LINER LTC4255 Quad network power controller with ic compatible interface Datasheet

LTC4255
Quad Network Power
Controller with I2C Compatible Interface
U
FEATURES
■
■
■
■
■
■
■
■
DESCRIPTIO
Controls Four Independent –48V Power Channels
Each Channel has Separate Relay Drivers, ON/OFF
Control, Short-Circuit Protection with Current
Foldback, Open-Circuit Detection, and Power Good
Indication
Programmed via I2CTM Compatible Interface
Five Bit Programmable Digital Address Allows
Control of up to 32 LTC4255s (128 Channels)
Interrupt on FAULT Output can be used to Eliminate
Software Polling
Programmable Current Limit and Open-Circuit
Duration Periods
Programmable Latchoff or Autoretry after ShortCircuit Faults
Programmable Autoretry Duty Cycle
U
APPLICATIO S
■
The serial interface allows up to 128 channels to be
controlled with only two digital lines. A FAULT output can
be used as an interrupt line to eliminate fault detection by
software polling.
External switches and current sense resistors allow easy
scaling of current and power dissipation levels and provide the maximum protection against voltage and current
spikes.
The LTC4255 is available in the 28-pin SSOP package.
IP Phone Systems
DTE Power Distribution
, LTC and LT are registered trademarks of Linear Technology Corporation.
I2C is a trademark of Philips Electronics N.V.
U
■
The LTC®4255 is a quad –48V network power controller
with independent relay drivers and I2C compatible interface. Each channel can be turned on and off via software
control, while providing short-circuit protection, opencircuit detection, and power good indication. The shortcircuit protection includes a current foldback feature to
reduce power dissipation in the switch during shorts and
start-up.
TYPICAL APPLICATIO
12V
0.1µF
VCC
SCL
RELAY1
SDA
RELAY2
FAULT
LTC4255
AD0
AD1
AD2
RELAY3
AD3
RELAY4
AD4
DGND AGND
–48V
VEE
SENSE1 GATE1
OUT1 SENSE2 GATE2 OUT2 SENSE3 GATE3 OUT3 SENSE4 GATE4 OUT4
100k
RS1
0.1µF 0.33Ω
Q1
100k
100k
RS2
0.33Ω
Q2
RS3
0.33Ω
Q3
Q1, Q2, Q3, Q4: FDC3612
RELAYS: V23079 SERIES
100k
RS4
0.33Ω
4255 TA01
Q4
4255f
1
LTC4255
U
W W
W
ABSOLUTE
AXI U RATI GS
U
W
U
PACKAGE/ORDER I FOR ATIO
(Note 1)
Supply Voltages
VCC to DGND ....................................................... 18V
VEE to AGND ...................................................... –80V
DGND to AGND ................................................... ±5V
Digital Pin Voltages
SCL, SDA, FAULT ........................ DGND – 0.3V to 6V
AD0-4 ....................................... DGND – 0.3V to 5.5V
Relay Driver Output Voltage
RELAY1-4 (Note 5) ...... DGND –0.3V to DGND + 15V
Analog Voltages
SENSE1-4 ............................... VEE – 0.3V to VEE + 1V
OUT1-4 .................................. VEE – 80V to VEE + 80V
Operating Temperature Range
LTC4255C ............................................... 0°C to 70°C
Storage Temperature Range ................. – 65°C to 150°C
Lead Temperature (Soldering, 10 sec).................. 300°C
ORDER PART
NUMBER
TOP VIEW
FAULT
1
28 OUT1
SCL
2
27 GATE1
SDA
3
26 SENSE1
AD4
4
25 OUT2
AD3
5
24 GATE2
AD2
6
23 SENSE2
AD1
7
AD0
8
22 VEE
21 OUT3
RELAY1
9
20 GATE3
RELAY2 10
RELAY3 11
19 SENSE3
RELAY4 12
DGND 13
17 GATE4
VCC 14
15 AGND
LTC4255CG
18 OUT4
16 SENSE4
G PACKAGE
28-LEAD PLASTIC SSOP
TJMAX = 125°C, θJA = 90°C/W
Consult LTC Marketing for parts specified with wider operating temperature ranges.
