SINGLE PHASE 10 AMP BRIDGE RECTIFIERS
VOLTAGE RANGE
50 to 1000 Volts
CURRENT
10.0 Amperes
BR-10
FEATURES
.296(7.5)
.255(6.5)
* Low forward voltage
.750
MIN.
(19.1)
* Low leakage current
.052(1.3) DIA.
.048(1.2) TYP.
* Mounting: Hole thru for #6 screw
* Mounting position: Any
.770(19.6)
.730(18.5)
HOLE FOR
NO. 6 SCREW
AC
.520(13.2) .770(19.6)
.480(12.2) .730(18.5)
AC
+
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
BR1005 BR101 BR102 BR104 BR106 BR108 BR1010 UNITS
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
50
35
50
100
70
100
200
140
200
400
280
400
600
420
600
800
560
800
1000
700
1000
V
V
V
.375"(9.5mm) Lead Length at Tc=50 C
Peak Forward Surge Current, 8.3 ms single half sine-wave
10
A
superimposed on rated load (JEDEC method)
Maximum Forward Voltage Drop per Bridge Element at 5.0A D.C.
Maximum DC Reverse Current
Ta=25 C
200
1.1
10
A
V
A
200
+125
+150
C
C
at Rated DC Blocking Voltage
Operating Temperature Range, TJ
Storage Temperature Range, TSTG
Ta=100 C
-65
-65
A
RATING AND CHARACTERISTIC CURVES (BR1005 THRU BR1010)
FIG.2-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
12
10
8
Single Phase
6
Half Wave 60Hz
Resistive Or Inductive Load
4
2
0
0
25
50
75
100 125
150
175
CASE TEMPERATURE,( C)
PEAK FORWARD SURGE CURRENT,(A)
AVERAGE FORWARD CURRENT,(A)
FIG.1-TYPICAL FORWARD CURRENT
DERATING CURVE
250
200
150
8.3ms Single Half
Tj=25 C
Sine Wave
100
JEDEC method
50
0
1
5
50
10
100
NUMBER OF CYCLES AT 60Hz
FIG.3-TYPICAL FORWARD
FIG.4-TYPICAL REVERSE
CHARACTERISTICS
CHARACTERISTICS
50
10
REVERSE LEAKAGE CURRENT, ( A)
INSTANTANEOUS FORWARD CURRENT,(A)
50
3.0
1.0
Tj=25 C
Pulse Width 300us
1% Duty Cycle
0.1
10
3.0
1.0
0.1
Tj=25 C
.01
0
.2
.4
.6
.8
1.0
FORWARD VOLTAGE,(V)
1.2
1.4
.01
0
20
40
60
80
100 120 140
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)