Omron E3X-DA21-S2M Digital fiber sensor Datasheet

New Product
Digital Fiber Sensors
E3X-DA-S
An Extensive of Standard Functions
to Support the World's Highest Level of
Stable Detection.
• "GIGA RAY" Giga Power Lighting Element to create a wide variety
of value.
• Power turning to easily set the optimum light level.
• Active Thereshold Control (ATC) reduces incorrect operation due to
dust, oil, or other influences.
• Automatic Power Control (APC) is always enabled to stabilize
emitter power with high accuracy.
Ordering Information
Amplifier Units [Dimensions➜page 23]
Type
Appearance
Pre-wired
(2 m)
Applicable wire-saving connector
(sold separately)
Model
Connecting
method
NPN output
E3X-DA21-S 2M
PNP output
E3X-DA51-S 2M
Standard
models
Wire-saving
connector ✽
Pre-wired
(2 m)
E3X-DA7-S
E3X-DA21R-S 2M
Pre-wired
(2 m)
E3X-DA7R-S
E3X-DA21F-S 2M
E3X-DA51R-S 2M
E3X-DA7F-S
---
---
Master
connector
E3X-CN21
Slave
connector
E3X-CN22
---
---
Master
connector
E3X-CN21
Slave
connector
E3X-CN22
E3X-DA9R-S
E3X-DA51F-S 2M
High-speed
response
models
Wire-saving
connector ✽
Model
E3X-DA9-S
Ultra-long-term
APC models
Wire-saving
connector ✽
Type
---
---
Master
connector
E3X-CN11
Slave
connector
E3X-CN12
E3X-DA9F-S
✽ An Wire-saving connector sold separately is required.
1
E3X-DA-S
Wire-saving connector (sold separately)
Type
Appearance
Protection stickers attached [Dimensions➜page 25]
Cable length
No. of conductors
Model
Master connector
4
E3X-CN21
Slave connector
2
E3X-CN22
Master connector
3
E3X-CN11
Slave connector
1
E3X-CN12
2m
Note: The E3X-CN11/12 can also be used to connect to the E3X-DA@-S (@: 7/9) or the E3X-DA@R-S (@: 7/9), but the output lines will support
only 1 channel. Output function for channel 2 or APC alarm output function will be disabled.
Accessories (sold separately)
Mounting Brackets [Dimensions➜page 26]
Appearance
End Plate [Dimensions➜page 26]
Model
Quantity
E39-L143
1
Appearance
Model
Quantity
PFP-M
1
Product Overview
}: Strong point of the model
Types
Connecting
method
Models
Item
Input/output
Performance
External input
Output
2
Pre-wired
Wire-saving
connector
E3X-DA21-S
E3X-DA51-S
E3X-DA7-S
E3X-DA9-S
1 input
---
Ultra-long-term APC models
---: Not provided
High-speed response models
Pre-wired
Wire-saving
connector
Pre-wired
Wire-saving
connector
E3X-DA21R-S
E3X-DA51R-S
E3X-DA7R-S
E3X-DA9R-S
E3X-DA21F-S
E3X-DA51F-S
E3X-DA7F-S
E3X-DA9F-S
1 input
---
---
2 outputs
1 output and 1 APC alarm output
1 output
Sensing distance
with E32-T11R
280 to 2,000 mm
(Depends on response time)
140 to 1,000 mm
(Depends on response time)
280 mm
(Only Super-high-speed Mode)
Sensing distance
with E32-D11R
100 to 840 mm
(Depends on response time)
50 to 420 mm
(Depends on response time)
100 mm
(Only Super-high-speed Mode)
Giga Power
(GIGA RAY)
}
(Margin: × 160)
{
{
High-speed
response
{
(80 μs)
{
(80 μs)
}
(46 μs)
{
{
{
Automatic power
control (APC)
{
}
(Ultra-long-term APC)
{
Timer
{
{
{
ATC
{
{
{
Key lock
{
{
{
Easy key lock
(switchable)
---
{
{
APC margin
display
---
{
---
Slow-motion display
---
---
{
Power tuning
Function
Standard models
{: Provided
E3X-DA-S
Ratings and Specifications
Amplifier Units
Item
Type
Standard models
Ultra-long-term APC models
High-speed response models
Model
E3X-DA@-S (@: 21/51/7/9)
E3X-DA@R-S (@: 21/51/7/9)
E3X-DA@F-S (@: 21/51/7/9)
Light source
(wavelength)
Red,4-element LED (625 nm)
Power supply voltage
12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption
Normal mode
: 960 mW max. (Current consumption: 40 mA max. at 24 VDC, 80 mA max. at 12 VDC)
Power saving ECO1: 720 mW max. (Current consumption: 30 mA max. at 24 VDC, 60 mA max. at 12 VDC)
Power saving ECO2: 600 mW max. (Current consumption: 25 mA max. at 24 VDC, 50 mA max. at 12 VDC)
Control output /
APC alarm output
Load power supply voltage: 26.4 VDC max.; NPN/PNP open collector;
load current: 50 mA max.; residual voltage: 2 V max.
External input ✽1
No-voltage input (contact / transistor) ✽2
Protection circuits
Power supply reverse polarity protection, output short-circuit protection and output reverse polarity protection
Super-highspeed Mode ✽3
High-speed
ReMode
sponse
Standard Mode
time
High-resolution
Mode
Tough Mode
Sensitivity setting
--NPN output: Operate: 46 μs, Reset: 48 μs
PNP output: Operate: 51 μs, Reset: 53 μs
Operate or reset: 80 μs
Operate or reset: 250 μs
Operate or reset: 1 ms
---
Operate or reset: 4 ms
Operate or reset: 16 ms
Teaching or manual method
Power tuning
Light emission power and reception gain, digital control method
Differential
detection
Switchable between Single-edge and Double-edge Detection Modes.
Single edge: Set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms.
Double edge: Set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms
Automatic
power control
(APC)
Always enabled.
High-speed control of emission current
Wide-range APC for the E3X-DA@R-S
---
Select from timer disabled, OFF-delay, ON-delay, One-shot, or ON-delay + OFF-delay timer
Functions
Timer
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms
increments, and 1 to 5 s set in 1-s increments)
ATC
Provided
APC margin
display
---
Slow-motion
display
---
Zero reset
Negative values can be displayed. (Threshold value is shifted.)
Resetting
settings
Select from initial reset (factory defaults) or user reset (saved settings).
Mutual
interference
prevention
Possible for up to 10 units ✽4
ECO Mode ✽5
Select from OFF (digital display lit), ECO1 (digital display dimmed), and ECO2 (digital display OFF).
External input
setting ✽1
Select from teaching operations, power tuning, zero reset, emitter OFF, or
ATC start.
Output setting
Select from output for each channel,
area output, or self-diagnosis.
Operation indicator for
channel 1(orange)
Operation indicator for
channel 2(orange)
✽1. Only for Pre-wired models.
✽2. The following details apply to inputs.
Indicator
Contact input (relay or switch)
Provided
--Provided
---
---
--Operation indicator for
channel 1(orange)
APC alarm output indicator (orange)
Operation indicator for
channel 1(orange)
Power tuning indicator (orange)
Non-contact input (transistor)
NPN
ON: Shorted to 0 V (sourcing current: 1 mA max.).
OFF: Open or shorted to Vcc.
ON: 1.5 V max. (sourcing current: 1 mA max.)
OFF: Vcc - 1.5 V to Vcc (leakage current: 0.1 mA max.)
PNP
ON: Shorted to Vcc (sinking current: 3 mA max.).
OFF: Open or shorted to 0 V.
ON: Vcc - 1.5 V to Vcc (sinking current: 3 mA max.)
OFF: 1.5 V max. (leakage current: 0.1 mA max.)
✽3. The communications function and mutual interference prevention function are disabled if detection is set to Super-high-speed mode.
✽4. Mutual interference prevention is enabled if Amplifier Units are connected together. It is also enabled in the same way if E3X-DA-S-series Units
and E3C-LDA-series Units are used together. If power tuning is enabled, mutual interference prevention can be used for up to six units.
✽5. For the E3X-DA@-S (@: 21/51/7/9), the rated sensing distance is approximately 1/2 and the incident level is approximately 1/3 of the normal
levels when ECO mode is enabled.
3
E3X-DA-S
Item
Model
E3X-DA@-S (@: 21/51/7/9)
E3X-DA@R-S (@: 21/51/7/9)
E3X-DA@F-S (@: 21/51/7/9)
Digital display
Select from incident level + threshold or other 6 patterns (Refer to 6. Display switch on page 17.)
Display orientation
Switching between normal / reversed display is possible.
Key lock
Key lock
Ambient illumination
(Receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight: 20,000 lux max.
Maximum connectable
Units
16 (The ambient temperature specification depends on the number of connected units.)
Key lock / Easy key lock.
Ambient temperature
range
Operating: Groups of 1 to 2 Amplifiers: −25 to 55°C
Groups of 3 to 10 Amplifiers: −25 to 50°C
Groups of 11 to 16 Amplifiers: −25 to 45°C
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute
Vibration resistance
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
Shock resistance
Destruction: 500 m/s2 for 3 times each in X, Y and Z directions
Degree of protection
IEC 60529 IP50 (with Protective Cover attached)
Connection method
Pre-wired (standard length 2 m) or Wire-saving connector
Storage: −30 to 70°C (with no icing or condensation)
Weight (packed state)
Materials
Pre-wired models: Approx. 100 g, Wire-saving connector models: Approx. 55 g
Case
Polybutylene terephthalate (PBT)
Cover
Polycarbonate (PC)
Accessories
Instruction Manual
Wire-saving connectors
Item
Model
E3X-CN12
2.5 A
Rated voltage
50 V
Contact resistance
20 mΩ max. (20 mVDC max., 100 mA max.)