ELECTRICAL CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = 12V, VEE = –48V, AGND = DGND = 0V (Note 2)
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
10.8
12
13.2
V
DC Characteristics
VCC
Positive Supply Voltage
VCC Referenced to DGND
ICC
Positive Supply Current
Relays Off
All Relays On
2.1
10
3
15
mA
mA
VEE
Negative Supply Voltage
VEE Referenced to AGND
–48
–72
V
IEE
Negative Supply Current
–1.9
–3
mA
∆VGND
DC Ground Difference
5
V
VLKO
VEE Undervoltage Lockout
∆VGATE
External Gate Voltage (VGATE – VEE)
IGATE = –1µA
10
13
15
V
IGATE
GATE Pin Output Current
GATE On, VGATE = VEE
GATE Off, VGATE = VEE + 5V
–30
30
–50
50
–70
80
µA
µA
VSC
Short-Circuit Sense Voltage
(VSENSE – VEE), VOUT – VEE = 0V
●
125
150
170
mV
VOC
Open-Circuit Sense Voltage
(VSENSE – VEE)
●
1
3
4.5
mV
VPG
Power_OK Threshold Voltage
(VOUT – VEE)
●
1
2
3
IOUT
OUT Pin Current
VOUT = VEE
VOLR
Relay Driver Output Low Voltage
(VRELAY – DGND), IRELAY = 50mA, RELAY On
VCLAMPR
Relay Driver Clamp Voltage
(VRELAY – DGND), IRELAY = 50mA,
RELAY Off (Note 5)
VOLD
Digital Output Low Voltage
SDA, FAULT, I = 3mA
AGND – DGND (Note 3)
–5
–27
V
µA
–1.4
18
●
V
0.3
V
24
V
0.4
V
4255f
2
LTC4255
ELECTRICAL CHARACTERISTICS
The ● denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VCC = 12V, VEE = –48V, AGND = DGND = 0V
SYMBOL
PARAMETER
CONDITIONS
MIN
VILD
Digital Input Low Voltage
SCL, SDA
●
VIHD
Digital Input High Voltage
SCL, SDA
●
RPU
AD0 to AD4 Pullup Resistors to 5V
TYP
MAX
UNITS
0.8
V
2.4
V
30
50
90
kΩ
AC Characteristics
tCL
Current Limit Filter Time
B5 = 0, B4 = 0, Figure 2
B5 = 0, B4 = 1
B5 = 1, B4 = 0
B5 = 1, B4 = 1
●
●
●
●
4.8
9.6
19.2
76.8
6
12
24
96
7.2
14.4
28.8
115.2
ms
ms
ms
ms
tOCD
Open-Circuit Enable Delay
After Power_OK
B7 = 0, B6 = 0
B7 = 0, B6 = 1
B7 = 1, B6 = 0
B7 = 1, B6 = 1
●
●
●
●
50
104
213
433
62
130
267
541
74
156
320
649
ms
ms
ms
ms
tOCF
Open-Circuit Filter Time
Figure 3
●
9.6
18
28.8
ms
tOD
Turn-On Delay Time
Figure 4
●
9.6
18
28.8
ms
DCR
Retry Duty Cycle
B3 = 0
B3 = 1
●
●
0.78
5.5
0.83
6
0.89
6.7
%
%
tSCLK
Clock Frequency
(Note 3)
●
400
kHz
t1
Bus Free Time
Figure 1 (Notes 3, 4)
●
1.3
µs
t2
Start Hold Time
Figure 1 (Notes 3, 4)
●
600
ns
t3
SCL Low Time
Figure 1 (Notes 3, 4)
●
1.3
µs
t4
SCL High Time
Figure 1 (Notes 3, 4)
●
600
ns
t5
Data Hold Time
Figure 1 (Notes 3, 4)
●
150
ns
t6
Data Setup Time
Figure 1 (Notes 3, 4)
●
200
ns
t7
Start Setup Time
Figure 1 (Notes 3, 4)
●
600
ns
t8
Stop Setup Time
Figure 1 (Notes 3, 4)
●
600
ns
t9
Stop to Fault Clear
Figure 1 (Notes 3, 4)
●
300
ns
tr
SCL, SDA Rise Time
Figure 1 (Notes 3, 4)
●
20
300
ns
tf
SCL, SDA Fall Time
Figure 1 (Notes 3, 4)
●
20
150
ns
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: All currents into device pins are positive; all currents out of device
pins are negative. All voltages are referenced to ground unless otherwise
specified.
Note 3: Guaranteed by design, not subject to test.
Note 4: Values referred to VILD and VIHD.
Note 5: A Zener diode clamps the relay drivers at 18V (RELAY 1-4).
