Fairchild ILC5061AIC23 Power supply reset monitor with 1% precision Datasheet

www.fairchildsemi.com
ILC5061
Power Supply reset Monitor with 1% Precision
Features
Description
•
•
•
•
•
•
All-CMOS design in SOT-23 or SC70 package
±1% precision in Reset Detection
Only 1µA of Iq
2mA of sink current capability
Built-in hysteresis of 5% of detection voltage
Voltage options of 2.6, 2.9, 3.1, 4.4, and 4.6V fit most
supervisory applications
• Open-Drain Reset Output
All-CMOS Monitor circuits in either a 3-lead SOT-23 or
SC70 package offer the best performance in power consumption and accuracy.
Applications
Additionally, a built-in hysteresis of 5% of detect voltage
simplifies system design.
•
•
•
•
The ILC5061 comes in a series of ±1% accurate trip voltages
to fit most microprocessor applications. Even though its output can sink 2mA, the device draws only 1µA in normal
operation.
Microprocessor reset circuits
Memory battery back-up circuitry
Power-on reset circuits
Portable and battery powered electronics
Block Diagram
Pin Package Configurations
VIN
Top View
VOUT
VOUT
1
VOUT
SC-70
3
1
SOT-23
VIN
3
VIN
VREF
VSS
2
VSS
2
VSS
Rev. 2.5 1/2/03
ILC5061
PRODUCT SPECIFICATION
Absolute Maximum Ratings
Parameter
Symbol
Ratings
Units
Input Voltages
VIN
12
V
Output Current
IOUT
50
mA
Output Voltages
VOUT
VSS-0.3~+VIN+03
V
Pd
150
mW
Topr
-30~+80
Continuous Total
Power Dissipation
SOT 23
Operation Ambient temperature
Storage Temperature
Tstg
-40~+125
o
C
oC
Electrical Characteristics TA = 25°C
Parameter
Symbol
Conditions
Min
Type
Max
Units
VDF
VDF X 1.01
V
VDF X 0.05 VDF X 0.08
V
Detect Fail Voltage
VDF
VDF X 0.99
Hysteresis Range
VHYS
VDF X 0.02
VIN = 1.5V
0.9
1.0
1.3
1.6
2.0
VIN = 2.0V
Supply Current
ISS
VIN = 3.0V
VIN = 4.0V
VIN = 5.0V
Operating Voltage
VIN
VDF = 2.1~ 6.0V
1.5
2.6
3.0
3.4
3.8
4.2
µA
10.0
V
N-ch VDS = 0.5V
2.2
7.7
10.1
11.5
13.0
VIN = 1.0V
Output Current
IOUT
VIN = 2.0V
VIN = 3.0V
VIN = 4.0V
mA
VIN = 5.0V
Temperature Characteristics
Delay Time Release
Voltage Output Inversion)
DVDF/(DTopr * VDF) -30oC<Topr<80oC
-200
+100
+200
Ppm/ oC
0.1
ms
TDLY
(VDR to VOUT
inversion)
Note:
1. An additional resistor between the VIN pin and supply voltage may cause deterioration of the characteristics due
to increasing VDR.
2
Rev. 2.5 1/2/03
PRODUCT SPECIFICATION
ILC5061
Functional Description
The following designators 1~6 refer to the timing diagram below.
1. While the input voltage (VIN) is higher than the detect voltage (VDF), the VOUT output pin is at high impedance
state.
2. When the input VIN voltage falls lower than VDF, VOUT drops near to ground voltage
3. If the input voltage further decreases below the minimum operating voltage (VMIN), the VOUT output becomes
unstable. In this condition, if the VOUT pin is pulled up, VOUT indicates the VIN voltage.
4. During an increase of the input voltage from the VSS voltage, VOUT is not stable in the voltage below the VMIN.
Exceeding that level, the output stays at the ground level (VSS) between the minimum operating voltage (VMIN)
and the detect release voltage (VDR).