(The figure is for connection to the Amplifier Unit and the adjacent connector. It does not include the conductor
resistance of the cable.)
No. of insertions
Destruction: 50 times
(The figure for the number of insertions is for connection to the Amplifier Unit and the adjacent connector.)
Materials
Housing
Polybutylene terephthalate (PBT)
Contacts
Phosphor bronze / gold-plated nickel
Weight (packed state)
4
E3X-CN21/22/11
Rated current
Approx. 55 g
Approx. 25 g
E3X-DA-S
Sensing Distance
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Screw-shaped model
Sensing
method
Size
M3
Throughbeam
models
M4
Sensing distance (unit: mm)
Sensing
direction
Model
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
Straight
E32-T21R 2M
450
300
250
150
60
Right angle
E32-T11N 2M
2,000
1,400
1,000
700
280
E32-T11R 2M
2,000
1,400
1,000
700
280
E32-TC200 2M
2,800
2,000
1,550
1,000
400
4,000 ✽
3,400
2,700
1,740
700
Straight
E32-T11L 2M
Right angle
M3
Straight
M4
Reflective
models
Tough mode
Right angle
E32-C31N 2M
110
80
50
46
14
E32-D21R 2M
140
100
60
40
16
E32-C31 2M
330
240
150
100
44
E32-D211R 2M
140
100
60
40
16
E32-D11N 2M
840
600
350
240
100
E32-C11N 2M
780
560
350
320
100
E32-D11R 2M
M6
Straight
E32-DC200 2M
840
600
350
240
100
1,400
1,000
600
400
180
E32-CC200 2M
1,400
1,000
600
400
180
E32-D11L 2M
1,820
1,300
800
520
220
High-speed
mode
Super-highspeed mode
280
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Flat model
Sensing
method
Sensing distance (unit: mm)
Sensing
direction
Top view
Throughbeam
models
Side view
Flat view
Top view
Reflective
models
Side view
Flat view
Size
Model
Tough mode
High-resolution
mode
Standard
E32-T15XR 2M
2,000
1,400
1,000
700
Small
E32-T25XR 2M
450
300
250
150
60
Standard
E32-T15YR 2M
750
550
450
260
100
Small
E32-T25YR 2M
170
120
100
50
20
Standard
E32-T15ZR 2M
750
550
450
260
100
Small
E32-T25ZR 2M
170
120
100
50
20
Standard
E32-D15XR 2M
840
600
350
240
100
Small
E32-D25XR 2M
140
100
60
40
16
Standard
E32-D15YR 2M
200
140
100
52
24
Small
E32-D25YR 2M
40
28
16
10
4
Standard
E32-D15ZR 2M
200
140
100
52
24
Small
E32-D25ZR 2M
40
28
16
10
4
High-speed
mode
Super-highspeed mode
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Cylindrical model
Sensing
method
Sensing
direction
Throughbeam
models
Top view
Side view
Sensing distance (unit: mm)
Size
Top view
E32-T223R 2M
φ3
E32-T12R 2M
Tough mode
450
300
250
150
60
2,000
1,400
1,000
700
280
E32-T24R 2M
170
120
100
50
20
E32-T14LR 2M
750
550
450
260
100
φ2
E32-D22B 2M
140
100
60
40
16
E32-D32 2M
330
240
150
100
44
E32-D22R 2M
140
100
60
40
16
E32-D32L 2M
700
500
300
200
90
φ2
E32-D24R 2M
70
52
30
20
8
φ6
E32-D14LR 2M
220
160
100
60
28
High-speed
mode
Super-highspeed mode
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Model equipped with sleeve
Sleeve size
φ0.25 × 5
Throughbeam
models
Reflective
models
φ0.5 × 40
Standard
mode
φ3
Fiber Unit
Sensing
method
High-resolution
mode
φ1
φ3
Side view
Model
φ1
φ1.5
Reflective
models
Standard
mode
Sensing distance (unit: mm)
Mounting size
φ3
Model
E32-T333-S5 1M
E32-T33 1M
φ0.9 × 40
M3
E32-TC200F4R 2M
φ1.2 × 90
M4
E32-TC200BR 2M
Tough mode
High-resolution
mode
Standard
mode
35
25
20
12
8
150
110
90
50
20
450
300
250
150
60
2,000
1,400
1,000
700
280
φ0.5 × 15
φ2
E32-D331 2M
14
10
6
4
2
φ0.8 × 15
φ3
E32-D33 2M
70
50
30
20
8
φ1.2 × 40
M3
E32-DC200F4R 2M
140
100
60
40
16
φ2.5 × 90
M6
E32-DC200BR 2M
840
600
350
240
100
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
5
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Movable section (Flexibility)
Sensing
Type
method
Screw-shaped
model
Throughbeam
models
Cylindrical
model
Flat model
Screw-shaped
model
Reflective
models
Cylindrical
model
Flat model
Fiber Unit
Heat-resistance model
Sensing
Operating
method
temperature
100°C
Throughbeam
models
150°C
Amplifier Unit
Size
M3
M4
φ1.5
φ3
Standard
Small
M3
M4
M6
φ1.5
φ3
Standard
Small
Lens
--Lens
High-power lens
--Lens
High-power lens
---
350°C
Reflective
models
E32-T21 2M
E32-T11 2M
E32-T22B 2M
E32-T12B 2M
E32-T15XB 2M
E32-T25XB 2M
E32-D21 2M
E32-D21B 2M
E32-D11 2M
E32-D22B 2M
E32-D221B 2M
E32-D15XB 2M
E32-D25XB 2M
Tough mode
680
2,500
680
2,500
2,500
500
140
300
840
140
300
840
240
Amplifier Unit
200°C
100°C
150°C
200°C
350°C
400°C
Model
Lens
--High-power lens
---
Model
E32-T51R 2M
E32-T51R 2M + E39-F1
E32-T51R 2M + E39-F16
E32-T51 2M
E32-T51 2M + E39-F1-33
E32-T51 2M + E39-F16
E32-T54 2M
E32-T81R-S 2M
E32-T61-S 2M
E32-T61-S 2M + E39-F1
E32-T61-S 2M
E32-T61-S 2M + E39-F16
E32-D51R 2M
E32-D51 2M
E32-D81R 2M
E32-D61 2M
E32-D73 2M
Tough mode
1,600
4,000 ✽
4,000 ✽
2,800
4,000 ✽
4,000 ✽
840
1,000
1,680
4,000 ✽
1,680
4,000 ✽
670
1,120
420
420
280
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highmode
mode
mode
speed mode
480
400
220
90
1,800
1,350
900
360
480
400
220
90
1,800
1,350
900
360
1,800
1,350
900
360
360
300
170
70
100
60
40
16
220
140
90
40
600
350
240
100
100
60
40
16
220
140
90
40
600
350
240
100
170
100
60
30
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highmode
mode
mode
speed mode
1,100
800
560
225
4,000 ✽
4,000 ✽
3,900
1,500
4,000 ✽
4,000 ✽
4,000 ✽
4,000 ✽
2,000
1,500
1,000
400
4,000 ✽
4,000 ✽
2,300
1,400
4,000 ✽
4,000 ✽
4,000 ✽
4,000 ✽
600
450
300
120
720
550
360
140
1,200
900
600
240
4,000 ✽
4,000 ✽
4,000 ✽
1,800
1,200
900
600
240
4,000 ✽
4,000 ✽
4,000 ✽
3,100
480
280
190
80
800
450
320
144
300
180
120
54
300
180
120
54
200
120
80
36
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Chemical-resistance / Oil-resistance model
Sensing
Type
method
φ5
φ7.2
φ5
Heat-resistance model
Throughφ5
beam
Side view
models
M4
Chemical-resistance cable
M4
Right angle Chemical-resistance cable
φ6
φ7
Reflective
Side view
models
M6
Chemical-resistance cable
Amplifier Unit
Model
E32-T12F 2M
E32-T11F 2M
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highTough mode
mode
mode
mode
speed mode
4,000 ✽1
4,000 ✽1
4,000 ✽1
1,600
4,000 ✽1
4,000 ✽1
4,000 ✽1
4,000 ✽1
2,600
1,000
E32-T51F 2M
4,000 ✽1
3,600
2,800
1,800
700
E32-T14F 2M
1,400
1,000
800
500
200
E32-T11U 2M
2,500
1,800
1,350
900
360
E32-T11NU 2M
1,440
1,040
800
520
200
E32-D12F 2M
--- ✽2
320
190
130
60
E32-D14F 2M
--- ✽2
140
80
60
20
E32-D11U 2M
840
600
350
240
100
✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
✽2. Even if there is no sensing object, the sensor will detect light that is reflected by the fluororesin.
