SICK FLG4-20018011 Switching automation light grid Datasheet

Online data sheet
FLG4-20018011
FLG
SWITCHING AUTOMATION LIGHT GRIDS
FLG4-20018011 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
A
B
C
D
E
F
Ordering information
Type
Part no.
FLG4-20018011
6049136
Other models and accessories
www.sick.de/FLG
Illustration may differ
Detailed technical data
Features
H
I
J
K
L
M
N
O
P
Q
R
S
T
Version
Close
Technology
Sender/receiver
Minimum detectable object (MDO)
Dynamic: 4 mm
Static: 6 mm
Beam separation
4 mm
Output function
Light/dark switching adjustable by means of rotary switch
Performance
Detection area (W x H)
180 mm x 200 mm
Response time
< 0.1 ms
Interfaces
Switching output
PNP/NPN (Q and /Q)
Connection type
M12, 4-pin male connector
Mechanics/electronics
Wave length
880 nm
Supply voltage Vs
DC 18 V ... 30 V 1)
Ripple
< 10 %
Output current Imax.
≤ 100 mA
Off delay
0 s ... 5 s 2)
Initialization time
0.3 s
Dimensions (W x H x D)
242 mm x 230 mm x 25 mm
Housing material
Aluminum, painted
Indication
LED
Enclosure rating
IP 65
1)
2)
2
Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
Adjustable.
AUTOMATION LIGHT GRIDS | SICK
Online data sheet | 2016-03-09 17:40:10
Subject to change without notice
FLG4-20018011 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
Circuit protection
UV connections, reverse polarity protected, Output Q short-circuit protected, Interference pulse
suppression
Weight
≥ 1 kg
Switching frequency
≤ 5,000 Hz
1)
2)
Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
Adjustable.
Ambient data
Protection class
III
EMC
EN 60947-5-2
Ambient temperature
Operation: 0 °C ... +60 °C 1)
Storage: –20 °C ... +80 °C
Ambient light immunity
Sunlight: 10,000 lx
Vibration resistance
EN 60068-2-6
Shock load
EN 60068-2-27
1)
In static mode: constant temperature around teaching point will be assumed.
Dimensional drawing (Dimensions in mm (inch))
FLGx-200xxx1x
50
4 x Ø 5 (0.20)
S
a
M12
22
R
(1.97)
a1
a
37
(1.46)
(0.87)
62
(2.44)
200 (7.87)
222.5 (8.76)
230 (9.06)
10.2
(0.40)
S
T
25
25
(0.98)
(0.98)
a1
FLGx-200120xx
182 (7.17)
120 (4.72)
FLGx-200180xx
242 (9.53)
180 (7.09)
FLGx-200250xx
312 (12.28)
250 (9.84)
Adjustments
NO
1
Stat.N
O
NC
Dyn. N
C
Indication LED
2
① Yellow LED: status output
② Red LED: error or button lock active (blinking)
2016-03-09 17:40:10 | Online data sheet

Subject
to change without notice
AUTOMATION LIGHT GRIDS | SICK
3
FLG4-20018011 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
A
B
C
D
E
F
Connection type and diagram
M12, 4-pin male connector
brn
1
wht
2
blu
3
blk
4
L+
nc
M
QPNP/NPN / Q̄PNP/NPN
Concept of operation
Setting key lock
S
NO
1
Dyn. N
C
T
Stat.N
O
NC
Unlocking:
1 To unlock the potentiometers,
turn the mode button on the
“Stat. NO” position.
2 Turn in less than 4 seconds,
on the “Dyn. NO”
position.
S
NO
2
Dyn.N
C
T
4
Stat.N
O
NC
H
I
J
K
L
M
N
O
P
Q
R
S
T
Locking:
After the last setting, the
frame waits 15 minutes then
locks the potentiometer.
When the potentiometers are
locked, the red LED flashes
every time you turn any button.
The potentiometers are then
unlocked and the settings are
updated with the current
position of the potentiometers.
<4s
Notice:
If the mode button is already
in the “Stat. NO” position,
change mode previously and
then apply the standard
unlocking procedure.
AUTOMATION LIGHT GRIDS | SICK
Online data sheet | 2016-03-09 17:40:10
Subject to change without notice
FLG4-20018011 | FLG
SWITCHING AUTOMATION LIGHT GRIDS
8.8
37.3
(0.35)
(1.49)
4
1
2
24.3 (0.96)
29.9 (1.18)
41.2 (1.62)
Diagramm
3
b
Dimensions in mm (inch)
b
b1
1 FLG2-xxx120xx
151.4 (5.96)
73.9 (2.91)
2 FLG2-xxx180xx
140.2 (5.52)
133.9 (5.27)
3 FLG2-xxx250xx
117.6 (4.63)
203.9 (8.03)
b1
All dimensions in mm (inch)
④ Side is missing in open version
Recommended accessories
Other models and accessories
www.sick.de/FLG
Brief description
Type
Part no.
DOL-1204-G05M
6009866
Plug connectors and cables
Head A: female connector, M12, 4-pin, straight
Head B: cable
Cable: PVC, unshielded, 5 m
2016-03-09 17:40:10 | Online data sheet

Subject
to change without notice
AUTOMATION LIGHT GRIDS | SICK
5
Online data sheet
SICK at a glance
SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.
We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.
Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity.
For us, that is “Sensor Intelligence.”
Worldwide presence:
Contacts and other locations – www.sick.com
SICK AG | Waldkirch | Germany | www.sick.com
Similar pages