1 3 TO -24 7 2 1 - Cathode 1 2 - Anode 1 Cathode 2 3 - Anode 2 APT15D100BHB 1 2 1000V 2x15A 3 ULTRAFAST SOFT RECOVERY RECTIFIER DIODES PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS • Output Rectifiers for Switchmode • Ultrafast Recovery Times • Low Losses • Soft Recovery Characteristics • Low Noise Switching • Popular TO-247 Package • Cooler Operation • Low Forward Voltage • Higher Reliability Systems • High Blocking Voltage • Increased System Power Power Supply Density • Low Leakage Current MAXIMUM RATINGS Symbol VR All Ratings Are Per Leg: TC = 25°C unless otherwise specified. Characteristic / Test Conditions APT15D100BHB UNIT 1000 Volts Maximum D.C. Reverse Voltage VRRM Maximum Peak Repetitive Reverse Voltage VRWM Maximum Working Peak Reverse Voltage IF(AV) Maximum Average Forward Current (TC = 90°C, Duty Cycle = 0.5) 15 RMS Forward Current 25 Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms) 80 IF(RMS) IFSM TJ,TSTG TL Amps -55 to 150 Operating and StorageTemperature Range °C 300 Lead Temperature: 0.063" from Case for 10 Sec. STATIC ELECTRICAL CHARACTERISTICS Characteristic / Test Conditions MIN TYP IRM 2.4 IF = 30A Maximum Forward Voltage Maximum Reverse Leakage Current UNIT 2.3 IF = 15A VF MAX Volts IF = 15A, TJ = 150°C 1.9 VR = VR Rated 250 VR = VR Rated, TJ = 125°C 500 µA CT Junction Capacitance, VR = 200V 12 pF LS Series Inductance (Lead to Lead 5mm from Base) 10 nH USA APT Website - http://www.advancedpower.com 405 S.W. Columbia Street Bend, Oregon 97702-1035 Phone: (541) 382-8028 FAX: (541) 388-0364 F-33700 Merignac - France Phone: (33) 5 57 92 15 15 FAX: (33) 5 56 47 97 61 EUROPE Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord 053-0018 Rev - Symbol APT15D100BHB DYNAMIC CHARACTERISTICS Symbol Characteristic MIN TYP MAX 75 trr1 Reverse Recovery Time, IF = 1.0A, diF /dt = -15A/µs, VR = 30V, TJ = 25°C 60 trr2 Reverse Recovery Time TJ = 25°C 60 trr3 IF = 15A, diF /dt = -100A/µs, VR = 540V TJ = 100°C 120 tfr1 Forward Recovery Time TJ = 25°C 180 tfr2 IF = 15A, diF /dt = 100A/µs, VR = 540V TJ = 100°C 180 IRRM1 Reverse Recovery Current TJ = 25°C 3.8 7 IRRM2 IF = 15A, diF /dt = -100A/µs, VR = 540V TJ = 100°C 4.5 9 Qrr1 Recovery Charge TJ = 25°C 114 Qrr2 IF = 15A, diF /dt = -100A/µs, VR = 540V TJ = 100°C 270 Vfr1 Forward Recovery Voltage TJ = 25°C 5.8 Vfr2 IF = 15A, diF /dt = 100A/µs, VR = 540V TJ = 100°C 5.8 Rate of Fall of Recovery Current TJ = 25°C 100 IF = 15A, diF /dt = -100A/µs, VR =540V (See Figure 10) TJ = 100°C 50 diM/dt UNIT ns Amps nC Volts A/µs THERMAL AND MECHANICAL CHARACTERISTICS Symbol Characteristic / Test Conditions MIN TYP RθJC Junction-to-Case Thermal Resistance 1.7 RθJA Junction-to-Ambient Thermal Resistance 80 WT Torque UNIT MAX °C/W 0.07 oz 1.9 gm Package Weight 6.4 lb•in 0.7 N•m Maximum Mounting Torque (Screw Type = 6-32 or 3.5mm Machine) 2.0 D=0.5 0.5 0.2 0.1 0.1 0.05 0.05 0.02 NOTE: 0.01 PDM Z JC, THERMAL IMPEDANCE (°C/W) θ 1.0 t1 SINGLE PULSE DUTY FACTOR D = t1 / t2 053-0018 Rev - 0.01 0.005 10-5 t2 PEAK TJ =PDM