4255f
3
LTC4255
U W
TYPICAL PERFOR A CE CHARACTERISTICS
ICC vs VCC (Relays Off)
1.290
ICC vs VCC (Relays On)
9.8
TA = 25°C
ICC vs Temperature (Relays Off)
1.34
TA = 25°C
1.280
1.30
ICC (mA)
ICC (mA)
1.260
ICC (mA)
9.4
1.270
VCC = 12V
1.32
9.6
9.2
1.28
1.26
9.0
1.24
1.250
8.8
1.240
10.8
11.3
12.3
11.8
VCC (V)
12.8
1.22
8.6
10.8
13.3
11.3
11.8
12.3
VCC (V)
12.8
–25
0
25
50
TEMPERATURE (°C)
75
4255 G02
4255 G01
ICC vs Temperature (Relays On)
9.6
1.20
–50
13.3
4255 G03
IEE vs VEE
0
VCC = 12V
100
IEE vs Temperature
–1.88
VEE = –48V
TA = 25°C
9.5
–1.90
–0.8
–1.92
IEE (mA)
ICC (mA)
9.3
–0.4
IEE (mA)
9.4
9.2
–1.2
–1.94
–1.6
–1.96
9.1
9.0
8.9
8.8
–50
–25
0
25
50
TEMPERATURE (°C)
75
100
–2.0
–80
–60
–40
VEE (V)
–20
0
–1.98
–50
0
25
50
TEMPERATURE (°C)
75
VSC vs VOUT
VSC vs Temperature
165
TA = 25°C
140
100
4255 G06
4255 G05
4255 G04
160
–25
VOC vs Temperature
3.20
VOUT = VEE
160
3.15
155
3.10
80
60
VOC (mV)
100
VSC (mV)
VSC (mV)
120
150
3.05
145
3.00
140
2.95
40
20
0
–50
–40
–20
–30
VOUT (V)
–10
0
4255 G07
135
–50
–25
0
25
50
TEMPERATURE (°C)
75
100
4255 G08
2.90
–50
–25
25
50
0
TEMPERATURE (°C)
75
100
4255 G09
4255f
4
LTC4255
U W
TYPICAL PERFOR A CE CHARACTERISTICS
IOUT vs VOUT
IOUT vs Temperature
2.0
0
–0.2
IGATE vs Temperature
–44
VOUT = VEE
–46
1.8
–48
–0.8
–1.0
IGATE (µA)
1.6
–0.6
IOUT (µA)
IOUT (µA)
–0.4
1.4
1.2
1.0
–1.6
–50
TA = 25°C
VEE = –48V
–40
–20
–30
VOUT (V)
–10
–25
0
25
50
TEMPERATURE (°C)
75
IGATE vs Temperature
GATE OFF
VGATE = VEE + 5V
13.6
13.4
–43
75
100
VSENSE = VEE
–44
ISENSE (µA)
VGATE (V)
IGATE (µA)
50
25
0
TEMPERATURE (°C)
ISENSE vs Temperature
–42
13.2
55
50
–25
4255 G12
VGATE vs Temperature
65
13.0
12.8
–45
–46
45
12.6
40
–47
12.4
35
–50
–25
0
25
50
TEMPERATURE (°C)
75
12.2
–50
100
–25
50
25
0
TEMPERATURE (°C)
–48
–50
100
75
4255 G13
0
25
50
TEMPERATURE (°C)
0.170
100
AD0-4 Pullup Resistors to 5V (RPU)
vs Temperature
60
IRELAY = 50mA
59
0.165
–27
75
4255 G15
Relay Driver Output Low Voltage
(VOLR) vs Temperature
–26
58
0.160
57
–28
RPU (kΩ)
VOL (V)
0.155
–29
0.150
0.145
–30
–31
–32
–50
–25
4255 G14
VEE Undervoltage Lockout
vs Temperature
VEE UNDERVOLTAGE LOCKOUT (V)
–58
–50
100
4255 G11
4255 G10
60
–52
–56
0.8
–50
0
–50
–54
–1.2
–1.4
GATE ON
VGATE = VEE
–25
0
25
50
TEMPERATURE (°C)
75
100
4255 G16
56
55
54
0.140
53
0.135
52
0.130
–50
–25
25
50
0
TEMPERATURE (°C)
75
100
4255 G17
51
–50
50
0
TEMPERATURE (°C)
100
4255 G18
4255f
5
LTC4255
U
U
U
PI FU CTIO S
FAULT (Pin 1): Open-Drain FAULT Output. Pulls low when
a short-circuit or open circuit fault occurs. The signal can
be used to generate a fault condition interrupt to the host
controller eliminating the need for continuous software
polling.