Fiber Unit
Vacuum-resistance model
Sensing Operating ambient
method
temperature
Throughbeam
models
120°C
200°C
Amplifier Unit
Sensing
direction
Top view
Right angle
Model
E32-T51V 1M
E32-T51V 1M + E39-F1V
E32-T54V 1M
E32-T84SV 1M
Tough mode
720
3,780
580
1,760
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highmode
mode
mode
speed mode
520
400
260
100
2,700
2,000
1,360
520
420
250
200
70
1,250
950
640
260
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
6
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Long distance / Dust resistance (High-power),
Detection through gaps (Narrow vision field)
Sensing
method
Type
High-power
(integrated unit)
Throughbeam
models
High-power
(with lens unit)
Sensing direction /
Lens type
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
Top view
E32-T17L 10M
20,000 ✽1
20,000 ✽1
20,000 ✽1
20,000 ✽1
8,000
Side view
E32-T14 2M
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,800
High-power
E32-T11N 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,000
Ultrahigh-power
E32-T11N 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,600
High-power
E32-T11R 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,000
Ultrahigh-power
E32-T11R 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,600
Side view
E32-T11R 2M + E39-F2
1,450
1,040
800
500
200
High-power
E32-TC200 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,000
Ultrahigh-power
E32-TC200 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
Side view
E32-TC200 2M + E39-F2
2,350
1,680
1,400
900
320
High-power
E32-T11 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,860
Ultrahigh-power
E32-T11 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
Side view
E32-T11 2M + E39-F2
2,300
1,640
1,320
860
320
High-power
E32-T11U 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,860
Ultrahigh-power
E32-T11U 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
Side view
Reflective
models
Sensing distance (unit: mm)
2,300
1,640
1,320
860
320
High-power
E32-T11NU 2M + E39-F1
E32-T11U 2M + E39-F2
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,600
1,000
Ultrahigh-power
E32-T11NU 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,800
High-power
E32-T81R-S 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,700
1,000
Ultrahigh-power
E32-T81R-S 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,800
Side view
E32-T81R-S 2M + E39-F2
1,000
720
550
360
140
High-power
E32-T61-S 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,800
Ultrahigh-power
E32-T61-S 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,100
Side view
E32-T61-S 2M + E39-F2
1,680
1,200
900
600
240
4,000 ✽2
3,800
2,500
1,000
Narrow vision field
(aperture angle: 4°)
Top view
E32-T22S 2M
4,000 ✽2
Side view
E32-T24S 2M
4,000 ✽2
3,500
2,600
1,740
700
High-power
Top view
E32-D16 2M
40 to 2,800
40 to 2,000
40 to 1,400
40 to 900
40 to 480
✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Minute object detection (Small-spot model)
Sensing
method
Reflective
models
Sensing distance (unit: mm)
Spot diameter
(mm)
Focal length
(mm)
φ0.1 to 0.6
(Variable)
6 to 15
E32-C42 1M + E39-F3A
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm
φ0.3 to 1.6
(Variable)
10 to 30
E32-C42 1M + E39-F17
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm
Model
Tough mode
Reflective
models
High-speed
mode
φ0.1
E32-C42S 1M
7
E32-C41 1M + E39-F3A-5
Spot diameter of 0.1 mm at 7 mm
φ0.2
17
E32-C41 1M + E39-F3B
Spot diameter of 0.2 mm at 17 mm
7
E32-C31 2M + E39-F3A-5
Spot diameter of 0.5 mm at 7 mm
17
E32-C31 2M + E39-F3B
Spot diameter of 0.5 mm at 17 mm
φ6
50
E32-L15 2M
φ4
Parallel light
0 to 20
φ3
50
φ0.5
Spot diameter of 6 mm at 50 mm
Sensing distance in all mode (40 to 100 mm)
E32-C31 2M + E39-F3C
Spot diameter of 4 mm max. at 0 to 20 mm
E32-C11N 2M + E39-F18
Spot diameter of 3 mm at 50 mm
E32-CC200 2M + E39-F18
Spot diameter of 3 mm at 50 mm
Amplifier Unit
Area range
11 mm
E3X-DA@-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Sensing
direction
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
440
Side view
E32-T16PR 2M
3,100
2,200
1,700
1,120
Flat view
E32-T16JR 2M
2,750
2,000
1,500
960
380
4,000 ✽
3,400
2,600
1,700
680
700
500
300
200
90
30 mm
11 mm
Super-highspeed mode
Spot diameter of 0.1 mm at 5 mm
Area-sensing (Area beam)
Throughbeam
models
Standard
mode
5
Fiber Unit
Sensing
method
High-resolution
mode
E32-T16WR 2M
Side view
E32-D36P1 2M
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
7
E3X-DA-S
E3X-DA@-S (@: 21/51/7/9) ƒ E3X-DA@F-S(@: 21/51/7/9)
Note: The E3X-DA@F-S uses only Super-high-speed mode. The sensing distance is the same as for the Super-high-speed mode of the E3X-DA@-S.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Detection without background interference (Convergent-reflective)
Sensing
method
Sensing
direction
Size
Flat view
Reflective
models
Top view
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Standard
E32-L16-N 2M ✽
Small
E32-L24S 2M ✽
0 to 4
E32-L25L 2M ✽
5.4 to 9 (center 7.2)
E32-L24L 2M ✽
2 to 6 (center 4)
---
Flat view
Model
Sensing distance (unit: mm)
Super-highspeed mode
0 to 15
0 to 12
✽ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Detection of transparent objects (Retro-reflective)
Sensing
method
Retroreflective
models
Type
Sensing distance (unit: mm)
Model
Tough mode
Square
E32-R16 5M + E39-R1 (attached) ✽1
Small
E32-R21 2M + E39-R3 (attached) ✽1
Film detection ✽2
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
150 to 1,500
10 to 250
E32-C31 2M + E39-F3R+E39-RP37 ✽1
250
200
E32-C31 2M + E39-F3R+E39-RSP1 ✽1
450
300
--100
✽1. When using a highly reflective object, light reflected from the object may affect the sensor.
✽2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens
Unit. Be sure to check operation in advance.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
FPD / Semiconductor / Solar battery industry
Sensing
method
Application
Operating
temperature
Throughbeam
models
Wafer mapping
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
0 to 15
0 to 12
0 to 15
0 to 12
E32-A08 2M ✽
10 to 20
---
300°C
E32-A08H2 3M ✽
10 to 20
---
70°C
E32-A09 2M
15 to 38
---
150°C
E32-A09H 2M
15 to 38
---
300°C
E32-A09H2 2M
20 to 30
---
60°C
E32-L11FP 5M
8 to 20 mm from end of lens (recommended: 11 mm)
70°C
E32-L12FS 5M
8 to 20 mm from end of lens (recommended: 11 mm)
85°C
E32-L11FS 5M
Glass substrate
alignment
WET process
Tough mode
E32-L16-N 2M ✽
70°C
Glass substrate
mapping
Model
E32-L16-N 2M ✽
Glass detection
Reflective
models
Sensing distance (unit: mm)
70°C
8 to 20 mm from end of lens (recommended: 11 mm)
E32-A03 2M
3,220
2,300
1,780
1,200
500
E32-A03-1 2M
3,220
2,300
1,780
1,200
500
E32-A04 2M
1,280
920
680
450
200
E32-A04-1 2M
1,280
920
680
450
200
✽ If operation is affected by the background, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@-S (@: 21/51/7/9)
Liquid-level detection model
Sensing
method
Sensing
direction
Sensing distance (unit: mm)
Pipe diameter
No limit
Reflective Mounted to pipe
models
Wet
φ8 to 10 mm
---
Model
E32-D36T 5M ✽1, ✽2
E32-L25T 2M
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
Applicable pipe: Transparent (no restriction on diameter)
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,
recommended pipe wall thickness: 1 mm
E32-D82F1 4M ✽1
Wet model
✽1. If a high level of light is received, perform power tuning or set operation to ECO mode to reduce the amount of light that is received.
✽2. In Tough mode, detection may not be possible depending on the pipe diameter. Check operation with the pipe that will be used.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
8
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Screw-shaped model
Sensing
method
Size
M3
Throughbeam
models
M4
Sensing distance (unit: mm)
Sensing
direction
Tough mode
High-resolution
mode
E32-T21R 2M
220
160
130
75
30
1,000
700
500
350
140
E32-T11R 2M
1,000
700
530
350
140
E32-TC200 2M
1,400
1,000
760
500
200
E32-T11L 2M
2,000
1,700
1,350
870
350
E32-C31N 2M
55
40
25
23
7
E32-D21R 2M
70
50
30
20
8
22
Straight
Straight
Right angle
M6
Straight
165
120
75
50
E32-D211R 2M
E32-C31 2M
70
50
30
20
8
E32-D11N 2M
420
300
175
120
50
E32-C11N 2M
390
280
175
160
50
E32-D11R 2M
420
300
170
120
50
E32-DC200 2M
700
500
300
200
90
E32-CC200 2M
700
500
300
200
90
E32-D11L 2M
910
650
400
260
110
High-speed
mode
Super-highspeed mode
140
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Flat model
Sensing distance (unit: mm)
Sensing
direction
Top view
Side view
Flat view
Top view
Reflective
models
Side view
Flat view
Size
Model
Tough mode
E32-T15XR 2M
1,000
700
530
350
E32-T25XR 2M
220
160
130
75
30
Standard
E32-T15YR 2M
370
270
210
130
50
Small
E32-T25YR 2M
85
60
50
25
10
Standard
E32-T15ZR 2M
370
270
210
130
50
Small
E32-T25ZR 2M
85
60
50
25
10
Standard
E32-D15XR 2M
420
300
170
120
50
Small
E32-D25XR 2M
70
50
30
20
8
Standard
E32-D15YR 2M
100
70
40
26
12
Small
E32-D25YR 2M
20
14
8
5
2
Standard
E32-D15ZR 2M
100
70
40
26
12
Small
E32-D25ZR 2M
20
14
8
5
2
High-speed
mode
Super-highspeed mode
Amplifier Unit
Sensing
direction
Throughbeam
models
Top view
Side view
Top view
Reflective
models
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Size
Model
φ1
E32-T223R 2M
φ3
E32-T12R 2M
Tough mode
High-resolution
mode
220
160
130
75
30
1,000
700
530
350
140
E32-T24R 2M
85
60
50
25
10
φ3
E32-T14LR 2M
370
270
210
130
50
φ1.5
E32-D22B 2M
φ2
E32-D32 2M
70
50
30
20
8
160
120
75
50
22
E32-D22R 2M
70
50
30
20
8
E32-D32L 2M
350
250
150
100
45
φ2
E32-D24R 2M
35
26
15
10
4
φ6
E32-D14LR 2M
110
80
45
30
14
High-speed
mode
Super-highspeed mode
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Model equipped with sleeve
Sleeve size
φ0.25 × 5
Throughbeam
models
Reflective
models
φ0.5 × 40
Standard
mode
φ1
φ3
Side view
Standard
mode
Small
Cylindrical model
Sensing
method
High-resolution
mode
Standard
Fiber Unit
Sensing
method
Super-highspeed mode
E32-T11N 2M
M4
Throughbeam
models
High-speed
mode
Straight
M3
Sensing
method
Standard
mode
Right angle
Right angle
Reflective
models
Model
Sensing distance (unit: mm)
Mounting size
φ3
Model
Tough mode
High-resolution
mode
Standard
mode
E32-T333-S5 1M
17
12
10
6
4
E32-T33 1M
75
55
45
25
10
220
160
130
75
30
1,000
700
530
350
140
φ0.9 × 40
M3
E32-TC200F4R 2M
φ1.2 × 90
M4
E32-TC200BR 2M
φ0.5 × 15
φ2
E32-D331 2M
7
5
3
2
0.8
φ0.8 × 15
φ3
E32-D33 2M
35
25
16
10
4
φ1.2 × 40
M3
E32-DC200F4R 2M
70
50
30
20
8
φ2.5 × 90
M6
E32-DC200BR 2M
420
300
170
120
50
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
9
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Movable section (Flexibility)
Sensing
Type
method
Screw-shaped
model
Throughbeam
models
Cylindrical
model
Flat model
Screw-shaped
model
Reflective
models
Cylindrical
model
Flat model
Fiber Unit
Heat-resistance model
Sensing
Operating
method
temperature
100°C
Throughbeam
models
150°C
Amplifier Unit
Size
M3
M4
φ1.5
φ3
Standard
Small
M3
M4
M6
φ1.5
φ3
Standard
Small
Lens
--Lens
High-power lens
--Lens
High-power lens
---
Reflective
models
100°C
150°C
200°C
350°C
400°C
E32-T21 2M
E32-T11 2M
E32-T22B 2M
E32-T12B 2M
E32-T15XB 2M
E32-T25XB 2M
E32-D21 2M
E32-D21B 2M
E32-D11 2M
E32-D22B 2M
E32-D221B 2M
E32-D15XB 2M
E32-D25XB 2M
Tough mode
340
1,250
340
1,250
1,250
250
70
150
420
70
150
420
120
Amplifier Unit
200°C
350°C
Model
Lens
--High-power lens
---
Model
E32-T51R 2M
E32-T51R 2M + E39-F1
E32-T51R 2M + E39-F16
E32-T51 2M
E32-T51 2M + E39-F1-33
E32-T51 2M + E39-F16
E32-T54 2M
E32-T81R-S 2M
E32-T61-S 2M
E32-T61-S 2M + E39-F1
E32-T61-S 2M
E32-T61-S 2M + E39-F16
E32-D51R 2M
E32-D51 2M
E32-D81R 2M
E32-D61 2M
E32-D73 2M
Tough mode
800
4,000 ✽
4,000 ✽
1,400
4,000 ✽
4,000 ✽
420
500
840
4,000 ✽
840
4,000 ✽
330
560
210
210
140
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highmode
mode
mode
speed mode
240
200
110
45
900
680
450
180
240
200
110
45
900
680
450
180
900
680
450
180
180
150
85
35
50
30
20
8
110
70
45
20
300
170
120
50
50
30
20
8
110
70
45
20
300
170
120
50
85
50
30
15
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highmode
mode
mode
speed mode
560
425
280
110
3,900
2,900
1,900
760
4,000 ✽
4,000 ✽
3,600
1,400
1,000
760
500
200
3,400
2,660
1,150
700
4,000 ✽
4,000 ✽
4,000 ✽
2,600
300
230
150
60
360
280
180
70
600
450
300
120
4,000 ✽
3,400
2,200
900
600
450
300
120
4,000 ✽
4,000 ✽
3,900
1,500
240
135
95
40
400
230
160
72
150
90
60
27
150
90
60
27
100
60
40
18
✽ The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Chemical-resistance / Oil-resistance model
Sensing
Type
method
φ5
φ7.2
φ5
Heat-resistance model
Throughφ5
beam
Side view
models
M4
Chemical-resistance cable
M4
Right angle Chemical-resistance cable
φ6
φ7
Reflective
Side view
models
M6
Chemical-resistance cable
Amplifier Unit
Model
E32-T12F 2M
E32-T11F 2M
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highTough mode
mode
mode
mode
speed mode
4,000 ✽1
3,000
2,000
800
4,000 ✽1
3,500
2,500
2,000
1,300
520
E32-T51F 2M
2,500
1,800
1,400
900
350
E32-T14F 2M
700
500
400
250
100
E32-T11U 2M
1,250
900
680
450
180
E32-T11NU 2M
720
520
400
260
100
E32-D12F 2M
--- ✽2
160
95
65
30
E32-D14F 2M
✽2
70
40
30
10
420
300
170
120
50
---
E32-D11U 2M
✽1. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
✽2. The sensor will detect light even if there is no sensing object, and so Tough Mode cannot be used.
Fiber Unit
Vacuum-resistance model
Sensing Operating ambient
method
temperature
Throughbeam
models
120°C
200°C
Amplifier Unit
Sensing
direction
Top view
Right angle
Model
E32-T51V 1M
E32-T51V 1M + E39-F1V
E32-T54V 1M
E32-T84SV 1M
Tough mode
360
1,890
290
880
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
High-resolution
Standard
High-speed Super-highmode
mode
mode
speed mode
260
200
130
50
1,350
1,000
680
260
210
130
100
35
630
480
320
130
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
10
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Long distance / Dust resistance (High-power),
Detection through gaps (Narrow vision field)
Sensing
method
Type
High-power
(integrated unit)
Throughbeam
models
Reflective
models
High-power
(with lens unit)
Sensing distance (unit: mm)
Sensing direction /
Lens type
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
Top view
E32-T17L 10M
20,000 ✽1
20,000 ✽1
20,000 ✽1
10,000
4,000
Side view
E32-T14 2M
4,000 ✽2
4,000 ✽2
3,400
2,250
900
High-power
E32-T11N 2M + E39-F1
4,000 ✽2
4,000 ✽2
3,700
2,400
970
Ultrahigh-power
E32-T11N 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,800
High-power
E32-T11R 2M + E39-F1
4,000 ✽2
4,000 ✽2
3,700
2,400
970
✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
1,800
Ultrahigh-power
E32-T11R 2M + E39-F16
4,000
Side view
E32-T11R 2M + E39-F2
725
520
400
250
100
High-power
E32-TC200 2M + E39-F1
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,600
1,500
Ultrahigh-power
E32-TC200 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
Side view
E32-TC200 2M + E39-F2
1,170
840
700
450
160
High-power
E32-T11 2M + E39-F1
4,000 ✽2
4,000 ✽2
3,600
2,300
930
Ultrahigh-power
E32-T11 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,300
Side view
E32-T11 2M + E39-F2
1,150
820
660
430
160
High-power
E32-T11U 2M + E39-F1
4,000 ✽2
4,000 ✽2
3,600
2,300
930
Ultrahigh-power
E32-T11U 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
4,000 ✽2
2,300
Side view
E32-T11U 2M + E39-F2
1,150
820
660
430
160
High-power
E32-T11NU 2M + E39-F1
4,000 ✽2
2,600
2,000
1,300
500
Ultrahigh-power
E32-T11NU 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,300
1,300
High-power
E32-T81R-S 2M + E39-F1
4,000 ✽2
2,650
2,100
1,300
520
Ultrahigh-power
E32-T81R-S 2M + E39-F16
4,000 ✽2
4,000 ✽2
3,600
2,300
900
Side view
E32-T81R-S 2M + E39-F2
500
360
280
180
70
High-power
E32-T61-S 2M + E39-F1
4,000 ✽2
4,000 ✽2
3,400
2,200
900
Ultrahigh-power
E32-T61-S 2M + E39-F16
4,000 ✽2
4,000 ✽2
4,000 ✽2
3,900
1,500
Side view
E32-T61-S 2M + E39-F2
840
600
450
300
120
Narrow vision field
(aperture angle: 4°)
Top view
E32-T22S 2M
3,500
2,500
1,900
1,250
500
Side view
E32-T24S 2M
2,400
1,750
1,300
870
350
High-power
Top view
E32-D16 2M
40 to 1,400
40 to 1,000
40 to 700
40 to 450
40 to 240
✽1. The fiber length is 10 m on each side, so the sensing distance is given as 20,000 mm.
✽2. The fiber length is 2 m on each side, so the sensing distance is given as 4,000 mm.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Minute object detection (Small-spot model)
Sensing
method
Reflective
models
Sensing distance (unit: mm)
Spot diameter
(mm)
Focal length
(mm)
φ0.1 to 0.6
(Variable)
6 to 15
E32-C42 1M + E39-F3A
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm
φ0.3 to 1.6
(Variable)
10 to 30
E32-C42 1M + E39-F17
Spot diameter of 0.3 to 1.6 mm at 10 to 30 mm
Model
Tough mode
Reflective
models
High-speed
mode
5
E32-C42S 1M
7
E32-C41 1M + E39-F3A-5
Spot diameter of 0.1 mm at 7 mm
φ0.2
17
E32-C41 1M + E39-F3B
Spot diameter of 0.2 mm at 17 mm
7
E32-C31 2M + E39-F3A-5
Spot diameter of 0.5 mm at 7 mm
17
E32-C31 2M + E39-F3B
Spot diameter of 0.5 mm at 17 mm
φ6
50
E32-L15 2M
φ4
Parallel light
0 to 20
φ3
50
φ0.5
Spot diameter of 6 mm at 50 mm
Sensing distance in all mode (40 to 100 mm)
E32-C31 2M + E39-F3C
Spot diameter of 4 mm max. at 0 to 20 mm
E32-C11N 2M + E39-F18
Spot diameter of 3 mm at 50 mm
E32-CC200 2M + E39-F18
Spot diameter of 3 mm at 50 mm
Amplifier Unit
Area range
11mm
E3X-DA@R-S (@: 21/51/7/9)
Sensing distance (unit: mm)
Sensing
direction
Model
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
220
Side view
E32-T16PR 2M
1,550
1,100
840
560
Flat view
E32-T16JR 2M
1,370
980
750
480
190
E32-T16WR 2M
2,000
1,700
1,300
850
340
350
250
150
100
45
30mm
11mm
Super-highspeed mode
Spot diameter of 0.1 mm at 5 mm
Area-sensing (Area beam)
Throughbeam
models
Standard
mode
φ0.1
Fiber Unit
Sensing
method
High-resolution
mode
Side view
E32-D36P1 2M
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
11
E3X-DA-S
E3X-DA@R-S (@: 21/51/7/9)
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Detection without background interference (Convergent-reflective)
Sensing
method
Sensing
direction
Size
Flat view
Reflective
models
Top view
Tough mode
High-resolution
mode
Standard
mode
High-speed
mode
Standard
E32-L16-N 2M ✽
Small
E32-L24S 2M ✽
0 to 4
E32-L25L 2M ✽
5.4 to 9 (center 7.2)
E32-L24L 2M ✽
2 to 6 (center 4)
---
Flat view
Model
Sensing distance (unit: mm)
Super-highspeed mode
0 to 15
0 to 12
✽ If operation is affected by the background, perform power tuning to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Detection of transparent objects (Retro-reflective)
Sensing
method
Retroreflective
models
Type
Sensing distance (unit: mm)
Model
Tough mode
Square
E32-R16 5M + E39-R1 (attached) ✽1
Small
E32-R21 2M + E39-R3 (attached) ✽1
Film detection ✽2
High-resolution
mode
Standard
mode
High-speed
mode
Super-highspeed mode
150 to 1,500
10 to 250
E32-C31 2M + E39-F3R+E39-RP37 ✽1
250
200
150
100
50
E32-C31 2M + E39-F3R+E39-RSP1 ✽1
600
300
225
150
75
✽1. When using a highly reflective object, light reflected from the object may affect the sensor.
✽2. The effect may be small due to the film. Also, stable detection may not be possible when there is a sensing object directly in front of the Lens
Unit. Be sure to check operation in advance.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
FPD / Semiconductor / Solar battery industry
Sensing
method
Application
Operating
temperature
Glass detection
70°C
Glass substrate
alignment
Reflective
models
Glass substrate
mapping
WET process
Throughbeam
models
Wafer mapping
Sensing distance (unit: mm)
Model
Tough mode
High-resolution
mode
Standard
mode
E32-L16-N 2M ✽
0 to 15
E32-L16-N 2M ✽
0 to 15
High-speed
mode
Super-highspeed mode
0 to 12
0 to 12
E32-A08 2M ✽
10 to 20
300°C
E32-A08H2 3M ✽
10 to 20
70°C
E32-A09 2M
15 to 38
150°C
E32-A09H 2M
15 to 38
300°C
E32-A09H2 2M
20 to 30
60°C
E32-L11FP 5M
8 to 20 mm from end of lens (recommended: 11 mm)
70°C
E32-L12FS 5M
8 to 20 mm from end of lens (recommended: 11 mm)
85°C
E32-L11FS 5M
70°C
8 to 20 mm from end of lens (recommended: 11 mm)
E32-A03 2M
1,610
1,150
890
600
250
E32-A03-1 2M
1,610
1,150
890
600
250
E32-A04 2M
640
460
340
225
100
E32-A04-1 2M
640
460
340
225
100
✽ If operation is affected by the background, perform power tuning to reduce the amount of light that is received.
Fiber Unit
Amplifier Unit
E3X-DA@R-S (@: 21/51/7/9)
Liquid-level detection model
Sensing
method
Sensing
direction
Sensing distance (unit: mm)
Pipe diameter
No limit
Reflective Mounted to pipe
models
Wet
φ8 to 10mm
---
Model
E32-D36T 5M ✽
E32-L25T 2M
Tough mode
High-resolution
mode
High-speed
mode
Super-highspeed mode
Applicable pipe: Transparent (no restriction on diameter)
Applicable pipe: Transparent pipe with diameter of 8 to 10 mm,
recommended pipe wall thickness: 1 mm
E32-D82F1 4M ✽
✽ If a high level of light is received, perform power tuning to reduce the amount of light that is received.
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
12
Standard
mode
Wet model
E3X-DA-S
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Timing charts
Light-ON
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between brown and black (orange) leads)
E3X-DA21-S
E3X-DA21R-S
E3X-DA21F-S
Operation
selector
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between brown and black (orange) leads)
Dark-ON
E3X-DA21-S
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between brown and black (orange) leads)
DARK ON
(D-ON)
Operation
mode
Timing charts
Operation
selector
Light-ON
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between blue and black (orange) leads)
Dark-ON
Operation
indicator
(orange)
ch1
Brown
Load
Black
Control output Load
Orange ch1
Photoelectric
Sensor
main
circuit
Control output
ch2 ✽1
Pink
12 to
24 VDC
External
input ✽2
Blue
DARK ON
(D-ON)
LIGHT ON
(L-ON)
E3X-DA7-S
E3X-DA7R-S
E3X-DA7F-S
Operation indicator
(orange) ch2
Display
LIGHT ON
(L-ON)
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between brown and black (orange) leads)
Light-ON
Output circuit
✽1. For the E3X-DA21R-S, this is the APC alarm output.
This output does not exist on the E3X-DA21F-S.
✽2. This input does not exist the E3X-DA21F-S.
E3X-DA7-S
Operation indicator
(orange) ch2
Display
Operation
indicator
(orange)
ch1
Brown
Load
Black
Control output Load
Orange ch1
Control output
ch2 ✽
Photoelectric
Sensor
main
circuit
12 to
24 VDC
Blue
✽ For the E3X-DA7R-S, this is the APC alarm output.
This output does not exist on the E3X-DA7F-S.
PNP Output
Model
E3X-DA51-S
E3X-DA51R-S
E3X-DA51F-S
Dark-ON
Light-ON
E3X-DA9-S
E3X-DA9R-S
E3X-DA9F-S
Dark-ON
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between blue and black (orange) leads)
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between blue and black (orange) leads)
ch1/
Incident light
ch2
No incident light
Operation indicator ON
(orange)
OFF
ON
Output transistor
OFF
Operate
Load
(e.g., relay)
Reset
(Between blue and black (orange) leads)
Output circuit
E3X-DA51-S
Operation indicator (orange) ch2
Display
LIGHT ON
(L-ON)
Brown
Operation
indicator
(orange)
ch1
External
input ✽2
Pink
Control output
ch1
Black
Photoelectric
Sensor
main
circuit
Control output
Blue
DARK ON
(D-ON)
12 to
24 VDC
Orange ch2 ✽1 Load
Load
✽1. For the E3X-DA51R-S, this is the APC alarm output.
This output does not exist on the E3X-DA51F-S.
✽2. This input does not exist the E3X-DA51F-S.
E3X-DA9-S
Operation indicator (orange) ch2
Display
LIGHT ON
(L-ON)
Operation
indicator
(orange)
ch1
Brown
Photoelectric
Sensor
main
circuit
Control output
ch1
Black
Control output
Orange ch2 ✽ Load
Blue
12 to
24 VDC
Load
DARK ON
(D-ON)
✽ For the E3X-DA9R-S, this is the APC alarm output.
This output does not exist on the E3X-DA9F-S.
Note: 1. Operation with area settings is as follows:
LIGHT ON: ON when the incident level is between the thresholds for channels 1 and 2.
DARK ON: OFF when the incident level is between the thresholds for channels 1 and 2.
2. Timing Charts for Timer Settings (T: Set Time)
ON delay
OFF delay
One-shot
ON delay and OFF delay
Incident light
Incident light
Incident light
Incident light
No incident light
No incident light
No incident light
No incident light
L-ON
OFF
D-ON
T
ON
ON
OFF
L-ON
OFF
T
D-ON
T
ON
ON
OFF
L-ON
OFF
T
D-ON
T
ON
ON
OFF
L-ON
OFF
T
D-ON
T1
T2
T2
T1
ON
T1: ON-delay set time
T2: OFF-delay set time
T1 and T2 can be set separately.
ON
OFF
13
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@-S (@: 21/51/7/9)
Main Display (Red)
Sub-Display (Green)
Incident level, function, etc.
Threshold, function settings,
etc.
Operation Keys
Function setting
operations
Lock lever
Locks the fiber.
Operation Indicator
(ch1) (orange)
Operation Indicator
(ch2) (orange)
ON when output is ON.
ON when output is ON.
OFF when output is OFF. OFF when output is OFF.
UP
DOWN
MODE
Channel Selector
Note: Nomenclature and operating procedures for the E3XDA@R-S and E3X-DA@F-S (@: 21/51/7/9) are given on
pages 19 and 20.
Use to select the channel to display and set.
Mode Selector
Use to select SET or RUN Mode.
Operating Procedure
1
Setting the Operation Mode
To restore the default
power setting:
The operation mode is set in SET Mode.
➜Refer to 5. Setting Functions on page 16.
MODE
✽ Press the DOWN Key
right after pressing
the MODE Key.
Set the Channel Selector Switch to the desired channel
before making any adjustments or settings.
2
DOWN
PTUN
OFF
Incident level
Threshold
Press
both
for 3 s.
"OFF" will flash twice.
Adjusting the Power (RUN Mode)
The current incident light level can be adjusted near the
power tuning target value (default: 2,000).
This restores the default
setting.
✽ Confirm that the MODE Key setting is PTUN (power tuning). The
default setting is PTUN.
➜Refer to 5. Setting Functions on page 16.
✽ Setting Errors
An error has occurred if one of the following displays appears after
the progress bar is displayed.
✽ If power tuning is executed while SHS is selected for the detection
function, the minimum power will be set.
Display
Flashes twice
Set the SET/RUN Mode
Selector Switch to RUN.
Incident level
Threshold (default)
PTUN
RUN
OVER
(Factory-set to RUN)
Flashes twice
MODE
3s
PTUN
3
Display changes after
specific time.
Incident level
BOTM
Action
The power will not
be tuned. The power
can be increased up
to approximately 5
times the incident
light value.
Bottom Error
The incident light
level is too high
for the power
tuning target
value.
The power will be
turned to the
minimum level. The
power can be
decreased down to
approximately
1/20th the incident
light value.
Setting Thresholds Manually (RUN Mode)
A threshold can be set manually. A threshold can also
be adjusted manually after teaching to fine-tune it.
Power tuning
target value
This completes the
adjustment.
PTUN
Error
Over Error
The incident light
level is too low
for the power
tuning target
value.
Progress bar
Release the key after
the progress bar is
displayed.
Set the Mode Selector
Switch to RUN.
Threshold
Light level
Threshold (default)
RUN
(Factory-set to RUN)
UP
Increases threshold.
DOWN
Decreases threshold.
✽ Even if the display method is changed, the threshold will appear
on the sub-display when the key is pressed.
14
✽
E3X-DA-S
4
Teaching the Threshold (SET Mode)
✽ There are five methods that can be used for teaching, as described
below. Use the method most suitable for the application.
✽ Two-point teaching, positioning teaching, and automatic teaching
can be performed in RUN Mode.
For operating procedures, refer to the Instruction Manual provided
with the product.
✽ An error has occurred if OVER or LO is displayed on the
sub-display. If that occurs, repeat the operation from the beginning.
4-1. Setting the Threshold at Maximum Sensitivity
The threshold can be set to the maximum sensitivity.
This is useful when the longest detection distance is
required.
Set the SET/RUN Mode
Selector Switch to SET.
Incident level
➜Refer to 5. Setting Functions on page 16.
Set the SET/RUN Mode
Selector Switch to SET.
Incident level
Threshold
SET
UP
DOWN
With no workpiece:
TECH
Press
either
for 1 s.
----
"----" will be displayed.
UP
Press
either
for 3 s.
DOWN
With no workpiece:
FULL
UP
DOWN
Press
either
for 3 s.
Threshold
The threshold that
was set will flash twice.
RFCT
Threshold
Incident level
Threshold
The threshold that
was set will flash twice.
Incident level
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
Threshold
4-2. Teaching a Through-beam Fiber Unit without a Workpiece
You can set the threshold to below the incident light level
without a workpiece by the percentage set for the teaching
level.
➜Refer to 5. Setting Functions on page 16.
Set the SET/RUN Mode
Selector Switch to SET.
You can set the threshold to above the incident light level without
a workpiece by the percentage set for the teaching level.
Threshold
SET
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
4-3. Teaching a Reflective Fiber Unit without a Workpiece
Incident level
4-4. Two-point Teaching
4-5. Positioning Teaching
Two points in the following figures are detected, and
the intermediate point of the light levels for the
two points is set as the threshold.
Set the SET/RUN Mode
Selector Switch to SET.
Threshold
Incident level
Threshold
SET
SET
UP
Press
either
for 1 s.
DOWN
With no workpiece:
TECH
----
"----" will be displayed.
With a workpiece:
For positioning
teaching, place the
workpiece where
you want to
position it.
UP
DOWN
Press
either
for 1 s.
Workpiece
TECH
----
"----" will be displayed.
RUN
To RUN
THRU
Threshold
The threshold that
was set will flash twice.
Incident level
This completes the
setting procedure.
Threshold
With no workpiece:
For positioning
teaching, place the
workpiece where
you want to
position it.
UP
DOWN
2PNT
Threshold
Incident level
Threshold
Press
either
for 1 s.
The threshold that
was set will flash twice.
Set the SET/RUN Mode
Selector Switch to RUN
to complete the setting
procedure.
15
E3X-DA-S
5
Setting Functions (SET Mode)
Moving between Functions
➜Refer to 4. Teaching the
Threshold on page 15.
0. Operation mode
Teaching
Set the SET/RUN Mode
Selector Switch to SET.
✽ The function transition boxes show the default settings.
✽ More functions may be displayed depending on the detailed settings.
1. Detection
(To change response speed and
detection precision)
(To set the operation mode)
2. Timer
(To use the timer setting)
3. Teaching level
(To change the teaching level)
SET
4. ATC setting
11. External input memory
MODE
(Refer to the Instruction Manual
provided with the sensor.)
10. External input
(To change functions controlled
using the external input)
When the
settings have
been completed
9. Output setting
8. ECO Mode
(To change outputs for
channel 2)
(To set the ECO Mode)
(To change the ATC setting)
7. Display orientation
(To reverse the orientation of
the display.)
6. Display switch
5. MODE Key
(To change the display method)
(To change the function of the
MODE Key during operation)
Set the SET/RUN Mode
Selector Switch to RUN.
RUN
Functions
UP
DOWN
Use the UP and DOWN Keys to change the settings.
Function ✽
Setting (display)
0. Operation mode
Light ON:
1. Detection ✽
Super-high-speed:
High-resolution:
Description
➜Refer to 1. Setting the Operation Mode on page 14.
, Dark ON:
, High-speed: , Standard:
,
, Tough: , Differential operation:
Used to change the response speed or detection precision.
Differential edge
(differential operation
selected)
Single edge:
Differential time
Single edge···250 µs: , 500 µs: , 1 ms: , 10 ms: , 100 ms: ,
Double edge···500 µs: , 1 ms: , 2 ms: , 20 ms: , 200 ms:
Used to set the differential response time.
Timer disabled:
, OFF-delay timer:
ON-delay timer:
, One-shot timer:
ON-delay + OFF-delay timer:
Used to enable or disable timers.
2. Timer
Time
(timer enabled)
Setting range:
4. ATC setting
ATC enabled:
5. MODE Key ✽
Power tuning target value
(performing power tuning)
Used to set the edge to be detected.
,
1 to 20 ms: 1-ms increments, 20 to 200 ms: 10-ms increments, Used to change timer settings when timers are enabled.
200 ms to 1 s: 100-ms increments, 1 to 5 s: 1-s increments
The timer can be set from 1 to 5,000 ms.
3. Teaching level
Setting at Power-ON
(ATC ON)
, Double edge:
Used to change the threshold setting when teaching a
Through-beam Fiber Unit without a workpiece or teaching
a Reflective Fiber Unit without a workpiece.
to
Used to enable or disable the ATC function.
, ATC disabled:
No setting:
, ATC start processing:
Power tuning and ATC start processing:
Executes power tuning:
Executes a zero reset:
Automatic teaching:
Used to set the processing to be performed when the
power is turned ON.
,
,
, Two-point teaching:
, ATC start:
Setting range: 100 to 3,900 (increments of 100)
Maximum power :
,
Used to change the function of the MODE Key during RUN
operation.
Used to set target values during power tuning.
➜Refer to 2. Adjusting the Power on page 14.
✽ The detection settings and MODE Key settings are the same for channel 1 and channel 2.
Other functions can be set separately for each channel.
16
E3X-DA-S
Function
6. Display switch
Setting (display)
Description
Incident level Threshold
Used to display the incident light level and the
threshold.
% incident level Threshold
Used to display the incident light level as a percentage of
the threshold and the threshold.
PEAK
BOTM
L-PE
D-BT
Used to display the peak and bottom levels of incident
light within a set time. (Updated every 2 s.)
Fixed interval
Use to display the incident light peak level and no incident
light bottom level. (Refreshed when output turns ON or OFF.)
Analog bar display. The current detection status is
displayed as an analog bar. The bar will lengthen
from the right as ON status is reached.
(ON: Red, OFF: Green)
Detection status
Current incident
level
PEAK
Fixed interval
Current incident Peak incident
level
level
Used to display the incident light level and the channel
(unit number).
Incident level Channel (unit number)
7. Display orientation
Normal display:
, Up/down reversed display:
8. ECO Mode
Lit degital display:
OFF:
, Dimmed degital display:
9. Output setting
Each channel:
,
Output when the incident light level is between two thresholds:
Self-diagnosis output:
10. External input
Through-beam, no-workpiece teaching:
,
Reflective, no-workpiece teaching:
,
Two-point teaching:
, Automatic teaching:
Power tuning:
, Zero reset:
,
Light OFF:
, ATC start:
11. External input
memory
Write results to EEPROM:
,
Do not write results to EEPROM:
Used to display the current incident light level and the peak
incident light level. Display changes at a fixed interval.
Used to reverse the orientation of the display.
,
Used to enable or disable the ECO mode.
,
,
Used to change the output details for channel 2.
This setting will be disabled if the detection function is set
to DIFF (i.e., differential operation) and the output will be
used for an alarm output.
Used to change the functions to be controlled using the
external input.
(Refer to the Instruction Manual provided with the sensor.)
Used to set writing the results.
(Refer to Instruction Manual provided with the product.)
17
E3X-DA-S
6
Convenient Functions
6-1. Setting the Digital Display to Zero (Zero Reset)
6-3. Resetting Settings (Initial Reset or User Reset)
The incident light level on the main display can be set to 0.
The incident light level and the threshold will both be
shifted. This is useful when you want to set the reference
display to zero.
All settings can be returned to the factory defaults or to
user-saved settings.
Set the SET/RUN Mode
Selector Switch to SET.
DOWN
SET
✽ Change the function to 0RST (zero reset) with the MODE Key.
The default setting is PTUN.
➜Refer to 5. Setting Functions on page 16.
RST
Set the SET/RUN Mode
Selector Switch to RUN.
UP
INIT
RST
MODE
UP
Press
both
for 5 s.
USER
DOWN
3s
RUN
MODE
MODE
Factory setting
To return to original value for incident light level:
Set the SET/RUN Mode
Selector Switch to RUN.
DOWN
MODE
RUN
USER
YES?
USER
NO?
✽1
Press
both
for 3 s.
UP
MODE
DOWN
MODE
Factory setting
Perform user reset.
6-2. Locking the Keys (Key Lock)
(The steps within the dotted lines can be used if settings have
been saved by the user.)
All key operations can be disabled.
Set the SET/RUN Mode
Selector Switch to RUN.
Operation canceled.
UP
MODE
RUN
✽2
Press
both
for 3 s.
INIT
NO?
INIT
YES?
Factory setting
LOC
ON
UP
MODE
“LOC ON” will flash twice
and key operations will be
disabled.
DOWN
Operation canceled.
MODE
Settings initialized.
To release the lock:
Set the SET/RUN Mode
Selector Switch to RUN.
UP
MODE
RUN
✽2
Press
both
for 3 s.
Saving User Settings
The current settings can be saved.
Set the SET/RUN Mode
Selector Switch to SET.
Factory setting
UP
SET
LOC
Press
both
for 5 s.
OFF
“LOC OFF” will flash twice
and key operations will be
enabled.
✽ If a key is pressed while key operations are locked, “LOC ON” will
flash twice on the display to
indicate that key operations have
been disabled.
✽1. Press the DOWN Key right after pressing the MODE Key.
✽2. Press the UP Key right after pressing the MODE Key.
18
MODE
SAVE
YES?
MODE
SAVE
UP
DOWN
The current settings are saved.
NO?
MODE
Operation canceled.
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@R-S (@: 21/51/7/9)
Main Display (Red)
Sub-Display (Green)
Incident level, function, etc.
Threshold, function settings, etc.
Operation Keys
Lock lever
Function setting
operations
Locks the fiber.
Operation Indicator
(orange)
APC alarm output
indicator (orange)
ON when output is ON.
OFF when output is OFF.
ON when output is ON.
OFF when output is OFF.
UP
DOWN
MODE
Easy key lock Selector
Select to lock or unlock settings.
Mode Selector
Use to select SET or RUN Mode.
Operating Procedure
Basic operating procedures are as given on pages 14 to 18.
For details, refer to the Instruction Manual provided with the product.
This section shows functions specific to the E3X-DA@R-S.
1
Locking the Keys (Easy Key Lock)
Before shipment, all key operation except for the MODE
Keys can be disabled.
Set the SET/RUN Mode
Selector Switch to RUN.
Margin
APC
Margin
APC
Margin
APC
Initial status
Set the Easy Key Lock
Selector Switch to Locked .
Locked
APC margin
displayed in
decrements of 10%
RUN
(Factory-set to RUN)
Note: Do not switch the lock while in SET Mode. Doing so will disable
changing settings. If the lock is switched to in SET Mode, return to
the unlock state, and then make the setting again.
Unlocking
Set the SET/RUN Mode
Selector Switch to RUN.
Set the Easy Key Lock
Selector Switch to Unlocked .
APC margin of less
than 10%
Unlocked
The display switches
every second.
ALAT
APC
Margin
APC
RUN
(Factory-set to RUN)
2
Displaying the APC Margin
Displaying the APC margin can be useful for planning
maintenance. When the APC margin is 0%,
APC alarm output will turn ON, and the APC alarm output
indicator will light regardless of the operation of the APC
margin display.
Set the SET/RUN Mode
Selector Switch to RUN.
The display switches
every 0.5 s.
END
APC
Set the Easy Key Lock
Selector Switch to Locked .
Locked
RUN
Press the MODE Key
or press nothing for 10 s.
(Factory-set to RUN)
Press the MODE Key to
display the following for 10 s.
APC margin is 0%.
MODE
MODE
The display will return
to the normal display.
Incident level
Threshold
19
E3X-DA-S
Nomenclature
Amplifier Units
E3X-DA@F-S (@: 21/51/7/9)
Main Display (Red)
Sub-Display (Green)
Incident level, function, etc.
Threshold, function settings, etc.
Operation Keys
Lock lever
Function setting
operations
Locks the fiber
Operation Indicator
(orange)
UP
DOWN
MODE
Easy key lock Selector
Power tuning
indicator (orange)
Select to lock or unlock settings.
ON when setting is ON.
ON when output is ON.
OFF when output is OFF. OFF when setting is OFF.
Mode Selector
Use to select SET or RUN Mode.
Operating Procedure
Basic operating procedures are as given on pages 14 to 18.
For details, refer to the Instruction Manual provided with the product.
This section shows functions specific to the E3X-DA@F-S.
1
Locking the Keys (Easy Key Lock)
Before shipment, all key operation except for the MODE
Keys can be disabled.
A
STAT
"STAT" will be displayed
and the slow-motion
display will start.
Set the Easy Key Lock
Selector Switch to Locked .
Set the SET/RUN Mode
Selector Switch to RUN.
"A" is displayed when
the output is ON or until
approximately 10 s
has elapsed. (Key
operations will not be
accepted in the status.)
Locked
RUN
(Factory-set to RUN)
Note: Do not switch the lock while in SET Mode. Doing so will disable
changing settings. If the lock is switched to in SET Mode, return to
the unlock state, and then make the setting again.
Unlocking
Set the Easy Key Lock
Selector Switch to Unlocked .
Set the SET/RUN Mode
Selector Switch to RUN.
The incident level in
intervals of 17 µs
will be displayed
for approximately 20 s
every 160 ms
(between 0.5 ms before
ON to 1.5 ms after ON).
Incident level
Threshold
Incident level
Threshold
Incident level
Threshold
Unlocked
RUN
(Factory-set to RUN)
2
Displaying the Change of the incident level
Press the MODE Key,
or wait for the slow-motion
display to end.
Changes of the incident level for high-speed workpiece
detection can be displayed. This enables checking the
margin level of light received and the workpiece ON time
in slow motion.
Set the Easy Key Lock
Selector Switch to Locked .
Set the SET/RUN Mode
Selector Switch to RUN.
The output ON time will
be displayed.
MODE
Output ON time
Unit: µs
Locked
RUN
(Factory-set to RUN)
END
Incident level
END will be displayed.
Threshold
Turn OFF the output or
convey the workpieces.
Incident level
Press the MODE key.
Error
Display
20
The following will be displayed
if the ON time exceeds 1,500 µs.
OVER
US
Threshold
The display will return to
the normal display.
MODE
The following will be displayed
if the change in the light amount is low. ✽
NON
DETC
✽ This may also be displayed when detecting
a workpiece with a small change in light amount
or a slow workpiece of 1,500 µs or longer.
E3X-DA-S
Safety Precautions
To ensure safe operation, be sure to read and follow the Instruction Manual provided with the sensor.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
CAUTION
Do not use the sensor with voltage in excess of the
rated voltage. Excess voltage may result in
malfunction or fire.
Never use the sensor with an AC power supply.
Otherwise, explosion may result.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Amplifier Unit
Designing
Operation after Turning Power ON
The sensor is ready to detect within 200 ms after the power supply is
turned ON. If the sensor and load are connected to separate power
supplies, be sure to turn ON the sensor first.
Time may be required for the incident level to stabilize after the power
supply is turned ON.
Operation at Power OFF
A pulse may be output when the power supply is turned OFF. Turn
OFF the power supply to the load or the load line before turning OFF
the power supply to the sensor.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation
of the sensor.
1. Do not use the sensor in an environment where explosive or
flammable gas is present.
2. Do not use the sensor in a location subject to splattering with
water, streams, oils, or chemicals.
3. Do not attempt to disassemble, repair, or modify the sensor.
4. Do not apply voltages or currents that exceed the rated range to
the sensor.
