DB Lectro JMX-94FBZ40DC12V Well anti-shock and anti-vibration Datasheet

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
JMX-94F
NHG RELAYS
JMX-94F
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Creepage distance
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
03001003499
39 30 17.5
Features
Magnet latching relay.
Small size, light weight.
High sensitivity & reliability.
Well anti-shock and anti-vibration.
Heavy contact load.
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1500V
50Hz 4000V
8.4mm
Functional 100m/s2;Survival:1000 m/s2 11ms
10~55Hz Double amplitude 1.5mm
5N
235
2
3 0.5s
-25~70
85% (at 40 )
33g
Item 6 of IEC255-5
Item 6 of IEC255-5
Addenda B of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Ordering Information
JMX-94F
A
Z 60
1
2
3
DC12V
4
Safety approval
CQC
Load
80A/220VAC
5
1 Part number JMX-94F
2 Contact arrangement A:1A B:1B
3 Enclosure S: Sealed type Z: Dust cover
4 Contact current 40:40A 60:60A 80:80A
5 Coil rated voltage(V) DC: 9,12, 24
6 Coil NIL:Singal coil:D: Double coils
Dimensions
mm /inch
39 Max.
0.535max.
Dash
numbers
Coil
rated
voltage
VDC
Coil
resistance
10%
Switching
voltage
VDC
(50%-70% of
rated voltage)
Pulse
magnitude
ms
Coil
power
consumption
W
Operate
Time
ms
Reset
Time
ms
2.5
0.098
9
81
4.5~6.3
012-1000
12
144
6.0~8.4
024-1000
24
576
12.0~16.8
009-2000
9
012-2000
12
024-2000
24
60
1
20
20
21.59
0.850
+
5.08
0.200
3-1X0.4 (3-0.6X0.6)
0.039 0.016 0.024 0.024
+
-
-
+
Wiring diagram
Dimensions
009-1000
2.5
0.098
25.4
1.000
0.024(0.039)
2.5
0.6 (1.0)
25.6
3.5
Coil Parameter
5.08
0.200
0.689max.
Item 3.31 of IEC255-7
10
2.8
0.110
Mounting (Bottom view)
17.5 Max.
6
4- 1.2
0.047
20
0.787
0.433
Item 3.30 of IEC255-7
19.08
0.751
5.08
0.200
12
0.472
11
104
0.433(0.394)
Electrical
(Rated load)
Mechanical
(No load)
Operation life
0.354
0.335
0.6
0.024
(assistance mounting terminal)
3- 1.2
0.047
2.8
0.110
9
8.5
11 (10)
Contact Resistance & Voltage drop
1.008
1A SPSTNO , 1B SPSTNC
AgCd O
80A/250VAC
60A/250VAC
40A/250VAC
20000VA
15000VA
10000VA
300VAC
Max. Switching Current:80A
50m (at 1A/24VDC)
Item 3.12 of IEC255-7
100mV (at rated load)
Item 3.12 of IEC255-7
0.138
Contact Arrangement
Contact Material
Contact Rating(resistive)
Max. Switching Power
Max. Switching Voltage
30 Max.
1.181max.
Contact Data
0.098
1.102
19.08
0.751
25.4
1.000
(assistance mounting terminal)
5.5
0.217
28
NOTES: 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
3).Relays shall have plus(+) signs placed on the circuit diagram as shown.
Reference Data
4.5~6.3
2
40.5
2
72
6.0~8.4
288
12.0~16.8
2
60
2
20
20
CAUTION: 1.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to
be in the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
Ningbo Forward Relay Corporation LTD.
174
JMX-94F
JMX-94F
Operation condition
Insulation Resistance
Dielectric Strength
Between contacts
Between contact and coil
Creepage distance
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
03001003499
39 30 17.5
Features
Magnet latching relay.
Small size, light weight.
High sensitivity & reliability.
Well anti-shock and anti-vibration.
Heavy contact load.
1000M
min (at 500VDC)
Item 7 of IEC255-5
50Hz 1500V
50Hz 4000V
8.4mm
Functional 100m/s2;Survival:1000 m/s2 11ms
10~55Hz Double amplitude 1.5mm
5N
235
2
3 0.5s
-25~70
85% (at 40 )
33g
Item 6 of IEC255-5
Item 6 of IEC255-5
Addenda B of IEC255-5
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Ordering Information
JMX-94F
A
Z 60
1
2
3
DC12V
4
Safety approval
CQC
Load
80A/220VAC
5
1 Part number JMX-94F
2 Contact arrangement A:1A B:1B
3 Enclosure S: Sealed type Z: Dust cover
4 Contact current 40:40A 60:60A 80:80A
5 Coil rated voltage(V) DC: 9,12, 24
6 Coil NIL:Singal coil:D: Double coils
Dimensions
mm /inch
39 Max.
0.535max.
Dash
numbers
Coil
rated
voltage
VDC
Coil
resistance
10%
Switching
voltage
VDC
(50%-70% of
rated voltage)
Pulse
magnitude
ms
Coil
power
consumption
W
Operate
Time
ms
Reset
Time
ms
2.5
0.098
9
81
4.5~6.3
012-1000
12
144
6.0~8.4
024-1000
24
576
12.0~16.8
009-2000
9
012-2000
12
024-2000
24
60
1
20
20
21.59
0.850
+
5.08
0.200
3-1X0.4 (3-0.6X0.6)
0.039 0.016 0.024 0.024
+
-
-
+
Wiring diagram
Dimensions
009-1000
2.5
0.098
25.4
1.000
0.024(0.039)
2.5
0.6 (1.0)
25.6
3.5
Coil Parameter
5.08
0.200
0.689max.
Item 3.31 of IEC255-7
10
2.8
0.110
Mounting (Bottom view)
17.5 Max.
6
4- 1.2
0.047
20
0.787
0.433
Item 3.30 of IEC255-7
19.08
0.751
5.08
0.200
12
0.472
11
104
0.433(0.394)
Electrical
(Rated load)
Mechanical
(No load)
Operation life
0.354
0.335
0.6
0.024
(assistance mounting terminal)
3- 1.2
0.047
2.8
0.110
9
8.5
11 (10)
Contact Resistance & Voltage drop
1.008
1A SPSTNO , 1B SPSTNC
AgCd O
80A/250VAC
60A/250VAC
40A/250VAC
20000VA
15000VA
10000VA
300VAC
Max. Switching Current:80A
50m (at 1A/24VDC)
Item 3.12 of IEC255-7
100mV (at rated load)
Item 3.12 of IEC255-7
0.138
Contact Arrangement
Contact Material
Contact Rating(resistive)
Max. Switching Power
Max. Switching Voltage
30 Max.
1.181max.
Contact Data
0.098
1.102
19.08
0.751
25.4
1.000
(assistance mounting terminal)
5.5
0.217
28
NOTES: 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
3).Relays shall have plus(+) signs placed on the circuit diagram as shown.
Reference Data
4.5~6.3
2
40.5
2
72
6.0~8.4
288
12.0~16.8
2
60
2
20
20
CAUTION: 1.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to
be in the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.
173
Ningbo Huaguan Relay Corporation LTD.
Similar pages