SCL (Pin 2): Serial Interface Clock Input. It requires a
resistor or current source that pulls up to a supply that is
less than 6V.
SDA (Pin 3): Serial Interface Data Input and Output. It
requires a resistor or current source that pulls up to a
supply that is less than 6V.
AD0-4 (Pins 4,5,6,7,8): Serial Interface Address Inputs.
Connect to DGND for a low, float or connect to 3.3V or 5V
supply for a high.
RELAY1-4 (Pins 9,10,11,12): Relay Driver Outputs. Open
collector capable of sinking 50mA to within 0.3V of DGND.
An internal 18V clamp to DGND will protect the part when
the relay is turned off.
DGND (Pin 13): Digital Ground. Return for digital logic and
relay drivers. Must be within ±5V of AGND.
VCC (Pin 14): 12V Supply Input. Powers the digital section
and relay drivers. Bypass with a 0.1µF capacitor to DGND.
AGND (Pin 15): Analog Ground.
SENSE1-4 (Pins 16,19,23,26): Current Sense Inputs.
Monitors the FET current with a sense resistor placed
between SENSE and VEE. When the voltage across the
sense resistor reaches the short-circuit sense voltage, the
GATE pin voltage will be lowered to maintain a constant
current in the FET. At the same time, the current limit timer
will be started. If the short-circuit condition persists for the
duration of the current limit timer period, the FET will be
turned off. The short-circuit sense voltage is lowered to
reduce the FET power dissipation when the voltage at the
associated OUT pin is within 18V of AGND.
If the open-circuit enable bit is set and the voltage across
the sense resister remains below the open-circuit sense
voltage for longer than tOCF, the open-circuit filter time,
then the FET will be turned off.
GATE1-4 (Pins 17,20,24,27): Gate Drive Outputs. When
the FET is turned on, a 50µA pull-up current source is
connected to the pin. The gate voltage is clamped to
13V(typ) above VEE. During a short-circuit condition, the
GATE pin voltage will be driven to a lower voltage to
maintain a constant current in the FET.
OUT1-4 (Pins 18,21,25,28): Output Voltage Monitor Inputs. A current limit foldback feature limits the power
dissipation in the FET by reducing the short-circuit current
when the voltage at the OUT pin is between AGND and
AGND – 18V. The Power_OK bit is set when the voltage
from OUT to VEE is less than about 2V.
VEE (Pin 22): –48V Supply Input.
4255f
6
LTC4255
U
U
REGISTER DEFI ITIO S
Register 1: Control Register ( Write Only)
A0: Switch 1 Enable. Logic high turns on Port 1 switch,
logic low turns off the Port 1 switch.
A1: Switch 2 Enable. Logic high turns on Port 2 switch,
logic low turns off Port 2 switch.
A2: Switch 3 Enable. Logic high turns on Port 3 switch,
logic low turns off Port 3 switch.
A3: Switch 4 Enable. Logic high turns on Port 4 switch,
logic low turns off Port 4 switch.
A4: Relay 1 Enable. Logic high turns on Port 1 relay, logic
low turns off Port 1 relay.
A5: Relay 2 Enable. Logic high turns on Port 2 relay, logic
low turns off Port 2 relay.
A6: Relay 3 Enable. Logic high turns on Port 3 relay, logic
low turns off Port 3 relay.
A7: Relay 4 Enable. Logic high turns on Port 4 relay, logic
low turns off Port 4 relay.
The default setting is all bits set low.
Register 2: Setup Register (Write Only)
B0: Fault Clear Bit. Logic high clears any fault bits that are
set.
B1: Autoretry Enable Bit. Logic high enables autoretry
following short-circuit faults. Logic low disables autoretry.
B2: Open-Circuit Detect Enable Bit. Logic high enables and
logic low disables open-circuit fault detection.
B3: Retry Duty Cycle Select Bit. Logic high sets the
autoretry duty cycle to 6%. Logic low sets the autoretry
duty cycle to 0.83%. When autoretry is not enabled (B1 =
low), the switch turn-on after A0 to A3 are set to high will
be delayed to enforce the selected retry duty cycle.
B4: Current Limit Timer Select Bit 0. The current limit
timer select bits configure tCL, the time a current limit must
be sustained before a short-circuit fault occurs. (See tCL in
AC Characteristics.)
B5: Current Limit Timer Select Bit 1. The current limit
timer select bits configure tCL, the time a current limit must
be sustained before a short-circuit fault occurs. (See tCL in
AC Characteristics.)