5. If the input voltage increases more than VDR, then the VOUT output pin is at high impedance state.
6. The difference between VDR and VDF is the hysteresis in the system.
INPUT VOLTAGE (VIN)
DETECT RELEASE VOLTAGE (VDR)
6
DETECT FAIL VOLTAGE (VDF)
MINIMUM OPERATING VOLTAGE (VMIN)
GROUND VOLTAGE (VSS)
OUTPUT VOLTAGE (VOUT)
GROUND VOLTAGE (VSS)
1
Rev. 2.5 1/2/03
2
3
4
5
3
ILC5061
PRODUCT SPECIFICATION
Typical Performance Characteristics (General conditions for all curves)
Output Voltage vs Output Current
Output Voltage vs Output Current
80
ILC5061
800
70
60
OUTPUT CURRENT IOUT (µA)
OUTPUT CURRENT IOUT (mA)
VIN = 4.0V
3.5V
50
3.0V
40
2.5V
30
2.0V
20
10
ILC5061
VIN = 0.8V
600
400
VIN = 0.7V
200
1.5V
0
0
0
1
3
2
4
0
0.6
0.8
OUTPUT VOLTAGE VOUT (V)
Ordering Information
ISS vs Input Voltage*
4.0
0.4
0.2
OUTPUT VOLTAGE VOUT (V)
Output Current vs Input Voltage
ILC5061
20
ILC5061
Topr = -30˚C
Topr = 80˚C
3.0
ISS (µA)
OUTPUT CURRENT IOUT (mA)
VDS = 0.5V
2.0
25˚C
-30˚C
1.0
0
25˚C
15
80˚C
10
5
0
0
1
2
3
4
5
6
7
8
9
10
INPUT VOLTAGE VIN (V)
0
1
2
3
4
5
INPUT VOLTAGE VIN (V)
* A spike of 1/2 to 1µA may appear as VIN crosses VDR or VDF
4
Rev. 2.5 1/2/03
PRODUCT SPECIFICATION
ILC5061
SOT-23 Package
0.021
0.015
0.055
0.047
0.098
0.083
0.120
0.105
0.0059
0.0035
0.040
0.031
0.079
0.071
0-8˚
0.010
0.005
0.004
0.001
0.76
2.29
PKG
CL
0.76
0.95
LAND PATTERN RECOMMENDATION
Rev. 2.5 1/2/03
5
ILC5061
PRODUCT SPECIFICATION
SC70 Package
.087 (2.2)
.071 (1.8)
.053 (1.35)
.045 (1.15)
.087 (2.2)
.079 (2.0)
.009 (.23)
.005 (.13)
.043 (1.1)
.032 (.80)
.004 (.10)
.010 (.25)
.004 (.10)
.016 (.40)
.012 (.30)
.026
(.65)
.018 (.45)
.006 (.15)
.052
(1.3)
0.65
0.5
0.6
1.80
0.65
Land Pattern Recommendation
6
Rev. 2.5 1/2/03
PRODUCT SPECIFICATION
ILC5061
Ordering Information
PART
NUMBER
TOP
MARKING
RESET
THRESHOLD (V)
OUTPUT
TYPE
PACKAGE
PACKING
METHOD
ILC5061AM23X
M3AY
2.3 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM25X
M5AY
2.5 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM26X
M6AY
2.6 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM27X
M7AY
2.7 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM28X
M8AY
2.8 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM29X
M9AY
2.9 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM31X
N1AY
3.1 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM32X
N2AY
3.2 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM34X
N4AY
3.4 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM37X
N7AY
3.7 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM44X
P4AY
4.4 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061AM46X
P6AY
4.6 ± 1 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M23X
M3Y
2.3 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M25X
M5Y
2.5 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M26X
M6Y
2.6 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M27X
M7Y
2.7 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M28X
M8Y
2.8 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M29X
M9Y
2.9 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M31X
N1Y
3.1 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M32X
N2Y
3.2 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M34X
N4Y
3.4 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M37X
N7Y
3.7 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M44X
P4Y
4.4 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
ILC5061M46X
P6Y
4.6 ± 2 %
Open-Drain, active low 3-Pin, SOT23
3K units in T&R
Note 1:Last digit in the "Top Marking" information (represented by "Y" in the above table) represents internal assembly lot
number
Note 2:Orientation of Tape & Reeled devices is Right.
Rev. 2.5 1/2/03
7
ILC5061
PRODUCT SPECIFICATION
Ordering Information
PART
NUMBER
TOP
MARKING
RESET
THRESHOLD (V)
OUTPUT
TYPE
PACKAGE
PACKING
METHOD
ILC5061AIC23X
M3AY
2.3 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC25X
M5AY
2.5 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC26X
M6AY
2.6 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC27X
M7AY
2.7 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC28X
M8AY
2.8 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC29X
M9AY
2.9 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC31X
N1AY
3.1 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC32X
N2AY
3.2 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC34X
N4AY
3.4 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC37X
N7AY
3.7 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC44X
P4AY
4.4 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061AIC46X
P6AY
4.6 ± 1 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC23X
M3Y
2.3 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC25X
M5Y
2.5 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC26X
M6Y
2.6 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC27X
M7Y
2.7 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC28X
M8Y
2.8 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC29X
M9Y
2.9 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC31X
N1Y
3.1 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC32X
N2Y
3.2 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC34X
N4Y
3.4 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC37X
N7Y
3.7 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC44X
P4Y
4.4 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
ILC5061IC46X
P6Y
4.6 ± 2 %
Open-Drain, active low
3-Pin, SC70
3K units in T&R
Note 1: Last digit in the "Top Marking" information (represented by "Y" in the above table) represents internal assembly lot
number
Note 2: Orientation of Tape & Reeled devices is Right.
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO
ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME
ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN;
NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body,
or (b) support or sustain life, and (c) whose failure to
perform when properly used in accordance with
instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of the
user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com
1/2/03 0.0m 001
Similar pages