Flex GF506D Pre-action / Deluge Control Panel Description General The Flex GF506D is a six-zone FACP used for single and dual hazard deluge and pre-action applications. The Flex GF506D provides reliable fire detection. It also offers signaling and protection for commercial, industrial, and institutional buildings that require water-based releasing. The Flex GF506D is compatible with System Sensor’s i3 detectors. The i3 detectors are conventional smoke detectors that transmit a maintenance trouble signal to the FACP that indicates the need for cleaning. It also transmits a supervisory ‘freeze’ signal when the ambient temperature falls below the detector rating of approximately 45°F (7.22°C). In addition, the Flex GF506D control panel is compatible with the following conventional input devices: • two-wire and four-wire smoke detectors • pull stations • waterflow devices and tamper switches • other normally-open contact devices For a complete listing of compatible devices, refer to the Gamewell-FCI Device Compatibility Document, P/N: 52195. There are four outputs that are programmable as NACs (Notification Appliance Circuits) or releasing circuits. Three programmable Form-C relays (factory programmed for Alarm, Trouble, and Supervisory), and the 24 VDC special application resettable and non-resettable power outputs are included on the main circuit board. The Flex GF506D supervises all wiring, AC voltage, battery charger, and battery level. The activation of a compatible smoke detector or any normally open fire alarm initiating device will do the following: • turn on audible and visual signaling devices • light an indicator • display alarm information on the panel’s LCD • sound the piezo sounder at the FACP • activate the FACP alarm relay • operate an optional module used to notify a remote station or initiate an auxiliary control function Flex GF506D Features • • • • • • • Listed to UL Standard 864, 9th Edition. IBC Seismic Certified. Designed for sprinkler standards NFPA 13, 15 and 16. Dual hazard operation. Adjustable waterflow discharge timer and two soak timers. Cross-zone (double-interlock) capability. Six programmable Style B (Class B) IDCs (Initiating Device Circuit) with optional Class A wiring. • System Sensor i3 series detectors compatible. • Four programmable Style Y (Class B) output circuits (special application power) with Class A Style Z option. • Strobe Synchronization: -Gentex - Cooper-Wheelock - System Sensor - Faraday - Amseco • • • • • Three programmable Form-C relays. 7.0 amps total 24 VDC output current. Resettable and non-resettable output power. Built-in Programmer. ANN-BUS for connection to optional (up to 8 total of any of the following): -GFANN-80 Remote LCD Annunciator -GFANN-RLY Relay Module -GFANN-LED Annunciator Module • 80-character LCD display (backlit). • Real-time clock/calendar w/daylight savings time control. SIGNALING FM i 3™ is a trademark of Honeywell International Inc. ® UL is a registered trademark of Underwriter’s Laboratories Inc. Reference Certificate of Compliance 7165-1703:0171 VMA-45894-02C (Revision 1) APPROVED S624 GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use. www.gamewell-fci.com 9021-60466 Rev. D page 1 of 4 ©2013 by Honeywell International Inc. All rights reserved. Features (Continued) Features (Continued) • • • • • AC Power – TB1 The AC Power -TB1 for each panel is listed below: • GF506D: 120 VAC, 50/60 Hz, 2.3 amps • Wire size: minimum #14 AWG (2.0 mm2) with 600V insulation. • Supervised, non power-limited • • • • • • • • • History Log with 256 event storage. Piezo sounder for alarm, trouble and supervisory. 