LinkCom DBFE0060U172 0-10v dimmable Datasheet

0-10V Dimmable
Constant Current Mode
60-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
FEATURES:
● AC Input 90~305 Vac Nominal
● Built-in Active Power Factor Correction
● Protection: SCP / OVP / OTP
● High Operating Ambient Temp.: -20℃~+60℃
● THD: <20% @ 277VAC Full Load
● Surge Protection: L-N 1 kV, L/N-FG 2 kV
● Safety: UL
● EMI: Meets CE / Meets FCC
● Comply with Indoor/Outdoor Waterproof (IP 67)
● Warranty: 3 years (refer to LinkCom warranty policy)
● 0-10V dimming
● RoHS Compliant
PRODUCT SPECIFICATION
DC OUTPUT
POWER(W)
DC OUTPUT
VOLTAGE(V)
OUTPUT
CURRENT(A)
OUTPUT
CURRENT
TOLERANCE
EFFICIENCY
O/P NOISE
(pk-pk,V)
DBFE0060U132
62.4
42-48V
1.3
±5%
86%
4.6V
DBFE0060U142
58.8
33-42V
1.4
±5%
86%
4.2V
DBFE0060U152
60.0
30-40V
1.5
±5%
86%
4V
DBFE0060U172
61.2
30-36V
1.7
±5%
86%
3.6V
DBFE0060U212
63.0
24-30V
2.1
±5%
86%
3.6V
DBFE0060U252
60.0
19-24V
2.5
±5%
86%
2.7V
DBFE0050U432
51.6
9-12V
4.3
±5%
82%
2V
MODEL
ELECTRICAL SPECIFICATION
INPUT VOLTAGE RANGE
90-305 Vac, 127-431 Vdc, Normal: 100-277 Vac
INPUT FREQUENCY
Range: 47-63Hz, Normal: 50-60Hz
ACTIVE POWER FACTOR
> 0.95 @ 110 Vac; > 0.9 @ 230 Vac
THD
< 20% at Full Load 100-277 Vac
TURN ON DELAY TIME
3000 ms at Full Load 115 Vac / 230 Vac
AC CURRENT
0.8 A / 110 Vac; 0.4 A / 230 Vac
INRUSH CURRENT (typ)
Cold Start 50 A @ 230 Vac
LEAKAGE CURRENT
< 0.75 mA at 277 Vac
SHORT CIRCUIT PROTECTION
OVER VOLTAGE PROTECTION
automatically after the fault condition is removed
OVER TEMP. PROTECTION
-20℃ ~ +60 ℃ @ Full Load 110-277 Vac
OPERATING TEMP.
-40 ℃ ~ +80 ℃
STORAGE TEMP.
RELATIVE HUMIDITY
10% to +90%, non-cond.
SAFETY
UL 8750
EMI
Meets FCC Part15 / Meets EN 55015
WITHSTAND VOLTAGE
I/P-O/P:4242 Vdc, I/P-FG:2500 Vdc,I/P-CASE : 2500 Vdc
ISOLATION RESISTANCE
I/P-O/P, I/P-FG,O/P-FG : >10M Ω / 500 Vdc / 25℃ / 70% RH
DIMENSION (L*W*H)
158 * 58 * 39.4 mm【6.22 * 2.28 * 1.55 inch】
(1) All parameters specified at 230 Vac input unless otherwise noted.
(2) All specifications Typical at 25℃, unless otherwise noted, at normal line and load.
(3) Ripple and Noise measured directly at pins/terminals at nom. load, pk-pk at 20MHz bandwidth.
(4) Specified for free-air convection cooling.
(5) Minimum load is NOT required for proper operation .
(6) 100% Production Tested.
*REFERENCE: www.linkcom.com.tw
*Please contact [email protected], [email protected] for more information
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
60-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
DIMENSIONS
Tc Max.
DBFE0060U252 as Tc Max. Reference
*REFERENCE: www.linkcom.com.tw
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
60-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
DIMMING OPERATION (Typical)
Parameters
Absolute maximum voltageon on the 0-10(+) Purple Wire
Source current on the 0-10V(+) Purple Wire
Minimum
Typical
1V
─
Maximum
10V
0mA
─
1mA
0-10V Analog Dimming Typical Circuit
(Leviton) IP710 Dimmer
Purple(+)
PDBFE0060XXXX-00G
V
Gray(-)
(Lutron) NTSTV-DV Dimmer
Red(+)
Black(-)
Dimming Performance
110%
100%
90%
Output Current (%)
80%
70%
60%
50%
40%
30%
20%
10%
0%
0
1
2
3
4
5
6
7
8
9
10
Dimming input(Vdc)
Notes:
1. 0-10V Dimmable must be connect to extra two wires +Purple/-Gray on the output side.
2. Recommended dimmers are Leviton IP710,Lutron NTSTV-DV or equivalent.
3. If output side wires +Purple/-Gray are open, the output current Io will be 100%.
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
60-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
Output Current vs.
Load (DBFE-060U132-00)
Output Current vs. Load
Output Current (A)
1.320
1.310
1.300
Vin=100
Vin=120
1.290
Vin=200
Vin=230
Vin=277
1.280
84%
86%
88%
90%
92%
94%
96%
98%
100%
102%
Load (%)
Power Factor vs. Load (DBFE-060U132-00)
PF vs. Load
1.00
Power Factor
0.95
0.90
Vin=100
Vin=120
0.85
Vin=200
Vin=230
Vin=277
0.80
86%
88%
90%
92%
94%
96%
98%
100%
102%
Load (%)
Efficiency vs. Load (DBFE-060U132-00)
Efficiency vs. Load
90.0%
Efficiency (%)
88.0%
86.0%
Vin=100
84.0%
Vin=120
Vin=200
82.0%
Vin=230
Vin=277
80.0%
86%
88%
90%
92%
94%
96%
98%
100%
102%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
0-10V Dimmable
Constant Current Mode
60-DBFE Series
www.linkcom.com.tw For more information, please contact with: [email protected]
THD vs. Load (DBFE-060U132-00)
THD vs. Load
20%
THD (%)
15%
10%
Vin=100
Vin=120
5%
Vin=200
Vin=230
Vin=277
0%
86%
88%
90%
92%
94%
96%
98%
100%
102%
Load (%)
Linkcom Manufacturing Co., Ltd.
5F., No. 127, Ln. 235, Baoqiao Rd., Xindian Dist., New Taipei City 231-45, Taiwan ▪ T: +886-2-8919-1380 ▪ F: +886-2-8919-1370 ▪ www.linkcom.com.tw
Similar pages