AC/DC Converter LH10 Series 10W, AC-DC converter FEATURES Universal input range:85~264VAC, 100~370VDC Regulated output, low ripple and noise Over-current, short circuit and over- voltage protection Plastic case, meets UL94V-0 Meet UL60950,EN60950 standards 3 years product warranty PCB mounting, Chassis mounting, DIN-Rail mounting RoHS LH 10series -----a compact size power converter offered by Mornsun. It features universal input voltage, taking both DC and AC input voltage, low power consumption, high efficiency, high reliability, safer isolation. It offers good EMC performance, which meet IEC/EN61000-4, CISPR22/EN55022, UL60950 and EN60950 standards, and it’s widely used in industrial, office and civil applications. For harsh EMC environment, the application circuit in the datasheet is strongly recommended. Selection Guide Certification UL/CE Part No.* Output Power LH10-10B03 6.6 W UL/CE Efficiency (230VAC, %/Typ.) Max. Capacitive Load(µF) (Vo1/Io1) (Vo2/Io2) Vo1 Vo2 3.3V/2000mA -- 70 26400 -- LH10-10B05 5V/2000mA -- 76 9440 -- LH10-10B09 9V/1100mA -- 78 3600 -- LH10-10B12 12V/900mA -- 80 2400 -- LH10-10B15 15V/700mA -- 81 1170 -- LH10-10B24 24V/450mA -- 82 370 -- LH10-10A05 +5V/1000mA -5V/1000mA 76 8800 8800 LH10-10A12 +12V/450mA -12V/450mA 80 1970 1970 LH10-10A15 -- Nominal Output Voltage and Current +15V/350mA -15V/350mA 81 1970 1970 LH10-10A24 10W +24V/200mA -24V/200mA 84 660 660 LH10-10C0512-02 5V/1000mA ±12V/200mA 75 3200 260 LH10-10C0515-02 5V/900mA ±15V/200mA 75 2160 80 LH10-10D0505-02 5V/1800mA 5V/200mA 75 8000 540 LH10-10D0512-02 5V/1500mA 12V/200mA 79 4400 260 LH10-10D0515-02 5V/1400mA 15V/200mA 79 4400 170 LH10-10D0524-02 5V/1000mA 24V/200mA 81 4000 170 Note: LH10-10AXX, use both positive and negative output as sampling feedback; and all others use Vo1 as sampling feedback. Input Specifications Item Input Voltage Range Operating Conditions Min. Typ. Max. AC input 85 -- 264 VAC DC input 100 -- 370 VDC 47 -- 63 Hz 115VAC -- -- 0.26 230VAC -- -- 0.16 115VAC -- 10 -- 230VAC -- 20 -- Input frequency Input current Inrush current Leakage current Unit A 0.3mA RMS typ./230VAC/50Hz 2015.08.24-B/3 Page 1 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH10 Series Recommended External Input Fuse(Special package series include fuse) 2A/250V, slow fusing Hot Plug Unavailable Output Specifications Item Operating Conditions Output Voltage Accuracy Line Regulation Min. Typ. Max. Main circuit -- ±2 -- Main circuit(3.3V Output voltage) -- ±3 -- Main circuit -- ±0.5 -- Auxiliary circuit -- ±1.5 -- Single output -- ±1 -- Dual output(balanced load) -- ±2 -- Full load 10%-100% load Load Regulation Isolated triple output (balanced load) Main circuit -- ±3 -- Auxiliary circuit -- ±5 -- Isolated and separated twin output (balanced load) Main circuit -- ±3 -- Auxiliary circuit -- ±5 -- Unit % Ripple & Noise* 20MHz bandwidth (peak-peak value) -- 50 150 mV Temperature Coefficient Main circuit -- ±0.02 -- %/°C Short Circuit Protection Continuous, self-recovery ≥110%Io self-recovery Over-current Protection Over-voltage Protection Main circuit 3.3 / 5VDC Output ≤7.5VDC 9VDC Output ≤13VDC 12 /15VDC Output ≤20VDC 24VDC Output Min. Load Hold-up Time ≤30VDC Single output models 0 -- -- Dual output models (balanced load) 10 -- -- Isolated and separated twin output (balanced load) 10 -- -- Isolated triple output (balanced load) 