!Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensors Murata Manufacturing Co., Ltd. Cat.No.S21E-4 S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. CONTENTS S21E.pdf 05.11.16 HIC® in this catalog are the trademarks of Murata Manufacturing Co., Ltd. Part Numbering 1 1 Dual Type Pyroelectric Infrared Sensor IRA-E700 Series 2 2 Quad Type Pyroelectric Infrared Sensor IRA-E900 Series 3 3 Quad Type Pyroelectric Infrared Sensor IRA-E940ST1 Series 4 4 Temperature Compensation Single Type Pyroelectric Infrared Sensor IRA-E420 Series Pyroelectric Infrared Sensor IRA Series Characteristics Data 5 7 Fresnel Lens 10 Notice 13 Recycled Paper !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 o Part Numbering Pyroelectric Infrared Sensor (Part Number) IR A- E710ST q w e 1 r qProduct ID wType eCharacteristics rIndividual Specification Code * Part Number shows only an example which might be different from actual part number. * "eCharacteristics" and "rIndividual Specification Code" might have different digit number from actual Part Number. 1 S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. 1 Pyroelectric Infrared Sensors Dual Type Pyroelectric Infrared Sensor IRA-E700 Series Pyroelectric infrared sensors, IRA series, exhibit high sensitivity and reliable performance made possible by Murata's ceramic technology and Hybrid IC technique expertise developed over many years. IRA-E700 series realizes cost benefits and higher performance with a new infrared sensor element of improved material parameters and fabrication. IRA-E700 series is available in two types. IRA-E710ST0 has enhanced immunity to RFI (Radio Frequency Interference). ! Features ! Dimensions & Circuit Diagrams 4.7±0.1 45° 3.7±0.1 9.2 1. High sensitivity and excellent S/N ratio 2. High stability to temperature changes 3. Slight movement can be detectable. 4. High immunity to external noise (Vibration, RFI etc.) 5. Custom design is available. 6. Higher in cost-performance ! Applications 45° φ0.45 ±0.05 IRA-E710ST0 4.3mVp-p (Typ.) Field of View θ1=θ2=45° Optical Filter 5µm long-pass Electrode (2.0Z1.0mm)Z2 d g 2 to 15V Operating Temperature -40 to 70D Storage Temperature -40 to 85D s General Tolerance : ±0.2 (in mm) Pyroelectric element 2.0 Supply Voltage ∗ IRA-E700ST0 05 0. 0± Part Number ∗Specified on the bottom of stem 5. !Rating (25˚C) Responsivity (500K, 1Hz, 1Hz) 11.0±2 3.6 4.7 1. Security 2. Lighting appliances 3. Household or other appliances 1.0 1.0 1.0 (in mm) d IRA-E700ST0 s RG g IRA-E710ST0 d s RG g 2 S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensors Quad Type Pyroelectric Infrared Sensor IRA-E900 Series 2 Pyroelectric infrared sensors, IRA series, exhibit high sensitivity and reliable performance made possible by Murata's ceramic technology and Hybrid IC technique expertise developed over many years. IRA-E900 series realizes cost benefits and higher performance with a new infrared sensor element of improved material parameters and fabrication. IRA-E900 series is available in two types. IRA-E910ST1 has enhanced immunity to RFI (Radio Frequency Interference). ! Features ! Dimensions & Circuit Diagrams 4.7±0.1 41° 9.2 1. High sensitivity and excellent S/N ratio 2. High stability to temperature changes 3. Slight movement can be detectable. 4. Non directional sensing with wide F.O.V. 5. High immunity to external noise (Vibration, RFI etc.) 6. Custom design is available. 7. Higher in cost-performance 41° 1. Security 2. Lighting appliances 3. Household or other appliances φ0.45 ±0.05 11.0±2 3.6 4.7 ! Applications ∗Specified on the bottom of stem 5.08±0.05∗ ! Rating (25˚C) Responsivity (500K, 1Hz, 1Hz) Field of View IRA-E900ST1 s General Tolerance : ±0.2 g 3.3mVp-p (Typ.) (in mm) θ1=θ2=41° Optical Filter 5µm long-pass Electrode (1.1Z1.1mm)Z4 Supply Voltage d IRA-E910ST1 Pyroelectric element 1.1 1.0 1.1 Part Number 3 to 15V Operating Temperature -25 to 55D Storage Temperature -40 to 85D (in mm) 1.1 1.0 1.1 d IRA-E900ST1 W Y Y W W Y Y W Y W W Y Y W W Y s RG g IRA-E910ST1 d W Y Y W W Y Y W Y W W Y Y W W Y s RG g 3 S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensors Quad Type Pyroelectric Infrared Sensor IRA-E940ST1 Series ! Features ! Dimensions & Circuit Diagrams 4.7±0.1 50° 9.2 1. High sensitivity and excellent S/N ratio 2. High stability to temperature changes 3. High immunity to external noise (Vibration, RFI etc.) 4. Higher in cost-performance 5. Custom design is available. ! Applications 55° 3.6 4.7 1. Security 2. Lighting appliances 3. Household or other appliances φ0.45 ±0.05 11.0±2 ∗Specified on the bottom of stem ! Rating (25˚C) ∗ Part Number IRA-E940ST1 Responsivity (500K, 1Hz, 1Hz) 3.3mVp-p (Typ.) Field of View θ1=55°, θ2=50° Optical Filter 5µm long-pass Electrode Supply Voltage 5.08±0.05 s1 d g s2 General Tolerance : ±0.2 (in mm) (1.35Z1.0mm)Z4 2 to 15V Operating Temperature -25 to 55D Storage Temperature -40 to 85D Pyroelectric element (Y) W Y (W) (Y) W Y (W) 1.35 0.3 1.35 3 Pyroelectric infrared sensors, IRA series, exhibit high sensitivity and reliable performance made possible by Murata's ceramic technology and Hybrid IC technique expertise developed over many years. IRA-E940ST1 realizes cost benefits and higher performance with a new infrared sensor element of improved material parameters and fabrication. IRA-E940ST1 which has quad elements and 2 outputs will detect the human body more correctly with OR/AND logic circuit. (in mm) 1.0 0.8 1.0 d RG s1 g RG s2 4 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 Pyroelectric Infrared Sensors Temperature Compensation Single Type Pyroelectric Infrared Sensor IRA-E420 Series Single type pyroelectric infrared sensors IRA-E420 series have a temperature compensation element. They are suitable for flame detection and gas detection. ! Features 1. High stability against abrupt ambient temperature changes 2. High immunity to external noise (Vibration, RFI etc.) 3. Custom design is available with varying optical filter. 4 ! Applications Optical Filter Applications Silicon 1-15µm infrared detection IRA-E420QW1 4.3µm band-pass Flame detection IRA-E420SW1 4.45µm band-pass Flame detection Part Number IRA-E420S1 ! Dimensions & Circuit Diagrams (IRA-E420S1, IRA-E420QW1) (IRA-E420SW1) 1.5 max. 2.4±0.1 3.0±0.1 9.2 9.2 17° 17° 11.0±2 ø0.45±0.05 5.08±0.05∗ d s 4.5 11±2 ø0.45 ±0.05 3.6 3.6 4.9 50° 5.08±0.05 ∗ ∗Specified on the bottom of stem ∗Specified on the bottom of stem d General Tolerance : ±0.2 (in mm) g s g General Tolerance : ±0.2 (in mm) Pyroelectric element 1.8 Pyroelectric element 1.6 (in mm) (in mm) d RG s g 5 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 ! Rating (25˚C) Part Number Responsivity (500K, 1Hz, 1Hz) IRA-E420S1 IRA-E420QW1 IRA-E420SW1 3.4mVp-p (Typ.) 1.3mVp-p (Typ.)* 0.45mVp-p (Typ.) 4.3µm band-pass 4.45µm band-pass Optical Filter Silicon 3 to 15V Supply Voltage Storage Temperature * 700K, 5Hz, 1Hz 4 6 ø1.8mm ø1.6mm Electrode Operating Temperature θ1=θ2=50° θ1=θ2=17° Field of View -25 to 70D -25 to 55D -30 to 100D -25 to 70D S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensor IRA Series Characteristics Data ! Spectral Response of Window Materials Wave length (µm) 2.5 3.0 4.0 5.0 6.0 7.0 8.0 10.0 12.0 100 5µm Long-Pass Filter 80 Transmittance (%) 4.3µm Band-Pass Filter 60 40 Silicon Filter 20 7µm Long-Pass Filter 4 0 4000 3500 3000 2500 2000 1800 1600 1400 1200 1000 800 Wave number (cm-1) ! Frequency Characteristics Relative Responsivity (RV) 10 1 1.0 10 Chopping Frequency (Hz) 7 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 Pyroelectric Infrared Sensor IRA Series Characteristics Data ! Test Method of Sensitivity Lock-in Amplifier (1Hz) 140mm W5V d Black Body 47kΩ s 500K*1 W 22µF g Mechanical Chopper 1Hz*1 Infrared Sensor Oscilloscope Mechanical Chopper Black Body *1 IRA-E420QW1 700K 5Hz IRA-E420SW1 400K 2.5Hz IRA-E700/E900 Series 500K 1Hz 4 ! Typical Application Circuit (Human Detection) 3 Terminal Regulater 78L05 B102K D LM358 120k S g 100k 1 120k W 4.7µ 16V B102K B102K 10M B222K 1S184 330k 3.3µ 16V 100k W 100k 260k B222K 220k 10M 4 2 1S184 NJM 2903M R 6 100k LM358 330k B102K 220k 8 100k 2SD596 10µ 16V W10µ 16V C W 1 µPD5555G W 100µ W 100µ 16V 16V Relay 1k 5 B103K GND TH=1.1ZC (µF) Z R (MΩ) second 8 Photo Coupler 3 7 W 9Y15 100k !