
TXHALT*. In this mode, the TXSOC bit is not interpreted and the TXSTOP*
input assumes the same operation as TXHALT*. When TXSTOP* is asserted,
data reads from the Transmit FIFO are suspended and alternating disparity
10 bit equivalents of C5.0 are transmitted instead.
68
TXCLK
TTL clock input,
Internal Pull Up
Transmit FIFO Clock. The input clock for the parallel interface when the
Transmit FIFO is enabled (FIFOBYP* is HIGH). Samples all Transmit FIFO
related interface signals.
72
TXFULL*
3-state TTL output,
changes following
TXCLK↑ or
REFCLK↑
Transmit FIFO Full Status Flag. Active HIGH when configured for Cascade
timing (EXTFIFO is HIGH), active LOW when configured for UTOPIA timing
(EXTFIFO is LOW). The TXFULL* output is enabled when AM* is asserted,
otherwise it is High-Z.
When the Transmit FIFO is enabled (FIFOBYP* is HIGH), TXFULL* indicates
a Transmit FIFO full condition. When TXFULL* is first asserted, the Transmit
FIFO accepts up to eight additional write cycles without data loss.
When the Transmit FIFO is bypassed (FIFOBYP* is LOW), with RANGESEL
HIGH or SPDSEL LOW, TXFULL* toggles at half the REFCLK rate to provide
a character rate indication.
Document #: 38-02008 Rev. *E
Page 5 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
70
TXHALF*
3-state TTL output,
changes following
TXCLK↑ or
REFCLK↑
Transmit FIFO Half-full Status Flag. The TXHALF* flag is always active
LOW, regardless of the EXTFIFO* setting.
When the Transmit FIFO is enabled, TXHALF* is asserted LOW when the
Transmit FIFO is half full or more (128 characters).
TXHALF* is only set to High-Z state by the assertion of RESET*[1:0] LOW.
60
TXEMPTY*
3-state TTL output,
changes following
TXCLK↑ or
REFCLK↑
Transmit FIFO Empty Status Flag. Active HIGH when configured for
Cascade timing (EXTFIFO is HIGH), active LOW when configured for UTOPIA
timing (EXTFIFO is LOW). The TXEMPTY* output is enabled when AM* is
asserted, otherwise it is High-Z
When the Transmit FIFO is enabled (FIFOBYP* is HIGH), TXEMPTY* is
asserted either when no data has been loaded into the Transmit FIFO, or when
the Transmit FIFO has been emptied by either a Transmit FIFO reset or by
the normal transmission of the FIFO contents.
When the Transmit FIFO is bypassed (FIFOBYP* is LOW), TXEMPTY* is
asserted to indicate that the transmitter can accept data.
When TXBISTEN* is asserted LOW, TXEMPTY* becomes the transmit
BIST-progress indicator (regardless of the logic state of FIFOBYP*). In this
mode TXEMPTY* is asserted for one TXCLK or REFCLK period at the end of
each transmitted BIST sequence, depending on the FIFOBYP* setting.
16
TXRST*
TTL input, internal
pull-up, sampled on
TXCLK↑,
Internal Pull Up
Transmit FIFO Reset. When TXRST* is asserted for eight or more TXCLK
cycles, a reset operation begins on the Transmit FIFO. This input is ignored
when the Transmit FIFO is bypassed.
7
TXBISTEN*
TTL input,
asynchronous,
Internal Pull Up
Transmitter BIST Enable. When TXBISTEN* is LOW, the transmitter
generates a 511-character repeating built-in self test (BIST) sequence, that
can validate link integrity. The transmitter returns to normal operation when
TXBISTEN* is HIGH. All Transmit FIFO read operations suspend when BIST
is active.
Receive Path Signals
41, 43,
45, 47,
48, 53,
59, 61
RXDATA[7:0]
Bidirectional TTL,
changes following
RXCLK↑, or sampled
by RXCLK↑
Parallel Data Output and Serial Address Register Access. These outputs
change following the rising edge of RXCLK, when enabled to output data (the
device is addressed by AM* and selected by RXEN*). The contents of this bus
are interpreted differently based on the levels present on ENCBYP*,
BYTE8/10*, RXSC/D*, and when accessing the Serial Address Register.
When the decoder is bypassed (ENCBYP* is LOW), RXDATA[7:0] functions
as the least significant eight bits of the 10 or 12 bit preencoded receive
character.
33
RXINT/
RXDATA[8]
Bidirectional TTL,
changes following
RXCLK↑, or sampled
by RXCLK↑
Receive Interrupt Output. When the Receive FIFO and decoder are enabled
(FIFOBYP* and ENCBYP* are HIGH) and a C0.0 (K28.0) special code is
received, RXINT is set HIGH. When a C3.0 (K28.3) special code is received
RXINT is set LOW. These special codes are generated in response to equivalent transitions on the TXINT input of an attached CY7C924ADX HOTLink
transceiver.
This signal is extracted before the Receive FIFO and (except for Receive
Discard Policy 0) the associated command codes are not considered “data”
to be entered into the Receive FIFO and are discarded.
When the Receive FIFO is bypassed (FIFOBYP* is LOW) and the decoder is
enabled (ENCBYP* is HIGH), this output has no function.
When the decoder is bypassed (ENCBYP* is LOW), RXDATA[8] functions as
the ninth bit of the 10 or 12 bit undecoded receive character.
Document #: 38-02008 Rev. *E
Page 6 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
31
RXDATA[9]
Bidirectional TTL,
changes following
RXCLK↑, or sampled
by RXCLK↑
Receive Data Output. When the decoder is enabled in 10 bit mode
(ENCBYP* is HIGH and BYTE8/10* is LOW), this output is the tenth bit (MSB)
of the 10 bit decoded and unpacked data character. When the Decoder is
enabled and in 8 bit mode this output is ignored.
When the Decoder is bypassed (ENCBYP* is LOW), RXDATA[9] functions as
the tenth bit of the 10 or 12 bit undecoded receive character.
29
RXRVS/
RXDATA[10]
Bidirectional TTL,
changes following
RXCLK↑, or sampled
by RXCLK↑, Internal
Pull Up
Received Violation Symbol Indicator. For data accesses with the Receive
FIFO and decoder are enabled (FIFOBYP* and ENCBYP* are HIGH) this
signal is used as an output. It is decoded in conjunction with RXSC/D* and
RXSOC, according to Table 6 on page 22, to indicate the presence of specific
Special Character codes in the received data stream. For data accesses with
the Receive FIFO disabled and the Decoder enabled, this output indicates a
code word violation detection on the serial inputs.
When the Decoder is bypassed (ENCBYP* is LOW) and in 10 -bit mode
(BYTE8/10* is LOW), RXDATA[10] functions as the eleventh bit of the 12 bit
undecoded receive character. In 8 bit mode this output is unused and is driven
LOW.
RXRVS reports BIST pattern mismatches when RXBISTEN* is LOW.
When accessing the Serial Address Register, this signal is a “read/write”
control input. RXRVS LOW allows the host system to write the Serial Address
Register (RXDATA[9:0] and RXSC/D* are inputs). RXRVS HIGH allows the
host system to read the Serial Address Register (RXDATA[9:0] and RXSC/D*
are outputs).
23
RXSOC/
RXDATA[11]
Bidirectional TTL,
changes following
RXCLK↑, or sampled
by RXCLK↑
Receive Start Of Cell. When the Receive FIFO and decoder are enabled
(FIFOBYP* and ENCBYP* are HIGH), this output is decoded in conjunction
with RXSC/D* and RXRVS, according to Table 6, to indicate the presence of
specific Special Character codes in the received data stream.
When the Decoder is bypassed (ENCBYP* is LOW) and in 10 bit mode
(BYTE8/10* is LOW), RXDATA[11] is the twelfth bit (MSB) of the 12 bit
undecoded receive character. In 8 bit mode (BYTE8/10* is HIGH) this output
is unused and is driven LOW.
65
RXSC/D*
Bidirectional TTL,
changes following
RXCLK↑, or sampled
by RXCLK↑
Received Special Character or Data Indicator. For data accesses with the
Receive FIFO and decoder enabled (FIFOBYP* and ENCBYP* are HIGH) this
signal is an output. It is decoded in conjunction with RXSOC and RXRVS, in
accordance with Table 6, to indicate the presence of specific Special
Character codes in the received data stream. For data accesses with the
Receive FIFO disabled and the decoder enabled, this output indicates that the
parallel output RXDATA[7:0] is a Special Character code.
When accessing the Serial Address Register, this signal is an input that selects
the addressing mode. RXSC/D* HIGH configures the Serial Address Register
for Unicast address matching. RXSC/D* LOW configures the Serial Address
Register for Multicast address matching.
When operated with the decoder bypassed (ENCBYP* is LOW) this pin has
no function.
Document #: 38-02008 Rev. *E
Page 7 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
Receive Enable. Data enable for the RXDATA[11:0] data bus write and read
operations. Active HIGH when configured for Cascade timing (EXTFIFO is
HIGH), active LOW when configured for UTOPIA timing (EXTFIFO is LOW).
When the Receive FIFO is enabled (FIFOBYP* is HIGH) and RXEN* is
asserted, data is read out of the FIFO on every rising edge of RXCLK. When
RXEN* is deasserted, reads are inhibited and the RXDATA bus is not driven.
When the Receive FIFO is bypassed (FIFOBYP* is LOW) and RXEN* is
asserted, parallel data is clocked out Receive Output Register to the RXData
bus on every RXCLK edge. When RXEN* is deasserted, the RXDATA bus is
not driven.
RXEN* also controls the read and write access to the Serial Address Register.
69
RXEN*
TTL input, sampled
on RXCLK↑,
Internal Pull Up
8
RXCLK
Bidirectional TTL
Receive Clock. When the Receive FIFO is enabled (FIFOBYP* is HIGH), this
clock, Internal Pull-Up clock is the Receive interface input clock and is used to control Receive FIFO
read, reset, and serial register access operations. When the Receive FIFO is
bypassed (FIFOBYP* is LOW), this clock is output continuously at the
character rate of the data being received (1/10 or 1/12 of the serial bit rate).
10
RXFULL*
3-state TTL output,
changes following
RXCLK↑
19
RXHALF*
TTL output, changes Receive FIFO Half-full Flag. The RXHALF* flag is always active LOW,
following RXCLK↑
regardless of the EXTFIFO* setting.
When the Receive FIFO is enabled (FIFOBYP* is HIGH), this signal is
asserted when the Receive FIFO is half full or more (128 characters). When
the Receive FIFO is bypassed, RXHALF* is deasserted.
RXHALF* is forced to the High-Z state only during a “full-chip” reset (that is,
while RESET*[1:0] are LOW).
Document #: 38-02008 Rev. *E
Receive FIFO Full Flag. Active HIGH when configured for Cascade timing
(EXTFIFO is HIGH), active LOW when configured for UTOPIA timing
(EXTFIFO is LOW). The RXFULL* output is enabled when AM* is asserted,
otherwise it is High-Z.
When the Receive FIFO is addressed (FIFOBYP* is HIGH and the device is
addressed by AM* and selected by RXEN*), RXFULL* is asserted when the
Receive FIFO has room for eight or fewer writes. An RXFULL* condition may
indicate loss of data.
When the Receive FIFO is bypassed (FIFOBYP* is LOW), RXFULL* and
RXHALF* are deasserted to indicate that valid data may be present.
RXFULL* is also used as a BIST progress indicator, and pulses asserted once
every pass through the 511-character BIST loop.
The RXFULL* output is enabled when AM* is asserted, otherwise it is High-Z
Page 8 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
Receive FIFO Empty Flag. Active HIGH when configured for Cascade timing
(EXTFIFO is HIGH), active LOW when configured for UTOPIA timing
(EXTFIFO is LOW). The RXFULL* output is enabled when AM* is asserted,
otherwise it is High-Z.
When the Receive FIFO is enabled (FIFOBYP* is HIGH), RXEMPTY* is
asserted when no data remains in the Receive FIFO. Any read operation
occurring when RXEMPTY* is asserted results in no change in the FIFO
status, and the data from the last valid read remains on the RXDATA bus.
When the Receive FIFO is bypassed but the Decoder is enabled, RXEMPTY*
is used as a valid data indicator. The RXMODE[1:0] settings allow the user to
determine which data is valid and allows selective flagging of idle characters.
When RXEMPTY* is deasserted it indicates that a valid character (as selected
by RXMODE[1:0]) is present at the RXDATA outputs. When asserted it
indicates that a C5.0 (K28.5) rejected by the current RXMODE[1:0] setting is
present on the RXDATA output bus.
If both the Receive FIFO and the Decoder are bypassed, RXEMPTY* is
deasserted to indicate that all received characters are valid.
The TXFULL* output is enabled when AM* is asserted, otherwise it is High-Z.
21
RXEMPTY*
3-state TTL output,
changes following
RXCLK↑
67
RXRST*
TTL input, sampled Receive FIFO Reset. When the Receive FIFO is addressed (FIFOBYP* is
on RXCLK↑, Internal HIGH and device is selected by AM*) and RXRST* is sampled asserted for
Pull Up
eight or more RXCLK cycles, a Receive FIFO reset is initiated. The RXRST*
input is also asserted to access the Serial Address Register.
73
RFEN
TTL input,
asynchronous,
Internal Pull Up
Reframe Enable. Controls when the framer is enabled to adjust the character
boundaries based on detection of one or more K28.5 characters in the data
stream. When HIGH, the framer can adjust the character boundaries relative
to the received serial data stream to match those of the remote transmitter.
When LOW, the boundary is fixed.
77
RXBISTEN*
TTL input,
asynchronous,
Internal Pull Up
Receiver BIST Enable. When asserted, built-in self test (BIST) is active and
the receiver is configured to perform a character for character match of the
incoming data stream with a 511-character BIST sequence. The result of
character mismatches are indicated on RXRVS. Completion of each
511-character BIST loop is accompanied by an assertion pulse on the
RXFULL* flag.
Control Signals
71
AM*
TTL input, sampled
by TXCLK↑,
RXCLK↑, and
REFCLK↑
Address Match. This signal is a qualifier for TXEN*, RXEN*, TXRST*, and
RXRST*. It also controls three-state enables for the TXFULL*, TXEMPTY*,
RXFULL*, and RXEMPTY* signals.
6
LOOPTX
TTL input,
asynchronous,
Internal Pull Down
Serial-in to Serial-out LOOP Select. This input controls the LOOP-through
function in which the Clock/Data Recovery PLL recovers the serial data and
then retransmits it using the Transmit PLL as the bit rate reference. It selects
between the output of the Transmit FIFO and the output of the Elasticity Buffer
as the input to the Transmit Encoder. When LOW, the Transmit FIFO is the
source of data for transmission. When HIGH, the Elasticity Buffer is the source
of data for transmission and serial input data is reclocked and routed to the
serial outputs.
The LOOPTX function can only be used if the FIFOs are enabled (FIFOBYP*
= HIGH).
12
REFCLK
TTL input clock
Reference Clock. This clock input is the timing reference for the transmit and
receive PLLs. When the Transmit FIFO is bypassed, REFCLK is also the clock
for the external transmit data interface.
See Table 5 on page 19 for the relationships among REFCLK, SPDSEL,
RANGESEL, FIFOBYP*, ENCBYP* and BYTE8/10*.
Document #: 38-02008 Rev. *E
Page 9 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
75
SPDSEL
Static control input
TTL levels Normally
wired HIGH or LOW
Speed Select. Selects one of two operating data rate ranges for the device.
When the operating symbol rate is between 100 and 200 MBaud, SPDSEL
must be HIGH. When the operating symbol rate is between 50 and 100
MBaud, SPDSEL must be LOW (see Table 5 on page 19).
74
RANGESEL
Static control input
TTL levels Normally
wired HIGH or LOW
Range Select. Selects the proper prescaler for the REFCLK input. See
Table 5 for the various relationships among REFCLK, SPDSEL, RANGESEL,
FIFOBYP*, ENCBYP* and BYTE8/10*.
When the Transmit FIFO is bypassed (FIFOBYP* is LOW) and REFCLK is a
nonunity multiple of the character rate (RANGESEL HIGH or SPDSEL LOW),
TXFULL* toggles at half the REFCLK rate to provide a character rate
indication, and to show when data can be accepted.
49
EXTFIFO
Static control input
TTL levels Normally
wired HIGH or LOW
External FIFO Select. EXTFIFO indicates whether the device is used with
external FIFOs. It modifies the active level of the RXEN* and TXEN* inputs
and the timing of the Transmitter data bus according to the interface selected.
When in UTOPIA mode and not configured for external FIFOs (EXTFIFO is
LOW), TXEN*, RXEN* and all FIFO flags are active LOW. In this mode the
active data transition for the transmit data bus is within the same clock as the
transmit interface is selected by TXEN*.
When configured for Cascade mode where the CY7C924ADX device is
cascaded with external FIFOs (EXTFIFO is HIGH), TXEN, RXEN, the Full and
Empty FIFO flags are active HIGH (the Half-full flag is always active LOW).
TXEN is driven by the empty flag of an attached CY7C42X5 FIFO, and RXEN
is driven by the Almost Full flag of an attached CY7C42X5 FIFO. In this mode
the active data transition for the transmit data bus is in the clock cycle following
the clock edge where transmit interface is selected by TXEN*.
28
FIFOBYP*
Static control input
TTL levels Normally
wired HIGH or LOW
FIFO Bypass Select. When LOW, the Transmit and Receive FIFOs are
bypassed. In this mode TXCLK is not used. Instead all transmit data must be
synchronous to REFCLK. Transmit FIFO status flags are synchronized to
REFCLK. RXCLK becomes an output at the Receive PLL recovered character
clock rate. All received data and FIFO status flags are synchronized to
RXCLK.
When HIGH, the Transmit and Receive FIFOs are enabled. In this mode all
Transmit FIFO writes are synchronized to TXCLK, and all Receive FIFO reads
are synchronous to the RXCLK input.
27
ENCBYP*
Static control input
TTL levels Normally
wired HIGH or LOW
Encoder Bypass Select. When LOW, both the encoder and decoder are
bypassed. Data transmits in NRZ format, without encoding, LSB first.
Received data are presented to the interface as parallel characters without
decoding.
When HIGH, data passes through both the 8B/10B encoder in the Transmit
path and the decoder in the Receive path.
24, 25
RXMODE[1:0]
Static control input
TTL levels Normally
wired HIGH or LOW
Receive Discard Policy Select. These inputs select among the four data
handling and fill-character discard modes in the receiver. See Table 7 on page
23.
Document #: 38-02008 Rev. *E
Page 10 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
Name
I/O Characteristics
Signal Description
50
BYTE8/10*
Static control input
TTL levels Normally
wired HIGH or LOW
Parallel Data Character Size Select. Selects the input data character width.
When BYTE8/10* is HIGH and ENCBYP* is HIGH, the device is in 8 bit mode
and the data is encoded using the 8B/10B code rules found in Table 11 on
page 51 and Table 12 on page 55. When BYTE8/10* is HIGH and ENCBYP*
is LOW, the 10 parallel data bits pass directly to or from the serial stream
without encoding or decoding.
When BYTE8/10* is LOW, the part is in 10 bit mode. If the encoder is enabled
(ENCBYP* is HIGH), the part passes the 10 parallel bits to the byte stuffer and
encoder. When the encoder is disabled (ENCBYP* is LOW), the 12 parallel
data bits pass directly to or from the serial stream without encoding or
decoding.
For affected pin groupings and function see Table 1 on page 13 and Table 8
on page 25.
If the FIFOs are BYPASSED and Encoding is enabled (FIFOBYP* = LOW and
ENCBYP* = HIGH), BYTE8/10* MUST BE HIGH.
52, 51
RESET*[1:0]
TTL input,
Global Logic Reset. These inputs are pulsed LOW for one or more REFCLK
periods to reset the internal logic. They must be tied together or driven concurrently to ensure a valid reset.
1
TEST*
TTL input,
Factory Test Mode Select. Used to force the part into a diagnostic test mode
asynchronous.
for factory ATE test. This pin is tied HIGH during normal operation.
Normally wired HIGH
Analog I/O and Control
89, 90,
81, 82
OUTA±
OUTB±
PECL-compatible
differential outputs
Differential Serial Data Outputs. These PECL-compatible outputs are
capable of driving terminated transmission lines or commercial fiber optic
transmitter modules. An unused output pair may be powered down by leaving
the outputs unconnected and strapping the associated CURSETx pin to VDD.
97
CURSETA
Analog input
Current-set Resistor Input for OUTA±. A precision resistor is connected
between this input and a clean ground to set the output differential amplitude
and currents for the OUTA± differential driver.
78
CURSETB
Analog input
Current-set Resistor Input for OUTB±. A precision resistor is connected
between this input and a clean ground to set the output differential amplitude
and currents for the OUTB± differential driver.
94, 93,
86, 85
INA±
INB±
PECL-compatible
differential inputs
Differential Serial Data Inputs. These inputs accept the serial data stream
for deserialization and decoding. Only one serial stream at a time may be fed
to the receiver PLL to extract the data content. This stream is selected using
the A/B* input. These inputs may also be routed to the OUTB± serial outputs
using the DLB[1:0] inputs.
2
A/B*
TTL input,
asynchronous,
Internal Pull Up
Receive Data Input Selector. Determines which external serial bit stream is
passed to the receiver clock and data recovery circuit.
4,5
DLB[1:0]
TTL input,
asynchronous,
Internal Pull Down
Loopback Select Inputs. Selects connections between serial inputs and
outputs. Controls diagnostic loopback and serial loopthrough functions. See
Table 3 on page 17 for details.
100
CARDET
PECL-compatible
input, asynchronous
Carrier Detect Input. Allows an external device to signify that a valid signal
is being presented to the high speed PECL-compatible input buffers, as is
typical on an Optical Module. When CARDET is deasserted LOW, the LFI*
indicator asserts LOW signifying a Link Fault. This input can be tied to VDD for
copper media applications.
Document #: 38-02008 Rev. *E
Page 11 of 58
CY7C924ADX
Pin Descriptions (continued)
CY7C924ADX HOTLink Transceiver
Pin
Number
3
Name
LFI*
I/O Characteristics
Signal Description
TTL output, changes Link Fault Indication Output. Active LOW. LFI* changes synchronous with
following RXCLK↑
RXCLK. This output is driven LOW when the serial link currently selected by
A/B* is not suitable for data recovery. This can be caused by
• Serial Data Amplitude below acceptable levels.
• Input transition density not sufficient for PLL clock recovery.
• Serial Data stream outside an acceptable frequency range of operation.
• CARDET LOW.
Power
80, 87,
88, 95,
96, 98
VDDA
Power for PECL-compatible I/O signals and internal analog circuits.
76, 79,
83, 84,
91, 92,
99
VSSA
Ground for PECL-compatible I/O signals and internal analog circuits.
14, 17,
35, 55,
62, 64
VDD
Power for CMOS I/O signals and internal logic circuits.
11, 13,
15, 26,
37, 38,
39, 57,
63, 66
VSS
Ground for CMOS I/O signals and internal logic circuits.
CY7C924ADX HOTLink Operation
Transmit Data Path
Overview
Transmit Data Interface/Transmit Data FIFO
The CY7C924ADX is designed to move parallel data across
both short and long distances with minimal overhead or host
system intervention. To accomplish this it converts the parallel
characters into a serial bit stream, transmits these serial bits
at high speed, and converts the received serial bits back into
the original parallel data format.
The transmit data interface to the host system is configurable
as either an asynchronous buffered (FIFOed) parallel interface
or as a synchronous pipeline register. The bus itself can be
configured for operation with 8 bit, 10 bit or 12 bit data.
The CY7C924ADX offers a large feature set, so it can be used
in a wide range of host systems. Some of the configuration
options are:
• 8 bit, 10 bit or 12 bit character size
• User definable data packet or frame structure
• Two octave data rate range
• Asynchronous (FIFOed) or synchronous data interface
• 8B/10B encoded or nonencoded (raw data)
• Embedded or bypassable FIFO data storage
• Multi-PHY capability
• Point-to-point, point-to-multipoint, or ring data transport
This flexibility allows the CY7C924ADX to meet the data
transport needs of almost any system.
