IVO N214.012AX01 Totalizers electronic Datasheet

Totalizers electronic
Large impulse counters and position displays
Display LED, 6-digits, programmable
N 214
Features
–– Totalizer and position display
–– Display 6-digits
–– Set value, scaling factor, momentary signal duration
and operating mode programmable
–– Connection: Incremental encoder or digital sensors
–– Interface RS232, RS422, RS485
Technical data - electrical ratings
Voltage supply
115/230 VAC ±10 % (50/60 Hz)
24/48 VAC ±10 % (50/60 Hz)
12...30 VDC
Programmable
parameters
Decimal point
Sensor logic, scaling factor
Count mode, measuring units
Power consumption
7 VA, 5 W
Approvals
UL/cUL, CE conform
Sensor supply
12...26 VDC / max. 100 mA
Display
LED, 7-segment display
Technical data - mechanical design
Number of digits
6-digits
Digit height
14 mm
Operating temperature
0...+50 °C
Function
Totalizer
Difference counter A - B
Parallel counter A + B
Position display
Storing temperature
-20...+70 °C
Relative humidity
80 % non-condensing
E-connection
Plug-in screw terminals
Core cross-section
1.5 mm²
0.0001...9999.99
Protection DIN EN 60529
IP 65 face with seal
Adding or subtracting
A-B (difference counting)
A+B total (parallel counting)
Up/Down
A 90° B phase evaluation
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
96 x 48 x 124 mm
Installation depth
124 mm
3 Hz, 25 Hz, 10 kHz
programmable
Mounting
Clip frame
Measuring range
-99 999...+999 999
Cutout dimensions
92 x 45 mm (+0.6)
Data memory
>10 years in EEPROM
Materials
Housing: Makrolon 6485 (PC)
Keypad: Polyester
Reset
Button and electric
Weight approx.
350 g (AC), 250 g (DC)
Keylock
Yes, electric (keylock)
Outputs electronic
Optocoupler
Outputs relay
Potential-free change-over
contact
Output holding time
0.01...9.99 s
Interfaces
RS232, RS422, RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
Scaling factor
Count modes
Counting frequency
1
www.baumerivo.com
30/10/2008
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
N 214 - Totalizer
Totalizers electronic
Large impulse counters and position displays
Display LED, 6-digits, programmable
N 214
Part number
Block circuit diagram
N 214.
AX01
Voltage
supply
Voltage supply
1 24 / 48 VAC
2 115 / 230 VAC
3 24 VDC
2
4
+
3
5
Signal input
A
B
Outputs
0 Without relay
1 Relay and optocoupler outputs
0
1
2
3
-
10
A 90° B
Totalizer with
start count
scaling factor
7
8
Stop/Hold
9
SC- / 0
11
Output
20
21
14
SC- / 0
22
Interface
RS485
T,R+ 15
Interface
Without interface
RS485
RS422
RS232
+
Output
6
Reset
T,R-
Sensor
supply
-
TxD+ 16
TxD- 17
Interface
RS422
RxD+ 18
RxD- 19
TxD
16
RxD
18
Interface
RS232
GND 19
Connection diagram
TxD
Count
5
4
0V
6
+24V
Track B
7
Track A
Stop
8
Reset
SC- / 0
Output
T,R-
T,R+
RS485
9
3
2
1
Supply voltage
RS232
15 14 13 12 11 10
Sensor
supply
Input circuit
PNP- / NPN-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay output
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Electronic output
Output circuit
Optocoupler not short-circuit proof
Switching voltage max.
40 V
Switching current max.
15 mA
Dimensions
96
7
48
123.75
109
19.75
1-10
2
www.baumerivo.com
30/10/2008
TxDTxD+
RxD+
RxD-
RS422
RxD
max. 250V
terminal - terminal /
- terminal
GND
SC- / 0
Output
Comparator inputs
Inputs
Subject to modification in technic and design. Errors and omissions excepted.