x Z JC + TC 10-4 10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (SECONDS) Figure 1, Maximum Effective Transient Thermal Impedance, Junction-To-Case vs Pulse Duration 10 APT15D100BHB 60 Qrr, REVERSE RECOVERY CHARGE (nano-COULOMBS) 2500 40 30 20 TJ = 25°C TJ = 150°C TJ = -55°C TJ = 100°C 10 0 0 1 2 3 4 VF, ANODE-TO-CATHODE VOLTAGE (VOLTS) Figure 2, Forward Voltage Drop vs Forward Current 2000 30A 1500 15A 1000 500 7.5A 0 10 50 100 500 1000 diF /dt, CURRENT SLEW RATE (AMPERES/µSEC) Figure 3, Reverse Recovery Charge vs Current Slew Rate 2.0 50 TJ = 100°C VR = 540V 30A 40 Kf, DYNAMIC PARAMETERS (NORMALIZED) IRRM, REVERSE RECOVERY CURRENT (AMPERES) TJ = 100°C VR = 540V 15A 30 7.5A 20 10 0 0 200 400 600 800 1000 diF /dt, CURRENT SLEW RATE (AMPERES/µSEC) Figure 4, Reverse Recovery Current vs Current Slew Rate 1.6 Qrr trr 1.2 0.8 0.4 0.0 Qrr -25 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (°C) Figure 5, Dynamic Parameters vs Junction Temperature -50 TJ = 100°C VR = 540V IF = 15A tfr, FORWARD RECOVERY TIME (nano-SECONDS) trr, REVERSE RECOVERY TIME (nano-SECONDS) TJ = 100°C VR = 540V 30A 15A 120 80 400 200 160 IRRM trr 7.5A 80 40 0 0 200 400 600 800 1000 diF /dt, CURRENT SLEW RATE (AMPERES/µSEC) Figure 6, Reverse Recovery Time vs Current Slew Rate 60 300 Vfr 200 40 20 100 tfr Vfr, FORWARD RECOVERY VOLTAGE (VOLTS) IF, FORWARD CURRENT (AMPERES) 50 0 0 0 200 400 600 800 1000 diF /dt, CURRENT SLEW RATE (AMPERES/µSEC) Figure 7, Forward Recovery Voltage/Time vs Current Slew Rate 100 50 10 0.01 0.05 0.1 Figure 8, Junction Capacitance vs Reverse Voltage 0.5 1 5 VR, REVERSE VOLTAGE (VOLTS) 10 50 100 200 053-0018 Rev - CJ, JUNCTION CAPACITANCE (pico-FARADS) 200 APT15D100BHB Vr D.U.T. trr/Qrr Waveform 30µH PEARSON 411 CURRENT TRANSFORMER +15v diF /dt Adjust 0v -15v Figure 9, Diode Reverse Recovery Test Circuit and Waveforms 1 IF - Forward Conduction Current 2 diF /dt - Current Slew Rate, Rate of Forward Current Change Through Zero Crossing. 3 IRRM - Peak Reverse Recovery Current. 4 trr - Reverse Recovery Time Measured from Point of IF 1 4 6 Zero 5 3 Current Falling Through Zero to a Tangent Line { 6 diM/dt} Extrapolated Through Zero Defined by 0.75 and 0.50 IRRM. 0.5 IRRM 0.75 IRRM 2 5 Qrr - Area Under the Curve Defined by IRRM and trr. 6 diM/dt - Maximum Rate of Current Change During the Trailing Portion of trr. Qrr = 1/2 (trr . IRRM) Figure 10, Diode Reverse Recovery Waveform and Definitions TO-247 Package Outline 4.69 (.185) 5.31 (.209) 1.49 (.059) 2.49 (.098) 15.49 (.610) 16.26 (.640) 6.15 (.242) BSC 5.38 (.212) 6.20 (.244) Anode 1 / Cathode 2 20.80 (.819) 21.46 (.845) 3.55 (.140) 3.81 (.150) 4.50 (.177) Max. 0.40 (.016) 0.79 (.031) 2.87 (.113) 3.12 (.123) 1.65 (.065) 2.13 (.084) 19.81 (.780) 20.32 (.800) 1.01 (.040) 1.40 (.055) Cathode 1 Anode 1 / Cathode 2 Anode 2 053-0018 Rev - 2.21 (.087) 2.59 (.102) 5.45 (.215) BSC 2-Plcs. Dimensions in Millimeters and (Inches) APT Reserves the right to change, without notice, the specifications and information contained herein.