Embedded Power for Business-Critical Continuity Rev. 04.13.06 LPT40 Series 1 of 3 LPT40 Series RoHS 40 Watts Total Power: Input Voltage: # of Outputs: 40 - 55 Watts 85 - 264 VAC 120 - 300VDC Triple Electrical Specifications Special Features • • • • • • • • • • • • Universal input 3" x 5" footprint Less than 1U high Remote sense on main output Terminal Block option (-T) Built-in EMI filter Low output ripple Adjustable main output Overvoltage protection Overload protection 110 KHz switching frequency LPX40 enclosure kit available Input Input range Frequency Inrush current Input current Efficiency EMI Safety ground leakage current 85-264 VAC 120-300 VDC 47-440 Hz <18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C 1A max. (RMS) @ 115VAC 70% typical at full load (60% for LPT41) FCC Class B conducted; CISPR 22 Class B conducted EN55022 Class B conducted; VDE 0878 PT3 Class B conducted <0.5 mA @ 50/60 Hz, 264 VAC input Output Maximum Power Safety UL UL1950 E132002 CSA CSA 22.2-234 Level 3 LR53982C NEMKO EN 60950/EMKO-TUE P95100411 (74-sec) 203 CB Certificate and report 1118, 1122, 1123, 1124 CE Mark (LVD) Cross regulation Adjustment range Hold-up time Overload protection Overvoltage protection Remote sense 40W for convection (LPT41, 25W); 55W with 30CFW forced air (LPT41, 41W) ±2% on output 1; ±5% on outputs 2, 3 -5, +10% minimum 20ms @ 40W load, 115 VAC nominal line Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating 5.7 to 6.7 VDC on the main output LPT41: 3.6 to 4.6VDC Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected. Embedded Power for Business-Critical Continuity Rev. 04.13.06 LPT40 Series 2 of 3 Environmental Specifications Operating temperature: 0° to 50°C ambient derate each output at 2.5% per degree from 50° to 70°C, -20°C start up. Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3 Electromagnetic susceptibility: Humidity: Operating; non-condensing 5% to 95% Vibration: Storage temperature: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5 Hz to 500 Hz, operational -40° to 85°C Temperature coefficient: ±.04% per °C MTBF demonstrated: >550,000 hours at full load and 25°C ambient conditions Ordering Information LPT41(-T) +3.3V +5V +12V 0.5A 0A 0A Maximum Load with Convnection cooling 4A 1.5A 0.5A LPT42(-T) +5V +12V -12V +5V +12V -12V +5V +12V -5V +5V +15V -15V +5V +24V +12V +5V +24V -12V 0.4A 0.2A 0A 0.5A 0A 0A 0.4A 0.2A 0A 0.4A 0.2A 0A 0.4A 0.1A 0A 0.4A 0.2A 0A 4A 2A 0.5A 6A 0.5A 0.5A 4A 2A 0.5A 4A 2A 0.5A 4A 1.0A 0.5A 4A 1.0A 0.5A Model Number LPT43(-T) LPT44(-T) LPT45(-T) LPT46(-T) LPT47(-T) Output Voltage Minimum Load Maximum Load with 30CFM Forced Air 7A 2.0A 0.7A 5A 2.5A 0.7A 8A 0.7A 0.7A 5A 2.5A 0.7A 5A 2.5A 0.7A 5A 1.5A 0.7A 5A 1.5A 0.7A Peak Load1 Regulation2 Ripple P/P (PARD)3 7A 2.5A 0.7A ±2% ±2% ±5% 50mV 50mV 120mV 7A 4A 1A 9A 1A 1A 7A 4A 1A 7A 3A 1A 6A 2A 1A 6A 2A 1A ±2% ±5% ±5% ±2% ±5% ±5% ±2% ±5% ±5% ±2% ±5% ±5% ±2% ±7% ±5% ±2% ±7% ±5% 50mV 120mV 120mV 50mV 120mV 120mV 50mV 120mV 50mV 50mV 150mV 150mV 50mV 240mV 120mV 50mV 240mV 120mV 1. Peak current lasting <30 seconds with a maximum 10% duty cycle. 2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges. 4. Minimum Loads are required. 5. (-T) indicates Terminal Block option for input and output (instead of Molex type) Power Derating Curve 55W 30 CFM Forced Air Cooling 40W 30W Output Power (Watts) 20W Natural Convection Cooling 27.5W 20W 10W 0W 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C TA – Ambient Temperature – °C Embedded Power for Business-Critical Continuity Astec Power Mechanical Drawing 0.22" (5.6) 4.55" (115.6) 5.00" (127) M1 GND M2 SK201 3.00" (76.2) 1 2 3 4 5 6 2.55" (64.8) SK 1 3 N 1 L _ + Remote Sense Connector Voltage Adj. Pot SK 2 0.15" (4) DIA (4 places) Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom Telephone: +44 (0) 1384 842 211 Facsimile: +44 (0) 1384 843 355 Units 2111-2116, Level 21 Tower 1, Metroplaza 223, Hing Fong Road Kwai Fong, New Territories Hong Kong Telephone: +852 2437 9662 Facsimile: +852 2402 4426 www.astecpower.com [email protected] While every precaution has been taken to ensure accuracy and completeness in this literature, Astec Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. 0.12" (3) Pin Assignments Printed in U S A Connector LPT41 LPT42 LPT43 LPT44 LPT45 LPT46 LPT47 SK1-1 SK1-3 Line Neutral Line Neutral Line Neutral Line Neutral Line Neutral Line Neutral Line Neutral SK2-1 SK2- 2 SK2- 3 SK2-4 SK2-5 SK2-6 SK201-1 SK201-2 5V 3.3V 3.3V Common Common 12V +Sense -Sense +12V +5V +5V Common Common -12V +Sense -Sense +12V +5V +5V Common Common -12V +Sense -Sense +12V +5V +5V Common Common -5V +Sense -Sense +15V +5V +5V Common Common -15V +Sense -Sense +24V +5V +5V Common Common +12V +Sense -Sense +24V +5V +5V Common Common -12V +Sense -Sense Mating Connectors DC Outputs: 5810 Van Allen Way Carlsbad, CA 92008 USA Telephone: +1 760 930 4600 Facsimile: +1 760 930 0698 Technical Support: +1 888 41 ASTEC or +1 407 241 2752 For global contact, visit: 1.14" (29) AC Input: Rev. 04.13.06 LPT40 Series 3 of 3 Molex 09-50-8031 (USA) Not required for (-T) option 09-91-0300 (UK) PINS: 08-52-0113 Molex 09-50-8061 (USA) Not required for (-T) option 09-91-0600 (UK) PINS: 08-52-0113 Remote Sense: Molex 22-01-2025 PINS: 08-52-0123 Astec Connector Kit #70-841-006, includes all of the above 1. 2. Specifications subject to change without notice. All dimensions in inches (mm), tolerance is ±0.02" (±0.5mm) 3. 4. 5. Mounting holes M1 and M2 should be grounded for EMI purposes. Mounting hole M1 is safety ground connection. Specifications are for convection rating at factory settings at 115 VAC input, 25°C unless otherwise stated. 6. 7. Warranty: 1 year Weight: 0.5lbs/0.23kg Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2006 Emerson Electric Co.