Document #: 38-02008 Rev. *E
When configured for asynchronous operation (where the
host-bus interface clock operates asynchronous to the serial
character and bit stream clocks), the host interface becomes
that of a synchronous FIFO clocked by TXCLK. In these
configurations an internal 256 character Transmit FIFO is
enabled. It allows the host interface to be written at any rate
from DC to 50 MHz.
When configured for synchronous operation, the transmit
interface is clocked by REFCLK and operates synchronous to
the internal character and bit stream clocks. The input register
must be written at the character rate, but REFCLK can operate
at one, two or four times the character rate.
Both asynchronous and synchronous interface operations
support two interface timing models: UTOPIA and Cascade.
The UTOPIA timing model is designed to match the active
levels, bus timing, and signal sequencing called out in the ATM
Forum UTOPIA specification. The Cascade timing model is
designed to match a host bus that resembles a synchronous
FIFO. These timing models allow the CY7C924ADX to directly
couple to host systems, registers, state machines, FIFOs, and
so on, with minimal and in many cases no external glue logic.
Page 12 of 58
CY7C924ADX
Encoder
Data from the host interface or Transmit FIFO is next passed
to an encoder block. The CY7C924ADX contains an internal
8B/10B encoder that is used to improve the serial transport
characteristics of the data. For systems that contain their own
encoder or scrambler, this encoder may be bypassed.
Serializer/Line Driver
The data from the encoder is passed to a serializer. This
serializer operates at either 2.5, 5, or 10 times the rate of the
REFCLK input (or 3, 6, or 12 times when BYTE8/10* and
ENCBYP* are LOW). The serialized data is output from two
PECL-compatible differential line drivers configured to drive
transmission lines or optical modules.
Receive Data Path
Line Receiver/Deserializer/Framer
Serial data is received at one of two PECL-compatible differential line receivers. The data is passed to both a Clock and
Data Recovery PLL (Phase Locked Loop) and to a deserializer
that converts serial data into parallel characters. The framer
adjusts the boundaries of these characters to match those of
the original transmitted characters.
Decoder
The parallel characters pass through a 10B/8B Decoder and
return to their original form. For systems that use external
decoding or descrambling, the decoder may be bypassed.
Receive Data Interface/Receive Data FIFO
Data from the decoder passes either to a Receive FIFO or
directly to the output register. The output register can be
configured for operation with 8 bit, 10 bit or 12 bit data
When configured for an asynchronous buffered (FIFOed)
interface, the data passes through a 256-character Receive
FIFO that allows data to be read at any rate from DC to
50 MHz. When configured for synchronous operation
(Receive FIFO is bypassed) data is clocked out of the Receive
Output register at the byte rate, up to 20 MHz. The receive
interface is also configurable for both UTOPIA and Cascade
timing models.
Table 1. Transmit Input Bus Signal Map
Transmit Encoder Mode[1]
Encoded 8-bit
Character Stream
Pre-encoded 10-bit
Character Stream
Encoded 10-bit
Character Stream
Pre-encoded 12-bit
Character Stream
ENCBYP*
HIGH
LOW
HIGH
LOW
BYTE8/10*
HIGH
HIGH
LOW
LOW
TXDATA Bus Input Bit
TXSC/D*
TXSC/D*
TXDATA[0]
TXD[0]
TXD[0][2]
TXD[0]
TXD[0][2]
TXDATA[1]
TXD[1]
TXD[1]
TXD[1]
TXD[1]
TXDATA[2]
TXD[2]
TXD[2]
TXD[2]
TXD[2]
TXDATA[3]
TXD[3]
TXD[3]
TXD[3]
TXD[3]
TXDATA[4]
TXD[4]
TXD[4]
TXD[4]
TXD[4]
TXDATA[5]
TXD[5]
TXD[5]
TXD[5]
TXD[5]
TXDATA[6]
TXD[6]
TXD[6]
TXD[6]
TXD[6]
TXDATA[7]
TXD[7]
TXD[7]
TXD[7]
TXD[7]
TXINT/TXDATA[8]
(FIFOBYP* = HIGH)
TXINT
TXD[8]
TXD[8]
TXD[8]
TXD[8]
TXD[8]
TXD[8]
TXD[9]
TXD[9]
TXD[9]
TXD[9]
TXD[9]
TXD[9]
TXINT/TXDATA[8]
(FIFOBYP* = LOW)
TXHALT*/TXDATA[9]
(FIFOBYP* = HIGH)
TXHALT*
TXHALT*/TXDATA[9]
(FIFOBYP* = LOW)
TXSC/D*
TXSVS/TXDATA[10]
TXSVS
TXSVS
TXD[10]
TXSOC/TXDATA[11]
(FIFOBYP* = HIGH)
TXSOC
TXSOC
TXD[11]
TXSOC/TXDATA[11]
(FIFOBYP* = LOW)
TXD[11]
Notes
1. All open cells are ignored.
2. First bit shifted out. Others follow in numerical order creating an NRZ pattern.
Document #: 38-02008 Rev. *E
Page 13 of 58
CY7C924ADX
CY7C924ADX HOTLink Transceiver Block
Diagram Description
Transmit Input/Output Register
The Transmit Input Register, shown in Figure 2, captures the
data to be processed by the HOTLink Transmitter, and allows
the input timing to be compatible with asynchronous or
synchronous host system buses. These buses can take the
form of UTOPIA compliant interfaces, external FIFOs, state
machines, or other control structures. Data present on the
TXDATA[11:0] and TXSC/D* inputs are captured at the rising
edge of the selected sample clock. The transmit data bus bit
assignments vary depending on the data encoding, and bus
width selected. These bus bit assignments are shown in
Table 1 on page 13, and list the functional names of these
different signals. Note that the function of several of these
signals changes in different operating modes. The logical
sense of the enable and FIFO flag signals depends on the
intended interface convention and is set by the EXTFIFO pin.
Figure 2. Transmit Input Register
TXDATA[11:0]
REFCLK
TXEN*
AM*
TXSC/D*
TXCLK
12
UTOPIA Timing Model
The UTOPIA timing model allows multiple CY7C924ADX
transmitters to be addressed and accessed from a common
host bus, using the protocols defined in the ATM Forum
UTOPIA interface standards. To enable it, set EXTFIFO LOW.
In UTOPIA timing, the TXEMPTY* and TXFULL* outputs and
TXEN* input, are all active LOW signals. If the CY7C924ADX
is addressed by AM*, it is “selected” when TXEN* is asserted
LOW. Following selection, data is written into the Transmit
FIFO on every clock TXCLK cycle where TXEN* remains
LOW.
Cascade Timing Model
The Cascade timing model is a variation of the UTOPIA timing
model. Here the TXEMPTY* and TXFULL* outputs, and TXEN
input, are all active HIGH signals. Cascade timing uses the
same address and selection sequences as UTOPIA timing,
but write data accesses use a delayed write. This delayed
write is necessary to allow direct coupling to external FIFOs,
or to state machines that initiate a write operation one clock
cycle before the data is available on the bus. To enable
Cascade timing, set EXTFIFO HIGH.
When used for FIFO depth expansion, Cascade timing allows
the size of the internal Transmit FIFO to be expanded to an
almost unlimited depth. It makes it possible to attach a
CY7C42x5 series synchronous FIFO to the transmit interface
without any extra logic, as shown in Figure 3.
Figure 3. External FIFO Depth Expansion of the
CY7C924ADX Transmit Data Path
Transmit Input Register
14
FF*
WEN*
To Encoder
Block
Transmit FIFO
Synchronous Interface
Synchronous interface clocking operates the entire transmit
data path synchronous to REFCLK. To enable it, connect
FIFOBYP* LOW to disable the internal FIFOs.
Asynchronous Interface
Asynchronous interface clocking controls the writing of host
bus data into the Transmit FIFO. To enable it, set FIFOBYP*
HIGH to enable the internal FIFOs. In these configurations,
TXCLK controls all writes to the Transmit Input Register and
associated transfers to the Transmit FIFO. The data is clocked
out of the Transmit FIFO and through the rest of the device on
REFCLK or a synthesized derivative of REFCLK.
Document #: 38-02008 Rev. *E
WEN*
D
TXCLK
The transmit interface supports both synchronous and
asynchronous clocking modes, each supporting both UTOPIA
(EXTFIFO = LOW) and Cascade (EXTFIFO = HIGH) timing
models. The selection of the specific clocking mode is determined by the RANGESEL and SPDSEL inputs and the FIFO
Bypass (FIFOBYP*) signal.
CY7C924ADX
CY7C42x5 FIFO
FF*
D
TXEN
EF*
TXFULL
REN*
TXDATA
TXSC/D*
Q
TXCLK
WCLK RCLK
“1”
EXTFIFO
Transmit FIFO
The Transmit FIFO buffers data captured in the input register
for later processing and transmission. This FIFO holds 256
14-bit characters. When the Transmit FIFO is active, and a
Transmit FIFO write is enabled (the device is selected through
AM* and TXEN* is sampled asserted), data and command are
captured in the transmit input register and stored in the
Transmit FIFO. TXCLK clocks all Transmit FIFO write operations.
The Transmit FIFO presents Full, Half-Full, and Empty FIFO
flags. These flags are provided synchronous to TXCLK. When
the Transmit FIFO is enabled, it allows operation with a
Moore-type external controlling state machine. When
configured for Cascade timing, the timing and active levels of
these signals also support direct expansion to Cypress
CY7C42x5 synchronous FIFOs.
Page 14 of 58
CY7C924ADX
The read port of the Transmit FIFO is connected to a logic
block that performs data formatting and validation. All data
read operations from the Transmit FIFO are controlled by a
Transmit Control State Machine that operates synchronous to
REFCLK.
Transmit Formatter and Validation
The Transmit Formatter and validation logic perform two
primary functions:
• Data format control
• Byte-packing
In addition to these logic functions, this block also controls the
timing for the transfer of data from the Transmit Input Register,
Transmit FIFO, or Elasticity Buffer.
Transmit Data Formatting
The CY7C924ADX supports a number of protocol enhancements over a raw physical layer device. These enhancements
are possible in part through the use of the Transmit and
Receive FIFOs. These FIFOs allow the CY7C924ADX to
manage the data stream to a much greater extent than was
possible before. In addition to the standard 8B/10B encoding
used to improve serial data transmission, the CY7C924ADX
also supports:
• Marking of packet or cell boundaries using TXSOC
• An expanded command set
• Ability to address and route packets or frames to specific
receivers
All three of these capabilities are supported for both 8 and 10
bit encoded character sizes, and are made possible by using
the TXSOC bit. This bit is interpreted, along with TXSC/D* and
TXSVS, in modes where both the Transmit FIFO and the
Encoder are enabled. All three bits determine how the data
associated with them is processed for transmission. These
operations are listed in Table 2.
The entries in Table 2 where TXSOC is LOW generate the
same characters in the serial data stream as a standard
CY7B923 HOTLink Transmitter. The data, command, and
exception character encodings are listed in the Data and
Special Character code tables (Table 11 on page 51 and
Table 12 on page 55) found near the end of this data sheet.
TXSOC
TXSC/D*
TXSVS
Table 2. Transmit Data Formatting
0
0
0
0
1
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
1
1
Data Format Operation
Normal Data Encode
Replace Character with C0.7 Exception
Normal Command Encode
Replace Character with C0.7 Exception
Send Start of Cell Marker (C8.0) + Data Character
Replace Character with C0.7 Exception
Send Extended Command Marker (C9.0) + Data
Character
1 Send Serial Address Marker (C10.0) + Data
Character
Document #: 38-02008 Rev. *E
The 001b, 011b, and 101b character formats instruct the
encoder to discard the associated data character and to
replace it with a C0.7 Exception character.
Excepting the previous 101b case, when the TXSOC bit read
from the Transmit FIFO is HIGH, an extra character is inserted
into the data stream. This extra character is always a Special
Character code (see Table 12 on page 55) that informs the
remote receiver that the immediately following character
should be interpreted differently from its normal meaning. The
associated character present on TXDATA[x:0] is always
encoded as a data character.
The 100b combination (TXSOC = 1, TXSC/D* = 0, and
TXSVS = 0) is used as a marker for the start of a cell, frame,
or packet of data being sent across the interface. When a
character is read from the Transmit FIFO with this combination
of bits set, a C8.0 Special Character code is sent to the
encoder before sending the associated data character.
The 110b character format expands the command space
beyond that available with the default 8B/10B code. The
8B/10B code normally supports a data space of 256 data
characters, and a command (non-data) space of twelve
command characters (C0.0–C11.0 in Table 12). For data links
where this is not sufficient, the 110b format can be used to
mark the associated data as an extended command. This
expands the command space to 256 commands (in addition to
some of the present twelve). When a character is read from
the Transmit FIFO with these bits set, a C9.0 Special
Character code is sent to the encoder before sending the data
character.
The 111b character format sends serial addresses to attached
receivers. These serial addresses allow a host to direct (the
following) data to a specific destination or destinations, when
the CY7C924ADX devices are connected in a ring or bus
topology.
The Serial Address marker may also be used to send packet
identification fields, sequence numbers, or other high level
routing information for those point-to-point connections that do
not require physical address capabilities. However, the
reporting of the address field contents may be affected by the
present receiver discard policy. This marking or tagging can be
performed with the 100b or 110b character formats without
concern for receiver discard policy.
When a character is read from the Transmit FIFO with these
bits set, a C10.0 Special Character is sent to the encoder
before sending the associated data character.
Byte Packer
The byte packer is a logical construct that controls the efficient
segmentation of 10 bit source data into 8 bit characters. This
conversion allows these characters to be transported using
8B/10B encoding, with the same encoding overhead (20%) as
when sending 8 bit characters. Because the serializer
continues to operate using 10 bit transmission characters, this
encoding mode only operates with the Transmit FIFO enabled.
The byte packer takes pieces of one or more 10 bit characters,
combines them into 8-bit groups, and passes these groups to
the 8B/10B encoder. It takes exactly five 8 bit characters to
transport four 10 bit characters. The allocation is performed,
as shown in Figure 4 on page 16, where the low order eight
bits of the first 10 bit character (A[7:0]) are passed to the
Page 15 of 58
CY7C924ADX
encoder on the first clock cycle. During the second clock cycle
the remaining two bits of the first character are combined with
the lower six bits of the second 10 bit character (B[5:0]+A[9:8]).
In the third clock cycle the remaining four bits of the second 10
bit character are combined with the lower four bits of the third
10 bit character (C[3:0]+B[9:6]). In the fourth clock cycle the
remaining six bits of the third 10 bit character are combined
with the lower two bits of the fourth 10 bit character
(D[1:0]+C[9:4]). In the fifth clock cycle the remaining eight bits
of the fourth 10 bit character are passed to the encoder
(D[9:2]).
This process repeats for additional data characters present in
the FIFO. If at any time the Transmit FIFO is emptied, and a
portion of a 10 bit character has not yet been transmitted, the
remaining bits of the 8 bit character are filled with dummy bits
before that character is passed to the encoder. The 8 bit
character containing these dummy bits is immediately
followed by a C5.0 (K28.5) fill character, which resets the
sequencer boundaries to the first character position.
Figure 4. Byte-Packer 10-to-8 Character Mapping
Source 10-bit Character Stream
DDDDDDDDDD
9876543210
CCCCCCCCCC
9876543210
BBBBBBBBBB
9876543210
AAAAAAAAAA
9876543210
all Data and Special Character codes, including the explicit
violation symbols. This provides a predictable but
pseudo-random sequence that can be matched to an identical
LFSR in the Receiver.
The specific patterns generated are described in detail in the
Cypress application note “HOTLink Built-In Self-Test.” The
sequence generated by the CY7C924ADX is identical to that
in the HOTLink CY7B923 and HOTLink II family
CYP(V)15G0x0x, allowing the user to build interoperable
systems when the devices are used at compatible serial
signaling rates.
Encoder
The data passed through the Transmit FIFO and formatter, or
as received directly from the Transmit Input Register, is
seldom in a form suitable for transmission across a serial link.
The characters must usually be processed or transformed to
guarantee:
• A minimum transition density (to allow the serial receiver
PLL to extract a clock from the data stream)
• A DC balance in the signaling (to prevent baseline wander)
• Run length limits in the serial data (to limit the bandwidth of
the link)
• A way to allow the remote receiver to determine the correct
character boundaries (framing).
The CY7C924ADX contains an integrated 8B/10B encoder
that accepts 8 bit data characters and converts these into 10
bit transmission characters that have been optimized for
transport on serial communications links. The 8B/10B encoder
can be bypassed for those system that operate with external
8B/10B encoders, or use alternate forms of encoding or
scrambling to ensure good transmission characteristics. The
operation of the 8B/10B encoding algorithm is described in
detail later in this data sheet, and the complete encoding
tables are listed in Table 11 on page 51 and Table 12 on page
55.
DDDDDDDD
98765432
DDCCCCCC
10987654
CCCCBBBB
32109876
BBBBBBAA
54321098
AAAAAAAA
76543210
Encoder Block
When the Encoder is enabled, the transmit data characters (as
passed through the Transmit FIFO and formatter) are
converted to either a 10 bit Data symbol or a 10 bit Special
Character, depending upon the state of the TXSC/D* input. If
TXSC/D* is HIGH, the data inputs represent a Special
Character code and are encoded using the Special Character
encoding rules in Table 12. If TXSC/D* is LOW, the data inputs
are encoded using the Data Character encoding in Table 11.
The Encoder logic block performs two primary functions:
encoding the data for serial transmission and generating BIST
(Built-In Self-Test) patterns to allow at speed link and device
testing.
If TXSVS is HIGH, the respective character is replaced with an
SVS (C0.7) character. This can be used to check error
handling system logic in the receiver controller or for proprietary applications.
BIST LFSR
The 8B/10B encoder is compliant with ANSI/NCITS ASC
X3.230-1994 (Fibre Channel), IEEE 802.3z (Gigabit Ethernet),
the IBM ESCON and FICON channels, and ATM Forum
standards for data transport.
Last
Character
Sent
First
Character
Sent
The Encoder logic block operates on data stored in a register.
This register accepts information directly from the Transmit
FIFO, the Transmit Input Register, the 10/8 Byte Packer, or
from the Transmit Control State Machine when it inserts
special characters into the data stream.
This same register is converted into a Linear Feedback Shift
Register (LFSR) when the Built-In Self-Test (BIST) pattern
generator is enabled (TXBISTEN* is LOW). When enabled,
this LFSR generates a 511-character sequence that includes
Document #: 38-02008 Rev. *E
The 8B/10B coding function of the Encoder can be bypassed
for systems that include an external coder or scrambler
function as part of the controller or host system. Do this by
setting ENCBYP* LOW. With the encoder bypassed, each
10 bit or 12 bit character (as captured in the Transmit Input
Register) passes directly to the Transmit Shifter (or Transmit
FIFO) without modification.
Page 16 of 58
CY7C924ADX
Transmit Shifter
The Transmit Shifter accepts 10 bit or 12 bit parallel data from
the Encoder block once each character time, and shifts it out
the serial interface output buffers using a PLL-multiplied bit
clock. This bit clock runs at 2.5, 5, or 10 times the REFCLK
rate (3, 6, or 12 times when BYTE8/10* and ENCBYP* are
LOW) as selected by RANGESEL and SPDSEL (see Table 4
on page 18). The counter and dividers in the Clock Multiplier
PLL control timing for the parallel transfer, which is not affected
by signal levels or timing at the input pins.
Bits in each character shift out LSB first, as required by ANSI
and IEEE standards for 8B/10B coded serial data streams.
Table 3. Transmit Data Routing Matrix
DLB[1] DLB[0]
0
0
TRANSMIT
SHIFTER
OUTB
INB
RECEIVE
PLL
INA
0
1
TRANSMIT
SHIFTER
For more details on these and LOOPTX reclocking options,
see “Serial Line Receivers” on page 20.
Serial Line Drivers
The serial interface PECL compatible Output Drivers (ECL
referenced to +5V) are the transmission line drivers for the
serial media. OUTA± receives its data directly from the
transmit shifter, while OUTB± receives its data from the
Routing Matrix. These two outputs (OUTA± and OUTB±) can
connect directly to +5V optical modules, and can also directly
drive DC or AC coupled transmission lines.
The PECL compatible Output Drivers can be viewed as
programmable current sources. The output current and the
load impedance ZLOAD determine the output voltage. The
desired output voltage swing is therefore controlled by the
current set resistor RCURSET associated with that driver.
Different RCURSET values are required for different line
impedance/amplitude combinations. The output swing is
designed to center around VDD − 1.33V. Each output must be
externally biased to VDD − 1.33V.
When the interconnect and load are viewed as a differential
transmission line, the absolute voltage VODIF and the differential load impedance are used to calculate the value of
RCURSET. This amplitude relationship is controlled by the load
impedance on the driver, and by the resistance of the RCURSET
resistor for that driver, as listed in Equation 1.
Document #: 38-02008 Rev. *E
OUTA
A/B*
OUTB
INB
RECEIVE
PLL
INA
1
0
TRANSMIT
SHIFTER
The level restored (10b) and reclocked (11b) settings make
use of one of the transmit data outputs. When configured for
level restored or reclocked data, the selected input is retransmitted on OUTB±. The level restored connection simply
buffers the input signal allowing a “bus like” connection to be
constructed without concern for multidrop PECL compatible
signal layout issues.
The reclocked connection buffers a PLL filtered copy of the
selected input data stream. This removes most of the high
frequency jitter that accumulates on a signal when sent over
long transmission lines. Because the retransmitted data is
clocked by the recovered clock, the data can suffer from jitter
peaking when communicated through several PLLs.
OUTA
A/B*
Routing Matrix
The Routing Matrix is a set of precision multiplexers that allow
various combinations of Transmit Shifter, buffered INA± or
INB± serial line receiver inputs, or a reclocked serial line
receiver input to be transmitted from the OUTB± serial data
outputs. The signal routing for the transmit serial outputs is
controlled primarily by the DLB[1:0] inputs as listed in Table 3
Data Connections
OUTA
A/B*
OUTB
INB
RECEIVE
PLL
INA
1
1
TRANSMIT
SHIFTER
OUTA
A/B*
OUTB
INB
RECEIVE
PLL
INA
90 × Z LOAD
R CURSET = ----------------------------V ODIF
Eq. 1
In Equation 1, VODIF is the difference in voltage levels at one
output of the differential driver when that output is driving HIGH
and LOW, ZLOAD is the differential load between the true and
complement outputs of the driver. With a known load
impedance and a desired signal swing, it is possible to
calculate the value of the associated CURSETA or CURSETB
resistor that sets this current.
Unused differential output drivers must be left open, and can
reduce their power dissipation by connecting their respective
CURSETx input to VDD.
Transmit PLL Clock Multiplier
The Transmit PLL Clock Multiplier accepts an external clock at
the REFCLK input, and multiples that clock by 2.5, 5, or 10 (3,
6, or 12 when BYTE8/10* is LOW and the encoder is disabled)
to generate a bit rate clock for use by the transmit shifter. It
also provides a character rate clock used by the Transmit
Controller state machine.
The clock multiplier PLL can accept a REFCLK input between
8.33 MHz and 40 MHz, however, this clock range is limited by
Page 17 of 58
CY7C924ADX
the operation mode of the CY7C924ADX as selected by the
SPDSEL and RANGESEL inputs, and to a limited extent, by
the BYTE8/10*, ENCBYP* and FIFOBYP* signals. Table 4
shows the SPDSEL and RANGESEL for the case where the
FIFOs and encoding are enabled. Table 5 provides the multiplier factors and clocking ranges for various combinations of
signals.
