FEATURES
Power Rating
1/6W, 1/4W, 1/2W, 1W, 2W, 3W
Resistance Tolerance
±2%, ±5%
T.C.R.
see Table 1
DERATING CURVE
For resistors operated in ambient temperatures above 70°C, power rating must be derated
in accordance with the curve below.
INTRODUCTION
The CFR Series Carbon Film Resistors are
manufactured by coating a homogeneous
film of pure carbon on high grade ceramic
rods. After a helical groove has been cut in
the resistive layer, tinned connecting leads of
electrolytic copper are welded to the end-caps.
The resistors are coated with layers of tan
color lacquer.
Rated Load (%)
70
155 °C
100
80
60
40
20
20
40
60
80
100 120 140 160
Ambient Temperature (°C)
TABLE 1 TEMPERATURE COEFFICIENT
STYLE
Temp. Coefficient (ppm/°C)
under 100KΩ
100K Ω - 1MΩ
1MΩ - 10MΩ
CFR100, CFR200, CFR2WS, CFR3WS
-350~350
-500~0
-1,500~0
CFR-12, CFR-25, CFR-50,
CFR25S, CFR50S, CFR1WS
-350~500
-700~0
-1,500~0
DIMENSIONS
Unit: mm
STYLE
ød
H
L
øD
DIMENSION
Normal
Miniature
L
øD
H
ød
CFR-12
CFR25S
3.4±0.3
1.9±0.2
28±2.0
0.45±0.05
CFR-25
CFR50S
6.3±0.5
2.4±0.2
28±2.0
0.55±0.05
CFR-50
CFR1WS
9.0±0.5
3.3±0.3
26±2.0
0.55±0.05
CFR100
CFR2WS
11.5±1.0
4.5±0.5
35±2.0
0.8±0.05
CFR200
CFR3WS
15.5±1.0
5.0±0.5
33±2.0
0.8±0.05
27
Note:
ELECTRICAL CHARACTERISTICS
STYLE
CFR-12
CFR25S
CFR-25
CFR50S
CFR-50
Power Rating at 70°C
1/6W
1/4W
Maximum Working Voltage
150V
200V
250V
300V
350V
400V
500V
Maximum Overload Voltage
300V
400V
500V
600V
700V
800V
1,000V
Voltage Proof on Insulation
300V
400V
500V
700V
1,000V
Resistance Range
1Ω - 10MΩ & 0Ω for E24 series value
Operating Temp. Range
-55°C to +155°C
Temperature Coefficient
see Table 1
1/2W
CFR1WS CFR100
CFR2WS CFR200
CFR3WS
1W
2W
3W
Note: Special value is available on request
ENVIRONMENTAL CHARACTERISTICS
PERFORMANCE TEST
TEST METHOD
APPRAISE
Short Time Overload
IEC 60115-1 4.13
2.5 times RCWV for 5 Sec.
±0.75%+0.05Ω
Voltage Proof on Insulation
IEC 60115-1 4.7
in V-block for 60 Sec., test voltage by type
By type
Temperature Coefficient
IEC 60115-1 4.8
-55°C to +155°C
By type
Insulation Resistance
IEC 60115-1 4.6
in V-block for 60 Sec.
>1,000MΩ
Solderability
IEC 60115-1 4.17
235±5°C for 3±0.5 Sec.
95% Min. coverage
Solvent Resistance of Marking
IEC 60115-1 4.30
IPA for 5±0.5 Min. with ultrasonic
No deterioration of
coatings and markings
Robustness of Terminations
IEC 60115-1 4.16
Direct load for 10 Sec. in the direction of the terminal leads
≥2.5kg (24.5N)
Periodic-pulse Overload
IEC 60115-1 4.39
4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec. off)
±1.0%+0.05Ω
Damp Heat Steady State
IEC 60115-1 4.24
40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV
±3.0%+0.05Ω
Endurance at 70°C
IEC 60115-1 4.25
70±2°C at RCWV for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off)
±3.0%+0.05Ω
Temperature Cycling
IEC 60115-1 4.19
-55°C  Room Temp.  +155°C  Room Temp. (5 cycles)
±1.0%+0.05Ω
Resistance to Soldering Heat
IEC 60115-1 4.18
260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body
±1.0%+0.05Ω
Note: RCWV(Rated Continuous Working Voltage) = Power Rating x Resistance Value or Max. working voltage listed above, whichever less.