B6: Open-Circuit Enable Delay Timer Select Bit␣ 0. The
open-circuit enable delay timer select bits configure tOCD,
the time following a Power_OK condition when no opencircuit faults will be generated. ( See tOCD, in AC Characteristics.)
B7: Open-Circuit Enable Delay Timer Select Bit␣ 1. The
open-circuit enable delay timer select bits configure tOCD,
the time following a Power_OK condition when no opencircuit faults will be generated. ( See tOCD, in AC Characteristics.)
The default setting is all bits set low.
Register 3: Status Register 1 (Read Only)
C0: Power_OK for Port 1. Logic high indicates switch 1
is on.
C1: Power_OK for Port 2. Logic high indicates switch 2
is on.
C2: Power_OK for Port 3. Logic high indicates switch 3
is on.
C3: Power_OK for Port 4. Logic high indicates switch 4
is on.
C4: Reserved. Logic high.
C5: Reserved. Logic low.
C6: Reserved. Logic low.
C7: Reserved. Logic low.
4255f
7
LTC4255
U
U
REGISTER DEFI ITIO S
Register 4: Status Register 2 (Read Only)
D4: Open-Circuit Fault Status for Port 1. Logic high
indicates an open-circuit has been detected on Port 1.
D0: Current Limit Fault Status for Port 1. Logic high
indicates a short-circuit has been detected on Port 1.
D5: Open-Circuit Fault Status for Port 2. Logic high
indicates an open-circuit has been detected on Port 2.
D1: Current Limit Fault Status for Port 2. Logic high
indicates a short-circuit has been detected on Port 2.
D6: Open-Circuit Fault Status for Port 3. Logic high
indicates an open-circuit has been detected on Port 3.
D2: Current Limit Fault Status for Port 3. Logic high
indicates a short-circuit has been detected on Port 3.
D7: Open-Circuit Fault Status for Port 4. Logic high
indicates an open-circuit has been detected on Port 4.
D3: Current Limit Fault Status for Port 4. Logic high
indicates a short-circuit has been detected on Port 4.
U UU
TEST TI I G
t3
tr
t4
tf
SCL
t5
t2
t6
t7
t8
SDA
t1
t9
FAULT
4255 F01
Figure 1. 2-Wire Interface Timing
VSC
0V
VOC
VSENSE TO VEE
VSENSE TO VEE
0V
tCL
FAULT
FAULT
tOCF
4255 F02
Figure 2. Current Limit Timing
4255 F03
Figure 3. Open-Circuit Filter Timing
SCL
SDA
AO
ACK
STOP BIT
GATE
tOD
4255 F04
Figure 4. Turn-On Delay
4255f
8
LTC4255
W
UW
TI I G DIAGRA S
SCL
SDA
0
1
AD4 AD3 AD2 AD1 AD0 R/W ACK A7
START BY
MASTER
A6
A5
A4
A3
A2
ACK BY
SLAVE
FRAME 1
SERIAL BUS ADDRESS BYTE
A0 ACK B7
A1
B6
B5
B4
B3
B2
B1
ACK
B0
STOP BY MASTER. INTERNAL
DATA LATCHES UPDATED
FRAME 3
SETUP BYTE
ACK BY
SLAVE
FRAME 2
CONTROL BYTE
4255 F05
Figure 5. Writing to the Control and Setup Registers
SCL
SDA
0
1
AD4 AD3 AD2 AD1 AD0 R/W ACK A7
START BY
MASTER
A6
A5
A4
A3
A2
ACK BY
SLAVE
FRAME 1
SERIAL BUS ADDRESS BYTE
A1
A0
ACK
STOP BY MASTER. INTERNAL
DATA LATCHES UPDATED
ACK BY
SLAVE
FRAME 2
CONTROL BYTE
4255 F06
Figure 6. Writing to the Control Register Only
SCL
SDA
0
1
AD4 AD3 AD2 AD1 AD0 R/W ACK A7
START BY
MASTER
A6
A5
A4
A3
A2
ACK BY
SLAVE
A1
A0 ACK B7
ACK BY
SLAVE
B6
B5
B4
B3
B2
B1
B0
ACK
STOP BY MASTER. INTERNAL
DATA LATCHES UPDATED
FAULT
FRAME 1
SERIAL BUS ADDRESS BYTE
FRAME 2
CONTROL BYTE
FRAME 3
SETUP BYTE
4255 F07
Figure 7. Clearing the FAULT Signal
4255f
9
LTC4255
W
UW
TI I G DIAGRA S
SCL
SDA
0
1
AD4 AD3 AD2 AD1 AD0 R/W ACK C7
START BY
MASTER
C6
C5
C4
C3
C2
ACK BY
SLAVE
FRAME 1
SERIAL BUS ADDRESS BYTE
C1
C0 ACK D7
D6
D5
D4
D3
D2
D1
D0 ACK
NO ACK BY
MASTER
ACK BY
MASTER
FRAME 2
STATUS BYTE #1
FRAME 3
STATUS BYTE #2
STOP BY
MASTER
4255 F08a
Figure 8a. Reading Both Status Registers
SCL
SDA
0
1
AD4 AD3 AD2 AD1 AD0 R/W ACK C7
START BY
MASTER
C6
C5
C4
C3
C2
ACK BY
SLAVE
FRAME 1
SERIAL BUS ADDRESS BYTE
C1
C0 ACK
ACK BY
MASTER
FRAME 2
STATUS BYTE#1
STOP BY
MASTER
4255 F08b
Figure 8b. Reading Status Register #1 Only
4255f
10
LTC4255
U
U
W
U
APPLICATIO S I FOR ATIO
Normal Power-Up
Using channel 1 as an example, a normal power-up cycle
begins when the switch 1 enable bit (A0) and relay 1 enable
bit (A4) are set high and then latched into the chip by a
STOP bit on the serial interface (point A, Figure 9).
The RELAY1 output turns on immediately and energizes
an optional relay connecting the AGND and OUT1 pins to
the cable. After a fixed delay of approximately 18ms (tOD),
the GATE1 pin will start to pull high (point B). When the
threshold voltage of the FET is reached, current will begin
flowing in the external FET (point C). The voltage at the
OUT1 pin will then fall at a rate determined by the current
limit and the output load capacitance. Because the current
limit is lower when the OUT1 pin is near AGND due to the
foldback circuit, the voltage will fall slowly at first, then get
faster. At the same time, the current limit timer will start.
The OUT1 voltage must reach its final value and the analog
current limit circuit must turn off before the current limit
timer expires, or a current limit fault will be detected and
the FAULT pin will be pulled low.
When the voltage at OUT1 is within 2V of VEE, the Power_OK
(C0) bit will be set (point D) and the open-circuit enable
delay timer started. As long as the load current turns on
before the open-circuit enable delay timer expires, the
FAULT pin will remain in a high impedance state and the
current limit fault status bit (D0) and open-circuit fault
status bit (D4) bits will remain low, thus completing a
normal power-up sequence. The Power_OK bit will remain high until the switch is turned off by setting the
switch enable bit (AO) low or a short-circuit or opencircuit condition turns off the switch.
A normal power-down sequence begins when the switch
enable bit (A0) and relay enable bit (A4) are cleared and
then latched into the chip by a STOP bit on the serial
interface (point E). The RELAY1 pin will go into a high
impedance state and the inductive voltage spike from the
primary coil will be clamped at about 18V. The relay will
typically disengage several milliseconds later. At the same
time, the GATE1 pin will be pulled low by a 50µA current
source, the FET will turn off, and the Power_OK bit will be
cleared.
SCL
SDA
AO
ACK
AO
ACK
STOP BIT
SHORT-CIRCUIT STATUS
(D0)
OPEN-CIRCUIT STATUS
(D4)
POWER_OK
(C0)
FAULT
RELAY1
FET TURNS ON
GATE1
POWER OK
OUT1
A
B
C
D
E
tOD
4255 F09
Figure 9. Normal Power-Up and Power-Down Sequence on Channel 1
4255f
11
LTC4255
U
U
W
U
APPLICATIO S I FOR ATIO
Power-Up with No Load
open-circuit fault status bit (D4) will be set (point E). The
FAULT pin will pull low to generate an interrupt to the
processor which can then read the status register to
determine which channel faulted.
When a channel powers-up with no load, the initial
sequence is the same as the normal case. When the VOUT1
voltage is within the power good threshold, the Power_OK
bit is set (point D, Figure 10) and the open-circuit enable
delay timer started. The duration of the timer can be
programmed via bits B6-B7.
When the fault clear bit (B0) is set during a write cycle via
the 2-wire interface (point F), the FAULT pin goes into a
high impendance state, the open-circuit fault status bit
(D4) is cleared, and the channel is allowed to turn back on
if the relay 1 enable (A4) and switch 1 (AO) enable bits are
set (point G.)