Table 4. Speed Select and Range Select Settings, FIFOs
and Encoding enabled
RANGESEL
Serial
Data Rate
(MBaud)
LOW
LOW
50–100
10–20
LOW
HIGH
50–100
20–40
HIGH
LOW
100–200
10–20
HIGH
HIGH
100–200
20–40
SPDSEL
REFCLK
Frequency
(MHz)
Transmit Control State Machine
The Transmit Control State Machine responds to multiple
inputs to control the data stream passed to the encoder. It
operates in response to:
• The state of the FIFOBYP* and LOOPTX inputs
• The state of the TXINT input
• The presence of data in the Transmit FIFO
Document #: 38-02008 Rev. *E
•
•
•
•
The contents of the Transmit FIFO
The contents of the Elasticity Buffer
The state of the transmitter BIST enable (TXBISTEN*)
The state of external halt signals (TXHALT* and TXSTOP*)
These signals are used by the Transmit Control State Machine
to control the data formatter, read access to the Transmit FIFO
and Elasticity Buffer, the Byte-Packer, and BIST. They
determine the content of the characters passed to the Encoder
and Transmit Shifter.
When the Transmit FIFO is bypassed, the Transmit Control
State Machine operates synchronous to REFCLK. In this
mode, data from the TXDATA bus (or other source) passes
directly from the Input Register to the Pipeline Register. If no
data is enabled into the Input register (TXEN* is deasserted)
then the Transmit Control State Machine presents a C5.0
Special Character code to the Encoder to maintain link
synchronization. If both the Encoder and Transmit FIFO are
bypassed and no data is enabled into the Input Register, the
Transmit Control State Machine injects an alternating disparity
sequence of preencoded (10 bit) forms of the C5.0 characters.
This also occurs if the encoder is bypassed, the Transmit FIFO
is enabled, and the Transmit FIFO is empty. However, since
disparity tracking is part of the Encoder, the transmitted C5.0
characters may generate a running disparity error at the
remote receiver. If the attached receiver has its decoder
enabled, these characters may be reported as a normal C5.0,
or as a C1.7 or C2.7 (K28.5 with incorrect running disparity).
Page 18 of 58
CY7C924ADX
Table 5. Speed Select and Range Select Settings, all modes
BYTE8/10*
ENCBYP*
SPDSEL
REFCLK
Frequency
(MHz)
Serial Data Rate
(MBd)
LOW
10-20
50-100
x5
HIGH
20-40
50-100
x2.5
LOW
10-20
100-200
x10
HIGH
20-40
100-200
x5
LOW
10-20
50-100
x5
HIGH
20-40
50-100
x2.5
LOW
10-20
100-200
x10
HIGH
20-40
100-200
x5
LOW
8.33-16.67
50-100
x6
HIGH
16.67 -33.33
50-100
x3
LOW
8.33-16.67
100-200
x12
HIGH
16.67 -33.33
100-200
x6
RANGESEL
FIFOBYP*
LOW
HIGH
X
HIGH
LOW
HIGH
HIGH
HIGH
LOW
LOW
LOW
HIGH
LOW
HIGH
X
HIGH
LOW
HIGH
LOW
HIGH
LOW
LOW
LOW
HIGH
External Control of Data Flow
The Transmit Control State Machine supports three different
types of external control:.
• TXSTOP*
• TXHALT*
• TXINT
These control signal inputs are only interpreted when the
Transmit FIFO is enabled. They affect the transmission of data
by bringing external signals to the state machine without
sending the signals through the Transmit FIFO.
TXSTOP* stops transmission of the next packet or cell of data
in the Transmit FIFO. When asserted (LOW) the Transmit
Control State Machine continues to read and process
characters in the Transmit FIFO until a location is read with the
TXSOC bit set. Once a TXSOC is detected, the state machine
sends out C5.0 fill characters until TXSTOP* is deasserted
(HIGH) for one or more character times. When TXSTOP* is
sampled deasserted it allows the next character with TXSOC
set to be read from the Transmit FIFO and passed to the
Encoder.
Document #: 38-02008 Rev. *E
Multiplier
Factor
LOW
10-20
50-100
x5
HIGH
20-40
100-200
x5
LOW
10-20
100-200
x10
HIGH
20-40
100-200
x5
LOW
10-20
50-100
x5
HIGH
20-40
100-200
x5
LOW
10-20
100-200
x10
HIGH
20-40
100-200
x5
LOW
8.33-16.67
50-100
x6
HIGH
16.67 -33.33
100-200
x6
LOW
8.33-16.67
100-200
x12
HIGH
16.67 -33.33
100-200
x6
When TXSTOP* controls the flow of data, it is asserted (LOW)
most of the time. To allow a cell or frame to pass, it only needs
to be deasserted (HIGH) for one TXCLK cycle (assuming the
transmit controller is at a cell boundary). Once the first
character of the cell is transmitted the remainder of that cell is
also processed. This allows the host system to control the
transmission of data across the interface on a cell-by-cell or
packet-by-packet basis.
TXHALT* (TXDATA[9]) is an immediate form of TXSTOP*.
Instead of continuing to transmit data until a TXSOC is found,
asserting TXHALT* stops character processing at the next
FIFO character location. No additional data is read from the
Transmit FIFO until TXHALT* is deasserted (HIGH).
Note. If the Encoder is bypassed, TXDATA[9] is a data input
and not TXHALT*. Since in this mode the interface does not
interpret the TXSOC bit, the TXSTOP* signal assumes the
same functionality as TXHALT*.
TXINT is used to send one of two interrupt characters from the
local transmitter to a remote receiver. While it also bypasses
the Transmit FIFO, it does not directly stop data transmission.
The Transmit Control State Machine responds to transitions on
the TXINT input. When TXINT transitions from 0→1, a C0.0
Page 19 of 58
CY7C924ADX
(K28.0) Special Character code is inserted before the data
character with which TXINT is associated is sent. When TXINT
transitions from 1→0, a C3.0 (K28.3) Special Character code
is sent. The reception of these characters generates an equivalent action on the attached receiver’s RXINT status output.
The combination of RXHALF*, TXINT, RXINT, and TXHALT*
may be used to prevent a remote FIFO overflow, which would
result in lost data. This back pressure mechanism can significantly improve data integrity in systems that cannot guarantee
the full bandwidth of the host system at all times.
Elasticity Buffer
There is a short (8 character) FIFO between the receive and
transmit paths. This FIFO separates the time domains of the
received serial data stream and the outbound transmit data
stream. This permits retransmission of received data without
worry of jitter gain or jitter transfer. This allows error free transmission of the same data, when configured in daisy chain or
ring configurations, to an unlimited number of destinations.
This Elasticity Buffer is enabled when the LOOPTX input is
asserted HIGH. This directs the receiver to place all non-C5.0
(K28.5) characters into the Elasticity Buffer. LOOPTX also
directs the Transmit Control State Machine to read data from
the Elasticity Buffer instead of from the Transmit FIFO.
While retransmitting data from the Elasticity Buffer, the
Transmit FIFO is available to preload data to be transmitted.
Once LOOPTX is deasserted (LOW), normal data transmission from the Transmit FIFO resumes.
This LOOPTX capability is only possible when sending 8 bit
encoded data streams. It cannot be used with byte-packed or
nonencoded data streams, and requires that the Transmit and
Receive FIFOs are enabled. The receiver must also be
configured to process embedded commands (receiver
Discard Policy cannot be 0). The reclocked connection may be
required when sending non-8B/10B coded data streams, or
data streams that cannot tolerate the data forwarding policies
of the Elasticity Buffer.
Serial Line Receivers
Two differential line receivers, INA± and INB±, are available to
accept serial data streams, with the active input selected using
the A/B* input. The DLB[1:0] inputs allow the transmit
Serializer output to be selected as a third input serial stream,
but this path is generally used only for diagnostic purposes.
The serial line receiver inputs are all differential, and will
accommodate wire interconnect with filtering losses or transmission line attenuation greater than 9 dB (VDIFF > 200 mV, or
400 mV peak-to-peak differential) or can be directly connected
to +5V fiber optic interface modules (any ECL logic family, not
limited to ECL 100K). The common-mode tolerance of these
line receivers accommodates a wide range of signal termination voltages.
As can be seen in Table 3 on page 17, these inputs are
configured to allow single-pin control for most applications. For
those systems requiring selection of only INA± or INB±, the
DLB[1:0] signals can be tied LOW, and the A/B selection can
be performed using only A/B*. For those systems requiring
only a single input and a local loopback, the A/B* can be tied
HIGH or LOW, DLB[1] signal can be tied LOW and DLB[0] can
be used for loopback control.
Document #: 38-02008 Rev. *E
Signal Detect
The selected Line Receiver (that routed to the clock and data
recovery PLL) is simultaneously monitored for:
• Analog amplitude (>400 mVDIFF pk-pk)
• Transition density
• Received data stream outside normal frequency range
(±400 ppm)
• Detected carrier.
All of these conditions must be valid for the Signal Detect block
to indicate a valid signal is present. This status is presented on
the LFI* (Link Fault Indicator) output, which changes
synchronous to RXCLK. While link status is monitored internally at all times, it is necessary to have transitions on RXCLK
to allow this signal to change externally.
Clock/Data Recovery
The extraction of a bit rate clock and recovery of data bits from
the received serial stream is performed within the Clock/Data
Recovery (CDR) block. The clock extraction function is
performed by a high performance embedded phase locked
loop (PLL) that tracks the frequency of the incoming bit stream
and aligns the phase of its internal bit rate clock to the transitions in the serial data stream.
The CDR makes use of the clock present at the REFCLK input.
It ensures that the VCO (within the CDR) is operating at the
correct frequency (rather than some harmonic of the bit rate),
to improve PLL acquisition time, and to limit unlocked
frequency excursions of the CDR VCO when no data is
present at the serial inputs.
Regardless of the type of signal present, the CDR will attempt
to recover a data stream from it. If the frequency of the
recovered data stream is outside the limits for the range
controls, the CDR PLL will track REFCLK instead of the data
stream. When the frequency of the selected data stream
returns to a valid frequency, the CDR PLL is allowed to track
the received data stream. The frequency of REFCLK must be
within ±400 ppm of the frequency of the clock that drives the
REFCLK signal at the remote transmitter to ensure a lock to
the incoming data stream.
For systems using multiple or redundant connections, the LFI*
output can select an alternate data stream. When an LFI*
indication is detected, external logic can toggle selection of the
INA± and INB± inputs through the A/B* input. When a port
switch takes place, the PLL must reacquire the new serial
stream and frame the incoming characters.
Clock Divider
This block contains the clock division logic, used to transfer the
data from the Deserializer/Framer to the Decoder once every
character (once every ten or twelve bits) clock. This counter is
free running and generates outputs at the bit rate divided by
10 (12 when the BYTE8/10* and ENCBYP* are LOW). When
the Receive FIFO is bypassed, one of these generated clocks
is driven out the RXCLK pin.
Deserializer/Framer
The CDR circuit extracts bits from the serial data stream and
clocks these bits into the Shifter/Framer at the bit clock rate.
When enabled, the Framer examines the data stream looking
Page 20 of 58
CY7C924ADX
for C5.0 (K28.5) characters at all possible bit positions. The
location of this character in the data stream is used to
determine the character boundaries of all following characters.
The framer operates in one of three different modes, as
selected by the RFEN input. When RFEN is first asserted
(HIGH), the framer is allowed to reset the internal character
boundaries on any detected C5.0 character.
Random errors that occur in the serial data can corrupt some
data patterns into a bit pattern identical to a K28.5, and thus
cause an erroneous data-framing error. To prevent this, the
CY7C924ADX provides a multi-byte framer that is enabled
once RFEN has been HIGH for greater than 2048 character.
This requires two C5.0 characters within a span of five
characters, with both C5.0 characters located on identical
10-bit character boundary locations, before the framer is
allowed to reset the internal character boundary. This
multi-byte framing option greatly reduces the possibility of
erroneously reframing to an aliased K28.5 character.
If RFEN is LOW, the framer is disabled and no changes are
made to character boundaries.
The framer in the CY7C924ADX operates by shifting the
internal character position to align with the character clock.
This ensures that the recovered clock does not contain any
significant phase changes/hops during normal operation or
framing, and allows the recovered clock to be replicated and
distributed to other circuits using PLL-based logic elements.
Decoder Block
The decoder logic block performs two primary functions:
decoding the received transmission characters back into Data
and Special Character codes, and comparing generated BIST
patterns with received characters to permit at-speed link and
device testing.
10B/8B Decoder
The framed parallel output of the Deserializer is passed to the
10B/8B Decoder where, if the Decoder is enabled, it is transformed from a 10-bit transmission character back to the
original Data and Special Character codes. This block uses the
standard decoder patterns in Tables 11 and 12 of this data
sheet. Data patterns are indicated by a LOW on RXSC/D*, and
Special Character codes are indicated by a HIGH. Invalid patterns
or disparity errors are signaled as errors by a HIGH on RXRVS, and
by specific Special Character codes.
If the Decoder is bypassed and BYTE8/10* is HIGH, the ten
(10) data bits of each transmission character are passed
unchanged from the framer to the Pipeline Register.
When the Decoder is bypassed and BYTE8/10* is LOW, the
twelve (12) data bits of each transmission character are
passed unchanged from the framer to the Pipeline Register.
BIST LFSR
The output register of the Decoder block is normally used to
accumulate received characters for delivery to the Receive
Formatter block. When configured for BIST mode
(RXBISTEN* is LOW), this register becomes a signature
pattern generator and checker by logically converting to a
Linear Feedback Shift Register (LFSR). When enabled, this
Document #: 38-02008 Rev. *E
LFSR generates a 511-character sequence that includes all
Data and Special Character codes, including the explicit
violation symbols.
This provides a predictable but
pseudo-random sequence that can be matched to an identical
LFSR in the Transmitter. When synchronized with the received
data stream, it checks each character in the Decoder with each
character generated by the LFSR and indicates compare
errors at the RXRVS output of the Receive Output Register.
The LFSR is initialized by the BIST hardware to the BIST loop
start code of D0.0 (D0.0 is sent only once per BIST loop). Once
the start of the BIST loop has been detected by the receiver,
RXRVS is asserted for pattern mismatches between the
received characters and the internally generated character
sequence. Code rule violations or running disparity errors that
occur as part of the BIST loop do not cause an error indication.
RXFULL* pulses asserted for one RXCLK cycle per BIST loop and
can be used to check test pattern progress.
The specific patterns checked by the receiver are described in
detail in the Cypress application note “HOTLink Built-In
Self-Test.” The sequence compared by the CY7C924ADX is
identical to that in the HOTLink CY7B933 receiver and the
HOTLink II family of devices CYP(V)15G0x0x, allowing
interoperable systems to be built when used at compatible
serial signaling rates.
If a large number of errors are detected, the receive BIST state
machine aborts the compare operations and resets the LFSR
to the D0.0 state to look for the start of the BIST sequence
again.
Receive Formatter
The Receive Formatter performs three primary functions:
• Data formatting
• Address matching
• Byte-unpacking
Receive Data Formatting
The protocol enhancements of the transmit path are mirrored
in the receive path logic. The majority of these enhancements
require that the Receive FIFO be enabled to allow the
CY7C924ADX to manage the data stream. In addition to the
standard 10B/8B decoding used for character reception and
recovery, the CY7C924ADX also supports:
• Marking of packet or cell boundaries using RXSOC
• An expanded control/command character set
• Ability to accept or discard data based on an embedded
address
• The ability to filter receive data of non-essential information
All of these capabilities are supported for both 8- and 10-bit
character sizes, and are made possible through use of the
RXSOC bit. RXSOC is generated upon reception of the C8.0,
C9.0, or C10.0 Special Character codes, in those modes
where both the Receive FIFO and the Decoder are enabled.
The entries in Table 6 show how the RXSOC, RXSC/D*, and
RXRVS bits are formatted to indicate the reception of specific
characters and character combinations. Normal Data and
Special Character code characters are indicated by RXSOC
Page 21 of 58
CY7C924ADX
being LOW (0). This allows the standard Special Characters
codes to also be reported and output.
RXRVS
RXSC/D*
RXSOC
Table 6. Receive Data Formatting
Data Format Indication
This marker is treated internally the same as the 100b Start Of
Cell indication, which allows it to be used to mark the boundary
of any user-specific information. As a boundary or cell marker,
the immediately following data can be a data field, a header, a
stream identifier, a transaction number, a packet length
indicator, or any of a number of pieces of information
connected to a data transfer.
Note. In reality, the 100b and 110b indicators can be used
interchangeably; i.e., the 100b indication can be used to mark
extended commands while the 110b indication can be used to
mark the start of cells.
0
0
0 Normal Data Character
0
0
1 Reserved
0
1
0 Normal Command Character
0
1
1 Received C0.7 Exception Character or Other
Character Exception (as listed in Table 12)
1
0
0 Received Start of Cell Marker (C8.0) + Data
Character
1
0
1 Received Illegal Sequence
The 111b indication is used to mark the start of a Serial
Address field. Unlike the Start Of Cell and Extended Command
markers, which have no specific data-field length associated
with them, the associated Serial Address is always comprised
of the immediately following single data character, and
supports a fixed 8-bit or 10-bit address field format in 8-bit or
10-bit byte-packed data formats.
1
1
0 Received Extended Command Marker (C9.0) +
Data Character (interpreted as a command)
When this serial address is received it may be passed to the
Receive FIFO or discarded (see Table 7 on page 23).
1
1
1 Received Serial Address Marker (C10.0) + Data
Character (interpreted as an address)
Address Matching
Individual character errors that are not part of one of the
supported sequences (Start of Cell, Extended Command, or
Serial Address) are marked by the 011b (RXSOC = 0,
RXSC/D* = 1, and RXRVS = 1) decode status.
Anytime RXSOC is reported HIGH (1) at least one of the C8.0,
C9.0, or C10.0 characters was received as a valid character.
If the immediately following character is a valid Data character,
then the corresponding combination of RXSOC, RXSC/D*,
and RXRVS indicate the type of information received. If the
immediately following character is a Special Character code of
any type (even a C5.0), then a 101b is posted to indicate an
illegal sequence was received.
An illegal sequence can be caused by a remote transmitter
sending incorrect information, or by receiving data corrupted
during transmission. When such an error is detected, the 101b
status bits are posted and the associated data field is set to the
Special Character code that was received without error (C8.0,
C9.0, or C10.0 reported as D8.0, D9.0, or D10.0 along with the
101b status). This information is provided to assist in
debugging link or protocol faults.
The 100b indication is used to mark the associated Data
character as the first character of a new frame, packet, cell, or
other data construct used by the system. The Data characters
and Special Character codes that follow this marker are written
to the Receive FIFO (if the present address matching requirements are satisfied).
The 110b indication is used to mark the associated data
character as the first character of an extended command. In
reality there is no limit to the number of immediately following
data characters that can be considered part of this command.
The most common interpretation is based on the configured
bus width, such that single-character configurations support
the associated character as the extended command, providing
up to 256 extended commands for 8-bit data and 1024 for
10-bit byte-packed data.
Document #: 38-02008 Rev. *E
For those modes where address matching is enabled, the
CY7C924ADX’s ability to accept or discard data can be
controlled by the remote transmitter. This is often useful in
configurations with one or more data sources and multiple
data destinations.
Each CY7C924ADX contains an 8-bit or 10-bit Serial Address
Register that is compared with the first data character received
following a Serial Address marker (C10.0). This character
constitutes an address, which can be configured for one of two
modes for address matching. The first mode is used for
multicast addresses, where a bit-wise AND is performed on
each bit of the address character received, with the contents
of each of the bits in the Serial Address Register. If any of the
same bit locations in the register and the received data are
both set to ‘1’, a multicast address match is declared and the
following data and Special Character codes are interpreted
and passed to the Receive FIFO.
If the multicast address field is ever received as all 1s (FFh or
3FFh), the receiver always accepts the data. This all 1s setting
is the broadcast address and is used to send data to all
receivers.
This all 1s setting also has special meaning when written to
the Serial Address Register. When the multicast address field
is written to an all 1s (FFh or 3FFh) state, the receiver operates
in promiscuous mode, and receives all data, regardless of the
contents of any serial address commands received. This is
also the default or power-up state of the Serial Address
register.
The second mode of operation for address matching is when
the Serial Address register contains a unique device address,
and is compared with the character received following the
C10.0 Serial Address marker. This unicast address requires
an exact match between all 8 or 10 bits to declare a match
found and allow the following data to pass.
When the Elasticity Buffer is enabled, all received characters
(except C5.0) are written to the Elasticity Buffer, regardless of
the state or configuration of any present address match. This
Page 22 of 58
CY7C924ADX
allows one or more sources to send data to multiple receivers
with the receivers connected in a ring or daisy-chain topology.
By prefacing cells containing data with an address field, it is
possible to have each receiver only process data specifically
directed to it.
Byte-Unpacker
The Byte-Unpacker is used to reassemble 10-bit characters
from a received stream of decoded 8-bit characters. This
reassembly process is designed to allow transmission of the
same embedded commands, serial addresses, and Start of
Cell markers that are used with 8-bit data characters. Because
of the change in time per received encoded character versus
delivered 10-bit data character, this unpacking process is only
possible with the Receive FIFO enabled.
The byte-unpacker reverses the character segmentation
shown in Figure 4. It takes five data characters and combines
them into four 10-bit characters. This five-state unpacking
process is re-started by the detection of any Special Character
code in the Decoder, including the C5.0 (K28.5) fill character.
Since usage of the Elasticity Buffer inserts and deletes C5.0
characters (as necessary) to handle the speed differences
between the receive and transmit character clocks, it is not
possible to send byte-packed data through the Elasticity
Buffer. To send 10-bit packed data from one source to multiple
destinations it is necessary to either use a star topology of
interconnect, or make use of the buffered and reclocked serial
input-to-output connections controlled by the Routing Matrix.
Receive Control State Machine
The Receive Control State Machine responds to multiple input
conditions to control the routing and handling of received
characters. It controls the staging of characters across various
registers and the Receive FIFO. It also interprets all
embedded Special Character codes, and converts the appropriate ones to specific bit combinations in the Receive FIFO.
It controls the various discard policies and error control within
the receiver, and operates in response to:
• the received character stream
• the detection and validation of serial addresses
• the room for additional data in the Receive FIFO
• the state of the receiver BIST enable (RXBISTEN*)
• the state of LOOPTX
• the state of FIFOBYP*.
These signals and conditions are used by the Receive Control
State Machine to control the Receive Formatter, write access
to the Receive FIFO, write access to the Elasticity Buffer, the
Byte-Unpacker, the Receive Output register, and BIST. They
determine the content of the characters passed to each of
these destinations,
The Receive Control State Machine always operates
synchronous to the recovered character clock (bit-clock/10 or
bit-clock/12). When the Receive FIFO is bypassed, RXCLK
becomes an output that changes synchronous to the internal
character clock. RXCLK operates at the same frequency as
the internal character clock.
Discard Policies
When the Receive FIFO is enabled, the Receive Control State
Machine has the ability to selectively discard specific
characters from the data stream that are determined by the
present configuration as being unnecessary. When discarding
is enabled, it reduces the host system overhead necessary to
keep the Receive FIFO from overflowing and losing data.
The discard policy is configured as part of the operating mode
and is set using the RXMODE[1:0] inputs. The four discard
policies are listed in Table 7.
Table 7. Receiver Discard Policies
Policy # RXMODE[1:0]
Policy Description
0
00
Keep all received characters
1
01
Process Commands, discard all
but the last C5.0 character
2
10
Process Commands, discard all
C5.0 characters
3
11
Process Commands, discard all
C5.0 characters, discard serial
addresses
Policy 0 is the simplest and also applies for all conditions
where the Receive FIFO is bypassed. In this mode, every
character that is received is placed into the Receive FIFO
(when enabled) or into the Receive Output Register.
In discard policy 1, all Start Of Cell, extended command, and
serial address commands are processed as they are received.
The C5.0 character, which is automatically transmitted when
no data is present in the Transmit FIFO, is treated differently
here. In this mode, whenever two or more adjacent C5.0
characters are received, all of them are discarded except the
last one received before any other character type. This allows
these fill characters to be removed from the data stream, but
does not change the data flow for protocols (like Fibre
Channel) that use a single C5.0 character as a delimiter.