10 -- -- 115VAC input -- 15 -- 230VAC input -- 80 -- % ms Note: * Ripple and noise are measured by “parallel cable” method, please see AC-DC Converter Application Notes for specific operation. General Specifications Item Isolation Voltage Input-output Operating Temperature Storage Temperature Operating Conditions Min. Test time: 1min 3000 -- -- LH10-10A24 -25 -- +70 Others -40 -- +70 LH10-10A24 -25 -- +105 Others -40 -- +105 -- -- 95 Storage Humidity Welding Temperature Switching Frequency Power Derating Typ. Max. Unit VAC °C %RH Wave-soldering +260±5℃; time:5~10s Manual-welding +360±10℃; time:3~5s LH10-10A/LH10-10C/LH10-10D series -- 65 -- LH10-10B series -- 100 -- -40℃~-10℃ 2.0 -- -- +55℃~+70℃ 4.0 -- -- Safety Standard IEC60950/EN60950/UL60950 Safety Certification EN60950/UL60950 Safety Class CLASS I MTBF MIL-HDBK-217F@25°C > 300,000 h 2015.08.24-B/3 kHz %/°C Page 2 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH10 Series Physical Specifications Casing Material Black flame-retardant and heat-resistant plastic (UL94-V0) Horizontal package 55.00*45.00*21.00 mm A2 chassis mounting 96.10*54.00*29.50 mm A3 chassis mounting 99.00*54.00*29.50 mm A4 Din-Rail mounting 96.10*54.00*34.10 mm Weight Horizontal package/A2 chassis mounting /A3 chassis mounting/A4 Din-Rail mounting 80g/130g/130g/170g(Typ.) Cooling method* Free air convection Dimension Note: *This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE. EMC Specifications EMI EMS CE CISPR22/EN55022, CLASS B RE CISPR22/EN55022, CLASS B ESD IEC/EN61000-4-2 ±6KV/±8KV Perf. Criteria B RS IEC/EN61000-4-3 10V/m perf. Criteria A IEC/EN61000-4-4 ±2KV perf. Criteria B IEC/EN61000-4-4 ±4KV (See Fig. 5 for recommended circuit) perf. Criteria B IEC/EN61000-4-5 ±1KV/±2KV perf. Criteria B EFT Surge EMS IEC/EN61000-4-5 ±2KV/4KV (See Fig. 5 for recommended circuit) perf. Criteria B CS IEC/EN61000-4-6 10 Vr.m.s perf. Criteria A PFM Immunities of voltage dip, drop and short interruption IEC/EN61000-4-8 10A/m perf. Criteria A IEC/EN61000-4-11 0%-70% perf. Criteria B Temperature Derating Curve 100 80 70 60 40 Inpu t voltage: 85~264VAC 100~ 370VDC 20 -40 -25 -10 55 Ambient Temperatu re(℃ ) 70 Output Power Percentage(%) Output Power Percent age(%) Product Characteristic Curve Input Voltage Derating Cur ve 100 80 75 60 40 Ambie nt temperatu re:25℃ 20 240 85 100 340 100 120 Inpu t Voltage 264 370 VAC VDC Note: ①When input 85~100VAC/240~264VAC/100~120VDC/340~370VDC, it need to be voltage derated on basis of temperature derating; ②LH10-10A24 lowest temperature is -25℃ ③This product is suitable for use in natural air cooling environments, if in a closed environment, please contact our company’s FAE. 2015.08.24-B/3 Page 3 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH10 Series Design Reference 1. Typical application circuit F US E F US E A C(L) AC(L) +Vo C1 C2 TV S - Vo - Vo Fig. 1: LH10-10Bxx (SIngle Output) seriesTypical application circuit AC(L) F USE NTC + AC(L) M OV ACDC A C(N) AC(N) C1 C 2 TV S1 RL AC(L) NTC F USE + Vo1 AC(L) C 4 TV S2 RL C1 C 2 TV S1 RL C3 C 4 TV S2 RL C5 C 6 TV S3 RL - MO V ACDC A C(N) AC(N) + Vo2 +Vo2 C om C3 C 4 TV S2 -Vo2 RL Fig. 3: LH10-10Dxx (Isolate Twin Output) series typical application circuit Model LH10-10B03 LH10-10B05 LH10-10B09 LH10-10B12 LH10-10B15 LH10-10B24 LH10-10A05 LH10-10A12 LH10-10A15 LH10-10A24 LH10-10C0512-02 LH10-10C0515-02 