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 Pyroelectric Infrared Sensor IRA Series Characteristics Data ! Reliability Test IRA-E700 series, IRA-E900 series 100D for 500 hrs. Low Temperature Y40D for 500 hrs. Humidity 60D, 95% RH for 500 hrs. After test completion, leave for three hours in normal humidity temperature conditions, and then measure. 20 times of following cycle. Heat Cycle Y25D, 30 min.eRoom temp., 30 min.h gRoom temp., 30 min.f55D, 30 min. Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3 Vibration perpendicular directions for 60 min. Apply shock of 100G sinewave by standard shock tester to each of 3 Shock perpendicular directions. Soldering Heat Immerse up to 3.0mm from can case in solder bath of 260T5D for 10T1 s. Conform to MIL-STD-202F chapter 112D, condition D. Hermetic Sealing Criteria Test Conditions Item High Temperature Immerse in fluorocarbon bath (FC-40) of 125T5D for 20 s. 1. External appearance: No significant damage 2. Sensitivity: Tolerance within 20% deviation from original value 3. Noise: Maximum tolerance W100mV of original value No generation of bubbles 4 IRA-E420 series 100D for 500 hrs. Low Temperature Y30D for 500 hrs. Humidity 60D, 95% RH for 500 hrs. 20 times of following cycle. Heat Cycle Y25D, 30 min.eRoom temp., 30 min.h gRoom temp., 30 min.f55D, 30 min. Apply vibration of amplitude of 1.5mm with 10 to 55Hz band to each of 3 Vibration perpendicular directions for 60 min. Apply shock of 100G sinewave by standard shock tester to each of 3 Shock Soldering Heat perpendicular directions. Immerse up to 3.0mm from can case in solder bath of 260T5˚C for 10T1 s. Conform to MIL-STD-202F chapter 112D, condition D. Hermetic Sealing Criteria Test Conditions Item High Temperature Immerse in fluorocarbon bath (FC-40) of 125T5D for 20 s. After test completion, leave for three hours in normal humidity temperature conditions, and then measure. 1. External appearance: No significant damage 2. Sensitivity: Tolerance within 20% deviation from original value 3. Noise: Maximum tolerance W100mV of original value No generation of bubbles 9 S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensors/Fresnel Lens 16.3 E' m 3.0 C C C B E D A D' B' C' PPGI0601 2.0 B 1.0 D B D A E 11.64 R 16.0 6.4 5.0 3.64 B B' A 30° 1.0 E, E' 0 C' Cross-Sectional View 1.0 2.0 3.0 4.0 5.0 m C' 3.0 2.24 3.60 C C' 22.5° A D' B' D' B' E' 2.0 φ20.0 φ21.0 D, D' 3.0 Vertical Area 2.0 Horizontal Area 0 1.0 4 m 4.0 1.0 2.0 3.0 4.0 5.0 m (in mm) PPGI0902 Horizontal Area Sensor Vertical Area 7.7m 21.5 9m 8 10 44.5 2m R 29.6 Sensor 10m 1.6m 3.5m 9m 51.5 56.5 7.7m (in mm) 29.6R Lens plane 10 0.7max. 1m 12° 10m S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensors/Fresnel Lens PPGI0626 φ23T0.2 12.9SR SR Pyroelectric element A 3 12 .1 φ19.4 2 φ21.4 B C 3.6 6 3 (in mm) Detection area on the floor B : 60° pitch C : 30° pitch 4 0.5m 2.5m Y 16.5 3 (m) Y C C1 C2 2.2m 2 C12 B1 C3 B C11 C10 C4 1 Z A X 0.8m B2 0 B6 1 B3 B B5 C9 C5 2 B4 C6 3 C C8 C7 Y A : 0° B : 21.8° C : 48° IML-0635 6m Tab (4.5) 13º 5m 1.15 4.0 5.5 R4.8 5.2 5.7 1) Insert a sensor into Fresnel lens like each tab is overlapped. (In case there are two tabs on Fresnel lens, the field of view is determined by your choice (TabA or B on Fresnel lens). Please see following page(s) for more details to see which characteristic of field of view is preferable for your application.) 2) Push the sensor into Fresnel lens until the top face of sensor reaches to the stopper inside Fresnel lens. 3) Please prepare a housing yourself that is put onto Fresnel lens as shown in FigureA. The hatching area shown in Figure A, must be obscured by the housing in order to prevent misdetection. Unless otherwise unexpected infrared ray comes though the hatching area. (in mm) General tolerance : ±0.2 0m 1.8m 10.8m Figure A 2m 35º 9.15 Housing 35º Pyro-Element (4.35) 3.4 4.35 8.65 4.5 Step 3.0 1.15 5.7 13º ø8.2 ø9.0 0m 2m Vertical 6m Horizontal *Assembled with Murata sensor IRA-700 series 11 S21E.pdf 05.11.16 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. Pyroelectric Infrared Sensors/Fresnel Lens IML-0636 0.5 0.5 Tab 13º ø8.2 ø9.0 (4.5) 4m 13º 5m 3m 0m 1) Insert a sensor into Fresnel lens like each tab is overlapped. (In case there are two tabs on Fresnel lens, the field of view is determined by your choice (TabA or B on Fresnel lens). Please see following page(s) for more details to see which characteristic of field of view is preferable for your application.) 