Policy 2 is identical to policy 1 except that all C5.0 characters
are removed from the data stream.
Policy 3 is a super-set of policy 2, where the serial address is
also discarded.
When the FIFOs are bypassed (FIFOBYP* LOW), no
characters are actually discarded, but the receiver discard
policy can be used to control external filtering of the data. The
RXEMPTY* FIFO flag is used to indicate if the character on
the output bus is valid or not. In discard policy 0, the
RXEMPTY* flag is always deasserted to indicate that valid
data is always present. In discard policy 1 when a series of
C5.0 characters are received, the RXEMPTY* flag indicates
an empty condition for all but the last C5.0 character before
any other character is presented. In discard policies 2 or 3, the
RXEMPTY* flag indicates an empty condition for all C5.0
characters. When any other character is present, this flag
indicates that valid or “interesting” Data or Special Characters
are present.
Receive FIFO
The Receive FIFO is used to buffer data captured from the
selected serial stream for later processing by the host system.
Document #: 38-02008 Rev. *E
Page 23 of 58
CY7C924ADX
This FIFO is sized to hold 256, 14-bit characters. When the
FIFO is enabled, it is written to by the Receive Control State
Machine. When data is present in the Receive FIFO (as
indicated by the RXFULL*, RXHALF*, and RXEMPTY*
Receive FIFO status flags), it can be read from the Output
Register by asserting AM* and RXEN*.).
The read port on the Receive FIFO may be configured for the
same two timing models as the transmit interface: UTOPIA
and Cascade. Both are forms of a FIFO interface. The UTOPIA
timing model (EXTFIFO = L) has active LOW RXEMPTY* and
RXFULL* status flags, and an active LOW RXEN* enable.
When configured for Cascade operation (EXTFIFO = H), these
same signals are all active HIGH. The RXHALF* signal is
always active LOW, regardless of EXTFIFO setting. Either
timing model supports connection to various host bus interfaces, state machines, or external FIFOs for depth expansion
(see Figure 5
The Receive FIFO presents Full, Half-Full, and Empty FIFO
status flags. These flags are provided synchronous to RXCLK
to allow operation with a Moore-type external controlling state
machine. When configured with the Receive FIFO enabled,
RXCLK is an input. When the Receive FIFO is bypassed
(FIFOBYP* is LOW), RXCLK is an output operating at the
received character rate.
Receive Input Register
The input register is clocked by the rising edge of RXCLK. It
samples numerous signals that control the reading of the
Receive FIFO and operation of the Receive Control State
Machine.
Figure 5. External FIFO Depth Expansion of the
CY7C924ADX Receive Data Path
CY7C924ADX
CY7C42x5 FIFO
EF*
REN*
Q
RXCLK
EF*
REN*
Q
RCLK
The Receive Output Register changes in response to the
rising edge of RXCLK. When the Receive FIFO is enabled
(FIFOBYP* = H), the FIFO status flag outputs of this register
are placed in a High-Z state when the CY7C924ADX is not
addressed (AM* is sampled HIGH). The RXDATA bus output
drivers are enabled when the device is selected by RXEN*
being asserted in the RXCLK cycle immediately following that
in which the device was addressed (AM* is sampled LOW),
and RXEN* being sampled by RXCLK. This initiates a Receive
FIFO read cycle.
Just as with the TXDATA bus on the Transmit Input Register,
the receive outputs are also mapped by the specific decoding
and bus-width selected by the ENCBYP*, BYTE8/10* and
FIFOBYP* inputs. These assignments are shown in Table 8 on
page 25.
When the Decoder and Receive FIFO are both enabled, the
Receive Control State Machine interprets and discards
(except in discard policy 0) received C0.0 and C3.0 command
codes as set and clear directives for the RXINT output. This
allows the RXINT output to duplicate the state transitions
presented to the TXINT input at the source end of the link. This
RXINT output can be used, along with TXHALT*, TXINT, and
RXHALF*, to implement a back-pressure mechanism for the
Receive FIFO, or for other time dependent signalling.
If the Receive FIFO and Decoder are bypassed, all received
characters are passed directly to the Receive Output Register.
If framing is enabled, and K28.5 characters have been
detected meeting the present framing requirements, the
output characters will appear on proper character boundaries.
If framing is disabled (RFEN is LOW) or K28.5 characters have
not been detected in the data stream, the received characters
may not be output on their proper 10-bit boundaries. In this
mode, some form of external framing and decoding/descrambling must be used to recover the original source data.
RXEN
FF*
RXEMPTY
WEN*
RXDATA
RXSC/D*
D
RXCLK
WCLK
“1”
Document #: 38-02008 Rev. *E
Receive Output Register
EXTFIFO
Serial Address Register
When the device is in UTOPIA mode (EXTFIFO = LOW), the
receiver is capable of selectively accepting or discarding
received data based on an address received in the data
stream. The address matching capability allows for the choice
of matching of either domains (multicast) or exact addresses
(unicast). The 8- or 10-bit Serial Address Register represents
a single character address field as shown in Figure 6 on page
25.
The multicast mode is bit-specific and allows allocation of up
to 8 or 10 separate domains. In the unicast address mode the
match is character specific and identifies up to 256 or 1024
destination addresses. A device can either belong to one or
more domains, or it can have a single unique address.
Page 24 of 58
CY7C924ADX
Table 8. Receive Output Bus Signal Map
Receive Decoder Mode[3]
Decoded 10-bit
Character Stream
(8-bit characters)
Undecoded 10-bit
Character Stream
Decoded 10-bit
Byte-Packed
Character Stream
(10-bit characters)
Undecoded 12-bit
Character Stream
ENCBYP*
HIGH
LOW
HIGH
LOW
BYTE8/10*
HIGH
HIGH
LOW
LOW
RXDATA Bus I/O Bit
RXSC/D*
RXSC/D*
RXSC/D*
RXDATA[0]
RXD[0]
RXD[0][3]
RXDATA[1]
RXD[1]
RXD[1]
RXD[1]
RXD[1]
RXDATA[2]
RXD[2]
RXD[2]
RXD[2]
RXD[2]
RXDATA[3]
RXD[3]
RXD[3]
RXD[3]
RXD[3]
RXDATA[4]
RXD[4]
RXD[4]
RXD[4]
RXD[4]
RXDATA[5]
RXD[5]
RXD[5]
RXD[5]
RXD[5]
RXDATA[6]
RXD[6]
RXD[6]
RXD[6]
RXD[6]
RXDATA[7]
RXD[7]
RXD[7]
RXD[7]
RXD[7]
RXINT/RXDATA[8]
(FIFOBYP*=HIGH)
RXINT
RXD[8]
RXD[8]
RXD[8]
RXD[8]
RXD[8]
RXD[8]
RXINT/RXDATA[8]
(FIFOBYP*=LOW)
RXD[9]
RXD[0]
RXD[0][3]
RXDATA[9]
(LOW)
RXD[9]
RXD[9]
RXRVS/RXDATA[10]
RXRVS
RXRVS
RXD[10]
RXSOC/RXDATA[11]
RXSOC
RXSOC
RXD[11]
When accessed for write or read operations, the RXRVS
signal is used as a read/write selector, and RXSC/D* is used
to select the operating mode (multicast or unicast) of the Serial
Address Register.
Figure 6. Serial Address Register Format and Access
The Serial Address Register is accessed through the RXDATA
bus. Both reads and writes to the register require the device to
be addressed (AM* is LOW) and for RXRST* to be asserted
(LOW).
MSB
0
0
0
0
0
0
0
LSB
RXSC/D*
0
0
RXDATA[0]
Serial Address Register
RXRVS
Serial Address Register Access
RXDATA[9] or [7]
RXRST*
The Serial Address Register is only used when the receiver is
operated with the Receive FIFO enabled (FIFOBYP* is HIGH)
and in operating modes where the discard policy is not 0 (see
Table 7 on page 23 for a list of discard policies).
Address Register Content
RXEN*
When a serial address is received and a match is detected, the
address, and all data following that address, is passed to the
Receive FIFO (except in discard policy 3 where the address is
discarded). This continues until a serial address is received
that does not match the contents of the Address Register,
whereupon writes to the Receive FIFO are inhibited.The Serial
Address Register has a power-up default state where the
multicast field set to an all ones condition (FFh or 3FFh). When
set to this value the receiver accepts all data, regardless of the
presence or content of any received serial address. This
“promiscuous” address can also be forced by the momentary
assertion of the RESET*[1:0] pair.
Multicast Address write
0
1
0
1
0
Multicast Address read
1
1
Unicast Address read
Unicast Address write
Note
3. First bit shifted in. Others follow in numerical order interpreted from an NRZ pattern.
Document #: 38-02008 Rev. *E
Page 25 of 58
CY7C924ADX
Maximum Ratings
Output Current into TTL Outputs (LOW) ..................... 30 mA
DC Input Voltage ................................... –0.5V to VDD + 0.5V
(Above which the useful life may be impaired. For user guidelines, not tested.)
Static Discharge Voltage.......................................... > 2001 V
(per MIL-STD-883, Method 3015)
Storage Temperature ................................. –65°C to +150°C
Latch-up Current..................................................... > 200 mA
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Operating Range
Supply Voltage to Ground Potential ............... –0.5V to +6.5V
Range
DC Voltage Applied to Outputs
in High-Z State .......................................–0.5V to VDD + 0.5V
Commercial
Industrial
Ambient Temperature
VDD
0°C to +70°C
5.0V ± 10%
–40°C to +85°C
5.0V ± 10%
CY7C924ADX DC Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
Min
Max
Unit
TTL Outputs
VOHT
Output HIGH Voltage
IOH = –2 mA, VDD = Min.
VOLT
Output LOW Voltage
IOL = 8 mA, VDD = Min.
IOST
Output Short Circuit Current
IOZL
High-Z Output Leakage Current
VOUT =
0V[4]
2.4
V
0.4
V
–30
–80
mA
–20
20
μA
2.0
VDD
V
TTL Inputs
VIHT
Input HIGH Voltage
VILT
Input LOW Voltage
IIHT
Input HIGH Current
IILT
Input LOW Current
VIN = 0.0V
–40
μA
IIHPD
Input HIGH Current
VIN = VDD, Pins with internal pull-down
+300
μA
IILPU
Input LOW Current
VIN = 0.0V, Pins with internal pull-up
–0.5
VIN = VDD
0.8
V
+40
μA
μA
–300
Transmitter PECL-Compatible Output Pins: OUTA+, OUTA–, OUTB+, OUTB–[5]
VOHE
Output HIGH Voltage (VDD referenced)
Load = 50Ω to VDD – 1.33V RCURSET= 10k VDD – 1.03 VDD – 0.83
V
VOLE
Output LOW Voltage (VDD referenced)
Load = 50Ω to VDD – 1.33V RCURSET= 10k
VDD – 2
VDD – 1.62
V
VODIF
Output Differential Voltage
|(OUT+) – (OUT–)|
Load = 50Ω to VDD – 1.33V RCURSET= 10k
600
1100
mV
VDD – 1.165
VDD
V
2.5
VDD – 1.475
V
+40
μA
Receiver Single-ended PECL-compatible Input Pin: CARDET
VIHE
Input HIGH Voltage (VDD referenced)
VILE
Input LOW Voltage (VDD referenced)
IIHE
Input HIGH Current
VIN = VIHE(min.)
IILE
Input LOW Current
VIN = VILE(max.)
μA
–40
Differential Line Receiver Input Pins: INA+, INA–, INB+, INB–
VDIFF
Input Differential Voltage |(IN+) – (IN–)|
VIHH
Highest Input HIGH Voltage
200
VILL
Lowest Input LOW Voltage
IIHH
Input HIGH Current
VIN = VIHH Max.
IILL[6]
Input LOW Current
VIN = VILL Min.
Power Supply Current
mV
VDD
V
750
μA
2.5
Miscellaneous
IDD [7]
2500
Freq. = Max.
V
μA
–200
Typ.
Max.
170
250
mA
Notes
4. Tested one output at a time, output shorted for less than one second, less than 10% duty cycle.
5. The output current and (resulting voltage swing) is set using a single resistor between CURSETx and VSS. This CURSET resistor value is calculated as
RCURSET = (90*ZLOAD)/VODIF, where ZLOAD is the differential load between the true and compliment outputs of the differential driver.
6. To guarantee positive currents for all PECL voltages, an external pull-down resistor must be present.
7. Maximum IDD is measured with VDD = MAX, RFEN = LOW, and outputs unloaded. Typical IDD is measured with VDD = 5.0V, TA = 25°C, RFEN = LOW, and
outputs unloaded.
Document #: 38-02008 Rev. *E
Page 26 of 58
CY7C924ADX
Capacitance[8]
Parameter
Description
Test Conditions
Max
Unit
CINTTL
TTL Input Capacitance
TA = 25°C, f0 = 1 MHz, VDD = 5.0V
7
pF
CINPECL
PECL-compatible input Capacitance
TA = 25°C, f0 = 1 MHz, VDD = 5.0V
4
pF
AC Test Loads and Waveforms
5.0V
R1
OUTPUT
R1 = 500Ω
R2 = 333Ω
CL ≤ 10 pF
(Includes fixture and
probe capacitance)
CL
CL
R2
(a) TTL AC Test Load
3.0V
3.0V
Vth=1.5V
0.0V
RL
2.0V
Note 9
2.0V
0.8V
[9]
(b) PECL AC Test Load
80%
VILE
≤ 1 ns
≤ 1 ns
[9]
VIHE
VIHE
Vth=1.5V
0.8V
VDD – 1.33V
RL = 50 Ω
CL < 5 pF
(Includes fixture and
probe capacitance)
80%
20%
20%
VILE
≤ 1 ns
(c) TTL Input Test Waveform
≤ 1 ns
(d) PECL Input Test Waveform
CY7C924ADX Transmitter TTL Switching Characteristics, FIFO Enabled Over the Operating Range
Parameter
Description
Min
Max
Unit
50
MHz
fTS
TXCLK Clock Cycle Frequency With Transmit FIFO Enabled
tTXCLK
TXCLK Period
20
ns
tTXCPWH
TXCLK HIGH Time
6.5
ns
tTXCPWL
TXCLK LOW Time
6.5
ns
tTXCLKR[8]
tTXCLKF[8]
TXCLK Rise
Time[10]
TXCLK Fall Time[10]
0.7
5
ns
0.7
5
ns
15
tTXA
Flag Access Time From TXCLK↑ to Output
2
tTXDS
Transmit Data Setup Time to TXCLK↑
4
ns
tTXDH
Transmit Data Hold Time from TXCLK↑
1
ns
tTXENS
Transmit Enable Set-Up Time to TXCLK↑
4
ns
tTXENH
Transmit Enable Hold Time from TXCLK↑
1
ns
tTXRSS
Transmit FIFO Reset (TXRST*) Setup Time to TXCLK↑
4
ns
tTXRSH
Transmit FIFO Reset (TXRST*) Hold Time from TXCLK↑
1
ns
tTXAMS
Transmit Address Match (AM*) Setup Time to TXCLK↑
4
ns
tTXAMH
Transmit Address Match (AM*) Hold Time from TXCLK↑
1
ns
tTXZA
Sample of AM* LOW by TXCLK↑, Output High-Z to Active HIGH or LOW
0
ns
tTXOE
Sample of AM* LOW by TXCLK↑ to Output Valid
1.5
20
ns
tTXAZ
Sample of AM* HIGH by TXCLK↑ to Output in High-Z
1.5
20
ns
ns
Notes
8. Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.
9. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.
10. Input/output rise and fall time is measured between 0.8V and 2.0V.
Document #: 38-02008 Rev. *E
Page 27 of 58
CY7C924ADX
CY7C924ADX Receiver TTL Switching Characteristics, FIFO Enabled Over the Operating Range
Parameter
Description
Min
Max
Unit
50
MHz
fRIS
RXCLK Clock Cycle Frequency With Receive FIFO Enabled
tRXCLKIP
RXCLK Input Period
tRXCPWH
RXCLK Input HIGH Time
6.5
ns
tRXCPWL
RXCLK Input LOW Time
6.5
ns
tRXCLKIR[8]
RXCLK Input Rise Time[10]
0.7
5
ns
tRXCLKIF[8]
RXCLK Input Fall Time[10]
0.7
5
ns
20
ns
tRXENS
Receive Enable Setup Time to RXCLK↑
4
ns
tRXENH
Receive Enable Hold Time from RXCLK↑
1
ns
tRXRSS
Receive FIFO Reset (RXRXT*) Setup Time to RXCLK↑
4
ns
tRXRSH
Receive FIFO Reset (RXRXT*) Hold Time from RXCLK↑
1
ns
tRXAMS
Receive Address Match (AM*) Setup Time to RXCLK↑
4
ns
tRXAMH
Receive Address Match (AM*) Hold Time from RXCLK↑
1
ns
tRXA[11]
tRXZA[11]
Flag and Data Access Time from RXCLK↑ to Output
Sample of AM* LOW by RXCLK↑, Output High-Z to Active HIGH or LOW,
or Sample of RXEN* Asserted by RXCLK↑, Output High-Z to Active HIGH or LOW
1.5
15
0
ns
ns
tRXOE[11]
Sample of AM* LOW by RXCLK↑ to Output Valid,[11]
or Sample of RXEN* Asserted by RXCLK↑ to RXDATA Outputs Valid
1.5
20
ns
tRXAZ[11]
Sample of AM* HIGH by RXCLK↑ to Output in High-Z,[11]
or Sample of RXEN* Deasserted by RXCLK↑ to RXDATA Outputs in High-Z
1.5
20
ns
CY7C924ADX Transmitter TTL Switching Characteristics, FIFO Bypassed Over the Operating Range
Min
Max
Unit
tTRA
Parameter
Flag Access Time From REFCLK↑ to Output
Description
2
15
ns
tREFDS
Write Data Set-Up Time to REFCLK↑
4
ns
tREFDH
Write Data Hold Time from REFCLK↑
2
ns
tREFENS
Transmit Enable Setup Time to REFCLK↑
4
ns
tREFENH
Transmit Enable Hold Time from REFCLK↑
2
ns
tREFAMS
Transmit Address Match (AM*) Setup Time to REFCLK↑
4
ns
tREFAMH
Transmit Address Match (AM*) Hold Time from REFCLK↑
2
ns
tREFZA
Sample of AM* LOW by REFCLK↑, Output High-Z to Active HIGH or LOW
tREFOE
Sample of AM* LOW by REFCLK↑ to Flag Output Valid
1.5
20
ns
tREFAZ
Sample of AM* HIGH by REFCLK↑ to Flag Output High-Z
1.5
20
ns
0
ns
Note
11. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.
Document #: 38-02008 Rev. *E
Page 28 of 58
CY7C924ADX
CY7C924ADX Receiver TTL Switching Characteristics, FIFO Bypassed Over the Operating Range
Parameter
fROS[12]
Description
Min
Max
Unit
RXCLK Clock Output Frequency—100 to 200 MBaud
(RANGESEL is HIGH, ENCBYP* is HIGH or BYTE8/10* is HIGH)
10
20
MHz
RXCLK Clock Output Frequency—50 to 100 MBaud
(RANGESEL is LOW, ENCBYP* is HIGH or BYTE8/10* is HIGH)
5
10
MHz
RXCLK Clock Output Frequency—100 to 200 MBaud
12-bit Encoder Bypass Operation
(RANGESEL is HIGH, ENCBYP* is LOW and BYTE8/10* is LOW)
8.33
16.67
MHz
RXCLK Clock Output Frequency—50 to 100 MBaud 10-bit Operation
(RANGESEL is LOW, ENCBYP* is LOW and BYTE8/10* is LOW)
4.16
8.33
MHz
25
250
ns
tRXCLKOP
RXCLK Output Period
tRXCLKOD
RXCLK Output Duty Cycle
40
60
%
tRXCLKOR[8]
RXCLK Output Rise Time[10]
0.25
2
ns
tRXCLKOF[8]
RXCLK Output Fall Time[10]
0.25
2
ns
tRXENS
Receive Enable Setup Time to RXCLK↑
tRXENH
Receive Enable Hold Time from RXCLK↑
1
ns
tRXZA[11]
Sample of AM* LOW by RXCLK↑, Outputs High-Z to Active
Sample of RXEN* Asserted by RXCLK↑ to RXDATA Outputs High-Z to Active
0
ns
tRXOE[11]
Sample of AM* LOW by RXCLK↑ to Flag Output Valid
Sample of RXEN* Asserted by RXCLK↑ to RXDATA Output Low-Z
1.5
20
ns
tRXAZ[11]
Sample of AM* HIGH by RXCLK↑ to Flag Output High-Z
Sample of RXEN* Deasserted by RXCLK↑ to RXDATA Output High-Z
1.5
20
ns
Min
Max
Unit
5.0
20.0
ns
0.5
UI
600
ps
4
ns
CY7C924ADX Receiver Switching Characteristics Over the Operating Range
Parameter
Description
tB[15]
Bit Time
tIN_J
IN± Peak-to-Peak Input Jitter Tolerance[13, 14]
Alignment[8, 16]
tSA
Static
tEFW
Error Free Window [8, 13, 17]
0.65
UI
CY7C924ADX Transmitter Switching Characteristics Over the Operating Range
Parameter
Description
Min
Max
Unit
5.0
20.0
ns
200
1700
ps
tB[15]
Bit Time
tRISE
PECL-compatible Output Rise Time 20−80% (PECL Test Load)[8]
200
Load)[8]
tFALL
PECL-compatible Output Fall Time 80−20% (PECL Test
1700
ps
tDJ
Deterministic Jitter (peak-peak)[8, 18]
0.02
UI
tRJ
Random Jitter
(σ) [8, 19]
0.008
UI
tJT
Transmitter Total Output Jitter (pk-pk)[8]
0.08
UI
Notes
12. The period of fROS will match the period of the transmitter PLL reference (REFCLK) when receiving serial data. When data is interrupted, RXCLK may drift to
REFCLK ±2500 ppm.
13. Receiver UI (Unit Interval) is calculated as 1/(Serial Baud Rate), where Baud Rate is the rate of change of signaling.
14. The specification is sum of 25% Duty Cycle Distortion (DCD), 10% Data Dependant Jitter (DDJ), 15% Random Jitter (RJ).
15. The PECL switching threshold is the midpoint between the VOHE, and VOLE specifications (approximately VDD − 1.33V).
16. Static alignment is a measure of the alignment of the Receiver sampling point to the center of a bit. Static alignment is measured by the absolute difference of
the left and right edge shifts (|tSH_L - tSH_R|) of one bit until a character error occurs.
17. Error Free Window is a measure of the time window between bit centers where a transition may occur without causing a bit sampling error. EFW is measured
over the operating range, input jitter < 50% Dj.
18. While sending continuous K28.5s, outputs loaded to 50Ω to VDD− 1.33V, over the operating range.
19. While sending continuous K28.7s, after 100,000 samples measured at the cross point of differential outputs, time referenced to REFCLK input, over the
operating range.
