Rosenberger L99-816-30E Cable assembly Datasheet

Technical Data Sheet
Cable assembly
L99-816-XXE
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Mini Coax Plug/Jack - SMA Plug - RTK 047 Cable
All dimensions are in mm; tolerances: ± 3mm for A ≤ 300 mm; ± 1% for A > 300 mm
Available variants
Type
L99-816-XXE
max. Insertion loss at 20 GHz
≤ 0.0050 dB/mm * A mm + 0.60 dB
Marking
ROSENBERGER YYYY-WW
L99-816-XXE
FAC-RRRRRRR
ssss
XX – length in cm
E=4 Channel
A=XX*10
WW – week
YYYY – year
ssss – serial no.
Note:
Weight (g) / pce
0,022 g/mm * A mm + 21,4 g
FAC – Factory Code
RRRRRRR – lot nr.
max. Insertion Loss:
First constant = Cable attenuation in dB /mm; Second Constant = Connector left and Connector right +needed Adaptor
Weight:
First constant = Cable- and Armour- weight per mm; Second Constant = Connector left and Connector right weight per pce
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
1/2
Technical Data Sheet
Cable assembly
L99-816-XXE
Mini Coax Plug/Jack - SMA Plug - RTK 047 Cable
Assembly parts
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Connector left
Connector left
Connector right
Cable
Housing
Mini Coax plug
Mini Coax jack
SMA plug
RTK 047
23Z121-007
23S103-270L3
23K103-270L3
32S102-270L5
(4 channel) Luranyl KR 2402 gray
Electrical data
50 Ω
DC to 20 GHz
≥ 16 dB, DC to 20 GHz
see table available variants
Impedance
Frequency
1
Return loss
1
Insertion loss
Individual testing:
The S-Parameters (S11; S22; S21; S12) will be tested
1
Return Loss and Insertion Loss includes the measurement adaptor
Mechanical data
Minimum bend radius:
Single
Multiple
5.1 mm
10.2 mm
Environmental data
Temperature range
RoHS
-40°C to +115°C
compliant
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve our
products, we reserve the right to make changes judged to be necessary.
Draft
Date
Martin Moder
27.07.15
Approved
Herbert Babinger
Date
Rev.
Engineering change number
Name
Date
11.08.15
d00
15-1020
Kathrina Mitterer
11.08.15
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260
D-84526 Tittmoning
Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : [email protected]
Page
2/2