2) Push the sensor into Fresnel lens until the top face of sensor reaches to the stopper inside Fresnel lens. 3) Please prepare a housing yourself that is put onto Fresnel lens as shown in FigureA. The hatching area shown in Figure A, must be obscured by the housing in order to prevent mis-detection. Unless otherwise unexpected infrared ray comes though the hatching area. 4 0m 19.3º Figure A Focal point (Pyro-Element) 19.3º 19.3º 5.54m ø10.4 19.3º 6.6m Housing 9.15 (4.35) 0.5 3.4 4.5 8.65 Step 3m Vertical 4m Horizontal *Assembled with Murata sensor IRA-700 series (in mm) General tolerance : ±0.2 IML-0637 0.5 0.5 Tab 13º ø8.2 ø9.0 (4.5) 13º 5m 5m 2m 2m 0m Figure A Focal point (Pyro-Element) 1) Insert a sensor into Fresnel lens like each tab is overlapped. (In case there are two tabs on Fresnel lens, the field of view is determined by your choice (TabA or B on Fresnel lens). Please see following page(s) for more details to see which characteristic of field of view is preferable for your application.) 2) Push the sensor into Fresnel lens until the top face of sensor reaches to the stopper inside Fresnel lens. 3) Please prepare a housing yourself that is put onto Fresnel lens as shown in FigureA. The hatching area shown in Figure A, must be obscured by the housing in order to prevent mis-detection. Unless otherwise unexpected infrared ray comes though the hatching area. 2m 1.8m ø10.4 2.7m Housing 9.15 (4.35) 0.5 3.4 4.5 8.65 Step 0m 2m Vertical Horizontal *Assembled with Murata sensor IRA-700 series (in mm) General tolerance : ±0.2 IML-0638 3m 6.11m 3m 42° Tab 13º ø8.2 ø9.0 (4.5) 13º 0m 4.91m Pyro-Element R4.8 1.15 4.0 5.5 5.7 3.0 1.15 5.2 5.7 Housing 9.15 (4.35) 3.4 4.35 8.65 4.5 Step 42° 3m Figure A 1) Insert a sensor into Fresnel lens like each tab is overlapped. (In case there are two tabs on Fresnel lens, the field of view is determined by your choice (TabA or B on Fresnel lens). Please see following page(s) for more details to see which characteristic of field of view is preferable for your application.) 2) Push the sensor into Fresnel lens until the top face of sensor reaches to the stopper inside Fresnel lens. 3) Please prepare a housing yourself that is put onto Fresnel lens as shown in FigureA. The hatching area shown in Figure A, must be obscured by the housing in order to prevent misdetection. Unless otherwise unexpected infrared ray comes though the hatching area. (in mm) General tolerance : ±0.2 On the Floor 3m Vertical 0m 3m Vertical Horizontal 45.5° 45.5° Horizontal Pyroelectric Element Assembled with Murata sensor IRA-700 Series. Freshel lens are available upon request. 12 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 Notice ! Notice 1. Caution (Design) (1) Please make sure that your product has been evaluated and confirmed against your specifications when our product is mounted to your product. (2) Be sure to provide an appropriate fail-safe function on your product to prevent a second damage that may be caused by the abnormal function or the failure of our product. (3) In case of outdoor use, suitable optical filter and water and humidity proof structure should be applied. (4) To prevent failure or malfunction, please use a stabilized power supply. (5) Please avoid using the sensor in the following conditions because it may cause failure or malfunction. (a) in such a fluid as water, alcohol etc. corrosive gas (SO2, Cl2, NOX etc.) or sea breeze (b) in high humidity (c) in a place exposed directly to sunlight or headlights of automobile (d) in a place exposed to rapid ambient temperature change (e) in a place exposed directly to an air-conditioner or heat vent (f) strong vibrations (g) in a place exposed to strong electromagnetic field (h) in such a place where infrared ray is shaded (i) in any other place similar to the above (a) through (h) 2. Caution (Mounting) (1) Soldering (a) Hand soldering should be applied. (b) Soldering should be done quickly as following. Temperature of soldering iron : 350˚C Distance from can case Period of time 1 to 3mm Within 3 seconds per point Over 3mm Within 10 seconds per point (c) Soldering flux should be rosin flux and not contain more than 0.2wt% chlorine. Soldering flux should be removed after soldering. (2) Cleaning Soldering flux should be removed after soldering. Soldering flux may cause malfunction or degradation of character unless sufficiently cleaned. 3. Caution (Handling and Storage) (1) The optical filter of the sensor should not be scratched or soiled. (2) Strong shock should be avoided. (3) Electrostatics and strong electromagnetic field should be avoided. (4) The sensor should be kept on conductive sponge. (5) High temperature, high humidity, fluid such as water or alcohol etc., corrosive gas (SO2, Cl2, NOX etc.) and sea breeze should be avoided. 13 !Note Please read rating and !CAUTION (for storage, operating, rating, soldering, mounting and handling) in this PDF catalog to prevent smoking and/or burning, etc. This catalog has only typical specifications. Therefore, you are requested to approve our product specifications or to transact the approval sheet for product specificaions before ordering. S21E.pdf 05.11.16 Note: 1. Export Control For customers outside Japan No muRata products should be used or sold, through any channels, for use in the design, development, production, utilization, maintenance or operation of, or otherwise contribution to (1) any weapons (Weapons of Mass Destruction (nuclear, chemical or biological weapons or missiles) or conventional weapons) or (2) goods or systems specially designed or intended for military end-use or utilization by military end-users. For customers in Japan For products which are controlled items subject to the “Foreign Exchange and Foreign Trade Law” of Japan, the export license specified by the law is required for export. < < > > 2. Please contact our sales representatives or product engineers before using the products in this catalog for the applications listed below, which require especially high reliability for the prevention of defects which might directly damage a third party's life, body or property, or when one of our products is intended for use in applications other than those specified in this catalog. q Aircraft equipment w Aerospace equipment e Undersea equipment r Power plant equipment t Medical equipment y Transportation equipment (vehicles, trains, ships, etc.) u Traffic signal equipment i Disaster prevention / crime prevention equipment o Data-processing equipment !0 Application of similar complexity and/or reliability requirements to the applications listed above 3. Product specifications in this catalog are as of August 2005. They are subject to change or our products in it may be discontinued without advance notice. Please check with our sales representatives or product engineers before ordering. If there are any questions, please contact our sales representatives or product engineers. 4. Please read rating and CAUTION (for storage, operating, rating, soldering, mounting and handling) in this catalog to prevent smoking and/or burning, etc. 5. This catalog has only typical specifications because there is no space for detailed specifications. Therefore, please approve our product specifications or transact the approval sheet for product specifications before ordering. 6. Please note that unless otherwise specified, we shall assume no responsibility whatsoever for any conflict or dispute that may occur in connection with the effect of our and/or a third party's intellectual property rights and other related rights in consideration of your use of our products and/or information described or contained in our catalogs. In this connection, no representation shall be made to the effect that any third parties are authorized to use the rights mentioned above under licenses without our consent. 7. No ozone depleting substances (ODS) under the Montreal Protocol are used in our manufacturing process. http://www.murata.com/ Head Office 1-10-1, Higashi Kotari, Nagaokakyo-shi, Kyoto 617-8555, Japan Phone: 81-75-951-9111 International Division 3-29-12, Shibuya, Shibuya-ku, Tokyo 150-0002, Japan Phone: 81-3-5469-6123 Fax: 81-3-5469-6155 E-mail: [email protected]