Keysight N8843A I3csm protocol trigger and decode Datasheet

Keysight N8843A
I3CSM Protocol Trigger and Decode
for Infiniium Oscilloscope
Data Sheet
02 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
This application is available in the following license variations
–– Fixed to an oscilloscope
–– Floating license
–– Server-based license
–– Transportable license
Easily debug and test designs that include MIPI I3C interface using your
Infiniium Oscilloscopes
Improved Inter Integrated Circuit (I3C) is one of MIPI® (Mobile industry Processor Interface)
standard aimed for next generation Sensor interface. This new interface improved upon the
feature of I2C (inter Integrated Circuit) and provide backward compatibility with Legacy I2C
devices. I3C is consist of 2 two bidirectional wires called SDA, SCL and optimized for multiple
slave devices which controlled by one I3C master device at a time. I3C supports Higher speed
than Legacy I2C which is 12.5 MHz and supporting several new high data rate (HDR) mode
called as HDR-DDR (Double Data Rate), HDR-TSL (Ternary Symbol Legacy) and HDR-TSL
(Ternary Symbol for Pure bus).
Extend your oscilloscope capability with I3C trigger and decode application. This application
makes it easy to debug and test design that include I3C interface using your Infiniium
oscilloscopes.
–– Set your oscilloscope up to show I3C protocol decode in less than 30 seconds
–– Get access to a rich set of integrated protocol-level triggers
–– Save time and eliminate errors by viewing packets at protocol level
–– Use time-correlated views to quickly troubleshoot serial protocol problems
Easy to find
30 second I3C setup
Turn decode on/off via the “Serial
Decode” button on the front of the
instrument or in the “Setup” menu. View
decode embedded on the waveform
display or in the protocol viewer listing
window.
Configure your oscilloscope to display I3C
protocol decode in under 30 seconds. Use
“Auto Setup” to automatically configure
sample rate, memory depth and threshold
and trigger levels.
Support for saved waveform
and digital channels
Acquire serial clock and data using
any combination of analog and digital
channel. Also supports captured
waveform using memory channel so
capture signal first and analyze after
then.
03 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
I3C Protocol Triggering and Searching
Get access to a rich set of integrated protocol level triggers. This decoder software includes
a suite of configurable protocol level trigger conditions for I3C interface bus. When serial
triggering is selected, decoder software enables special real time hardware based triggering
function inside of S-Series oscilloscope.
Hardware-based serial triggering ensures that oscilloscope never misses a trigger event
when it armed. This function is activated on S-Series oscilloscope, and acquire signal using
either oscilloscope’s analog channel input or digital channel input if it has MSO (Mixed Signal
Oscilloscope) option.
I3C trigger setup
Post-acquisition searching
Trigger support several types of data pattern, supported by I3C
specification.
Search specific packet from acquired protocol listing using a
menu that is identical to the trigger menu.
04 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
I3C Protocol Triggering and Searching (Continued)
In depth trigger/search
Using up to 3 field values of specific packet type, possible to trigger on specific pattern that
want to see. This field include Payload trigger/search.
05 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
I3C Protocol Decode
Keysight N8843A I3C protocol decoder software identifying legacy I2C message based on
Legacy I2C address registration, so that engineer can distinguish the communication between
I3C and Legacy I2C protocol data easily and can find ACK or NACK error based on address.
Protocol decode with time correlation between waveform and listing
I3C protocol list window is correlated between the waveform and the selected packet on the
list. The selected packet, highlighted blue row is time-correlated with the blue line in the
waveform display so that engineer can see signal shape on specific packet data more efficiently.
06 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
I3C Protocol Decode (Continued)
Legacy I2C address configuration
Isolate Legacy I2C device on the bus will provide easy distinguish Legacy I2C device and
Standard I3C device and also provide right SDR Parity calculation on trigger and decode.
Resize-able window size
Flexible window size on protocol decoder window provide more usability to see specific part of
interest. Especially full screen listing window show more protocol dependent data on acquired
waveform so that help the engineer find out communication error on protocol side.