24 volt DC operation. Low AC voltage sense. Outputs Programmable for the following: - Releasing circuits or NACs NACs programmable for the following: - Silence Inhibit - Auto-Silence - Strobe Synchronization - Selective Silence (horn-strobe mute) - Temporal or Steady Signal - Silenceable or Non-silenceable - Release Stage Sounder Disable/Enable control per input zone and output zone. Extensive transient protection. Automatic battery charger with charger supervision. Optional Dress Panel DP-51050 (red). Optional Trim Ring TR-CE (red) for semi-flush mounting the cabinet. Optional CAC-5X Class A Converter Module for Outputs and IDCs. Optional 4XTMF Municipal Box Transmitter Module. Optional Digital Alarm Communicators (411, 411UD, 411UDAC). Programming and Software The programming software offers the following features: • Custom English labels (per point) may be manually entered or selected from an internal library file. • Three programmable Form-C relay outputs. • Pre-programmed and custom application templates. • Continuous fire protection during online programming at the front panel. • Program Check automatically catches common errors not linked to any zone or input point. User Interface The user interface features are listed below: • Integral 80-character LCD display with backlighting. • Real-time clock/calendar with automatic daylight savings adjustments. • ANN-Bus for connection to remote annunciators. • Audible or silent walk test capabilities. • Piezo sounder for alarm, trouble, and supervisory. Controls and Indicators The panel provides the following LED Indicators: • Fire Alarm (red) • AC Power (green) • Supervisory (yellow) • Alarm Silenced (yellow) • Trouble (yellow) • Discharge (red) Control Buttons • Acknowledge • Alarm Silence • System Reset (lamp test) • Drill Battery (sealed lead acid only) – J12: The Battery (for sealed lead acid only) - J12 specifications are listed below. • Maximum Charging Circuit - Normal Flat Charge: - 27.6 VDC @ 1.4 amp. Supervised, non power-limited. • Maximum Charger Capacity: - 26 Amp Hour battery (two 18 Amp Hour batteries can be housed in the FACP cabinet. Larger batteries require separate battery box such as the BB-26 or BB-55). • Minimum Battery Size: 7 Amp Hour Initiating Device Circuits - TB4 and TB6 The Initiating Device Circuits for TB4 and TB6 specifications are listed below. • Alarm Zones 1 - 5 on TB4 • Alarm Zone 6 on TB6 • Supervised and power-limited circuitry • Style B (Class B) wiring with Style D (Class A) option • Normal Operating Nominal 20 VDC Voltage: • Alarm Current: 15 mA minimum • Short Circuit Current: 40 mA max • Maximum Loop 100 Ohms Resistance: • End-of-Line Resistor: 4.7KOhms, 1/2 watt (PN 71252) • Standby Current: 4 mA For a list of compatible devices, refer to the Gamewell-FCI Device Compatibility Document, P/N: 52195. Notification Appliance and Releasing Circuit(s) TB5 and TB7 The notification appliance and releasing circuits for TB5 and TB7 specifications are listed below. • Four Output Circuits. • Style Y (Class B) or Style Z (Class A) with optional converter module • Strobe synchronization • Special Application power • Supervised and power-limited circuitry • Normal Operating Voltage: Nominal 24 VDC • Maximum Signaling 7.0 amps (3.0 amps Current: maximum per NAC) • End-of-Line Resistor: 4.7KOhms, 1/2 watt (PN71252) • Max. Wiring Voltage 2 VDC Drop: For a list of compatible devices, refer to the Gamewell-FCI Device Compatibility Document, P/N: 52195. GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60466 Rev. D page 2 of 4 www.gamewell-fci.com Features (Continued) Product Line Information Form-C Relays - Programmable - TB8 Product Description The Form-C Relays for TB8 specifications are listed below. • Relay 1 (factory default programmed as Alarm Relay) • Relay 2 (factory default programmed as fail-safe Trouble Relay) • Relay 3 (factory default programmed as Supervisory Relay). • Relay Contact Ratings: - 2 amps @ 30 VDC (resistive) - 2 amps @ 30 VAC (resistive) GF506D Auxiliary Trouble Input – J6 4XTMF Six-zone, 24 volt Pre-action Deluge Control Panel (includes backbox, power supply, technical manual, and a frame & post operating instruction sheet) for single and dual hazard deluge and preaction applications. Class A Converter Module can be used to convert the Style B (Class B) Initiating Device Circuits to Style D (Class A) and Style Y (Class