LH10-10D0505-02 LH10-10D0512-02 LH10-10D0515-02 LH10-10D0524-02 C3 Fig. 2: LH10-10Axx (Dual Output) series typical application circuit Vo1 - - RL AC DC A C(N) C om A C(N ) RL A C(N) C 1 C 2 TV S1 +Vo A C(L) MO V AC DC MO V A C(N ) NTC A C(L) NTC C2(µF) 470 330 120 120 120 68 220 120 47 33 220 220 220 220 220 220 C4(µF) Fig. 4: LH10-10Cxx (Triple Output) series typical application circuit C6(µF) 220 120 47 33 68 47 68 68 47 47 TVS1 SMBJ7.0A SMBJ7.0A SMBJ12A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A SMBJ7.0A 68 47 TVS2 SMBJ20A SMBJ20A SMBJ30A SMBJ20A SMBJ20A SMBJ7.0A SMBJ20A SMBJ20A SMBJ30A TVS3 SMBJ20A SMBJ20A Note: Note: Output filtering capacitors C2, C4, C6 are electrolytic capacitors, it is recommended to use high frequency and low impedance electrolytic capacitor. For capacitance and current of capacitor please refer to manufacture’s datasheet. Capacitor withstand voltage derating should be 80% or above. C1,C3, C5 are ceramic capacitors, which is used to filter high-frequency noise. TVS is a recommended component to protect post-circuits if converter fails. External input FUSE model is recommended to use 2A/250V slow fusing. External input NTC model is recommended to use 5D-9. External input MOV model is recommended to use S14K300. 2. EMC solution-recommended circuit Can u se M OR NSUN ' s FC-LX1 D FUSE LDM LCM AC( L) AC( L) +Vo CY1 C1 C2 TVS1 RL + ACDC MOV1 CX CY2 -Vo AC( N) AC( N) Fig 5: EMC Recommended circuit with higher requirements Element model MOV1 Recommended value S14K300 Element model FC-LX1D Recommended value 2KV/4KV EMC filter CY1 , CY2 1000pF/400VAC LDM 4.7μH/2A CX 0.1μF/275VAC 10mH, recommended to use MORNSUN’s FL2D-Z5-103 FUSE 2A/250V slow fusing, necessary LCM 3. For more information about Mornsun EMC Filter products, please visit www.mornsun-power.com to download the Selection Guide of EMC Filter 2015.08.24-B/3 Page 4 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH10 Series Dimensions and Recommended Layout LHXXA2 Dimensions 2015.08.24-B/3 Page 5 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH10 Series LHXXA3 Dimensions LHXXA4 Dimensions 2015.08.24-B/3 Page 6 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation AC/DC Converter LH10 Series Note: 1. Packing information please refer to Product Packing Information which can be downloaded from www.mornsun-power.com. Packing bag number of Horizontal package : 58220006, the Packing bag number of A2/A3/A4 package:58220010; 2. If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all parameters in the datasheet; 3. Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25 ℃, humidity<75% with nominal 4. 5. 6. 7. input voltage and rated output load; All index testing methods in this datasheet are based on our Company’s corporate standards; The performance parameters of the product models listed in this manual are as above, but some parameters of non-standard model products may exceed the requirements mentioned above. Please contact our technicians directly for specific information; We can provide product customization service; Specifications are subject to change without prior notice. Mornsun Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R. China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: [email protected] 2015.08.24-B/3 Page 7 of 7 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation