Bothhand AD-1102S Adsl line transformer Datasheet

Bothhandusa.com
ADSL LINE TRANSFORMER
.
P/N: AD-1102S DATA SHEET
Feature
!
!
!
!
!
!
!
Designed to meet UL 1950 and IEC 950 safety
requirements.
Meets IEC 695,2-2 flammability requirements.
PWB Process Capability: standard printed wiring board
assembly techniques, total-immersion cleaning.
Reliability testing: shock, vibration, temperature cycling,
temperature – humidity – bias.
Minimum inter winding breakdown voltage 1500 Vrms.
Operating Temperature: -10℃ to+60℃.
Storage Temperature: -25℃
℃ to +75℃
℃.
Electrical Specifications @ 25°C
Part
Turn Ratio (±2%)
DCR (Ω Max)
Longitudinal Balance
Number
(1-3):(2-4):(10-8):(9-7)
(1-3)=(2-4)
(10-8)=(9-7)
(dB Min)
AD-1102S
1:1:2:2
6
7
-60
3
Additional Specifications
2
Insertion Loss
Number
(dB Max)
(dB Max)
(dB Min)
AD-1102S
-4
-10
-85
Schematic
Return Loss
1
Part
Harmonic Distortion
4
5
Indcutance (mH ±10%)
@(1-4) / shorted (2-3)
3.125
Mechanical
462 Boston St - Topsfield, MA 01983 - Phone: 978-887-8050 - Fax: 978-887-5434
A1(03/01)