Document #: 38-02008 Rev. *E
Page 29 of 58
CY7C924ADX
CY7C924ADX REFCLK Input Switching Characteristics Over the Operating Range
Parameter
fREF
fREF
Conditions
Description
SPDSEL RANGESEL BYTE8/10*
Min
Max
Unit
16.67 MHz
REFCLK Clock Frequency—50 to 100 MBaud, 10-bit
mode, encoder bypass, REFCLK = 2x character rate
0
0
0
8.33
REFCLK Clock Frequency—50 to 100 MBaud,
8-bit mode, REFCLK = 2x character rate
0
0
1
10
REFCLK Clock Frequency—50 to 100 MBaud, 10-bit
mode, encoder bypass, REFCLK = 4x character rate
0
1[20]
0
REFCLK Clock Frequency—50 to 100 MBaud,
8-bit mode, REFCLK = 4x character rate
0
1[20]
1
20
REFCLK Clock Frequency—100 to 200 MBaud, 10-bit
mode, encoder bypass, REFCLK = character rate
1
0
0
8.33
REFCLK Clock Frequency—100 to 200 MBaud, 8-bit
mode, REFCLK = character rate
1
0
1
10
20
MHz
REFCLK Clock Frequency—100 to 200 MBaud, 10-bit
mode, encoder bypass, REFCLK = 2x character rate
1
1
0
16.67
33.3
MHz
REFCLK Clock Frequency—100 to 200 MBaud, 8-bit
mode, REFCLK = 2x character rate
1
1
1
20
40
MHz
120
ns
20
MHz
16.67 33.33 MHz
40
MHz
16.67 MHz
tREFCLK
REFCLK Period
25
tREFH
REFCLK HIGH Time
6.5
ns
tREFL
REFCLK LOW Time
6.5
ns
tREFRX
REFCLK Frequency Referenced to Received Clock
Period[21]
–0.04 +0.04
%
CY7C924ADX HOTLink Transmitter Switching Waveforms
Asynchronous (FIFO) Interface
Cascade Timing
Write Cycle
tTXCLK
tTXCPWH
tTXCPWL
TXCLK
tTXDS
TXDATA[11:0],
TXSC/D*
tTXDH
Note 22
tTXENH
TXEN
tTXENS
tTXA
TXFULL
TXHALF*
TXEMPTY
tTXA
Notes
20. When configured for synchronous operation with the FIFOs bypassed (FIFOBYP* is LOW), if RANGESEL is HIGH the SPDSEL input is ignored and operation
is forced to the 100–200 MBaud range.
21. REFCLK has no phase or frequency relationship with RXCLK and only acts as a centering reference to reduce clock synchronization time. REFCLK must be
within ±0.04% of the transmitter PLL reference (REFCLK) frequency.
22. When transferring data to the Transmit FIFO from a depth expanded external FIFO (EXTFIFO = H), the data is captured from the external FIFO one clock cycle
following the actual enable.
Document #: 38-02008 Rev. *E
Page 30 of 58
CY7C924ADX
CY7C924ADX HOTLink Transmitter Switching Waveforms (continued)
Asynchronous (FIFO) Interface
UTOPIA Timing
Write Cycle
tTXCLK
tTXCPWH
tTXCPWL
TXCLK
tTXDS
TXDATA[11:0],
TXSC/D*
tTXDH
Note 23
tTXENS
tTXENH
TXEN*
NO OPERATION
tTXA
TXFULL*
TXHALF*
TXEMPTY*
tTXA
Asynchronous (FIFO) Interface
Output Enable Timing
tTXCLK
tTXCPWH
tTXCPWL
TXCLK
tTXENS
TXEN*
tTXENH
Note 24
NO OPERATION
tTXAMS
tTXRSS
tTXAMH, tTXRSH,
AM*
TXRST*
tTXOE
tTXAZ
TXFULL*
TXHALF*
TXEMPTY*
tTXZA
Notes
23. When writing data from a UTOPIA compliant interface (EXTFIFO = L), the write data is captured on the same clock cycle as the data.
24. Signals shown as dotted lines represent the differences in timing and active state of signals when operated in Cascade Timing.
Document #: 38-02008 Rev. *E
Page 31 of 58
CY7C924ADX
CY7C924ADX HOTLink Transmitter Switching Waveforms (continued)
Synchronous Interface
Cascade Timing
Write Cycle
tREFCLK
tREFL
tREFH
REFCLK
tREFDS
TXDATA[11:0],
TXSC/D*
tREFDH
Note 22
tREFENH
tTRXA
NO OPERATION
TXEN
tREFENS
tTRXA
TXFULL
TXHALF*
TXEMPTY
Synchronous Interface
UTOPIA Timing
Write Cycle
tTRXA
tREFCLK
tREFH
tREFL
REFCLK
tREFDS
TXDATA[11:0],
TXSC/D*
tREFDH
Note 23
tREFENS
tREFENH
TXEN*
NO OPERATION
tTRXA
TXFULL*
TXHALF*
TXEMPTY*
Document #: 38-02008 Rev. *E
tTRXA
Page 32 of 58
CY7C924ADX
CY7C924ADX HOTLink Transmitter Switching Waveforms (continued)
Synchronous Interface
Output Enable Timing
tREFCLK
tREFH
tREFL
REFCLK
tREFENS
tREFENH
Note 24
TXEN*
NO OPERATION
tREFAMS
tREFAMH
AM*
tREFOE
tREFAZ
TXFULL*
TXHALF*
TXEMPTY*
tREFZA
CY7C924ADX HOTLink Receiver Switching Waveforms
tRXCLKOP
tRXCLKIP
Cascade Timing
Read Cycle
tRXCLKOH
tRXCLKIH
tRXCLKOL
tRXCLKIL
RXCLK
tRXENH
tRXENS
RXEN
NO OPERATION
READ
tRXA
FIFO EMPTY
RXEMPTY
RXDATA[11:0]
RXSC/D*
RXINT, LFI*
RXFULL
RXHALF*
tRXA
Note 25
VALID DATA
AM*
Note
25. On inhibited reads when RXEN* is deasserted or BISTEN* is asserted, or if the Receive FIFO goes empty, the data outputs do not change.
Document #: 38-02008 Rev. *E
Page 33 of 58
CY7C924ADX
CY7C924ADX HOTLink Receiver Switching Waveforms (continued)
tRXCLKOP
tRXCLKIP
UTOPIA Timing
Read Cycle
tRXCLKOH
tRXCLKIH
tRXCLKOL
tRXCLKIL
RXCLK
tRXENS
tRXENS
RXEN*
tRXENH, tRXENH
READ
tRXA
tRXA
FIFO EMPTY
RXEMPTY*
RXDATA[11:0]
RXSC/D*
RXINT, LFI*
RXFULL*
RXHALF*
Note 25
VALID DATA
AM*
tRXCLK
Output Enable Timing
tRXCPWH
tRXCPWL
RXCLK
tRXOENS
tRXIENS
RXEN*
tRXIENH, tRXOENH
Note 25
AM*
RXFULL*
RXHALF*
RXEMPTY*
RXDATA[11:0]
RXINT
RXSC/D*
Document #: 38-02008 Rev. *E
NO OPERATION
tRXOAMS
tRXIAMS
tRXIAMH, tRXOAMH
tRXOE
tRXAZ
Note 25
tRXOOZA
tRXIOZA
Page 34 of 58
CY7C924ADX
CY7C924ADX HOTLink Receiver Switching Waveforms (continued)
tREFCLK
tREFL
tREFH
REFCLK
Static Alignment
Error-Free Window
tB/2 – tSA
tB/2 – tSA
tEFW
INA±
INB±
INA±
INB±
tB
SAMPLE WINDOW
CY7C924ADX HOTLink Transceiver Operation
The interconnection of two or more CY7C924ADX Transceivers form a general-purpose communications subsystem
capable of transporting user data at up to 20 MBytes per
second over several types of serial interface media. The
CY7C924ADX is highly configurable with multiple modes of
operation.
In the transmit section of the CY7C924ADX, data moves from
the input register, through the Transmit FIFO, to the 8B/10B
Encoder. The encoded data is then shifted serially out the
OUTx± differential PECL-compatible drivers. The bit-rate
clock is generated internally from a 2.5x, 5x, or 10x PLL clock
multiplier (3x, 6x, or 12x if BYTE8/10* and ENCBYP* are
LOW). A more complete description is found in the section
CY7C924ADX HOTLink Transmit-Path Operating Mode
Description.
In the receive section of the CY7C924ADX, serial data is
sampled by the receiver on one of the INx± differential line
receiver inputs. The receiver clock and data recovery PLL
locks onto the selected serial bit stream and generates an
internal bit-rate sample clock. The bit stream is deserialized,
decoded, and presented to the Receive FIFO, along with a
character clock. The data in the FIFO can then be read either
slower or faster than the incoming character rate. A more
complete description is found in the section CY7C924ADX
HOTLink Receive-Path Operating Mode Description.
The Transmitter and Receiver parallel interface timing and
functionality can be configured to Cascade directly to external
FIFOs for depth expansion, to emulate a UTOPIA interface,
couple directly to registers, or couple directly to state
machines. These interfaces can accept or output either:
• 8-bit characters
• 10-bit characters (for byte-packed encoded transport)
• 10-bit pre-encoded characters (pre-scrambled or
pre-encoded)
• 12-bit pre-encoded characters (pre-scrambled or
pre-encoded)
Document #: 38-02008 Rev. *E
BIT CENTER
BIT CENTER
The bit numbering and content of the parallel transmit interface
is shown in Table 1 on page 13. When operated with the
8B/10B Encoder bypassed, the TXSC/D* and RXSC/D* bits
are ignored.
The HOTLink Transceiver serial interface provides a seamless
interface to various types of media. A minimal number of
external passive components are required to properly
terminate transmission lines and provide LVPECL loads. For
power supply decoupling, a single capacitor (in the range of
0.02 μF to 0.1 μF) is required per power/ground pair. Additional
information on interfacing these components to various media
can be found in the HOTLink Design Considerations application note.
CY7C924ADX HOTLink Transmit-Path
Operating Mode Description
The HOTLink Transmitter can be configured into several
operating modes, each providing different capabilities and
fitting different transmission needs. These modes are selected
using the FIFOBYP*, ENCBYP* and BYTE8/10* inputs on the
CY7C924ADX Transceiver. These modes can be reduced to
five primary classes:
• Synchronous Encoded
• Synchronous Pre-encoded
• Asynchronous Encoded
• Asynchronous Byte-packed
• Asynchronous Pre-encoded
Synchronous Encoded
In this mode, the Transmit FIFO is bypassed, while the 8B/10B
encoder is enabled. One character is accepted at the Transmit
Input Register at the rising edge of REFCLK, and passed to
the Encoder where it is encoded for serial transmission. The
Serializer operates synchronous to REFCLK, which is multiplied by 10 or 5 to generate the serial data bit-clock. In this
mode the TXSOC, TXRST*, TXINT, TXHALT*, and TXSTOP*
inputs (when they are not used for data bits) are not interpreted
Page 35 of 58
CY7C924ADX
and may be tied either HIGH or LOW. To place the
CY7C924ADX into synchronous modes, FIFOBYP* must be
LOW.
This mode is usually used for products that must meet specific
predefined protocol requirements, and cannot tolerate the
uncontrolled insertion of C5.0 fill characters. The host system
is required to asset TXEN* and to provide new data at every
appropriate rising edge of REFCLK to maintain the data
stream. If TXEN* is not asserted, the Encoder is loaded with
C5.0 (K28.5) sync characters. Because the Encoder is
enabled, the transmitted C5.0 characters follow all 8B/10B
encoding rules.
Input Register Mapping
In Encoded modes, the bits of the TXDATA input bus are
mapped into characters (as shown in Table 1 on page 13),
including a TXSVS bit, eight or ten bits of data, and a TXSC/D*
bit to select either Special Character codes or Data characters.
If the TXSVS bit is HIGH, an SVS (C0.7) character is passed
to the encoder, regardless of the contents of the other TXDATA
inputs. If the TXSVS bit is LOW, the associated TXDATA
character is encoded per the remaining bits in that character.
The TXSC/D* bit controls the encoding of the TXDATA[7:0] or
TXDATA[9:0] bits of each character. It is used to identify if the
input character represents a Data Character or a Special
Character code. If TXSC/D* is LOW, the character is encoded
using the Data Character codes listed in Table 11 on page 51.
If TXSC/D* is HIGH, the character is encoded using the
Special Character codes listed in Table 12 on page 55.
Synchronous Pre-encoded
In synchronous pre-encoded mode (FIFOBYP* and ENCBYP*
are LOW), both the Transmit FIFO and the 8B/10B encoder
are bypassed, and data passes directly from the Transmit
Input Register to the Serializer. The Serializer operates
synchronous to REFCLK to generate the serial data bit-clock.
As selected by SPDSEL and RANGESEL, the REFCLK input
is multiplied by 5 or 10 when BYTE8/10* is HIGH or by 6 or 12
when BYTE8/10* is LOW. In this mode the TXINT, TXHALT*,
TXSVS and TXSOC inputs are used as part of the data input
bus.
This mode is usually used for products containing external
encoders or scramblers, that must meet specific protocol
requirements. The host system is required to assert TXEN*
and to provide new data at every appropriate rising edge of the
REFCLK to maintain the data stream. If TXEN* is not asserted,
the Serializer is loaded with C5.0 (K28.5) sync characters.
However, because the bypassed encoder is not able to track
the running disparity of the previously transmitted character,
the transmitted C5.0 characters may be received with a
running disparity code-rule violation.
In this mode the LSB of each input character (TXDATA[0]) is
shifted out first, followed sequentially by TXDATA[1] through
TXDATA[9].
Asynchronous Encoded
Asynchronous Encoded mode is the most powerful operating
mode of the CY7C924ADX. Both the Transmit FIFO and the
Encoder are enabled (FIFOBYP* and ENCBYP* are HIGH).
This allows transmission of normal data streams, while
Document #: 38-02008 Rev. *E
offering the added benefits of embedded cell or packet
markers, an expanded command set, serial addressing, and
in-band bypass-signaling (for flow control or other purposes).
All characters added to the data stream to support these
additional capabilities may be automatically extracted by the
Receive Control State Machine in the CY7C924ADX Receiver.
The Serializer operates synchronous to REFCLK, which is
multiplied by 2.5, 5, or 10 to generate the serial data bit-clock
(as selected by SPDSEL and RANGESEL). In this mode the
TXSOC, TXSC_D*, TXRST*, TXSVS, TXINT/TXDATA[8],
TXHALT*/TXDATA[9], and TXSTOP* inputs are interpreted.
Embedded Cell Marker
An embedded cell marker is used to mark the start of cells or
frames of information passed from one end of the link to the
other. This marker is set by asserting TXSOC HIGH, with
TXSC/D* and TXSVS both LOW, along with the remaining
data on the TXDATA bus. When the data character accompanying this marker is read from the output end of the Transmit
FIFO, a C8.0 (K23.7) character is inserted into the data stream
prior to the associated data character being read from the
Transmit FIFO.
Expanded Commands
The standard 8B/10B Character set contains all 256 possible
data characters, but only twelve special or command
characters. To allow use of a larger selection of command
codes, a Special Character code was selected to expand the
command set.
An expanded command marker is used to mark the associated
data as any one of 256 (28) possible commands codes. This
marker is generated by asserting both TXSOC and TXSC/D*
HIGH, with TXSVS being LOW, along with the associated data
on the TXDATA bus. When the character accompanying this
marker is read from the output end of the Transmit FIFO, a
C9.0 (K27.7) character is inserted into the data stream prior to
the data character being read from the Transmit FIFO.
Serial Addressing
The CY7C924ADX receiver has the ability to accept or reject
data based on an internal address-controlled switch. This
switch is turned on when a serial address matching the
receiver address settings is received. When the serial address
received does not match the address programmed into the
receiver, the receiver’s input is ignored.
A serial address is transmitted by asserting TXSOC, TXSC/D*,
and TXSVS all HIGH. When the character accompanying this
marker is read from the output end of the Transmit FIFO, a
C10.0 (K29.7) character is inserted into the data stream prior
to the data characters being read from the Transmit FIFO. The
serial address is either 8 or 10 bits depending on the level on
BYTE8/10*.
In-Band Bypass-Signaling
In-band bypass-signaling allows a signal to be sent to the
remote receiver without that signal having to pass through the
Transmit (or Receive) FIFO. When TXINT transitions, a
character is immediately inserted in the data stream at the
Encoder block, delaying other data encoding for a cycle.
When TXINT transitions from 0→1, a C0.0 (K28.0) special
character is sent. When TXINT transitions from 1→0, a C3.0
Page 36 of 58
CY7C924ADX
(K28.3) special code is sent. These special codes may be
used to force a similar signal transition on the RXINT output of
an attached CY7C924ADX HOTLink Receiver.
CY7C924ADX HOTLink Receive-Path Operating
Mode Descriptions
This input may be used to transport a low data rate signal (like
a serial RS-232/UART signal) across the interface, without any
significant impact on the actual data being transported across
the link. It may also be used to transparently propagate FIFO
flow control information across the link by directly connecting
the RXHALF* flag of the local receiver to the TXINT of the local
transmitter. The RXINT at the remote end of the link can then
be connected to the TXHALT* input to halt data transfers at the
remote end of the link until the local Receive FIFO has sufficient room to continue.
The HOTLink Receiver can be configured into several
operating modes, each providing different capabilities and
fitting different reception needs. These modes are selected
using the FIFOBYP*, ENBYP* and BYTE8/10* inputs on the
CY7C924ADX Transceiver. These modes can be reduced to
five primary classes:
• Synchronous Decoded
• Synchronous Undecoded
• Asynchronous Decoded
• Asynchronous Byte-packed
• Asynchronous Undecoded.
Asynchronous Byte-Packed
Asynchronous byte-packed mode contains the same features
as asynchronous encoded, but with support for 10-bit source
data. This data is byte-packed through the 8B/10B encoder to
deliver the data across the interface. This mode is enabled
when FIFOBYP* and ENCBYP* are HIGH and BYTE8/10* is
LOW.
When sending extended commands, the larger 10-bit
character size enlarges the extended command space to 1024
(210) possible commands codes.
Asynchronous Pre-encoded
In Asynchronous pre-encoded modes, the Transmit FIFO is
enabled and the Encoder is disabled (FIFOBYP* is HIGH and
ENCBYP* is LOW). This means that all words clocked into the
input register are written to the Transmit FIFO before being
sent to the Serializer. The Serializer operates synchronous to
REFCLK to generate the serial data bit-clock. SPDSEL and
RANGESEL determine whether REFCLK is multiplied by 10,
5 or 2.5 (if BYTE8/10* is HIGH) or 3, 6 or 12 (if BYTE8/10* is
LOW). In this mode the TXINT and TXHALT* inputs are used
as part of the 10-bit input character. TXSVS, TXSOC and
TXSTOP* are still available.
These modes are usually used for products containing
external encoders or scramblers, that must meet specific
protocol requirements. The host system must assert TXEN*
and provide new data at every rising edge of TXCLK to
maintain the data stream (without overfilling the Transmit
FIFO). If the Transmit FIFO ever goes empty, the Serializer is
loaded with an alternating disparity string of C5.0 (K28.5) sync
characters (when BYTE8/10* is HIGH) or the bit pattern
0110000100011 (when BYTE8/10* is LOW).
This insertion can be an issue for some system implementations. If the remote receiver is configured to decode 8B/10B
coded characters, it will probably detect running disparity
errors because the bypassed Encoder is not able to track the
running disparity of the previously transmitted character.
However, since these pre-encoded modes are generally used
with alternate forms of scrambling or encoding, for these applications this disparity is not generally an issue.
To maintain a data stream without adding these C5.0 SYNC
codes, it is necessary that the Transmit FIFO be loaded at the
same speed or faster than the rate that data is read from that
FIFO.
Document #: 38-02008 Rev. *E
In all these modes, serial data is received at one of the differential line receiver inputs and routed to the Deserializer and
Framer. The PLL in the clock and data recovery block is used
to extract a bit-rate clock from the transitions in the data
stream, and uses that clock to capture bits from the serial
stream. These bits are passed to the Deserializer where they
are formed into 10- or 12-bit characters.
To align the incoming bit stream to the proper character boundaries, the Framer must be enabled by asserting RFEN HIGH.
The Framer logic-block checks the incoming bit stream for the
unique pattern that defines the character boundaries. This
logic filter looks for the ANSI X3.230 symbol defined as a
“Special Character Comma” (K28.5 or C5.0). Once a K28.5 is
found, the Framer captures the offset of the data stream from
the present character boundaries, and resets the boundary to
reflect this new offset, thus framing the data to the correct
character boundaries.
Since noise induced errors can cause the incoming data to be
corrupted, and since many combinations of corrupt and legal
data can create and aliased K28.5, the framer may also be
disabled by setting RFEN LOW.
An option exists in the framer to require multiple K28.5
characters, meeting specific criteria, before the character
boundaries are reset. This multi-byte mode of the Framer is
enabled by keeping RFEN asserted HIGH for greater than
2048 character clock cycles. For multi-byte framing, the
receiver must find a pair of K28.5 characters, both on identical
10-bit boundaries, within a 5-character span (50 bits) before it
shifts its framing boundaries. This option greatly reduces the
probability of framing to aliased K28.5 characters while still
allowing many links to maintain synchronization.
Synchronous Decoded
In these modes, the Receive FIFO is bypassed, while the
10B/8B Decoder is enabled (FIFOBYP* is LOW and
ENCBYP* is HIGH). Framed characters output from the
Deserializer are decoded, and passed direct to the Receive
Output Register. The Deserializer operates synchronous to
the recovered bit-clock, which is divided by 10 generate the
output RXCLK clock. In this mode the RXRST* input is not
interpreted and may be biased either HIGH or LOW.
These modes are usually used for products that must meet
specific protocol requirements. New decoded characters are
provided at the RXDATA outputs once every rising edge of
RXCLK. When RXEMPTY* is deasserted along with the data,
Page 37 of 58
CY7C924ADX
it indicates that a valid character (as selected by
RXMODE[1:0]) is present at the RXDATA outputs. When
asserted it indicates that a C5.0 (K28.5) not kept by the current
RXMODE[1:0] setting is present on the RXDATA output bus.
Because the decoder is enabled, all received characters are
checked for compliance to the 8B/10B decoding rules.
other. When a C8.0 (K23.7) character is detected in the data
stream, the next character is written to the Receive FIFO along
with RXSOC set HIGH, and RXSC/D* and RXRVS set LOW.
When the character accompanying this marker is read from
the Receive FIFO with these same bits set, it indicates the start
of a cell or frame.
Output Register Mapping
Expanded Command
The RXDATA[11:0] output bus is mapped into a character
consisting of eight bits of data, one bit that carries violation
information, and an RXSC/D* bit that identifies the character
as either control or data.
The standard 8B/10B Character set contains all 256 possible
data characters, but only twelve Special Character codes. To
allow use of a larger selection of command codes, one Special
Character code was selected to expand the command set.
These bits have combinations that identify the meaning of the
remaining bits of the character. If RXRVS is HIGH and
RXSC/D* is HIGH the decoder outputs a C0.7, C1.7, C2.7 or
C4.7 in response to reception of either an SVS (C0.7)
character or other invalid character.
An Expanded Command marker is used to mark the
associated data as any one of 256 (28) possible commands
codes. When a C9.0 (K27.7) character is detected in the data
stream, the following character is written to the Receive FIFO
along with both RXSOC and RXSC/D* set HIGH, and RXRVS
set LOW. When the character accompanying this marker is
read from the Receive FIFO with these same bits set, it may
be used to indicate that the data on the RXDATA bus is an
Expanded Command.
Synchronous Undecoded
In this mode, both the Receive FIFO and the 10B/8B Decoder
are bypassed (FIFOBYP* and ENCBYP* are LOW), and data
passes directly from the Deserializer to the output register. The
Deserializer operates synchronous to the recovered bit-clock,
which is divided by 10 or 12 to generate the output RXCLK
clock. In this mode the RXRST* input is not interpreted and
may be biased either HIGH or LOW.
This mode is usually used for products containing external
decoders or descramblers that must meet specific protocol
requirements. New data is provided at the RXDATA outputs
once every rising edge of RXCLK. Received characters are
not checked for any specific coding requirements and no
decoding errors are reported.
Asynchronous Decoded
Asynchronous Decoded mode is the most powerful operating
mode of the CY7C924ADX HOTLink Receiver. Both the
Receive FIFO and the Decoder are enabled (FIFOBYP* and
ENCBYP* are HIGH). This allows reception of normal data
streams, while offering the added benefits of embedded cell
markers, an expanded command set, serial address support,
and in-band bypass-signaling (for flow control or other
purposes). All characters added to the data stream by the
transmitter to support these additional capabilities may be
automatically extracted by the Receive Control State Machine
in the CY7C924ADX Transceiver.
The deserializer operates synchronous to the recovered
bit-clock, which is divided by 10 to generate the Receive FIFO
write clock. When the Receive FIFO is addressed by AM* and
selected by RXEN*, characters are read from the FIFO using
the external RXCLK input.
