HITRON HVP400-S050700 Universal input harmonic correction ac-dc n1 redundancy and active current sharing enclosure box single & multi-output 400 watts internal switching Datasheet

H HiTRON
UNIVERSAL INPUT HARMONIC CORRECTION
AC-DC N+1 REDUNDANCY AND ACTIVE CURRENT SHARING
ENCLOSURE BOX SINGLE & MULTI-OUTPUT 400 WATTS
INTERNAL SWITCHING POWER SUPPLIES HVP400 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
MEET IEC 61000-3-2 HARMONIC CORRECTION
THIRD-WIRE CURRENT SHARING
OR-ING DIODES FOR N+1 REDUNDANCY
HOT-SWAPPABLE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN 55022 CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Input Connector: IEC320-3P & On/Off Switch.
Input Frequency: 47-63Hz.
Inrush Current: ≤ 30A @230Vac by active inrush
current limiter circuit.
Input Current: 5.8A @ 115Vac, 2.6A @ 230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet EN 55022 Class B.
Hold-up Time: Typ. 7.2-12mS @ 115Vac and
Typ. 35-42mS @ 230Vac.
Power OK Signal: Available at VO1 & VO2.
Power Factor Correction: Meet IEC 61000-3-2 Harmonic
Correction. PF typ. 0.92-0.98.
Over Temp. Protection: By thermostat.
Power Disable: Pin P3-2/open=shut-down.
Pin P3-2/short=Operation.
Power On LED Indicator: Installed.
Earth Leakage: Less than 0.5mA @230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connector: B-S/S-T/Molex MLX5045.
Output Wattage: Typ. 350-400 watts.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux.VO2 typ. ±1-2% (Magnetic Amp.).
Aux.VO3 typ. ±3.0% (Couple Common Choke).
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at main VO1.
Remote Sense: Available at VO1 & VO2 rail.
Redundancy: Available for N+1 redundancy operation for
sharing the load.
Current Sharing: 3rd-wire current sharing for VO1
& VO2 rails.
OR-ing Diode: Installed in VO1,2,3.
Adjustability: Available at VO1 & VO2.
Output LED Indicator: Installed in VO1,2,3.
Overload Protection (OLP): Fully protected against
output overload and short circuit.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 65-70%.
Switching Frequency: Fixed frequency at 56K Hz.
Circuit Topology: PWM Fixed Frequency Forward Circuit.
Transient Response: Output voltage returns in
less than 3mS following
a 25% load change.
Safety Standard: UL 60950-1/EN 60950-1 Class I.
Hot Swappable: Available.
Power Density: 2.95 Watts / Cubic Inch.
Operating Temperature: 0 to +50°C under 35 cfm forced
air cooling for full load.
Storage Temperature: -20 to +85 °C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: At least required 35 cfm forced cooling air flow
for full load operation.
MTBF: 180,000 hours at full load and 25°C by
MIL-HDBK-217F spec.
Construction: Enclosure box.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
In application
-63-
OUTPUT VOLTAGE / CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HVP400-S033850
HVP400-S050700
HVP400-S120300
HVP400-S150250
HVP400-S240160
HVP400-S280140
HVP400-S360110
HVP400-S480085
DUAL OUTPUT
MAIN VO1 @★#≡⊙
Typ.
Volt.
85.0A
3.3V
70.0A
5.0V
30.0A
12.0V
25.0A
15.0V
16.0A
24.0V
14.0A
28.0V
11.0A
36.0V
8.5A
48.0V
MODEL NO.
HVP400-D033E
HVP400-D033I
HVP400-D033K
HVP400-D033M
HVP400-D050I
HVP400-D050K
HVP400-D050M
MAIN VO1 @★#≡⊙
Typ.
Volt.
70.0A
+3.3V
70.0A
+3.3V
70.0A
+3.3V
70.0A
+3.3V
55.0A
+5.0V
55.0A
+5.0V
55.0A
+5.0V
AUX. VO2 @▲◇#≡⊙
Typ.
Volt.
20.0A
5.0V
10.0A
12.0V
8.0A
15.0V
5.0A
24.0V
10.0A
12.0V
8.0A
15.0V
5.0A
24.0V
TRIPLE OUTPUT
MAIN VO1 @★#≡⊙ AUX. VO2 @▲◇#≡⊙
Typ.
Typ.
Volt.
Volt.
70.0A
25.0A
HVP400-T033EI
+3.3V
5.0V
70.0A
10.0A
HVP400-T033II
+3.3V
12.0V
50.0A
25.0A
HVP400-T050DI
+5.0V
3.3V
50.0A
10.0A
HVP400-T050II
+5.0V
12.0V
50.0A
10.0A
HVP400-T050IE
+5.0V
12.0V
50.0A
5.0A
HVP400-T050MI
+5.0V
24.0V
50.0A
8.0A
HVP400-T050KK
+5.0V
15.0V
MODEL NO.
Symbol: "★" OVP built-in.
"@" Adjustable.
"◇" Floating(or isolated) output.
"≡" Active current sharing. "▲" Installed with magnetic amplifier.
"■" Couple common choke.
MECHANICAL DIMENSIONS: MM [INCHES]
AUX. VO3 ■◇⊙
Typ.
Volt.
3.0A
12.0V
3.0A
12.0V
3.0A
12.0V
3.0A
12.0V
3.0A
5.0V
3.0A
12.0V
3.0A
15.0V
"#" Remote sensing.
"⊙" Installed with OR-ing diode.
WEIGHT: 2,400.0g (85.0 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC INPUT
ASSIGNMENT
AC-L
AC-N
AC-G
CNTR & PIN#
L
N
G
SINGLE O/P
DUAL & TRIPLE O/P
ASSORTED SIGNALS
DCDCPower Power DC
VO1
VO1
+VO2 -VO2 +VO3 -VO3 +VO1# -VO1# +VO1≡ -VO1≡ +VO2# -VO2# +VO2≡ -VO2≡
COM
COM
Good Disable COM
P1P1P1-V1
P1-V1
P2-4 P2-3 P2-2 P2-1 P3-4
P3-6
P3-3
P3-5
P4-4
P4-3
P4-2
P4-5 P4-1
P3-2 P3-1
COM
COM
Mating connector: P1 &P2 No-needed. P3 & P4 Molex MLX5051.