B) Output Circuits to Style Z (Class A). Transmitter Module provides a supervised output for the local energy municipal box transmitter and the alarm and trouble reverse polarity. It includes a disable switch and disable trouble LED. LCD Annunciator is a remote LCD annunciator that mimics the information displayed on the FACP LCD display. The recommended wire type is unshielded. Annunciator Module provides three LEDs for each zone: Alarm, Trouble and Supervisory. Ships with enclosure (red and black enclosures available; refer to P/N: DF-60241). Relay Module, which can be mounted inside or outside the cabinet, provides 10 programmable Form-C relays. Dress panel (red) is available as an option. The dress panel restricts access to the system wiring while allowing access to the membrane switch panel. Trim-ring (red) is available as an option. The trim-ring allows semi-flushing mounting of the cabinet. Battery box, holds up to two (2) 18 Amp Hour batteries. Battery box, houses two (2) 55 Amp Hour batteries, red. Refer to P/N: DF-52397. UL-Listed compatible event printer. Dotmatrix, tractor-fed paper, 120 VAC. Programming cable. Use this cable to update the FACPs Flash firmware. (Also it requires an RS485 to RS232 converter). The Auxiliary Trouble Input is an open collector circuit which can be used to monitor external devices for trouble conditions. It can be connected to the trouble bus of a peripheral, such as a power supply, which is compatible with open collector circuits. CAC-5X GFANN-80 Special Application Resettable Power - TB9 The Special Application Resettable Power - TB9 specifications are listed below. • Operating Voltage: Nominal 24 VDC • Maximum Available 500 mA - appropriate for Current: powering 4-wire smoke detectors (see note 1). • Power-limited Circuitry For a list of compatible devices, refer to the Gamewell-FCI Device Compatibility Document, P/N: 52195. GFANN-LED GFANN-RLY DP-51050 NOTE 1: Total current for resettable power, non-resettable power and Output Circuits must not exceed 7.0 amps. TR-CE Special Application Resettable or Non-resettable Power - TB9 BB-17F The Special Application Resettable or Non-resettable Power - TB9 specifications are listed below. • Operating Voltage: Nominal 24 VDC • Maximum Available 500 mA (see Note 1) Current: • Power-limited circuitry • Jumper selectable by JP31 for resettable or non-resettable power. For a list of compatible devices, refer to the Gamewell-FCI Device Compatibility Document, P/N: 52195. PRN-6 PRT/PK-Cable GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 www.gamewell-fci.com 9021-60466 Rev. D page 3 of 4 System Specifications System Specifications (Continued) System Capacity: Temperature and Humidity Ranges Annunciators ............8 Electrical Specifications Flex GF506D (FLPS-7 Power Supply): 120 VAC, 50/60 Hz, 2.3 amps Wire size: minimum 14 AWG (2.0 mm²) with 600 V insulation, supervised, non power-limited This system meets NFPA requirements for operation at 0° –49°C/32° – 120°F and at a relative humidity 93% ± 2% RH (non-condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15° – 27°C/60° – 80°F. Cabinet Specifications Door Dimensions: Backbox: Dimensions: Trim Ring (TR- CE): Dimensions: NFPA Standards 19.26" H x 16.82" W x 0.72" (48.92 H x 42.73 W x 1.82 D cm) 19.00" H x 16.65" W x 5.25" D (48.26 H x 42.29 W x 13.34 D cm) 22.00" high x 19.65" wide (55.88 H x 49.91 W cm) Shipping Specifications Dimensions: - Height 20.00" (50.80cm) - Width 22.50" (57.15cm) - Depth 8.50" (21.59cm) The GF506D complies with the following NFPA 72 Fire Alarm Systems requirements: - NFPA 13 Installation of Sprinkler Systems - NFPA 15 Water Spray Fixed Systems - NFPA 16 Deluge Foam-Water Sprinkler and FoamWater Spray Systems - NFPA 72 National Fire Alarm Code for Local Fire Alarm Systems and Remote Station Fire Alarm Systems (requires an optional Remote Station Output Module) GAMEWELL-FCI 12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118 9021-60466 Rev. D page 4 of 4 www.gamewell-fci.com