Asynchronous Decoded mode support the same Output
Register mapping as the Synchronous Decoded mode.
Because both the Receive FIFO and Decoder are enabled, the
output FIFO may be read at any rate supported by the FIFO
(0 to 50MHz), however, if the Receive FIFO ever indicates a
full condition (RXFULL* is asserted), data may be lost.
Embedded Cell Marker
An embedded cell marker is used to mark the start of cells or
frames of information passed from one end of the link to the
Document #: 38-02008 Rev. *E
Serial Addressing
The CY7C924ADX receive path can be directed to accept all
characters, or to only accept that data specifically addressed
to it. This address control is managed through an embedded
Address Compare Register in the receiver logic. This register
supports either domain (multicast) or exact-match (unicast)
based compares on an address field received across the serial
link. When a C10.0 (K29.7) special code is received, the
immediately following data character contains the address
field that is compared with the receiver Serial Address
Register contents.
When the CY7C924ADX is configured for multicast address
matching, the received address field is compared as an OR of
a bit-wise AND with the Serial Address Register. A valid match
between any of the bits sets the switch to allow the following
data to be written into the Receive FIFO. If no matches are
found, the data is not written to the Receive FIFO and is
discarded.
When the CY7C924ADX is configured for unicast address
matching, the received address field is compared for an exact
match with the Serial Address Register. If an exact match is
found, a switch is set in the receiver to accept all following data
until the next serial address marker is found. If they do not
match, the data is not written to the Receive FIFO and is
discarded.
In-Band Bypass-Signaling
In-band bypass-signaling allows a signal to be received at the
local receiver without that signal having to pass through the
Receive FIFO.
When a C0.0 (K28.0) character is received, the RXINT output
is set HIGH. When a C3.0 (K28.3) character is received, the
RXINT output is set LOW. These special codes are generated
by forcing similar transitions into the TXINT input of the
CY7C924ADX HOTLink Transmitter sourcing the data stream.
This output may be used to transport a low data-rate signal
(like a serial RS-232/UART signal) across the interface,
without any significant impact on the actual data being transPage 38 of 58
CY7C924ADX
ported across the link. It may also be used to transparently
propagate FIFO flow-control information across the link by
directly connecting the RXHALF* flag of the local receiver to
the TXINT of the local transmitter. The RXINT at the remote
end of the link can then be connected to the TXHALT* input to
halt data transfers at the remote end of the link until the local
Receive FIFO has sufficient room to continue.
BIST Operation and Reporting
Asynchronous Byte-Packed
The CY7C924ADX HOTLink Transceiver incorporates the
same Built-In Self-Test (BIST) capability used with the
HOTLink
CY7B923/
CY7B933
and
HOTLink
II
CYP(V)15G0x0x families. This link diagnostic uses a Linear
Feedback Shift Register (LFSR) to generate a 511-character
repeating sequence that is compared, character-for-character,
at the receiver.
Asynchronous byte-packed mode contains the same features
as asynchronous decoded, but with support for 10-bit source
data (BYTE8/10* is LOW). The received characters are
decoded first back into 8-bit data characters, which are then
reassembled into 10-bit source data.
BIST mode is intended to check the entire high-speed serial
link at full link-speed, without the use of specialized and
expensive test equipment. The complete sequence of
characters used in BIST are documented in the HOTLink
Built-In Self-Test application note.
Because of the time difference involved with the packing and
unpacking operations, this mode can only be used with the
internal FIFOs enabled.
BIST Enable Inputs
When receiving extended commands, the larger 10-bit
character size enlarges the extended command space to 1024
(210) possible commands codes.
When receiving a serial address, the larger 10-bit character
size also increases the Serial Address Register to 10 bits. This
allows up to 10 separate domains for multicast addressing or
1024 unique addresses for unicast addressing.
Asynchronous Undecoded
In Asynchronous Undecoded modes, the Receive FIFO is
enabled (FIFOBYP* is HIGH and ENCBYP* is LOW). This
means that all characters received from the serial interface are
written to the Receive FIFO before being passed to the output
register. The Deserializer operates synchronous to the
recovered bit-clock, which is divided by 10 or 12 to generate
the Receive FIFO write clock. Data is read from the Receive
FIFO, using the RXCLK input clock, when addressed by AM*
and selected by RXEN*.
These modes are usually used for products containing
external decoders or descramblers, that must meet specific
protocol requirements. New data may be read from the
Receive FIFO any time that the FIFO status flags indicate a
non-empty condition (RXEMPTY* is deasserted). To ensure
that data is not lost through a FIFO overflow, the Receive FIFO
must be read faster than data is loaded into the Receive FIFO.
If the receiver is to provide framed characters, it is necessary
for the transmit end to include C5.0 (K28.5) characters in the
data stream. This can be done by:
• Operating the transmitter in encoded mode and writing C5.0
characters into the data stream
• Operating the transmitter in pre-encoded mode and writing
the 10-bit value for an encoded C5.0 character to the data
stream (1100000101 or 0011111010)
• Deasserting TXEN* when the transmitter is operated in
synchronous mode
• Asserting TXHALT*, or by allowing the transmit FIFO to go
empty when it is operated in asynchronous mode.
Document #: 38-02008 Rev. *E
There are separate BIST enable inputs for the transmit and
receive paths of the CY7C924ADX. These inputs are both
active LOW; i.e., BIST is enabled in its respective section of
the device when the BIST enable input is determined to be at
a logic-0 level. Both BIST enable inputs are asynchronous;
i.e., they are synchronized inside the CY7C924ADX to the
internal state machines.
BIST Transmit Path
The transmit path operation with BIST is controlled by the
TXBISTEN* input and overrides most other inputs (see
Figure 7). When the Transmit FIFO is enabled (not bypassed)
and TXBISTEN* is recognized internally, all reads from the
Transmit FIFO are suspended and the BIST generator is
enabled to sequence out the 511 character repeating BIST
sequence. If the Transmit Control State Machine was in the
middle of an atomic operation (e.g., sending an extended
command) the Data Character associated with the Special
Character code is transmitted prior to recognition of the
TXBISTEN* signal and suspension of FIFO data processing.
If the recognition occurs in the middle of a data field, the
following data is not transmitted at that time, but remains in the
Transmit FIFO. Once the TXBISTEN* signal is removed, the
data in the Transmit FIFO is again available for transmission.
To ensure proper data handling at the destination, the transmit
host controller should either use TXHALT* or TXSTOP* to
segment transmission of data at specific boundaries, or allow
the Transmit FIFO to completely empty before enabling BIST.
With transmit BIST enabled, the Transmit FIFO remains
available for loading of data. It may be written up to its normal
maximum limit while the BIST operation takes place. To allow
removal of stale data from the Transmit FIFO, it may also be
reset during a BIST operation. The reset operation proceeds
as documented, with the exception of the information
presented on the TXEMPTY* FIFO status flag. Since this flag
is used to present BIST loop status, it continues to reflect the
state of the transmit BIST loop status until TXBISTEN* is no
longer recognized internally. The completion of the reset
operation may still be monitored through the TXFULL* FIFO
status flag.
Page 39 of 58
CY7C924ADX
Figure 7. Built-In Self-Test Illustration, UTOPIA Mode
Start of TX BIST
BIST
LOOP
Don’t Care
REFCLK
LOW to enable FIFO Flags
LOW to enable RXRVS reads
Ignore these outputs
ERROR
Start of RX
BIST Wait
Start of RX
BIST match
Forced to indicate EMPTY by BIST
BIST
LOOP
Enable RX BIST
The TXEMPTY* flag, when used for transmit BIST progress
indication, continues to reflect the active HIGH or active LOW
settings determined by the UTOPIA or Cascade timing model
selected by EXTFIFO; i.e., when configured for the Cascade
timing model, the TXEMPTY* and TXFULL* FIFO flags are
active HIGH, when configured for the UTOPIA timing model
the TXEMPTY* and TXFULL* FIFO flags are active LOW. The
illustration in Figure 7 uses the UTOPIA conventions.
When TXBISTEN* is first recognized, the TXEMPTY* flag is
clocked to a reset state, regardless of the addressed state of
the Transmit FIFO (if AM* is LOW or not), but is not driven out
of the part unless AM* has been sampled asserted (LOW).
Following this, on each completed pass through the BIST loop,
the TXEMPTY* flag is set for one interface clock period
(TXCLK or REFCLK).
When the Transmit FIFO is enabled, the TXEMPTY* flag
remains set until the interface is addressed and the state of
TXEMPTY* has been observed. If the device is not addressed
(AM* is not sampled LOW), the flag remains set internally
regardless of the number of TXCLK clock cycles that are
processed. If the device status is not polled on a sufficiently
regular basis, it is possible for the host system to miss one or
more of these BIST loop indications.
A pass through the loop is defined as that condition where the
Encoder generates the D0.0 state that initiates the BIST loop.
Document #: 38-02008 Rev. *E
AM*
RXEN*
RXDATA[9:0]
RXSC/D*
RXSOC
RXRVS
RXEMPTY*
RXHALF*
RXFULL*
RXBISTEN*
RXCLK
OUTA±
OUTB±
CY7C924ADX
TXCLK
TXBISTEN*
TXEMPTY*
TXHALF*
TXFULL*
TXSVS
TXSOC
TXSC/D*
TXDATA[9:0]
TXEN*
Enable TX BIST
INA±
INB±
A/B*
HIGH to select A
Depending on the initial state of the BIST LFSR, the first pass
through the loop may occur at substantially less than 511
character periods. Following the first pass, as long as
TXBISTEN* remains LOW, all remaining passes are exactly
511 characters in length.
When the Transmit FIFO is bypassed, the interface is clocked
by the REFCLK signal instead of TXCLK. While the active or
asserted state of the TXEMPTY* signal is still controlled by the
EXTFIFO, the state of any completed BIST loops is no longer
preserved. Instead, the TXEMPTY* flag reflects the dynamic
state of the BIST loop progress, and is asserted only once
every 511 character periods. If the interface is not addressed
at the time that this occurs, then the FIFO status flags remain
in a High-Z state and the loop event is lost.
BIST Receive Path
The receive path operation in BIST is similar to that of the
transmit path. While the Receive FIFO is enabled and
RXBISTEN* is recognized internally, all writes to the Receive
FIFO are suspended. If the receiver had a previous serial
address match and was accepting data, no additional
characters are written to the Receive FIFO. If the receive data
state machine was in the middle of processing a
multi-character sequence or other atomic operation (e.g., a
start of cell marker and its associated data), the characters
Page 40 of 58
CY7C924ADX
associated with the atomic operation are discarded and not
written to the Receive FIFO.
Upon internal recognition of RXBISTEN*, the serial address
match flag is cleared such that once BIST has been disabled
and data is again being received, all received data is rejected
until a new serial address is again received that matches the
address match criteria.
Note. If the CY7C924ADX is set to match all data (all 1s in the
multicast match field), then it is not necessary to get an
address match before receiving data following the termination
of BIST. On reset or when programmed to this state, the device
ignores all serial address commands and matches all data.
Any data present in the Receive FIFO when RXBISTEN* is
recognized remains in the FIFO and cannot be read until the
BIST operation is complete. The data in the Receive FIFO
remains valid, but is NOT available for reading through the
host parallel interface. This is because the error output
indicator for receive BIST operations is the RXRVS signal,
which is normally part of the RXDATA bus. To prevent read
operations while BIST is in operation, the RXEMPTY* and
RXHALF* flags are forced to indicate an Empty condition.
Once RXBISTEN* has been removed and recognized internally, the Receive FIFO status flags are updated to reflect the
current content status of the Receive FIFO.
To allow removal of stale data from the Receive FIFO, it may
be reset during a BIST operation. The reset operation
proceeds as documented, with the exception that the
RXEMPTY* and RXHALF* status flags already indicate an
empty condition. The RXFULL* flag is used to present BIST
progress. The active state on RXFULL* and RXEMPTY* flags
remain controlled by the present operating mode and interface
timing model (UTOPIA or Cascade) as selected by EXTFIFO*.
When RXBISTEN* has been recognized, RXFULL* becomes
the receive BIST loop indicator, regardless of the logic state of
FIFOBYP*. When RXBISTEN* is first recognized with the
Receive FIFO enabled, the RXFULL* flag is clocked to a set
state, regardless of the addressed state of the Receive FIFO
(if AM* is sampled LOW or not). Following this, RXFULL*
remains set until the receiver detects the start of the BIST
pattern. Then RXFULL* is deasserted for the duration of the
BIST pattern, pulsing asserted for one RXCLK period on the
last symbol of each BIST loop. If 14 of 28 consecutive
characters are received in error, RXFULL* returns to the set
state until the start of a BIST sequence is again detected.
Just like the BIST status flag on the transmit data path, when
the Receive FIFO is enabled the RXFULL* flag captures the
asserted states, and keeps them until they are read. This
means that if the status flag is not read on a regular basis,
events may be lost.
The detection of errors is presented on the RXRVS output.
Unlike the RXFULL* FIFO status flag, the active state of this
output is not controlled by the EXTFIFO input. With the
Receive FIFO enabled, these outputs should operate the
same as the RXFULL* flag, with respect to preserving the
detection state of an error until it is read.
Unlike the RXFULL* flag, which only needs the CY7C924ADX
to be addressed (AM* sampled LOW by RXCLK) to enable the
RXFULL* three-state driver, and an RXCLK to “read” the flag,
the RXRVS output requires a selection (assertion of RXEN*
Document #: 38-02008 Rev. *E
while addressed) to enable the RXDATA bus three-state
drivers. The selection process is necessary to ensure that a
multi-PHY implementation does not enable multiple RXRVS
drivers at the same time.
When the Receive FIFO is bypassed, the interface is clocked
by the RXCLK output signal. While the active or asserted state
of the RXFULL* signal is still controlled by the EXTFIFO input,
the state of any completed BIST loops or detected errors are
no longer preserved. Instead, the RXFULL* flag reflects the
dynamic state of the BIST loop progress, and is asserted only
once every 511 character periods. If the interface is not
addressed at the time that this occurs, then the FIFO status
flags remain in a High-Z state and the loop event is lost. This
is also true of the RXRVS output, such that if the
CY7C924ADX receive path is not selected to enable the
RXDATA bus three-state drivers, the detection of a BIST
miscompare is lost.
BIST Three-state Control
When BIST is enabled on either the transmitter or the receiver,
the three-state enable signals for the BIST status flags and
error indicators work the same as for normal data processing.
The output drivers for the BIST status that is presented on
FIFO status flags are only enabled when AM* has been
sampled asserted (LOW) by the respective clock (TXCLK,
RXCLK, or REFCLK).
To access the BIST error information, it is necessary to
perform a read cycle of the addressed receiver. This means
that AM* must be LOW to allow a receiver address match
(Rx_Match) to exist, and RXEN* must then be asserted to
select the device. Because the part is in BIST, no data is read
from the FIFO, but the data bus is driven. This allows the
RXRVS indicator to be driven onto the RXDATA bus. So long
as RXEN* remains asserted, the receiver stays selected, the
data bus remains driven, and RXRVS has meaning.
Bus Interfacing
The parallel transmit and receive host interfaces to the
CY7C924ADX are configurable for either synchronous or
asynchronous operation. Each of these configurations
supports two selectable timing and control models of UTOPIA
or Cascade.
All asynchronous bus configurations have the internal
Transmit and Receive FIFOs enabled. This allows data to be
written or read from these FIFOs at any rate up to the
maximum 50-MHz clock rate of the FIFOs. All internal operations of the CY7C924ADX do not use the external TXCLK or
RXCLK, but instead make use of synthesized derivatives of
REFCLK for transmit path operations and a recovered
character clock for receive path operations.
All synchronous bus configurations require the bus interface
operations to be synchronous to REFCLK on the transmit path
and the recovered clock (output as RXCLK) on the receive
path. The internal FIFOs are bypassed in all synchronous
modes.
The two supported timing and control models are UTOPIA and
Cascade. These timing models take their name from their
default configuration. The UTOPIA timing model is based on
the ATM Forum UTOPIA interface standards. This timing
Page 41 of 58
CY7C924ADX
model is that of a FIFO with active LOW FIFO status flags and
read/write enables.
The Cascade timing model is a modification of the UTOPIA
configuration that changes the flags and FIFO read/write
enables to active HIGH. This model is present primarily to
allow depth expansion of the internal FIFO by direct coupling
to external CY7C42x5 synchronous FIFOs. To allow this direct
coupling, the FIFO flag active levels and cycle-to-cycle timing
between the transmit enable (TXEN*) and data latching are
modified to ensure correct data transfer.
These four configurations of bus operation and timing/control
can all be used with or without external FIFOs. Depending on
the specific mode selected, the amount of external hardware
necessary to properly couple the CY7C924ADX to state
machines or external FIFOs is minimal in all cases, and may
be zero if the proper configuration is selected.
UTOPIA Interface Background
The UTOPIA interface is defined by the ATM Forum as the bus
interface between the ATM and PHY layer devices of an ATM
system. This interface is defined as 8 or 16 bits wide, with the
latter reserved mainly for high-speed physical interfaces
(PHYs) such as 622 Mbps OC-12. Due to the limited speed
range of the CY7C924, only the 8-bit interface is implemented.
UTOPIA-1 was the original UTOPIA specification (created in
1993) which covers transport of:
• 155.52 Mbps (scrambled SONET/OC-3)
• 155.52 Mbps (8B/10B block coded at 194.4 MBaud)
• 100 Mbps (4B/5B encoded TAXI)
• 44.736 Mbps (DS-3/T3)
• 51.84 Mbps (OC-1)
The UTOPIA-1 interface has a maximum clock rate of 25 MHz.
All AC-timing and pin descriptions are covered in the
UTOPIA-1 Specification, Version 2.01.
UTOPIA-2 was created as an addendum to the UTOPIA-1
specification. In this revision, the parallel interface was
extended to both 33 MHz and 50 MHz to accommodate PCI
bus architectures in ATM designs. A method of addressing
was added to allow multiple devices (PHYs) to share a
common host bus. Also, a description of a management
interface was added (not supported by this device).
The CY7C924ADX contains all pins necessary to support the
UTOPIA-1 and, through use of an external address decoder,
can emulate the multi-PHY capability of a UTOPIA-2 interface.
The maximum bus speed supports the full 50 MHz I/O rate for
emerging high-performance systems.
UTOPIA Address Match and Selection
All actions on a UTOPIA-2 interface are controlled by the
Address Match and selection states of the interface. These
states control the read and write access to the Receive and
Transmit FIFOs, access to the FIFO status flags, reset of the
Transmit and Receive FIFOs, and read and write access to the
Serial Address Register. The CY7C924ADX supports the
concept of an “address match” through a single Address
Match (AM*) input.
Document #: 38-02008 Rev. *E
Address Match and FIFO Flag Access
The CY7C924ADX makes use of a single active-LOW
Address Match (AM*) to generate address-match conditions.
When this input is LOW it is equivalent to an ATM address
compare on both the TXADDR and RXADDR buses. This
allows multiple CY7C924ADX devices to share a common
bus, with device output three-state controls being managed by
either an address match condition (AM* sampled LOW), or by
a selection state.
The Transmit and Receive FIFO flag empty and FIFO full
output drivers are enabled in any TXCLK, REFCLK, or RXCLK
cycle following AM* being sampled asserted (LOW) by the
rising edge of the respective clock. The AM* input is sampled
separately by the clocks for the transmit and receive interfaces, which allows these clocks to operate at different clock
rates. An example of both Transmit and Receive FIFO flag
access is shown in Figure 8.
Figure 8. FIFO Flag Driver Enables
TXCLK
AM*
TXFULL*
Valid
Transmit Port Addressing
RXCLK
AM*
RXEMPTY*
Valid
Receive Port Addressing
When the Transmit FIFO is enabled (FIFOBYP* is HIGH) and
AM* is sampled LOW by the rising edge of TXCLK, the output
drivers for the TXFULL* and TXEMPTY* FIFO flags are
enabled. When AM* is sampled HIGH by the rising edge of
TXCLK, these same output drivers are disabled.
When the Transmit FIFO is bypassed (FIFOBYP* is LOW and
not in byte-packed mode) and AM* is sampled LOW by the
rising edge of REFCLK, the output drivers for the TXFULL*
and TXEMPTY* FIFO flags are enabled. When AM* is
sampled HIGH by the rising edge of REFCLK, the FIFO flag
output drivers are disabled.
When AM* is sampled LOW by the rising edge of RXCLK
(input or output), the output drivers for the RXFULL* and
RXEMPTY* FIFO flags are enabled. When AM* is sampled
HIGH by the rising edge of RXCLK, the FIFO flag output
drivers are disabled.
Page 42 of 58
CY7C924ADX
Device Selection
The concept of selection is used to control the access to the
transmit and receive parallel-data ports of the device. There
are three primary types of selection:
• Transmit data selection (with and without internal Transmit
FIFO)
• Receive data selection (with and without internal Receive
FIFO)
• Continuous selection (for either or both transmit and receive
interfaces)
In addition to these normal selection types, there are two
additional sequences that are used to control the internal
Transmit and Receive FIFOs reset operations, and to control
read/write access to the Serial Address Register:
• Transmit reset sequence
• Receive reset sequence (includes access to the Serial
Address Register)
Of these operations, the transmit data selection and transmit
reset sequence are mutually exclusive and cannot exist at the
same time. The receive data selection and receive reset
sequence are also mutually exclusive and cannot exist at the
same time. Either transmit operation can exist at the same
time as either receive operation.
All normal forms of selection require that an Address Match
condition must exist (AM* sampled LOW) either at the same
time as the selection control signal being sampled asserted,
or one or more clock cycles prior to the selection control signal
being sampled asserted.
Transmit Data Selection
Asynchronous With UTOPIA Timing and Control
(Transmit FIFO Enabled)
When AM* is sampled LOW and TXRST* is sampled HIGH by
the rising edge of TXCLK, a Tx_Match condition is generated.
This Tx_Match condition continues until AM* is sampled HIGH
or TXRST* is sampled LOW at the rising edge of TXCLK.
When a Tx_Match (or Tx_RstMatch) condition is present, the
TXEMPTY* and TXFULL* output drivers are enabled. When a
Tx_Match (or Tx_RstMatch) condition is not present, these
same drivers are disabled (High-Z).
The selection state of the Transmit FIFO is entered when a
Tx_Match condition is present, and TXEN* transitions from
HIGH to LOW. Once selected, the Transmit FIFO remains
selected until TXEN* is sampled HIGH by the rising edge of
TXCLK. In the selected state, data present on the TXDATA
inputs is captured and stored in the Transmit FIFO. This
transmit interface selection process is shown in Figure 9. For
the first TXEN* assertion, the TX_Match condition is not yet
present so the Transmitter is not selected. However, the
second TXEN* assertion meets this requirement and the
Transmitter selection is successful.
Figure 9. Transmit Selection with Transmit FIFO Enabled
TXCLK
TXRST*
AM*
[26]
Tx_Match
Note 27
TXEN*
Tx_Selected
[26]
TXDATA
D1
(UTOPIA Timing)
TXDATA
(Cascade Timing)
TXFULL*
Not Full
D2
D3
D1
D2
D3
Not Full
Note 27
Notes
26. Signals labeled in italics are internal to the CY7C924ADX.
27. Signals shown as dotted lines represent the differences in timing and active state of signals when operated in Cascade Timing.
Document #: 38-02008 Rev. *E
Page 43 of 58
CY7C924ADX
Synchronous With UTOPIA Timing and Control
(Transmit FIFO Bypassed)
When the Transmit FIFO is bypassed (FIFOBYP* is LOW and
not in byte-packed mode), the CY7C924ADX must still be
selected to write data into the Transmit Input Register.
Parallel TXDATA is clocked in and transmitted serially when
TXEN* is asserted. When TXEN* is deasserted, the TXDATA
bus contents are ignored and C5.0 idle characters are sent
instead.
AM* must be asserted to enable the TXFIFO flags. When AM*
is deasserted, the flags are High-Z.