When the open-circuit enable timer expires (tOCD, point E),
the open-circuit detector is enabled if the global opencircuit detect enable bit (B2) has been set. When the
voltage across the sense resistor is less than 3mV(typ) for
at least 18ms (tOCF), the FET will be turned off, and the
The channel is always turned off after an open-circuit fault
detection and not allowed to automatically restart.
SCL
SDA
AO
ACK
BO
ACK
STOP BIT
SHORT-CIRCUIT STATUS
(D0)
OPEN-CIRCUIT STATUS
(D4)
POWER_OK
(C0)
FAULT
FAULT CLEARED
RELAY1
FET TURNS ON
OPEN CIRCUIT
DETECTED
GATE1
OPEN CIRCUIT
TIMER EXPIRES
OUT1
POWER OK
POWER OK
A
B
tOD
C
D
E
tOCD
F
G
H
4255 F10
Figure 10. Power-Up Sequence with No Load on Channel 1
4255f
12
LTC4255
U
U
W
U
APPLICATIO S I FOR ATIO
Power-Up into a Short-Circuit
When a channel powers-up with a shorted load, the
RELAY1 pin will pull low immediately and the GATE1 pin
will start to pull high (point B Figure 11) after a turn-on
delay (tOD). When the FET turns on at point C, the current
will reach a constant value and the programmable current
limit timer (tCL) will start. The current limit timer is
programmed via bits B4 to B5. When the current limit
timer expires, the GATE1 and FAULT pins will pull low, the
current limit fault status bit (D0) will be set, and the retry
timer (tR) started (point D).
If the autoretry enable bit (B1) is not set, the channel will
remain off until the fault is cleared by setting the fault clear
bit (B0) and the channel is turned back on by setting the
switch enable bit (A0) and the relay enable bit (A4)
(point␣ F). If the fault clear bit (B0) is set before the retry
timer expires (point E) the channel turn-on will be delayed
until the timer expires to enforce the maximum retry duty
cycle (DCR). This duty cycle is programmable via bit B3
and sets the maximum ratio of the FET on-time to off-time
under a short-circuit condition.
DC R =
tCL
tCL + tR
SCL
SDA
AO
ACK
BO
ACK
STOP BIT
STOP BIT
SHORT-CIRCUIT STATUS
(D0)
OPEN-CIRCUIT STATUS
(D4)
POWER_OK
(C0)
FAULT
FAULT CLEARED
RELAY1
FET
TURNS ON
CL TIMER
EXPIRES CHANNEL
LATCHES OFF
GATE1
OUT1
FET
CURRENT
A
B
tOD
C
D
tCL
E
F
G
H
tR
I
4255 F11
Figure 11. Power-Up Sequence with Shorted Load on Channel 1 with Autoretry Disabled
4255f
13
LTC4255
U
U
W
U
APPLICATIO S I FOR ATIO
If the autoretry enable bit (B1) is set, then the channel will
automatically restart after the retry delay timer expires
(Figure 12, point E). If the channel successfully powers up
after an autoretry, the Power_OK bit (CO) will be set.
However, FAULT will continue to pull down and the shortcircuit bit (DO) will remain high until the fault is cleared by
setting the FAULT clear bit (BO).
Schottky diodes should be added between the drains of
the FETs and AGND using a layout that minimizes the
trace lengths between the parts.
Address Selection
The lower 5 bits of the serial interface address can be set
by the address selection pins AD0 to AD4 with AD0 being
the least significant bit. The upper two bits are preset to
AD5 = high and AD6 = low. To force an address bit to low,
the address selection pin should be connected to DGND.
To force an address bit to high, the address selection pin
can be left floating and an internal pull-up resistor will pull
the pin up to the internal digital supply voltage (typically
5V). If more noise immunity is needed, the pin can be
connected directly to a 5V or 3.3V external supply.
In the case of a short-circuit occuring after a normal
power-up, high rates of change of current (high di/dt)
through the inductance of the cable or even the traces on
the PCB can cause the voltages at OUT1-4 to overshoot.
