LPL0411 Series http://www.abco.co.kr Leaded type ▼Shape & Dimensions / Recommended Solder Land Pattern (Dimensions in mm) 6.0max 100 0±2 0 13.0Max 7.0±0.3 18.0±0.5 4.0±0.3 12.7±0.3 5.0±0.3 ▼Electrical Characteristics Ordering Inductance Freq. DC Resistance(Ω) Rated DC Code L (uH) Tol. (%) F (MHz) Rdc (Max.) current(A) LPL0411T-100M 10 ±20 7.96 0.45 0.46 LPL0411T-150K 15 1.30 0.33 LPL0411T-220K 22 1.50 0.27 ±10 2.52 LPL0411T-470K 47 2.20 0.20 LPL0411T-101K 100 3.30 0.15 ▼ Test Equipments . L : Agilent E4980A Precision LCR Meter . Rdc : HIOKI 3540 mΩ HiTESTER . Idc : Agilent 4284A LCR Meter + Agilent 42841A Bias Current Source ▼ Test Condition . Idc(The saturation current) : △L≤ 10% typical at rated current ※ Rated DC current : Idc ▼ Operating Temperature Range -20 ~ +85℃ (Including self-generated heat)