When AM* is deasserted while TXEN* is enabled, the Transmit
TXDATA is still read in and transmitted, but the FIFO flags are
no longer enabled.
When data is not written to the Transmit Input Register, the
data stream is automatically padded with C5.0 (K28.5) SYNC
characters. If the 8B/10B Encoder is enabled, disparity
tracking allows the added C5.0 fill characters to follow all
8B/10B encoding rules. If the 8B/10B encoder is bypassed,
disparity tracking is disabled, and the transition between externally encoded data and internally generated C5.0 characters
may generate a running disparity error at the attached
receiver. The same error may occur at the transition between
the internal C5.0 characters and the resumption of externally
encoded data. When strings of contiguous C5.0 characters are
generated, each C5.0 has alternating running disparity with
the previous C5.0 character.
Receive Data Selection
generated. This Rx_Match condition continues until AM* is
sampled HIGH or RXRST* is sampled LOW at the rising edge
of RXCLK input. When an Rx_Match (or Rx_RstMatch)
condition is present, the RXEMPTY* and RXFULL* output
drivers are enabled. When an Rx_Match (or Rx_RstMatch)
condition is not present, these same drivers are disabled
(High-Z).
The selection state of the Receive FIFO is entered when an
Rx_Match condition is present, and RXEN* transitions from
HIGH to LOW. Once selected, the Receive FIFO remains
selected until RXEN* is sampled HIGH by the rising edge of
RXCLK input. The selected state initiates a read cycle from the
Receive FIFO and enables the Receive FIFO data onto the
RXDATA bus. This receive interface selection process is
shown in Figure 10. For the first RXEN* assertion, the
RX_Match condition is not present when RXEN* is asserted
so the Receiver is not selected. However, the second RXEN*
assertion occurs with an RX_Match condition present and the
Receiver selection is successful.
Synchronous With UTOPIA Timing and Control
(Receive FIFO Bypassed)
When the Receive FIFO is bypassed (FIFOBYP* is LOW and
not in a byte-packed mode), the CY7C924ADX must still be
selected to enable the output drivers for the RXDATA bus. With
the Receive FIFO bypassed, RXCLK becomes a synchronous
output clock operating at the character rate.
The Receive interface is selected when AM* is sampled
asserted and RXEN* is asserted at least one cycle later. Once
selected, it remains asserted until RXEN* is deasserted,
regardless of the state of AM*.
Asynchronous With UTOPIA Timing and Control
(Receive FIFO Enabled)
When AM* is sampled LOW and RXRST* is sampled HIGH by
the rising edge of RXCLK input, an Rx_Match condition is
Figure 10. Receive Selection with Receive FIFO Enabled
RXCLK
RXRST*
AM*
[26]
Rx_Match
RXEN
Rx_Selected
Note 27
[26]
RXDATA
D1
Not Empty
RXEMPTY
Document #: 38-02008 Rev. *E
D2
D3
Not Empty
Note 27
Page 44 of 58
CY7C924ADX
If RXEN* is deasserted when AM* is deasserted, AM* must
again be sampled LOW followed by RXEN* sampled low at
least one cycle later for the Receive interface to again be
selected. When the Receive interface is not selected, the
RXDATA[11:0] bus is High-Z.
The Receive FIFO flags depend only on the state of AM*.
When AM* is asserted, the flags are enabled. When AM* is
deasserted, the flags are High-Z.)
disabled (High-Z). The Receive FIFO reset Address Match is
shown in Figure 12.
Figure 12. Receive FIFO Reset Address Match
RXCLK
RXRST*
Continuous Selection
Continuous Selection is a specialized form of selection which
does not require sequenced assertion of AM* and TXEN* or
RXEN* to select the device for data transfers. In this
Continuous Selection mode, the AM* and associated TXEN*
or RXEN* enable signal must be asserted when the device is
powered up or during assertion of RESET*[1:0]. So long as
these signals remain asserted, the device remains selected
and data is accepted and presented on every clock cycle.
Note. The use of continuous selection makes it impossible to
reset the internal FIFOs, or to access the Serial Address
Register.
FIFO Reset Address Match
When AM* and TXRST* are both LOW, and this condition is
sampled by the rising edge of TXCLK, a Tx_RstMatch
condition is generated. This Tx_RstMatch condition continues
until AM* or TXRST* is sampled HIGH by the rising edge of
TXCLK. When a Tx_RstMatch (or Tx_Match) condition is
present, the TXEMPTY* and TXFULL* output drivers are
enabled (just as in a normal Tx_Match condition). When AM*
is not asserted, these same drivers are disabled (High-Z). The
Transmit FIFO reset Address Match is shown in Figure 11.
Note that although TXRST* remains LOW for more than one
clock cycle, the Tx_RstMatch does not because the AM*
signal is no longer asserted (LOW).
Figure 11. Transmit FIFO Reset Address Match
TXCLK
TXRST*
AM*
Tx_RstMatch
Tx_Match
AM*
Rx_RstMatch
Rx_Match
[26]
[26]
RXEMPTY
Valid Valid
Note that while the FIFO flags remain asserted for more than
one clock cycle, this is due to an Rx_Match condition, not a
continuation of the Rx_RstMatch.
FIFO Reset Sequence
On power-up, the Transmitter and Receiver FIFOs are cleared
automatically. If the usage of the FIFOs in specific operating
modes results in stale or unwanted data, this data can be
cleared by resetting the respective FIFO. Data in the Transmit
FIFO will empty automatically if it is enabled to read the FIFO
(assuming TXHALT* is not LOW). Stale received data can be
“flushed” by reading it, or the Receive FIFO can be reset to
remove the unwanted data.
The Transmit and Receive FIFOs are reset when the
Tx_RstMatch or Rx_RstMatch condition remains present for
eight consecutive clock cycles. Any disruption of the reset
sequence prior to reaching the eight cycle count, either by
removal of AM* or the respective TXRST* or RXRST* terminates the sequence and does not reset the FIFO. If the
associated TXEN* or RXEN* signals are asserted during the
reset, the relevant interface’s reset operation is inhibited until
the enable signal is deasserted. Because AM* must remain
asserted during the reset sequence, the addressed FIFO flags
remain driven during the entire sequence.
[26]
Transmit FIFO Reset Sequence
[26]
TXFULL*
Valid
When AM* and RXRST* are both LOW, and this condition is
sampled by the rising edge of RXCLK, an Rx_RstMatch
condition is generated. This Rx_RstMatch condition continues
until AM* or RXRST* is sampled HIGH, at the rising edge of
RXCLK. When an Rx_RstMatch (or Rx_Match) condition is
present, the RXEMPTY* and RXFULL* output drivers are
enabled. When AM* is not asserted these same drivers are
Document #: 38-02008 Rev. *E
The Transmit FIFO reset sequence is started when TXRST*
and AM* are first sampled LOW by the rising edge of TXCLK.
If TXEN* is asserted (sampled HIGH for UTOPIA timing or
LOW for Cascade timing), the reset sequence is inhibited until
it is removed.
When a Transmit FIFO reset sequence is enabled and has
been active for at least eight TXCLK cycles, a Transmit FIFO
reset operation is started. To show this progress, the Transmit
FIFO flags are forced to indicate a FULL* condition
(TXEMPTY* is deasserted, and both TXHALF* and TXFULL*
are asserted).
Note. The FIFO Full state forced by the reset operation is
different from a Full state caused by normal FIFO data writes.
For normal FIFO write operations, when Full is first asserted,
Page 45 of 58
CY7C924ADX
the Transmit FIFO can still accept up to eight additional writes
of data. When a Full state is asserted due to a Transmit FIFO
reset operation, the FIFO will not accept any additional data.
This FIFO reset operation is not allowed to progress within the
device until the external reset condition is removed. This can
occur by deasserting TXRST* or AM*. If AM* is deasserted
(HIGH) to remove the reset condition, the Transmit FIFO flag’s
drivers are disabled, and the Transmit FIFO must be
addressed at a later time to validate completion of the Transmit
FIFO reset. If TXRST* is deasserted (HIGH) to remove the
reset condition, the Tx_RstMatch is changed to a Tx_Match,
and the Transmit FIFO status flags remain driven.
The Transmit FIFO reset operation is complete when the
Transmit FIFO flags indicate an Empty state (TXEMPTY* is
asserted and both TXHALF* and TXFULL* are deasserted). A
valid Transmit FIFO reset sequence is shown in Figure 13.
Figure 14 on page 47 shows a sequence of input signals which
does not produce a FIFO reset. In this case TXEN* was
asserted to select the a Transmit FIFO for data transfers.
Because TXEN* remains active, the assertion of AM* and
TXRST* does not initiate a reset operation. This is shown by
the TXFULL* flag remaining HIGH (deasserted) following what
would be the normal expiration of the eight-state reset counter.
Receive FIFO Reset Sequence
The Receive FIFO reset sequence operates similarly to the
Transmit FIFO reset sequence. The same requirements exist
for the assertion state of RXRST* and selection of the interface
through AM*. A sample Receive FIFO reset sequence is
shown in Figure 15 on page 47. Upon recognition of a Receive
FIFO reset, the Receive FIFO flags are forced to indicate an
Empty state to prohibit additional reads from the FIFO. Unlike
the Transmit FIFO, where the internal completion of the reset
operation is shown by first going Full and later going Empty
when the internal reset is complete, there is no secondary
indication of the completion of the internal reset of the Receive
FIFO. The Receive FIFO is usable as soon as new data is
placed into it by the Receive Control State Machine.
When a Receive FIFO reset sequence is enabled and has
been active for at least eight RXCLK cycles, a Receive FIFO
reset operation is started. This FIFO reset operation is not
allowed to progress within the device until the associated
RXRST* or AM* signal is sampled deasserted. Following
deassertion of RXRST* (which starts the FIFO reset
operation), selection of the device for normal data transfers is
inhibited during the immediately following RXCLK clock cycle.
If a selection of the receive interface is attempted during this
immediately following cycle (by asserting RXEN*), the
selection is ignored, and the device remains unselected until
RXEN* is deasserted, and reasserted in a following RXCLK
cycle.
Figure 13. Transmit FIFO Reset Sequence
TXCLK
TXRST*
TXEN*
Note 27
AM*
Tx_RstMatch
Tx_Match
Tx_FIFO_Reset
[26]
[26]
[26]
TXFULL*
Note 27
Not Full
TXEMPTY*
Note 27
Not Empty
Document #: 38-02008 Rev. *E
Full
Not Full
Empty
Page 46 of 58
CY7C924ADX
Figure 14. Invalid Transmit FIFO Reset Sequence with TXEN* Asserted
TXCLK
TXRST*
TXEN*
Note 27
AM*
[26]
Tx_RstMatch
[26]
Tx_Match
Tx_FIFO_Reset
[26]
TXFULL*
Note 27
Not Full
Figure 15. Receive FIFO Reset Sequence
RXCLK
RXRST*
RXEN*
Note 27
AM*
[26]
Rx_RstMatch
Rx_Match
Rx_FIFO_Reset
[26]
[26]
RXEMPTY*
Document #: 38-02008 Rev. *E
Note 27
Not Empty
Empty
Page 47 of 58
CY7C924ADX
Serial Address Register Access
The Serial Address Register in the CY7B924ADX is accessed
through the RXDATA bus. This Serial Address Register can
only be accessed in UTOPIA mode (EXTFIFO = L). This
register can be both written and read, and is accessed by
asserting RXRST* to address the register in the device instead
of the normal Receive FIFO data. Within this alternate address
space, the RXRVS signal is an input at all times, and is used
to select between read (RXRVS is HIGH) and write (RXRVS
is LOW) operations on the Serial Address Register.
The Serial Address Register is the same size as the 8- or 10-bit
data width selected by BYTE8/10*. It can be set to match
domain or multicast addresses by the level on RXSC/D*. If
RXS/D* is LOW when the Serial Address Register is written, it
becomes the Multicast address register and declares a match
if at least one bit matches the equivalent bit in the incoming
Address character. If RXSC/D* is HIGH when the Serial
Address Register is written, it becomes the Unicast address
register and defines a match only if all of the bits match the
incoming Address character.
This register mapping is shown in Figure 6 on page 25.
Accessing Serial Address Register
To access the Serial Address Register in the CY7B924ADX,
an Rx_RstMatch condition must first be generated by the
combined assertion of AM* and RXRST* and the device must
be in UTOPIA timing mode (EXTFIFO = L). RXEN* is then
used as the data strobe signal to initiate either a read or write
cycle to the RXDATA bus. If RXRVS is HIGH at the time of the
RXEN* data strobe, a register read operation takes place. If
RXRVS is LOW at the time of the RXEN* data strobe, a
register write operation takes place.
The RXSC/D* input is used in conjunction with RXDATA[9:0]
or RXDATA[7:0] to select the operational mode of the Serial
Address Register (Unicast or Multicast)
Register write and read operations are shown in Figure 16. If
the serial address register write and read operations are both
performed without deasserting RXRST* for at more than
seven cycles, then RXRST* will still not extend to the
requirement for a reset and the Receive FIFO will not be reset.
FIFO Reset, Serial Address Register Access and Continuous
Selection
When configured for continuous selection (AM* asserted with
TXEN* always enabled, or AM* asserted with RXEN* always
enabled), it is not possible to reset the Transmit and Receive
FIFOs. It is also not possible to write to the Serial Address
Register without deselecting the Receive FIFO interface.
X3.230 Codes and Notation Conventions
Information to be transmitted over a serial link is encoded eight
bits at a time into a 10-bit Transmission Character and then
sent serially, bit by bit. Information received over a serial link
is collected ten bits at a time, and those Transmission
Characters that are used for data (Data Characters) are
decoded into the correct eight-bit codes. The 10-bit Transmission Code supports all 256 8-bit combinations. Some of the
remaining Transmission Characters (Special Characters) are
used for functions other than data transmission.
The primary rationale for use of a Transmission Code is to
improve the transmission characteristics of a serial link. The
encoding defined by the Transmission Code ensures that sufficient transitions are present in the serial bit stream to make
clock recovery possible at the Receiver. Such encoding also
greatly increases the likelihood of detecting any single or
multiple bit errors that may occur during transmission and
reception of information. In addition, some Special Characters
of the Transmission Code selected by Fibre Channel Standard
consist of a distinct and easily recognizable bit pattern (the
Special Character Comma) that assists a Receiver in
achieving word alignment on the incoming bit stream.
Figure 16. Serial Address Register Access
RXCLK
RXRST*
AM*
RXEN*
RXRVS
(R/W input)
Rx_RstMatch
Rx_FIFO_Reset
[26]
[26]
Write Register
Read Register
RXDATA
RXSC/D*
Document #: 38-02008 Rev. *E
Page 48 of 58
CY7C924ADX
Notation Conventions
The documentation for the 8B/10B Transmission Code uses
letter notation for the bits in an 8-bit byte. Fibre Channel
Standard notation uses a bit notation of A, B, C, D, E, F, G, H
for the 8-bit byte for the raw 8-bit data, and the letters a, b, c,
d, e, i, f, g, h, j for encoded 10-bit data. There is a correspondence between bit A and bit a, B and b, C and c, D and d, E
and e, F and f, G and g, and H and h. Bits i and j are derived,
respectively, from (A,B,C,D,E) and (F,G,H).
The bit labeled A in the description of the 8B/10B Transmission
Code corresponds to bit 0 in the numbering scheme of the
FC-2 specification, B corresponds to bit 1, as shown here:
FC-2 bit designation—
7 6 5 4 3 2 1 0
HOTLink TX/RX designation— 7 6 5 4 3 2 1 0
8B/10B bit designation—
H G F E D C B A
To clarify this correspondence, the following example shows
the conversion from an FC-2 Valid Data Byte to a Transmission
Character (using 8B/10B Transmission Code notation):
FC-2 45
Bits: 7654 3210
0100 0101
Converted to 8B/10B notation (note carefully that the order of
bits is reversed):
Data Byte Name
D5.2
Bits: ABCDE FGH
10100 010
Translated to a transmission Character in the 8B/10B Transmission Code:
Bits: abcdeifghj
1010010101
Each valid Transmission Character of the 8B/10B Transmission Code has been given a name using the following
convention: cxx.y, where c is used to show whether the Transmission Character is a Data Character (c is set to D, and the
SC/D* pin is LOW) or a Special Character (c is set to K, and the
SC/D* pin is HIGH). When c is set to D, xx is the decimal value of
the binary number composed of the bits E, D, C, B, and A in that
order, and the y is the decimal value of the binary number
composed of the bits H, G, and F in that order. When c is set to K,
xx and y are derived by comparing the encoded bit patterns of the
Special Character to those patterns derived from encoded Valid
Data bytes and selecting the names of the patterns most similar to
the encoded bit patterns of the Special Character.
Under the above conventions, the Transmission Character
used for the examples above, is referred to by the name D5.2.
The Special Character K29.7 is so named because the first six
bits (abcdei) of this character make up a bit pattern similar to
that resulting from the encoding of the unencoded 11101
pattern (29), and because the second four bits (fghj) make up
a bit pattern similar to that resulting from the encoding of the
unencoded 111 pattern (7).
Note. This definition of the 10-bit Transmission Code is based
on (and is in basic agreement with) the following references,
which describe the same 10-bit transmission code.
A.X. Widmer and P.A. Franaszek. “A DC-Balanced, Partitioned-Block, 8B/10B Transmission Code” IBM Journal of
Research and Development, 27, No. 5: 440-451 (September,
1983).
Document #: 38-02008 Rev. *E
U.S. Patent 4,486,739. Peter A. Franaszek and Albert X.
Widmer. “Byte-Oriented DC Balanced (0.4) 8B/10B Partitioned Block Transmission Code” (December 4, 1984).
Fibre Channel Physical and Signaling Interface (ANS
X3.230−1994 ANSI FC−PH Standard).
IBM Enterprise Systems Architecture/390 ESCON I/O
Interface (document number SA22−7202).
8B/10B Transmission Code
The following information describes how the tables are used
for both generating valid Transmission Characters (encoding)
and checking the validity of received Transmission Characters
(decoding). It also specifies the ordering rules to be followed
when transmitting the bits within a character and the
characters within the higher-level constructs specified by the
standard.
Transmission Order
Within the definition of the 8B/10B Transmission Code, the bit
positions of the Transmission Characters are labeled a, b, c,
d, e, i, f, g, h, j. Bit “a” is transmitted first followed by bits b, c,
d, e, i, f, g, h, and j in that order. (Note that bit i is transmitted
between bit e and bit f, rather than in alphabetical order.)
Valid and Invalid Transmission Characters
The following tables define the valid Data Characters and valid
Special Characters (K characters), respectively. The tables
are used for both generating valid Transmission Characters
(encoding) and checking the validity of received Transmission
Characters (decoding). In the tables, each Valid-Data-byte or
Special-Character-code entry has two columns that represent
two (not necessarily different) Transmission Characters. The
two columns correspond to the current value of the running
disparity (“Current RD−” or “Current RD+”). Running disparity
is a binary parameter with either the value negative (−) or the
value positive (+).
After powering on, the Transmitter may assume either a
positive or negative value for its initial running disparity. Upon
transmission of any Transmission Character, the transmitter
will select the proper version of the Transmission Character
based on the current running disparity value, and the Transmitter calculates a new value for its running disparity based on
the contents of the transmitted character. Special Character
codes C1.7 and C2.7 can be used to force the transmission of
a specific Special Character with a specific running disparity
as required for some special sequences in X3.230.
After powering on, the Receiver may assume either a positive
or negative value for its initial running disparity. Upon reception
of any Transmission Character, the Receiver decides whether
the Transmission Character is valid or invalid according to the
following rules and tables and calculates a new value for its
Running Disparity based on the contents of the received
character.
The following rules for running disparity are used to calculate
the new running-disparity value for Transmission Characters
that have been transmitted (Transmitter’s running disparity)
and that have been received (Receiver’s running disparity).
Running disparity for a Transmission Character is calculated
from sub-blocks, where the first six bits (abcdei) form one
sub-block and the second four bits (fghj) form the other
Page 49 of 58
CY7C924ADX
sub-block. Running disparity at the beginning of the 6-bit
sub-block is the running disparity at the end of the previous
Transmission Character. Running disparity at the beginning of
the 4-bit sub-block is the running disparity at the end of the
6-bit sub-block. Running disparity at the end of the Transmission Character is the running disparity at the end of the
4-bit sub-block.
Table 9. Valid Transmission Characters
Data
Byte Name
Running disparity for the sub-blocks is calculated as follows:
1. Running disparity at the end of any sub-block is positive if
the sub-block contains more ones than zeros. It is also positive at the end of the 6-bit sub-block if the 6-bit sub-block
is 000111, and it is positive at the end of the 4-bit sub-block
if the 4-bit sub-block is 0011.
2. Running disparity at the end of any sub-block is negative if
the sub-block contains more zeros than ones. It is also
negative at the end of the 6-bit sub-block if the 6-bit
sub-block is 111000, and it is negative at the end of the 4-bit
sub-block if the 4-bit sub-block is 1100.
3. Otherwise, running disparity at the end of the sub-block is
the same as at the beginning of the sub-block.
TXIN or RXOUT
Hex Value
765
43210
D0.0
000
00000
00
D1.0
000
00001
01
D2.0
000
00010
02
.
.
.
.
.
.
.
.
D5.2
010
000101
45
.
.
.
.
.
.
.
.
D30.7
111
11110
FE
D31.7
111
11111
FF
Use of the Tables for Checking the Validity of Received
Transmission Characters
Use of the Tables for Generating Transmission Characters
The column corresponding to the current value of the
Receiver’s running disparity is searched for the received
Transmission Character. If the received Transmission
Character is found in the proper column, then the Transmission Character is valid and the associated Data byte or
Special Character code is determined (decoded). If the
received Transmission Character is not found in that column,
then the Transmission Character is invalid. This is called a
code violation. Independent of the Transmission Character’s
validity, the received Transmission Character is used to
calculate a new value of running disparity. The new value is
used as the Receiver’s current running disparity for the next
received Transmission Character.Detection of a code violation
does not necessarily show that the Transmission Character in
which the code violation was detected is in error. Code violations may result from a prior error that altered the running
disparity of the bit stream which did not result in a detectable
error at the Transmission Character in which the error
occurred. Table 10 shows an example of this behavior.
The appropriate encoding for the Valid Data byte or the Special
Character byte into a Transmission Character is listed in the
character encoding Table 11 and Table 12. The current value
of the Transmitter’s running disparity is used to select the
Transmission Character from its corresponding column. For
each Transmission Character transmitted, a new value of the
running disparity is calculated. This new value is used as the
Transmitter’s current running disparity for the next Valid Data
byte or Special Character byte to be encoded and transmitted.
Table 9 shows naming notations and examples of valid transmission characters.