A 100kΩ resistor should be placed between the drains of
the FETs and the OUT1-4 pins to limit the energy absorbed
by the LTC4255 if the drains of the FETs exceed OUT1-4’s
absolute maximum voltage rating. Also, if the FETs are
not capable of safely absorbing this energy, high-speed
SCL
SDA
AO
ACK
BO
ACK
STOP BIT
STOP BIT
SHORT-CIRCUIT STATUS
(D0)
OPEN-CIRCUIT STATUS
(D4)
POWER_OK
(C0)
FAULT
FAULT CLEARED
RELAY1
GATE1
FET
TURNS ON
CL TIMER
EXPIRES
CL TIMER
EXPIRES
AUTO-RESTART
INITIATED
OUT1
FET
CURRENT
A
B
tOD
C
D
tCL
E
F
G
H
tR
4255 F12
Figure 12. Power-Up Sequence with Shorted Load on Channel 1 with Autoretry Enabled
4255f
14
LTC4255
U
W
U
U
APPLICATIO S I FOR ATIO
Relay Drivers
The four relay drivers have an open collector NPN
transistor with the ability to sink 50mA to within 0.3V of
DGND (Figure 13).
An 18V Zener diode connected to DGND is provided to
protect against the inductive kickback of the coil when the
NPN transistor is turned off.
3V TO 12V
DRIVE
CIRCUITRY
RELAY
18V
DGND
4255 F13
Figure 13. Relay Driver Output
U
PACKAGE DESCRIPTIO
G Package
28-Lead Plastic SSOP (5.3mm)
(Reference LTC DWG # 05-08-1640)
9.90 – 10.50*
(.390 – .413)
1.25 ±0.12
7.8 – 8.2
28 27 26 25 24 23 22 21 20 19 18 17 16 15
5.3 – 5.7
0.42 ±0.03
7.40 – 8.20
(.291 – .323)
0.65 BSC
1 2 3 4 5 6 7 8 9 10 11 12 13 14
RECOMMENDED SOLDER PAD LAYOUT
5.00 – 5.60**
(.197 – .221)
2.0
(.079)
0° – 8°
0.09 – 0.25
(.0035 – .010)
0.55 – 0.95
(.022 – .037)
NOTE:
1. CONTROLLING DIMENSION: MILLIMETERS
MILLIMETERS
2. DIMENSIONS ARE IN
(INCHES)
0.65
(.0256)
BSC
0.22 – 0.38
(.009 – .015)
0.05
(.002)
G28 SSOP 0802
3. DRAWING NOT TO SCALE
*DIMENSIONS DO NOT INCLUDE MOLD FLASH. MOLD FLASH
SHALL NOT EXCEED .152mm (.006") PER SIDE
**DIMENSIONS DO NOT INCLUDE INTERLEAD FLASH. INTERLEAD
FLASH SHALL NOT EXCEED .254mm (.010") PER SIDE
4255f
Information furnished by Linear Technology Corporation is believed to be accurate and reliable.
However, no responsibility is assumed for its use. Linear Technology Corporation makes no representation that the interconnection of its circuits as described herein will not infringe on existing patent rights.
15
LTC4255
U
TYPICAL APPLICATIO
Typical Application Using Schottky Diodes to Protect FETs
12V
0.1µF
VCC
SCL
RELAY1
SDA
RELAY2
FAULT
LTC4255
AD0
AD1
AD2
AD3
RELAY3
AD4
RELAY4
DGND AGND
VEE
SENSE1 GATE1
100k
RS1
0.1µF 0.33Ω
–48V
OUT1 SENSE2 GATE2 OUT2 SENSE3 GATE3 OUT3 SENSE4 GATE4 OUT4
100k
100k
100k
Q1
RS2
0.33Ω
Q2
RS3
0.33Ω
Q3
4255 TA01
RS4
0.33Ω
Q1, Q2, Q3, Q4: FDC3612 (FAIRCHILD)
SCHOTTKY DIODES: MBRS1100T3 (ON SEMI)
RELAYS: V23079 SERIES (TYCO/POTTER AND BRUMFIELD)
Q4
RELATED PARTS
PART NUMBER
DESCRIPTION
COMMENTS
LTC1694
I2C/SMBus Accelerator
Active Pull-Up Improves Rise Time, Ensures Data Integrity
LT4250
Negative Voltage Hot Swap Controller in SO-8
Active Current Limiting, Supplies from –20V to –80V
LTC4251
Negative Voltage Hot Swap Controller in SOT-23
Active Current Limiting, Floating Supplies from –15V
LTC4300-1/LTC4300-2 Hot Swappable 2-Wire Bus Buffer
Isolates SDA, SCL Lines from Output/Allows 3.3V to 5V Level Translation
4255f
16
Linear Technology Corporation
LT/TP 0203 2K • PRINTED IN USA
1630 McCarthy Blvd., Milpitas, CA 95035-7417
(408) 432-1900
●
FAX: (408) 434-0507 ● www.linear.com
 LINEAR TECHNOLOGY CORPORATION 2002
Similar pages