07 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
Performance Characteristics
Options
I3C protocol supported
Description
Legacy I2C standard mode, fast mode, fast mode+ (plus)
I3C SDR (standard data rate)
I3C HDR-DDR (double data rate)
Analog channels 1, 2, 3, or 4
Digital channels D0-D15 (on MSO models)
Waveform memories
Up to 12.5 MHz
Legacy I2C configuration
Start/Restart
Stop
Legacy I2C message
Typical I3C SDR message
I3C SDR broadcast message
I3C SDR direct message
Errors
I3C source (SDA, SCL)
Support clock rate
Configuration option
Triggering/Search
Standard Configuration
Options
9000A and S-Series oscilloscope
90000A series oscilloscope
V-Series and Z-Series oscilloscope
Description
Oscilloscope (500 MHz or above) + 2x passive probe
Oscilloscope + 2 x High impedance probe kits (E2697A)
Oscilloscope + 2 x High impedance probe kits (N5449A)
Ordering Information
This application is compatible with Infiniium Oscilloscope models below.
Application software
I3C protocol trigger and
decode software 1
9000 Series
Floating
Fixed
Transportable
Server-based
S-Series
90000 Series
N8843A-1FP
N8843A-2FP
N5435A-107
1. Require Infiniium 5.70 or above.
2. Hardware based serial triggering is supported by S-Series only.
Related Literature
Publication title
Infiniium S-Series High-Definition Oscilloscopes - Data Sheet
Infiniium 9000 Series Oscilloscopes - Data Sheet
Infiniium V-Series Oscilloscopes - Data Sheet
Infiniium 90000 Series Oscilloscopes - Data Sheet
Infiniium Z-Series Oscilloscopes - Data Sheet
Publication number
5991-3904EN
5990-3746EN
5992-0425EN
5989-7819EN
5991-3868EN
MIPI® and I3C SM are trademarks, servicemarks, registered trademarks, and/or registered servicemarks owned
by MIPI Alliance.
V-Series
Z-Series
08 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. The business that became Keysight was a founding
member of the AXIe consortium. ATCA®, AdvancedTCA®, and the ATCA logo
are registered US trademarks of the PCI Industrial Computer Manufacturers
Group.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the Web
inside your test systems. The business that became Keysight was a founding
member of the LXI consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
Download your next insight
Keysight software is downloadable
expertise. From first simulation through
first customer shipment, we deliver the
tools your team needs to accelerate from
data to information to actionable insight.
–– Electronic design automation (EDA)
software
–– Application software
–– Programming environments
–– Productivity software
Learn more at
www.keysight.com/find/software
Start with a 30-day free trial.
www.keysight.com/find/free_trials
09 | Keysight | N8843A I3CSM Protocol Trigger and Decode for Infiniium Oscilloscope - Data Sheet
Evolving
Our unique combination of hardware, software, support, and people can help
you reach your next breakthrough. We are unlocking the future of technology.
From Hewlett-Packard to Agilent to Keysight
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
Keysight Services
www.keysight.com/find/service
Our deep offering in design, test, and measurement services deploys an
industry-leading array of people, processes, and tools. The result? We help
you implement new technologies and engineer improved processes that
lower costs.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysight’s committed to superior product quality and lower total cost
of ownership. Keysight is the only test and measurement company with
three-year warranty standard on all instruments, worldwide. And, we provide
a one-year warranty on many accessories, calibration devices, systems and
custom products.
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate
measurements.
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
MIPI® service marks and logo marks are owned by MIPI Alliance, Inc. and any
use of such marks by Keysight Technologies is under license. Other service
marks and trade names are those of their respective owners.
www.keysight.com/find/N8843A
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 11 2626
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-09-23-16)
DEKRA Certified
ISO9001 Quality Management System
www.keysight.com/go/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2015
Quality Management System
This information is subject to change without notice.
© Keysight Technologies, 2016
Published in USA, October 4, 2016
5992-1850EN