Table 10.Code Violations Resulting from Prior Errors
RD
Character
RD
Character
RD
Character
RD
–
D21.1
–
D10.2
–
D23.5
+
Transmitted bit stream
–
101010 1001
–
010101 0101
–
111010 1010
+
Bit stream after error
–
101010 1011
+
010101 0101
+
111010 1010
+
Decoded data character
–
D21.0
+
D10.2
+
Code Violation
+
Transmitted data character
Document #: 38-02008 Rev. *E
Page 50 of 58
CY7C924ADX
Table 11.Valid Data Characters (TXSC/D* = LOW, RXSC/D* = LOW)
Data
Byte
Name
Bits
Current RD−
Current RD+
Bits
Current RD−
Current RD+
abcdei fghj
Data
Byte
Name
HGF EDCBA
abcdei fghj
HGF EDCBA
abcdei fghj
abcdei fghj
D0.0
000 00000
100111 0100
011000 1011
D0.1
001 00000
100111 1001
011000 1001
D1.0
000 00001
011101 0100
100010 1011
D1.1
001 00001
011101 1001
100010 1001
D2.0
000 00010
101101 0100
010010 1011
D2.1
001 00010
101101 1001
010010 1001
D3.0
000 00011
110001 1011
110001 0100
D3.1
001 00011
110001 1001
110001 1001
D4.0
000 00100
110101 0100
001010 1011
D4.1
001 00100
110101 1001
001010 1001
D5.0
000 00101
101001 1011
101001 0100
D5.1
001 00101
101001 1001
101001 1001
D6.0
000 00110
011001 1011
011001 0100
D6.1
001 00110
011001 1001
011001 1001
D7.0
000 00111
111000 1011
000111 0100
D7.1
001 00111
111000 1001
000111 1001
D8.0
000 01000
111001 0100
000110 1011
D8.1
001 01000
111001 1001
000110 1001
D9.0
000 01001
100101 1011
100101 0100
D9.1
001 01001
100101 1001
100101 1001
D10.0
000 01010
010101 1011
010101 0100
D10.1
001 01010
010101 1001
010101 1001
D11.0
000 01011
110100 1011
110100 0100
D11.1
001 01011
110100 1001
110100 1001
D12.0
000 01100
001101 1011
001101 0100
D12.1
001 01100
001101 1001
001101 1001
D13.0
000 01101
101100 1011
101100 0100
D13.1
001 01101
101100 1001
101100 1001
D14.0
000 01110
011100 1011
011100 0100
D14.1
001 01110
011100 1001
011100 1001
D15.0
000 01111
010111 0100
101000 1011
D15.1
001 01111
010111 1001
101000 1001
D16.0
000 10000
011011 0100
100100 1011
D16.1
001 10000
011011 1001
100100 1001
D17.0
000 10001
100011 1011
100011 0100
D17.1
001 10001
100011 1001
100011 1001
D18.0
000 10010
010011 1011
010011 0100
D18.1
001 10010
010011 1001
010011 1001
D19.0
000 10011
110010 1011
110010 0100
D19.1
001 10011
110010 1001
110010 1001
D20.0
000 10100
001011 1011
001011 0100
D20.1
001 10100
001011 1001
001011 1001
D21.0
000 10101
101010 1011
101010 0100
D21.1
001 10101
101010 1001
101010 1001
D22.0
000 10110
011010 1011
011010 0100
D22.1
001 10110
011010 1001
011010 1001
D23.0
000 10111
111010 0100
000101 1011
D23.1
001 10111
111010 1001
000101 1001
D24.0
000 11000
110011 0100
001100 1011
D24.1
001 11000
110011 1001
001100 1001
D25.0
000 11001
100110 1011
100110 0100
D25.1
001 11001
100110 1001
100110 1001
D26.0
000 11010
010110 1011
010110 0100
D26.1
001 11010
010110 1001
010110 1001
D27.0
000 11011
110110 0100
001001 1011
D27.1
001 11011
110110 1001
001001 1001
D28.0
000 11100
001110 1011
001110 0100
D28.1
001 11100
001110 1001
001110 1001
D29.0
000 11101
101110 0100
010001 1011
D29.1
001 11101
101110 1001
010001 1001
D30.0
000 11110
011110 0100
100001 1011
D30.1
001 11110
011110 1001
100001 1001
D31.0
000 11111
101011 0100
010100 1011
D31.1
001 11111
101011 1001
010100 1001
D0.2
010 00000
100111 0101
011000 0101
D0.3
011 00000
100111 0011
011000 1100
D1.2
010 00001
011101 0101
100010 0101
D1.3
011 00001
011101 0011
100010 1100
D2.2
010 00010
101101 0101
010010 0101
D2.3
011 00010
101101 0011
010010 1100
D3.2
010 00011
110001 0101
110001 0101
D3.3
011 00011
110001 1100
110001 0011
Document #: 38-02008 Rev. *E
Page 51 of 58
CY7C924ADX
Table 11.Valid Data Characters (TXSC/D* = LOW, RXSC/D* = LOW) (continued)
Data
Byte
Name
Bits
Current RD−
Current RD+
Bits
Current RD−
Current RD+
abcdei fghj
Data
Byte
Name
HGF EDCBA
abcdei fghj
HGF EDCBA
abcdei fghj
abcdei fghj
D4.2
010 00100
110101 0101
001010 0101
D4.3
011 00100
110101 0011
001010 1100
D5.2
010 00101
101001 0101
101001 0101
D5.3
011 00101
101001 1100
101001 0011
D6.2
010 00110
011001 0101
011001 0101
D6.3
011 00110
011001 1100
011001 0011
D7.2
010 00111
111000 0101
000111 0101
D7.3
011 00111
111000 1100
000111 0011
D8.2
010 01000
111001 0101
000110 0101
D8.3
011 01000
111001 0011
000110 1100
D9.2
010 01001
100101 0101
100101 0101
D9.3
011 01001
100101 1100
100101 0011
D10.2
010 01010
010101 0101
010101 0101
D10.3
011 01010
010101 1100
010101 0011
D11.2
010 01011
110100 0101
110100 0101
D11.3
011 01011
110100 1100
110100 0011
D12.2
010 01100
001101 0101
001101 0101
D12.3
011 01100
001101 1100
001101 0011
D13.2
010 01101
101100 0101
101100 0101
D13.3
011 01101
101100 1100
101100 0011
D14.2
010 01110
011100 0101
011100 0101
D14.3
011 01110
011100 1100
011100 0011
D15.2
010 01111
010111 0101
101000 0101
D15.3
011 01111
010111 0011
101000 1100
D16.2
010 10000
011011 0101
100100 0101
D16.3
011 10000
011011 0011
100100 1100
D17.2
010 10001
100011 0101
100011 0101
D17.3
011 10001
100011 1100
100011 0011
D18.2
010 10010
010011 0101
010011 0101
D18.3
011 10010
010011 1100
010011 0011
D19.2
010 10011
110010 0101
110010 0101
D19.3
011 10011
110010 1100
110010 0011
D20.2
010 10100
001011 0101
001011 0101
D20.3
011 10100
001011 1100
001011 0011
D21.2
010 10101
101010 0101
101010 0101
D21.3
011 10101
101010 1100
101010 0011
D22.2
010 10110
011010 0101
011010 0101
D22.3
011 10110
011010 1100
011010 0011
D23.2
010 10111
111010 0101
000101 0101
D23.3
011 10111
111010 0011
000101 1100
D24.2
010 11000
110011 0101
001100 0101
D24.3
011 11000
110011 0011
001100 1100
D25.2
010 11001
100110 0101
100110 0101
D25.3
011 11001
100110 1100
100110 0011
D26.2
010 11010
010110 0101
010110 0101
D26.3
011 11010
010110 1100
010110 0011
D27.2
010 11011
110110 0101
001001 0101
D27.3
011 11011
110110 0011
001001 1100
D28.2
010 11100
001110 0101
001110 0101
D28.3
011 11100
001110 1100
001110 0011
D29.2
010 11101
101110 0101
010001 0101
D29.3
011 11101
101110 0011
010001 1100
D30.2
010 11110
011110 0101
100001 0101
D30.3
011 11110
011110 0011
100001 1100
D31.2
010 11111
101011 0101
010100 0101
D31.3
011 11111
101011 0011
010100 1100
D0.4
100 00000
100111 0010
011000 1101
D0.5
101 00000
100111 1010
011000 1010
D1.4
100 00001
011101 0010
100010 1101
D1.5
101 00001
011101 1010
100010 1010
D2.4
100 00010
101101 0010
010010 1101
D2.5
101 00010
101101 1010
010010 1010
D3.4
100 00011
110001 1101
110001 0010
D3.5
101 00011
110001 1010
110001 1010
D4.4
100 00100
110101 0010
001010 1101
D4.5
101 00100
110101 1010
001010 1010
D5.4
100 00101
101001 1101
101001 0010
D5.5
101 00101
101001 1010
101001 1010
D6.4
100 00110
011001 1101
011001 0010
D6.5
101 00110
011001 1010
011001 1010
D7.4
100 00111
111000 1101
000111 0010
D7.5
101 00111
111000 1010
000111 1010
Document #: 38-02008 Rev. *E
Page 52 of 58
CY7C924ADX
Table 11.Valid Data Characters (TXSC/D* = LOW, RXSC/D* = LOW) (continued)
Data
Byte
Name
Bits
Current RD−
Current RD+
Bits
Current RD−
Current RD+
abcdei fghj
Data
Byte
Name
HGF EDCBA
abcdei fghj
HGF EDCBA
abcdei fghj
abcdei fghj
D8.4
100 01000
111001 0010
000110 1101
D8.5
101 01000
111001 1010
000110 1010
D9.4
100 01001
100101 1101
100101 0010
D9.5
101 01001
100101 1010
100101 1010
D10.4
100 01010
010101 1101
010101 0010
D10.5
101 01010
010101 1010
010101 1010
D11.4
100 01011
110100 1101
110100 0010
D11.5
101 01011
110100 1010
110100 1010
D12.4
100 01100
001101 1101
001101 0010
D12.5
101 01100
001101 1010
001101 1010
D13.4
100 01101
101100 1101
101100 0010
D13.5
101 01101
101100 1010
101100 1010
D14.4
100 01110
011100 1101
011100 0010
D14.5
101 01110
011100 1010
011100 1010
D15.4
100 01111
010111 0010
101000 1101
D15.5
101 01111
010111 1010
101000 1010
D16.4
100 10000
011011 0010
100100 1101
D16.5
101 10000
011011 1010
100100 1010
D17.4
100 10001
100011 1101
100011 0010
D17.5
101 10001
100011 1010
100011 1010
D18.4
100 10010
010011 1101
010011 0010
D18.5
101 10010
010011 1010
010011 1010
D19.4
100 10011
110010 1101
110010 0010
D19.5
101 10011
110010 1010
110010 1010
D20.4
100 10100
001011 1101
001011 0010
D20.5
101 10100
001011 1010
001011 1010
D21.4
100 10101
101010 1101
101010 0010
D21.5
101 10101
101010 1010
101010 1010
D22.4
100 10110
011010 1101
011010 0010
D22.5
101 10110
011010 1010
011010 1010
D23.4
100 10111
111010 0010
000101 1101
D23.5
101 10111
111010 1010
000101 1010
D24.4
100 11000
110011 0010
001100 1101
D24.5
101 11000
110011 1010
001100 1010
D25.4
100 11001
100110 1101
100110 0010
D25.5
101 11001
100110 1010
100110 1010
D26.4
100 11010
010110 1101
010110 0010
D26.5
101 11010
010110 1010
010110 1010
D27.4
100 11011
110110 0010
001001 1101
D27.5
101 11011
110110 1010
001001 1010
D28.4
100 11100
001110 1101
001110 0010
D28.5
101 11100
001110 1010
001110 1010
D29.4
100 11101
101110 0010
010001 1101
D29.5
101 11101
101110 1010
010001 1010
D30.4
100 11110
011110 0010
100001 1101
D30.5
101 11110
011110 1010
100001 1010
D31.4
100 11111
101011 0010
010100 1101
D31.5
101 11111
101011 1010
010100 1010
D0.6
110 00000
100111 0110
011000 0110
D0.7
111 00000
100111 0001
011000 1110
D1.6
110 00001
011101 0110
100010 0110
D1.7
111 00001
011101 0001
100010 1110
D2.6
110 00010
101101 0110
010010 0110
D2.7
111 00010
101101 0001
010010 1110
D3.6
110 00011
110001 0110
110001 0110
D3.7
111 00011
110001 1110
110001 0001
D4.6
110 00100
110101 0110
001010 0110
D4.7
111 00100
110101 0001
001010 1110
D5.6
110 00101
101001 0110
101001 0110
D5.7
111 00101
101001 1110
101001 0001
D6.6
110 00110
011001 0110
011001 0110
D6.7
111 00110
011001 1110
011001 0001
D7.6
110 00111
111000 0110
000111 0110
D7.7
111 00111
111000 1110
000111 0001
D8.6
110 01000
111001 0110
000110 0110
D8.7
111 01000
111001 0001
000110 1110
D9.6
110 01001
100101 0110
100101 0110
D9.7
111 01001
100101 1110
100101 0001
D10.6
110 01010
010101 0110
010101 0110
D10.7
111 01010
010101 1110
010101 0001
D11.6
110 01011
110100 0110
110100 0110
D11.7
111 01011
110100 1110
110100 1000
Document #: 38-02008 Rev. *E
Page 53 of 58
CY7C924ADX
Table 11.Valid Data Characters (TXSC/D* = LOW, RXSC/D* = LOW) (continued)
Data
Byte
Name
Bits
Current RD−
Current RD+
Bits
Current RD−
Current RD+
abcdei fghj
Data
Byte
Name
HGF EDCBA
abcdei fghj
HGF EDCBA
abcdei fghj
abcdei fghj
D12.6
110 01100
001101 0110
001101 0110
D12.7
111 01100
001101 1110
001101 0001
D13.6
110 01101
101100 0110
101100 0110
D13.7
111 01101
101100 1110
101100 1000
D14.6
110 01110
011100 0110
011100 0110
D14.7
111 01110
011100 1110
011100 1000
D15.6
110 01111
010111 0110
101000 0110
D15.7
111 01111
010111 0001
101000 1110
D16.6
110 10000
011011 0110
100100 0110
D16.7
111 10000
011011 0001
100100 1110
D17.6
110 10001
100011 0110
100011 0110
D17.7
111 10001
100011 0111
100011 0001
D18.6
110 10010
010011 0110
010011 0110
D18.7
111 10010
010011 0111
010011 0001
D19.6
110 10011
110010 0110
110010 0110
D19.7
111 10011
110010 1110
110010 0001
D20.6
110 10100
001011 0110
001011 0110
D20.7
111 10100
001011 0111
001011 0001
D21.6
110 10101
101010 0110
101010 0110
D21.7
111 10101
101010 1110
101010 0001
D22.6
110 10110
011010 0110
011010 0110
D22.7
111 10110
011010 1110
011010 0001
D23.6
110 10111
111010 0110
000101 0110
D23.7
111 10111
111010 0001
000101 1110
D24.6
110 11000
110011 0110
001100 0110
D24.7
111 11000
110011 0001
001100 1110
D25.6
110 11001
100110 0110
100110 0110
D25.7
111 11001
100110 1110
100110 0001
D26.6
110 11010
010110 0110
010110 0110
D26.7
111 11010
010110 1110
010110 0001
D27.6
110 11011
110110 0110
001001 0110
D27.7
111 11011
110110 0001
001001 1110
D28.6
110 11100
001110 0110
001110 0110
D28.7
111 11100
001110 1110
001110 0001
D29.6
110 11101
101110 0110
010001 0110
D29.7
111 11101
101110 0001
010001 1110
D30.6
110 11110
011110 0110
100001 0110
D30.7
111 11110
011110 0001
100001 1110
D31.6
110 11111
101011 0110
010100 0110
D31.7
111 11111
101011 0001
010100 1110
Document #: 38-02008 Rev. *E
Page 54 of 58
CY7C924ADX
Table 12.Valid Special Character Codes and Sequences (TXSC/D* = HIGH or RXSC/D* = HIGH)[28, 29]
S.C. Byte Name
S.C. Code Name
Bits
Current RD−
Current RD+
HGF
EDCBA
abcdei
fghj
abcdei
fghj
K28.0
C0.0[30]
(C00)
000
00000
001111
0100
110000
1011
K28.1
C1.0[31]
(C01)
000
00001
001111
1001
110000
0110
K28.2
C2.0[31]
(C02)
000
00010
001111
0101
110000
1010
K28.3
C3.0[30]
(C03)
000
00011
001111
0011
110000
1100
K28.4
C4.0[31]
(C04)
000
00100
001111
0010
110000
1101
K28.5
C5.0[31, 32]
(C05)
000
00101
001111
1010
110000
0101
K28.6
C6.0[31]
(C06)
000
00110
001111
0110
110000
1001
K28.7
C7.0[31, 33]
(C07)
000
00111
001111
1000
110000
0111
K23.7
C8.0[30]
(C08)
000
01000
111010
1000
000101
0111
K27.7
C9.0[30]
(C09)
000
01001
110110
1000
001001
0111
K29.7
C10.0[30]
(C0A)
000
01010
101110
1000
010001
0111
K30.7
C11.0
(C0B)
000
01011
011110
1000
100001
0111
EOFxx
C2.1[34]
(C22)
001
00010
Exception
C0.7[33, 35]
(CE0)
111
00000
−K28.5
C1.7[36]
(CE1)
111
00001
001111
1010
001111
1010
+K28.5
C2.7[37]
(CE2)
111
00010
110000
0101
110000
0101
Exception
C4.7[38]
End of Frame Sequence
−K28.5,Dn.xxx0
+K28.5,Dn.xxx1
Code Rule Violation and SVS Tx Pattern
100111
1000
011000
0111
Running Disparity Violation Pattern
(CE4)
111
00100
110111
0101
001000
1010
Notes
28. All codes not shown are reserved.
29. Notation for Special Character Code Name is consistent with Fibre Channel and ESCON naming conventions. Special Character Code Name is intended to
describe binary information present on I/O pins. Common usage for the name can either be in the form used for describing Data patterns (i.e., C0.0 through
C31.7), or in hex notation (i.e., Cnn where nn = the specified value between 00h and FFh).
30. These characters have reserved meanings when command processing is enabled. This includes all operating modes where the FIFOs are enabled and the
discard policy is not 0.
31. These characters are used for control of ESCON interfaces. They can be sent as embedded commands or other markers when not operating using ESCON
protocols.
32. The K28.5 character is used for framing operations by the receiver. It is also the pad or fill character transmitted to maintain the serial link when no user data is
available.
33. Care must be taken when using this Special Character code. When a C7.0 or C0.7 is followed by a D11.x or D20.x, an alias K28.5 sync character is created.
These sequences can cause erroneous framing and should be avoided while RFEN is HIGH.
34. C2.1 = Transmit either −K28.5+ or +K28.5− as determined by Current RD and modify the following Transmission Character by setting its least significant bit to
1 or 0. If Current RD at the start of the following character is plus (+) the LSB is set to 0, and if Current RD is minus (−) the LSB becomes 1. This modification
allows construction of X3.230:1994 “EOF” frame delimiters wherein the second data byte is determined by the Current RD.
For example, to send “EOFdt” the controller could issue the sequence C2.1−D21.4− D21.4−D21.4, and the HOTLink Transmitter will send either
K28.5−D21.4−D21.4−D21.4 or K28.5−D21.5− D21.4−D21.4 based on Current RD. Likewise to send “EOFdti” the controller could issue the sequence
C2.1−D10.4−D21.4−D21.4, and the HOTLink Transmitter will send either K28.5−D10.4−D21.4− D21.4 or K28.5−D10.5−D21.4− D21.4 based on Current RD.
The receiver will never output this Special Character, since K28.5 is decoded as C5.0, C1.7, or C2.7, and the subsequent bytes are decoded as data.
35. C0.7 = Transmit a deliberate code rule violation. The code chosen for this function follows the normal Running Disparity rules. Transmission of this Special
Character has the same effect as asserting TXSVS = HIGH. The receiver outputs this Special Character only if the Transmission Character being decoded is
not found in the tables.
36. C1.7 = Transmit Negative K28.5 (−K28.5+) disregarding Current RD. The receiver will only output this Special Character if K28.5 is received with the wrong
running disparity. The receiver will output C1.7 if −K28.5 is received with RD+, otherwise K28.5 is decoded as C5.0 or C2.7.
37. C2.7 = Transmit Positive K28.5 (+K28.5−) disregarding Current RD. The receiver will only output this Special Character if K28.5 is received with the wrong running
disparity. The receiver will output C2.7 if +K28.5 is received with RD−, otherwise K28.5 is decoded as C5.0 or C1.7.
38. C4.7 = Transmit a deliberate code rule violation to indicate a Running Disparity violation. The receiver will only output this Special Character if the Transmission
Character being decoded is found in the tables, but Running Disparity does not match. This may indicate that an error occurred in a prior byte.
Document #: 38-02008 Rev. *E
Page 55 of 58
CY7C924ADX
Printed Circuit Board Layout Suggestions
Power Supply Bypass
0.01 μF MLC X7R
1206 Chip Cap (4 sites)
INA±
OUTA±
OUTB±
INB±
Power Supply Bypass
0.01 μF MLC X7R
CURSETB
Resistor
CURSETA
Resistor
Power Supply Bypass
0.01 μF MLC X7R
1206 Chip Cap (2 sites)
RXSC/D
REFCLK
CY7C9689-AC
CY7C924ADX
Power Supply Bypass
0.01 μF MLC X7R
RESET
Via to VDD plane
Via to VSS plane
Power Supply Bypass
0.01 μF MLC X7R
This is a typical printed circuit board layout showing example
placement of power supply bypass components and other
components mounted on the same side as the CY7C924ADX.
Other layouts, including cases with components mounted on
the reverse side would work as well.
Ordering Information
Ordering Code
Package Name
Package Type
Operating Range
CY7C924ADX-AXC
A100
100-Lead Thin Quad Flat Pack - Lead (Pb) free
Commercial
CY7C924ADX-AI
A100
100-Lead Thin Quad Flat Pack
Industrial
Document #: 38-02008 Rev. *E
Page 56 of 58
CY7C924ADX
Package Diagram
Figure 17. 100-Pin Thin Plastic Quad Flat Pack (TQFP) A100SA
NOTE:
16.00±0.25 SQ
1. JEDEC STD REF MS-026
14.00±0.05 SQ
100
2. BODY LENGTH DIMENSION DOES NOT INCLUDE MOLD PROTRUSION/END FLASH
MOLD PROTRUSION/END FLASH SHALL NOT EXCEED 0.0098 in (0.25 mm) PER SIDE
BODY LENGTH DIMENSIONS ARE MAX PLASTIC BODY SIZE INCLUDING MOLD MISMATCH
76
75
3. DIMENSIONS IN MILLIMETERS
0.22±0.05
1
R 0.08 MIN.
0.20 MAX.
0° MIN.
STAND-OFF
0.05 MIN.
0.15 MAX.
0.25
GAUGE PLANE
R 0.08 MIN.
0.20 MAX.
0.50
TYP.
DETAIL
0°-7°
A
0.60±0.15
0.20 MIN.
25
51
1.00 REF.
26
SEATING PLANE
1.60 MAX.
50
NOTE: PKG. CAN HAVE
OR
12°±1°
(8X)
1.40±0.05
TOP LEFT CORNER CHAMFER
4 CORNERS CHAMFER
0.08
51-85048-*C
0.20 MAX.
SEE DETAIL
A
HOTLink is a registered trademark of Cypress Semiconductor. ESCON and IBM are registered trademarks of International
Business Machines. All product and company names mentioned in this document are the trademarks of their respective holders.
Document #: 38-02008 Rev. *E
Page 57 of 58
CY7C924ADX
Document History Page
Document Title: CY7C924ADX 200 MBaud HOTLink® Transceiver
Document Number: 38-02008
REV.
ECN
NO.
Issue
Date
Orig. of
Change
Description of Change
**
105846 03/26/01
SZV
Change from Spec number: 38-00770 to 38-02008
*A
107878 07/09/01
KET
Changed part number: CY7C924DX to CY7C924ADX
*B
118320 11/13/02
REV
Changed the mentioning of PECL inputs and outputs to PECL-compatible inputs and
outputs, which is more correct.
Changed the font and centered the part number in the device footprint
Fixed the line wrap issue with DLB[1] and DLB[0]
Changed labels on waveforms to make them more consistent with those in the tables
Changed the I/O labels on the D-type flip flop
Changed mentioning of PAREN to TXPAREN to make data sheet more consistent
*C
123796 01/29/03
KKV
Replaced incorrect source copy with correct source copy
*D
201401 01/19/04
TNT
Removed parity
Changed device selection requirements when in FIFO Bypass mode
Added comprehensive table showing SPDSEL/RANGESEL and data rate mapping
Cascade mode read timing description changed, receive timing diagram updated to
reflect operation
Serial Address Register access listed as an option for UTOPIA mode only
Changed FIFO reset condition to show that the count in suspended, not reset, when
TXEN* is asserted
*E
988901 See ECN
UKK
Added Lead-free option package and removed Leaded package in ordering information
Document #: 38-02008 Rev. *E
Page 58 of 58
Similar pages