5. Do not use the sensor in an ambient atmosphere or environment
that exceeds the ratings.
6. Wire the power supply correctly, including the polarity.
7. Connect the load correctly.
8. Do not short-circuit the load at both ends.
9. Do not use the sensor if the case is damaged.
10.Dispose of the sensor as industrial waste.
11.Do not use the sensor in locations subject to direct sunlight.
Mutual Interference Protection Function
Mutual interference prevention is enabled if Amplifier Units are
connected together. It is also enabled in the same way if E3X-DA-Sseries Units and E3C-LDA-series Units are used together.
Mounting
Connecting and Disconnecting Connectors
Mounting Connectors
1. Insert the Master or Slave connector into the Amplifier Unit until it
clicks into place.
Insert
2. Attach the protective seals (provided as accessories) to the sides
of master and slave connectors that are not connected.
Seal
Note: Attach the seals to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit away from the other unit.
2. After the Amplifier Unit has been separated, press down on the
lever on the connector and remove it. (Do not attempt to remove a
connector without first separating the Amplifier Unit from the other
Units.)
Press down
Lever
Remove
21
E3X-DA-S
Adding and Removing Amplifier Units
Fibers with E39-F9 Attachment
Adding Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
Fiber Unit
9 mm
13 mm
Fibers That Cannot Be Free-Cut (with Sleeves)
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
Click into place
9 mm
13 mm
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
2. Disconnecting Fibers
Remove the protective cover and raise the lock lever to pull out the
fibers.
Note: 1. The specifications for ambient temperature will vary
according to the number of Amplifier Units used together.
For details, ➜refer to Ambient temperature range on
page 4.
2. Always turn OFF the power supply before joining or
separating Amplifier Units.
Protective cover
Locked
Unlocked
Mounting the End Plate (PFP-M)
Use an End Plate if the Amplifier Unit might move due to vibration.
Note: 1. To maintain the fiber properties, confirm that the lock is
released before removing the fibers.
2. Be sure to lock or unlock the lock lever within an ambient
temperature range between −10°C and 40°C.
Adjusting
Mutual Interference Protection Function
The values that appear on the digital display may fluctuate somewhat
due to light from other sensors. If this occurs, you can stabilize
detection by setting a threshold that is close to half way between the
incident levels with and without a sensing object.
End Plate
Fiber Connection
The E3X Amplifier Unit has a lock lever for easy connection of the
Fiber Unit. Connect or disconnect the fibers using the following
procedures:
1. Connecting Fibers
Open the protective cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
Protective cover
Lock lever
Locked
Unlocked
Insertion position
Output Short-circuits
OVER/CUR will flash on the display if the output short-circuit
protection function operates due to a load short-circuit in a control
output. If this occurs, check the load connections.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Others
Protective Cover
Fiber insertion mark
Always keep the protective cover in place when using the Amplifier
Unit.
Fiber
9 mm
Note: Do not pull on the fiber, apply pressure on it, or otherwise
subject it to excessive force when it is attached to the
Amplifier Unit. (Use a force of 0.3 N·m max.)
Mobile Console
The E3X-MC11-SV2 Mobile Console does not currently support the
new Tough Mode and ON-delay + OFF-delay timer. You also cannot
use the E3X-MC-S.
Communications Unit
Use an E3X-DRT21-S Version 3 Communications Unit. This is not
supported for the E3X-DA@R-S and E3X-DA@F-S (@: 21/51/7/9).
22
E3X-DA-S
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Amplifier Units
Pre-wired Models
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
E3X-DA21F-S
E3X-DA51F-S
Digital Display Area
✽1. The indicators are as follows:
Indicator ✽1
15.6
35.25
10
6.3
Operation indicator (1ch)
Main display
Sub-display
E3X-DA21-S
E3X-DA51-S
Operation indicator
(2 ch)
E3X-DA21R-S
E3X-DA51R-S
APC alarm output
indicator
E3X-DA21F-S
E3X-DA51F-S
Power tuning
indicator
DIN track mounting
4.3
141.1
180°
101.45
Vinyl-insulated round cable
Standard length: 2 m ✽2
32
(9)
4.5
Multiple connection diagram
12.5
5.65
3.4
End Plate
(sold separately)
PFP-M
L
Two, 2.4 dia.
Hole for optical communications
18.7
(36.2)
(21.3)
70
Center of DIN track
DIN track
(sold separately)
PFP-@N
10
The number of expansion
1
2
3
4
5
6
7
8
9
10
Fiber Attachment mounted (E39-F9)
10
With Mounting Bracket Attached
4.3
10
L (mm)
10
20
30
40
50
60
70
80
90
100
141.1
180°
101.45
Vinyl-insulated round cable
Standard length: 2 m ✽2
32
(9)
4.5
12.5
5.65
3.4
Two, 2.4 dia.
10.3
Two, 3.2 dia.
Holes
18.7
Hole for optical communications
4.3
(9.4)
16
70
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Mounting Holes
3.4
2-M3
4.4
16
28.1
16
Fiber Attachment mounted (E39-F9)
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the
Amplifier Units if they are mounted side by side.
✽2. The cable specifications are as follows:
E3X-DA21-S
E3X-DA51-S
E3X-DA21R-S
E3X-DA51R-S
4 dia. cable / 5 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
E3X-DA21F-S
E3X-DA51F-S
4 dia. cable / 3 conductors
(Conductor cross section: 0.2 mm2,
Insulator diameter: 1.1 mm)
23
E3X-DA-S
Wire-saving connector Models
E3X-DA7-S
E3X-DA9-S
E3X-DA7R-S
E3X-DA9R-S
10
E3X-DA7F-S
E3X-DA9F-S
✽1. The indicators are as follows:
Digital Display Area
Indicator ✽1
15.6
35.25
6.3
Operation indicator (1ch)
Main display
Sub-display
E3X-DA7-S
E3X-DA9-S
Operation indicator
(2 ch)
E3X-DA7R-S
E3X-DA9R-S
APC alarm output
indicator
E3X-DA7F-S
E3X-DA9F-S
Power tuning
indicator
DIN track mounting
4.3
141.1
8.1
180°
101.45
Dia. A ✽2
32
(9)
4.5
12.95
5.65
3.4
Two, 2.4 dia.
Hole for optical communications
18.7
(36.2)
Multiple connection diagram
(21.3)
70
End Plate
(sold separately)
PFP-M
L
Center of DIN track
DIN track
(sold separately)
PFP-@N
10
10
The number of expansion
1
2
3
4
5
6
7
8
9
10
Fiber Attachment mounted (E39-F9)
10
With Mounting Bracket Attached
L (mm)
10
20
30
40
50
60
70
80
90
100
4.3
141.1
8.1
180°
101.45
Dia. A ✽2
32
(9)
4.5
12.95
5.65
3.4
Two, 2.4 dia.
10.3
Two, 3.2 dia.
Holes
18.7
Hole for optical communications
(9.4)
16
4.3
70
Mounting Bracket (E39-L143)
SUS304 stainless steel (sold separately)
Mounting Holes
3.4
4.4
2-M3
✽2. The cable diameters are as follows:
16
28.1
16
Fiber Attachment mounted (E39-F9)
Note: When using E39-L143 Mounting Brackets, there will be small gaps between the Amplifier
Units if they are mounted side by side.
24
E3X-CN21 (4 conductors)
E3X-CN22 (2 conductors) 4.0 dia.
E3X-CN11 (3 conductors)
E3X-CN12 (1 conductor)
2.6 dia.
E3X-DA-S
Wire-saving connector
Master connector
E3X-CN21
2,000+50
0
Edge of amplifier
(7)
✽
✽ E3X-CN21: 4-dia. vinyl-insulated round cable with 4 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave connector
E3X-CN22
2,000+50
0
Edge of amplifier
(7)
✽
✽ E3X-CN22: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Master connector
E3X-CN11
2,000+50
0
Edge of amplifier
(7)
✽
✽ Cable 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
Slave connector
E3X-CN12
2,000+50
0
Edge of amplifier
(7)
✽
✽ Cable 2.6-dia. vinyl-insulated round cable with 1 conductors (Conductor cross section: 0.2 mm2, Insulator diameter: 1.1 mm)
25
E3X-DA-S
Accessories (sold separately)
Mounting Brackets
E39-L143
34.8
22
16
2.5
(10.3)
3
Mounting Holes
7.3
5.3
2-M3
26.8
Two, 3.2 dia.
3
16
7
16±0.1
3
Four, R1.7
3.4
10.3 10 max. 7
Material: Stainless steel (SUS304)
1
3.4
End Plate
PFP-M
11.5
1
50
M4×8
panhead screw
10
M4 spring washer
4.8
6.2
10
1
1.3
1.8
35.5
1.8
35.3
For information on Fiber Units, refer to the Fiber Sensors Best Selection Catalog (Cat. No. E353).
26
READ AND UNDERSTAND THIS DOCUMENT
Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or
comments.
WARRANTY
OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRON's safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the
customer’s application or use of the product.
At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply
to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
• Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject
to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix
or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This document shall not be copied for sales or promotions without permission.
This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or
reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in
its entirety.
OMRON Corporation
Industrial Automation Company
Authorized Distributor:
Tokyo, JAPAN
Contact: www.ia.omron.com
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
© OMRON Corporation 2010 All Rights Reserved.
In the interest of product improvement,
specifications are subject to change without notice.
Printed in Japan
CSM_1_1_0510
Cat. No. E396-E1-02
(0510)